- Projections:- No projection of any sort whatsoever extending more than 23cm. (or 9 in) below a height of 4.3 m. (or 14ft.) such as projection on the level of chabutara, Chajja, cornice, water spouts, drains, pipes, advertisement boards and the like shall project over the land of the road or over any drain or over any portion outside the boundaries of the site, provided that projections arising out of the vertical part of the rain water spouts projecting at the road level or the water pipe may be permitted in accordance with the drainage plan.
[14]
23 Sun-shades over windows and ventilators:-
(a) Notwithstanding anything contained in these byelaws, no projection of any sort shall be permitted over the land of the road or over any drain or any other portion outside the boundaries of the site below a height of 4.3 m. (or 14ft.) from the ground level.
(b) Sunshades provided above a height of 4.3 m. (or 14ft.) from the ground level shall be permitted to project upto a maximum width of 60 cm. (or 24 in) if the road over they project exceeds 9 m. (or 30ft.) in width.
(c) No projection of any short whatsoever shall be permitted on roads less than 9m. (or 30ft.) in width or on roads having no footpaths.
- No construction shall be permitted beyond the set back line as provided below
(i) Minimum set back line of the Pallel road from the crossing of the said road and Rifle Range road upto the junction of Pallel road and Keishamthong road is 6 m. (20 ft.) from that part of the boundary of the plot which abuts on the road.
(ii) Minimum set back line of any other public road in the Municipal area is 1.5 m. (5ft.) from that part of the boundary of the plot which abuts on the road.
(iii) Minimum set back line of the National Highway, State Highway, Major Roads and road which are considered to be important in the Municipal area is 3 m. (10ft.) from that part of the boundary of the plots which abuts on the road.
Name of the roads are indicated as the following:-
(1) Kangchup and Uripok Road.
(2) Sagolband Road
(3) Mayang Imphal Road
(4) Nagamapal Road and Nityainanda Leirak Road
(5) Tiddim Road
(6) Pallel Road
(7) Yairipok Road
(8) Ayangpalli Road
(9) Nongmeibung Telipati Road
[15]
(10) Ukhrul Road
(11) Dimapur Road
(12) Thangmeiband Road
(13) Road running from Lilashing Khongnangkhong to Lamlong Road
(14) Kongba to Singjamei then to Pishumthong
(15) Khagempali Road continuing Mayaikoibi then to Naoremthong
(16) Uripok Laishram Leirak road linking Lamphel road in the west and north of the Hospital then Lamphel approach road in the north of Lilashing Khongnangkhong.
(iv) For residential plots, the minimum set back from the boundary of the plot in the front, rear and both sides is 1.5 m. (5 ft.) and 0.75 m. (2½ft.) respectively. This will not, however, affect the set back line given in (i) above. And in the case of twin building, it will be treated as one building for the purpose of side set back.
(v) In the bazar area, the side set back is 21/2 ft. other set back lines in the front and rear will remain the same as applicable to the roads concerned stated above.
(vi) In case of corner plots side space the roads shall not be less than 1.5 m. (5 ft.) from the boundary of the public road.
- (i) Habitable Room- The height of all rooms for human habitation shall not be less than 2.75 m. (or 9 ft.). The size of the habitable room shall not be less than 9.5 sq. metres (or 100 sq.ft.) with a minimum width of 2.4 m. (or 8 ft). Habitable room shall be provided for the purpose of light and ventilation with windows, doors, ventilators and other apertures having a total area of not less than 1/8th of the floor area of the room excluding doors.
(ii) Bath room, WCs and Stores- The height of all such rooms measured from the floor to the lowest point in the ceiling shall not be less than 2.4 m. (or 8 ft.). Nothing on the ground floor shall be constructed in such a way as to leave a headway of less than 2.4m. (or 8 ft.) provided that in the case of a passage under the landing the minimum headway may be kept as 2.1 m.(or 7 ft.). The size of a bath room shall not less than 1.5 x 1.2 m. (or 5' x 4' ft.) or 1.8 sq. metres or (20 sq. ft.) if it is combined bath room and water closet its floor areas shall not be less than 2.8 sq.metres (or 30 sq. ft.). The minimum floor area of a W.C. shall be 1.1 sq. metres (or 12 sq. ft.) Bath room and w.c's shall be provided with natural light and ventilation by windows and ventilators.
[16]
(iii) Kitchen:- The height of the kitchen measured from the floor to the lowest point the ceiling shall not be less than 2.75 m. (or 9 ft).
Every kitchen shall have a floor area of not less than 4.8 sq. m.(or 50 sq. ft.) if there is store or 5.6 sq. metres (or 60 sq. ft.) if there is no store and shall not be less than 1.8 m. (or 6 ft.) in width of any part. A kiitchen which is intended for use as-dining room also shall have a floor area of not less than 9.5 sq. metres (or 100 sq. ft.) with a minimum width of 2.4 m (or 8 ft.).
Every kitchen shall be provided with a flue and properly ventilated with doors, windows and ventilators to be standard prescribed for habitable rooms.
26 Stair Case:-
(i) The minimum clear width of stair cases in case of residential buildings shall not be less than 1 m. (or 3 ft.).
(ii) In case of public buildings a stair case shall be provided for every 300 persons which are expected to use the building. No stir case shall be less than 1.5 m. (or 5 ft.) in width and the farthest comer of the building shall not be more than 18 m. (or 60 ft.) distant from the stair case.
The minimum riser and minimum width of tread of stair case shall be as follows: Type of building Maximum riser Minimum Tread width Public building 15 cm. (or 6 inch) 30 cm. (or 12 inch) Domestic buildings 19 cm. (or 71/2 inch) 25 cm. (or 10 inch)
(iii) No flight of stair case should consist of more than 16 steps a time. After that there should be a landing or half landing.
(iv) The minimum clear head room in any stair case shall be 2.1 m. (or 7 ft.) as measured from the top of the riser upto the lowest portion of the ceiling perpendicular above it. Every stair case shall be properly lighted and ventilated.
- Drainage and Sanitation:- Sites containing Deposited Refuses- No building shall be constructed on any site, on any part of which there is deposited refuse, excreta or other offensive matter to which the Public Health Authority object until refuse has been removed there from and the site has been prepared or left in a manner suitable for building purpose to the satisfaction of the Council.
Provided that, where it is intended to find a building on piles or on reinforced concrete pillars, the Council may approve the erection of such building after the refuse has been appropriately treated by chemical or in some other manner to the satisfaction of the council and has been covered by a layer of sand or other suitable materials to a depth of not less than 0.6 m. (or 2 ft.) or by a layer of cement concrete not less than 15 cm. (or 6 in) thick.
[17]
28 Privy, Type to be allowed in an area:-
(i) The Council shall determine in each case whether the premises shall be served by a connected latrine or septic tank or other type, provided that it shall be a connected latrine if a sewer is within 30 m. (or 100 ft.) of the site, provided further that until the sewer begins to function a served latrine may be permitted subject to the condition that it shall be converted into a connected latrine as and when required by the Council.
(ii) The Council may refuse to permit the construction of any latrine or urinal at a particular place, if in its opinion, such latrine or urinal would be a nuisance in the neighbourhood or would be objectionable to the occupants of the neighbouring buildings.
(iii) Every house should have one latrine, pit latrines should be at least covered and away from the tank, living room and kitchen by at least 25 ft.
(iv) Cow-sheds should be 25 ft. away from living rooms, kitchen, tank.
29 Rain water Pipes:-
(a) (i) Rain water pipe shall be at least 75 mm. (or 3 in) in diameter and be constructed of cast iron, wrought iron glazed stoneware, asbestos or other equally suitable material and shall be securely fixed.
(ii) A rain water pipe conveying rain water shall discharge directly or by means of a channel into or over an inlet to a surface drain or shall discharge freely in a compound drain to a surface drain, but in no case shall it discharge directly into any closed drain.
(iii) Whenever a rain water pipe cannot discharge into or over an inlet to a surface drain or in a compound drain to a surface drain and if a street drain within 30 m (or 100 ft.) from the boundary of the premises, such rain water pipe shall discharge into a gully which shall be connected with the street drain.
(iv) If such street drain is not available within 30 m.(or 100 ft.) of the boundary of the premises, a rain water pipe may discharge over a street provided its outlet is not more than 30 cm. (or 1 ft.) above the surface of the street.
(v) A rain water pipe shall not discharge into or connect with any soil pipe or soil ventilation pipe or any waste pipe or any waste ventilation pipe, nor shall it discharge into a sewer unless specifically permitted to do so by the Council in which case such discharge into a sewer shall be intercepted by means of a gully trap.
(b) All sullage drains of a building shall be connected to the back street or land and not on the main road on which the building abuts without the special permission of the Council.
[18]
- The penalty for the infringement of any of the bye-law Nos. 22 to 29 shall be (a) a fine not exceeding Rs. 500/- and in the case of continuing infringement a daily fine not exceeding Rs. 100/- for each day after written notice of the offence is served by the Chairperson or the authorised officer.