This report to accompany the application for Building Permission.
-
In case information on items 3, 10, 17, 18 and 19 cannot be given at this time, it should be submitted at least one week before commencement of construction.
| Part 1 General Data | |||
| Sl.No. | Description | Information | Notes |
| 1 | Address of the building* Name of the building* Plot number* Subplot number* TPS schemea. Nameb. Number* Locality/Township* District | ||
| 2 | Name of the owner | ||
| 3 | Name of builder on record | ||
| 4 | Name of Architect/Engineer on record | ||
[44]
| 5. | Name of Structural Engineer on record | ||
|---|---|---|---|
| 6. | Use of the building | ||
| 7. | Number of storeys above ground level(including storey to be added later, if any) | ||
| 8. | Number of basements below ground level | ||
| 9. | Type of structure■ Load bearing■ R.C.C. frame■ R.C.C. frame and shear walls■ Steel frame | ||
| 10. | Soil data■ Type of soil■ Design safe bearing capacity | IS: 1893 CI.6.3.5.2IS: 1904 | |
| 11. | Dead load (unit weight adopted)■ Earth■ Water■ Brick masonry■ Plain cement concrete■ Reinforced cement concrete■ Floor finish■ Other fill materials■ Piazza floor fill and landscape | IS: 875 Part 1 | |
| 12. | Imposed (Live) loads■ Piazza floor accessible to Fire Tender■ Piazza floor not accessible to Fire Tender■ Floor loads | IS: 875 Part 2 | |
| 13. | Cyclone/Wind■ Speed■ Design pressure intensity | IS: 875 Part 3 | |
| 14. | Seismic zone | IS: 1893 (2002) | |
| 15. | Importance factor | IS: 1893 (2002) Table 6 | |
| 16. | Seismic zone factor (Z) | IS: 1893 Table 2 | |
| 17. | Response reduction factor | IS: 1893 Table 7 | |
| 18. | Fundamental natural period-approximate | IS: 1893 CL. 7.6 | |
| 19. | Design horizontal acceleration spectrum value (Ah) | IS: 1893 CL. 6.4.2 | |
| 20. | ■ Expansion/Separation joints |
■ Enclose small scale plants of each floor on A4 sheets.
In case terrace garden is provided, indicate additional fill load and live load.
■ Indicate on a small scale plan on A4 sheet.
[45]
| Part 2 Laod bearing masonry buildings | |||
| Sl. No. | Description | Information | Notes |
| 1 | ■ BuildingCategory | IS:4326 CL. 7 read with IS:1893 | |
| Zone II Bldg III IV V | |||
| Ordinary B C D E | |||
| Important C D E E | |||
| 2 | Basement provided | ||
| 3 | Number of floors including ground floor (all floors including stepped floors in hill slopes) | ||
| 4 | Type of wall masonry | ||
| 5 | Type and mix of mortar | IS:4326 CL. 8.1.2 | |
| 6 | Re : size and position on openings (see note No. 1)■ Minimum distance (b5)■ Ratio (b1+b2+b3)/11 or (b6+b7)12 Minimum pier width between consequent opening (b4)■ Vertical distance (h3)■ Ratio of wall height to thickness 4■ Ratio of wall length between cross wall to thickness | IS:4326 Table 4, Fig. 7 | |
[46]
| 1 | 2 | 3 | 4 | |
| 7 | Horizontal seismic bandAt plinth levelAt window sil levelAt lintel levelAt ceiling levelAt eave level of sloping roofAt top of gable wallsAt top of ridge walls | IP NA☐ ☐☐☐ ☐☐☐ ☐☐☐ ☐☐☐ ☐☐☐ ☐☐☐ ☐☐☐ | (See Note No. 2)IS:4326 CL 8.4.6IS:4326 CL 8.3IS:4326 CL 8.4.2IS:4326 CL 8.4.3IS:4326 CL 8.4.3IS:4326 CL 8.4.4 | |
| 8 | Vertical reinforcing barAt corners and T junction of wallsAt jambs of doors and window openings | IS:4326 CL 8.4.8IS:4326 CL 8.4.9 | ||
| 9 | Integration of prefab roofing/flooring elements through reinforced concrete screed | ☐ ☐☐ | IS:4326 CL 9.1.4 | |
| 10 | Horizontal bracings in pitched trussIn horizontal plane at the level of tiesin the slopes of pitched roofs | ☐ ☐☐☐ ☐☐ | ||
Notes :
-
Information in item 6 should be given on separate A4 sized sheets for all walls with large number of openings
-
IP. Indicated "Information Provided"
-
TP indicates "Information to be provided"
-
NA indicates "Not applicable"
-
Tick mark one bax.
[47]
APPENDIX-B (continued)
| Part 3 Reinforced concrete framed buildings | |||
| Sl.No. | Description | Information | Notes |
| 1 | Type of building ■ Regular frames ■ Regular frames with shear walls ■ Irregular frames ■ Irregular frames with shear walls ■ Soft storey | IS: 1893 CL. 7.1 | |
| 2 | Number of basements | ||
| 3 | Number of floors including ground floor | ||
| 4 | Horizontal floor system ■ Beams and slabs ■ Waffles ■ Ribbed floor ■ Flat slab with drops ■ Flat plate without drops | ||
| 5 | Soil Data ■ Type of soil ■ Recommended type of foundation -Independent footings -Raft -Piles ■ Recommended bearing capacity of soil ■ Recommended, type, length, diameter and load capacity of piles ■ Depth of water table ■ Chemical analysis of ground water ■ Chemical analysis of soil | IS: 1498 | |
| 6 | Foundations ■ Depth below ground level ■ Type ■ Independent ■ Interconnected ■ Raft ■ Piles | ||
| 7 | System of interconnecting foundations ■ Plinth beams ■ Foundation beans | IS: 1893 CL. 7.12.1 | |
| 8 | Grades of concrete used in different part of building | ||
[48]
| 1 | 2 | 3 | 4 |
|---|---|---|---|
| 9 | Method of analysis used | ||
| 10 | Computer software used | ||
| 11 | Torsion included | IS: 1893 CL.7.9 | |
| 12 | Base sheara. Based on approximate fundamental periodb. Based on dynamic analysisc. Ration of a/b | IS: 1893 CL.7.5.3 | |
| 13 | Distribution of seismic forces along the height of the building | IS: 1893 CL.7.7(provided sketch) | |
| 14 | The column of soft ground storey specially designad | IS: 1893 CL.7.10 | |
| 15 | Clear minimum cover provided in■ Footing■ Column■ Beams■ Slabs■ Walls | IS: 456 CL.26.4 | |
| 16 | Ductile detailing of RC frame■ Type of reinforced used■ Minimum dimension of beans■ Minimum dimension of columns■ Minimum percentage of reinforcement of beans at any cross section■ Maximum percentage of reinforcement at any section of beam■ Spacing of transverse reinforcement in 2-d length of beams near the ends.■ Ratio of capacity of beams in shear to capacity of beams in flexure■ Maximum percentage of reinforcement in column | IS: 456 CL.5.6IS: 13920CL. 6.1IS: 13920CL. 7.1.2IS: 456 CL.26.5.1.1.(a)IS: 13920 CL.6.2.1IS: 456 CL.26.5.1.1.(b)IS: 13920CL.6.2.2IS: 13920CL.6.3.5 |
[49]
| 1 | 2 | 3 | 4 |
|---|---|---|---|
| ■ confining stirrups near ends of columns and in beam-column jointsa. Diameterb. Spacing■ Ration of shear capacity of columns to maximum seismic shear in the storey | IS : 456 CL.26.5.3.1IS : 13920CL. 7.4 |