Every person who erects a building shall provide a means of access to such building a clear way, not less than 3.6 m. (or 12 ft.) in which upto 3 storeys and 5 m. (or 16 ft.) in width beyond three storeys from a street to the entrance door of such building, such pathway to be, so long as it is used as a means of access to that building maintained free from any obstruction and shall not at any time cause or permit any portion of any building below a height of 5 m. (16 ft.) to overhang or project over or into such passage.
-
No building shall be erected so as to deprive any other building of the means of access as provided in this chapter.
-
Every person who erects a building shall indicate upon any plan, required to be furnished by him in accordance with these byelaw, the whole area of such means of access by a distinguishing colour and description.
-
Every person who erects a building shall not at any time erect or cause or permit to be erected or re-erected any building which in any way encroaches upon or diminished the area so set apart for this purpose.
-
the space so set apart shall be separately distinguished from any house gully or open space required to be provided under any other byelaw enforced by the Council.
-
Every such means of access shall be drained and lighted to the satisfaction of the Board and manhole covers OT other drainages, water or any other fittings laid in such means of access shall be flush with the finished surface level so as not to obstruct the safe travel over the same.
-
A person who under takes construction work on building shall not reduce the access to any building previously existing below the minimum width as required under Byelaw 31.
-
The means of access under these byelaws shall not be deemed to be suitable and sufficient until they have been approved by Board who shall have power to prescribe the width of the clear way which he shall communicate.
-
Access to Dwelling Units and Rooms- In every building containing more than one dwelling, access shall be provided to each dwelling unit without the necessity of passage through any other dwelling unit.
[19]
40 Open Space Requirements:-
Open Air Space:- Every room intended for human habitation shall abut on an interior or exterior open air space or on an open verandah opening on to such interior or exterior toilet open space.
-
Joint Open Air Space:- Every such interior or exterior open air space unless the latter is a street, shall be maintained for the benefit of such building exclusively and shall be entirely within the owner's own premises.
-
If such interior or exterior open air space is intended to be used for the benefit or more than one building belonging to the same owner, then the width of such open air space shall be equal to one-half of the height of the tallest building on such open air space.
-
Open Space to be open to Sky Every open space, whether exterior or interior, provided in pursuance of any regulation or byelaw or under an agreement lodged with the Board shall be kept free from any erection thereon.. shall be open to the sky. Every open space or, chowk provided under these byelaws shall have a suitable and sufficient access. No open drain, except for rain water, shall be constructed in any open space required by these byelaws.
44 Open Space Around Residential Buildings
(a) Front Open Space:
(1) Every residential building shall have a front of minimum width 3 m. (or 10 ft.) and in the case of two or more sides a width of an average of 3 m. (or 10 ft.) and in no case shall not be less than 1.8 m. (or 6 ft.). Such a yard shall form an inseparable part of the site of the building.
(2) In the case of residential building whose rear boundary abuts a public road, no erection, re-erection or material alteration of that building shall be undertaken if the opposite egde of the back street on which the building abuts, straight lines drawn downwards and outwards from the line of intersection of the true surface of any rear wall of the building with the roof perpendicular to that line form an angle of more than 63° to the horizontal.
(3) Rear Open Space to Extend throughout the Rear Wall-The Rear open space provided under the foregoing clauses shall be co-extensive with the entire face of the rear wall. If a building abuts on two or more public roads, such rear open space shall be provided throughout the entire face of the rear wall. Such rear wall shall be the wall and the opposite side of the face of the building abutting on the wider street unless the Board otherwise direcets.
(b) Side Open Space
(1) Every residential building shall have a permanently open air space not less than
[20]
1.2 m. (or 4 ft.) on both sides other than its flout and rear, and such side open space shall form an inseparable part of the site. If any of the sides of such building abuts on public road then the side open space shall be equal to the minimum front open space prescribed under this bye-law.
(2) Every habitable room not receiving light and air from either the front or rear of a building in accordance with 45° to 60° rules shall have the whole of one side thereof abutting an open space a permanently inseparable part of the site.
-
Open Space for Building other than Residential:- The rules applicable to residential building with regard to front open space, rear open space and side open space and the angles 45⁰ and 631/2 governing erection, re-erection or material alteration of a residential building shall also be applicable to business and industrial building with the approval off the Chief Commissioner.
-
Safeguard against Reduction of Open Space:- No construction work on a building shall be allowed if such work operation to reduce an open air space of any other adjoining building belonging to the same over to an extent less than what is prescribed by any of the byelaws in force at the time of the proposed work or reduce further such open space if it is already less than that prescribed.
-
Building Abutting on Two public roads:- If a building abuts on two or more public roads of different widths, the building shall be deemed for the purpose of the bye-law to face upon the road that has the greater width and the height of the building shall be regulated by the width of the road and may be continued at this height to a depth of 13.5m (or 44 ft.) along the narrow road subject to conformity with bye-laws 44 and 45.