This report to accompany the application for Building Permission.
-
In case information on items 3, 10, 17, 18 and 19 cannot be given at this time, it should be submitted at least one week before commencement of construction.
| Part 1 General Data | Part 1 General Data | Part 1 General Data | Part 1 General Data |
| S. No | Description | Information | Notes |
| 1 | Address ofthe building • Name ofthe building • Plot number • Subplot number • TPS scheme a. Name b. Number • Locality / Township • District | ||
| 2 | Name ofthe owner | ||
| 3 | Name ofbuilder on record | ||
| 4 | Name ofArchitect/Engineer on record | ||
| 5 | Name ofStructural Engineer on record | ||
| 6 | Use ofthe building | ||
| 7 | Number of storeys above ground level (including storey to be added later, ifany) | ||
| 8 | Number ofbasements below ground level | ||
| 9 | Type ofstructure • Load bearing • R.C.C frame • R.C.C frame and shear walls • Steel frame• | ||
| 10 | Soil data • Type ofsoil • Design safe bearing capacity | IS: 1893 Cl.6.3.5.2 IS: 1904 | |
| 11 | Dead load (unit weight adopted) • Earth • Water • Brick masonry • Plain cement concrete • Reinforced cement concrete • Floor finish • Other fill materials Piazza floor fill and landscape | IS:875 Part 1 | |
| 12 | Imposed (Live) loads • Piazza floor accessible to Fire Tender • Piazza floor not accessible to Fire Tender ♥Floor loads ♦ Roofloads | IS: 875 Part 2 | |
| 13 | Cyclone / Wind • Speed • Design pressure intensity | IS: 875 Part 3 | |
| 14 | Seismic zone | IS: 1893 (2002) | |
| 15 | Importance factor | IS: 1893 (2002) Table6 | |
| 16 | Seismic zone factor (Z) | IS: 1893 Table 2 | |
| 17 | Response reduction factor | IS: 1893 Table 7 | |
| 18 | Fundamental natural period -approximate | IS: 1893 CL. 7.6 | |
| 19 | Design horizontal acceleration spectrum value (Ah) | IS: 1893 CL. 6.4.2 | |
| 20 | ♠ Expansion / Separationjoints |
♥ Enclose small scale plans of each floor on A4sheets
♦ In case terrace garden is provided, indicate additional fill load and live load
♠ Indicate on a small scale plan on A4 sheet
APPENDIX-B (continued)
| Part 2 Load bearing masonry buildings | ||||
| S. No. | Description | Information | Notes | |
| 1 | • Building category | IS: 4326 CL. 7 read with IS: 1893 | ||
| Zone Bldg | II III IV V | |||
| Ordinary | B C D E | |||
| Important | C D E E | |||
| 2 | Basement provided | |||
| 3 | Number of floors including Ground floor (all floors including stepped floors in hill slopes) | |||
| 4 | Type ofwall masonry | |||
| 5 | Type and mix ofmortar | IS: 4326 CL. 8.1.2 | ||
| 6 | Re: size and position of openings (see note No.1) • Minimum distance (b5) | IS: 4326 Table 4, Fig. 7 | ||
| • | • Ratio b1 +b2 +b3)/11 or (b6 + b7)12 Minimum pier width between consequent opening (b4) • Vertical distance (h3) • Ratio ofwall height to thickness 4 • Ratio of wall length between cross wall to thickness | ||
|---|---|---|---|
| 7 | Horizontal seismic band • At plinth level • At window sil level • At lintel level • At ceiling level • At eave level ofsloping roof • At top ofgable walls • At top ofridge walls | IP TP NA | (See Note No. 2) IS: 4326 CL 8.4.6 IS: 4326 CL 8.3 IS: 4326 CL 8.4.2 IS: 4326 CL 8.4.3 IS: 4326 CL 8.4.3 IS: 4326 CL 8.4.4 |
| 8 | Vertical reinforcing bar • At corners and Tjunction ofwalls • At jambs of doors and window openings | | IS: 4326 CL 8.4.8 IS: 4326 CL 8.4.9 |
| 9 | Integration of prefab roofing / flooring elements through reinforced concrete screed | | IS: 4326 CL. 9.1.4 |
| 10 | Horizontal bracings in pitched truss • In horizontal plane at the level ofties • In the slopes ofpitched roofs | |
Notes:
-
Information in item 6 should be given on separate A4 sized sheets for all walls with large number of openings
-
IP. indicated “Information Provided”
TP indicates “Information to be provided”
NA indicates “Not applicable”
Tick mark one box.
APPENDIX-B (continued)
| Part 3 Reinforced concrete framed buildings | Part 3 Reinforced concrete framed buildings | Part 3 Reinforced concrete framed buildings | Part 3 Reinforced concrete framed buildings |
| S No. | Description | Information | Notes |
| 1 | Type ofbuilding • Regular frames • Regular frames with shear walls • Irregular frames • Irregular frames with shear walls • Soft storey | IS: 1893 CL. 7.1 | |
| 2 | Number ofbasements | ||
| 3 | Number of floors including ground floor | ||
| 4 | Horizontal floor system • Beams and slabs • Waffles • Ribbed floor • Flat slab with drops • Flat plate without drops | ||
| 5 | Soil Data • Type ofsoil • Recommended type offoundation - Independent footings - Raft -Piles • Recommended bearing capacity of soil • Recommended, type, length, diameter and load capacity ofpiles • Depth ofwater table • Chemical analysis ofground water • Chemical analysis ofsoil | IS: 1498 | |
| 6 | Foundations • Depth below ground level • Type Independent Interconnected Raft Piles | ||
| 7 | System ofinterconnecting foundations • Plinth beams • Foundation beans | IS: 1893 Cl.7.12.1 | |
| 8 | Grades of concrete used in different parts ofbuilding | ||
| 9 | Method ofanalysis used | ||
| 10 | Computer software used | ||
| 11 | Torsion included | IS: 1893 CL. 7.9 | |
| 12 | Base shear a. Based on approximate fundamental period b. Based on dynamic analysis c. Ratio ofa/b | IS: 1893 CL. 7.5.3 | |
| 13 | Distribution of seismic forces along the height ofthe building | IS: 1893 CL. 7.7 (provide sketch) | |
| 14 | The column of soft ground storey specially designed | IS: 1893 CL. 7.10 | |
| 15 | Clear minimum cover provided in • Footing • Column • Beams SlabsWalls | IS: 456 CL. 26.4 | |
| 16 | Ductile detailing of RC frameType of reinforced usedMinimum dimension of beansMinimum dimension of columnsMinimum percentage of reinforcement of beans at any cross sectionMaximum percentage of reinforcement at any section of beamSpacing of transverse reinforcement in 2-d length of beams near the ends.Ratio of capacity of beams in shear to capacity of beams in flexureMaximum percentage of reinforcement in columnConfining stirrups near ends of columns and in beam-column jointsa. Diameterb. SpacingRatio of shear capacity of columns to maximum seismic shear in the storey |
General Notes
-
A certificate to the effect that this report will be completed and submitted at least one month before commencement of construction shall be submitted with the application for Building Development Permission.
-
In addition to the completed report following additional information shall be submitted, at the latest, one month before commencement of construction.
2.1. Foundations
2.1.1 In case raft foundation has been adopted indicate K value used for analysis of the raft.
2.1.2 In case pile foundations have been used give full particulars of the piles, type, dia, length, capacity
2.1.3 In case of high water table indicate system of countering water pressure, and indicate the existing water table, and that assumed to design foundations.
2.2. Idealization for Earthquake analysis.
2.2.1. In case of a composite system of shear walls and rigid frames, give distribution of base shear in the two systems on the basis of analysis and that used for design of each system
2.2.2 Indicate the idealization of frames and shear walls adopted in the analysis with the help of sketches
2.3. Submit framing plans of each floor
2.4. In case of basements, indicate the system used to contain earth pressures.
APPENDIX-B (continued)
| Part 4 Buildings in structural steel | Part 4 Buildings in structural steel | Part 4 Buildings in structural steel | Part 4 Buildings in structural steel |
| 1 | Adopted method ofDesign | Simple Semi-rigid Rigid | IS: 00; CL. 3.4.4 IS: 800; CL. 3.4.5 IS: 800; CL 3.4.6 |
| 2 | Design based on | Elastic analysis Plastic analysis | IS: 00; Section-9 SP: 6(6) |
| 3 | Floor construction | Composite Non composite Boarded | |
| 4 | Roofconstruction | Composite Non-composite Metal Any other | |
| 5 | Horizontal force resisting system adopted | Frames Braced frames Frames and shear walls | Note: Seismic force As per IS:1893 would depend on system |
| 6 | Slenderness ratios maintained | Members defined in Table3.1,IS: 800 | IS: 800; CL. 3.7 |
| 7 | Member of deflection limited to | Beams, Rafters Crane Girders Purlins Top ofcolumns | IS: 800; CL. 3.13 |
| 8 | Structural members | Encased in concrete Not encased | IS: 800; Section-10 |
| 9 |