For any building construction work under the jurisdiction of these bye-laws, structural design/retrofitting shall only be carried out by a Structural Engineer on Record (SER) or Structural Design Agency on Record (SDAR). Proof checking of various designs/reports shall be carried out by the Authority as per Table-VI wherever applicable.
Generally, the structural design of foundations, elements of masonry, timber, plain concrete, reinforced concrete, pre-stressed concrete and structural steel shall conform to the provisions of part VI Structural Design Section-1 Loads, Section-2 foundation, Section-3 wood, Section-4 Masonry, Section-5 Concrete & Section-6 Steel of National Building Code of India (NBC), taking into consideration the Indian Standards as given below.
27.1 For General Structural Safety:
i) IS: 456:2000”Code of Practice for Plain and Reinforced Concrete
ii) IS: 800-1984 “Code of Practice for General construction in Steel
iii) IS: 801-2975 “Code of Practice for Use of Cold formal Light Gauge Steel Structural Members in General Building Construction
iv) IS 875 (Part 2): 1987 Design Loads (other than earthquake) for buildings and structures Part 2 Imposed Loads
v) IS 875 (Part 3): 1987 Design Loads (other than earthquake) for buildings and structures Part 3 Wind Loads
vi) IS 875 (Part 4): 1987 Design Loads (other than earthquake) for buildings and structures Part 4 Snow Loads
vii) IS 875 (Part 5): 1987 Design Loads (other than earthquake) for buildings and structures Part 5 special Loads and Load Combination
viii) IS: 883:1966 “Code of Practice for Design Structural Timber in Building
ix) IS: 1904:1987 “Code of Practice for Structural Safety of Buildings: foundation”
x) IS: 190:1987 “Code of Practice for Structural Safety of Buildings: Masonry Walls
xi) IS: 2911 (Part I): Section 1: 1979 “Code of Practice for Design and Construction of Pile Foundation Section 1
Part 1: Section 2 Based Cast-in-situ Piles Part 1: Section 3 Driven Pre-cast concrete Piles Part 1: Section 4 Based Pre-cast Concrete Piles Part 2: Timber Piles Part 3: Under Reamed Piles Part 4: Load Test on Piles
27.2 For Cyclone/Wind Storm Protection:
xii) IS: 875 (3)-1987 “code of Practice for Design Loads (other than earthquake) for Buildings and Structures, Part 3, Wind Loads”
xiii) Guidelines (Based on IS 875 (3)-1987) for improving the Cyclonic Resistance of Low rise houses and other building
27.3 For Earthquake Protection:
xiv) IS: 1893-2002 “Criteria for Earthquake Resistant Design of Structures (Fifth Revision)’
xv) IS: 13920-1993 “Ductile Detailing of Reinforced Concrete Structures subjected to Seismic forces-Code of Practice”
xvi) IS: 4326-1993 “Earthquake Resistant Design and Construction of Buildings-Code of Practice (Second Revision)”
xvii) IS: 13828-1993 “Improving Earthquake Resistant of Low Strength Masonry Buildings-Guidelines”
xviii) IS: 13827-1993 “Improving Earthquake Resistant of Earthen Buildings-Guidelines”
xix) IS: 13935-1993 “Repair and Seismic Strengthening of Buildings-Guidelines”
27.4 For Protection of Landslide Hazard:
xx) IS: 14458 (Part 1): 1998 Guidelines for retaining wall for hill area: Part 1 Selection of type wall.
xxi) IS: 14458 (Part 2): 1997 Guidelines for retaining wall for hill area: Part 2 Design of retaining/breast wall.
xxii) IS: 14458 (Part 3): 1998 Guidelines for retaining wall for hill area: Part 3 Construction of dry stone walls
xxiii) IS: 14496 (Part 2): 1998 guidelines for preparation of landslide-Hazard zonation maps in mountains terrains: Part 2 Macro-zonation.
Note: Whenever an Indian Standard including those referred in the National Building Code or the Indian National Building Code is referred; the latest revision of the same shall be followed except specific criteria, if any, mentioned above against that code
28. Structural Design Basis Report:
In compliance of the design with the above Indian Standard, the Structural Engineer on Record will submit a structural design basis report in the format given in Appendix-B covering the essential safety requirements specified in the Standard.
29. Seismic Strengthening/Retrofitting:
Prior to seismic strengthening/retrofitting of any existing structure, evaluation of the existing structure as regards vulnerability in the specified wind/seismic hazard zone shall be carried out by a Registered Structural Engineer/Registered Structural Design Agency. If as per the evaluation of the Registered Structural Engineer/Registered Structural Design Agency, the seismic resistance is assessed to be less than the specified minimum seismic resistance as given in the note below, action will be initiated to carry out the upgrading of the seismic resistance of the building as per applicable standard guidelines.
Note: (a) for masonry buildings reference is to be made to IS:4326 and IS: 13935 and (b) for concrete buildings and structures reference to be made to BIS code on evaluation and seismic strengthening for retrofitting of RCC buildings under preparation at present.
30. Review of Structural Design:
(i) The Competent Authority shall create a Structural Design Review Panel (SDRP) consisting of Senior Structural Design Engineers on Record and Structural Design Agencies on Record, whose task will be to review and certify the design prepared by Structural Engineer on Record or Structural Design Agency on Record whenever referred by the competent authority.
(ii) The Reviewing Agency shall submit addendum to the certificate or a new certificate in case of subsequent changes in structural design
(iii) Table-VI Gives requirements of SDRP for structures of different complexities.
TABLE-VI
PROOF CHECKING REQUIREMENTS FOR STRUCTURAL DESIGN