44.1 Industrial Buildings (factories, W Orkshops ETC.)
44.1.1. The relevant provisions contained in the Factory Act. 1948 shall apply for the construction of factory buildings. The minimum internal height of workrooms shall not be less than 4.5 mt. measured from the floor level to the lowest point in the ceiling provided that this bye-law shall not apply to room intended for storage, godowns and the like purposes but only in rooms occupied by workers for purposes of manufacture.
In case of small factories, employing less than 50 workers for purposes of manufacturing and carrying on a class of manufacturing covered under the flatted factories and service industries, the Authority may allow minimum height upto 3.60m.
44.1.2. Requirements of water supply, drainage and sanitary installation shall be as per National Building Code 2005 but in no case less than 1 W.C. and one urinal shall be permitted.
44.1.3. (i) Each working room shall be provided with adequate number of exits not less than two in number.
(ii) No exit shall be less than 1.20 m in width and 2.10 m in height and doors of such exit shall be so arrange that it can be opened easily from inside.
44.1.4. No staircase, lobby corridors or passage shall be less than 1.20 m in width.
44.1.5. There shall be provided at all time for each person employed in any room of factory at least 3.50 sq. m of the floor space exclusive of that occupied by the machinery and a breathing space of at least 15 cum. (Further the provision of part VIII section 1 lighting and ventilation of National Building code of India shall be followed).
44.1.6. The effluent from industries (industrial and biological in nature) shall be treated and shall be of quality to the satisfaction of the concerned local bodies before letting out the same into a watercourse or municipal drain.
45. EDUCATIONAL BUILDING (SCHOOL/COLLEGES)
45.1. No basement or cellar room shall be designed, constructed, altered, converted or used for the purpose of study or instructions.
45.2. The minimum size of a cellar room, study room or room used for purposes of instruction shall be 5.50m x 4.50m and no part of such room shall be distant more than 7.50m from an external wall abutting on the requisite open space. Every such room shall have minimum ventilation to the extent of 1/5th of its floor area.
45.3. A minimum of 1.00 sq. m of net floor space per student shall be provided. A central shall will not be counted in the accommodation, nor will a class room for cookery, laundry, manual instruction, drawing or science. The number of students in such building shall be calculated on this basis for the purpose of this clause.
45.4. Every assembly room, gymnasium shall have a minimum clear height of 3.60 m except under a girder which may project 0.60 m below the required ceiling height. A clear internal height under balcony or a girder shall not be less than 3.00 m A minimum room height for classroom in all schools and other institutions shall not be less than 3.00 m. The minimum head room under beams shall be 2.75 m.
45.5. Exit requirements shall conform to National Building Code 2005. No door shall be less than 1.20 m in width and 2.20 m in height.
45.6. Requirement of water supply, drainage and sanitary installation shall conform to National Building Code 2005.
- SPECIAL BUILDINGS In addition to the requirements specified under Building byelaws, the following byelaws shall also be applicable.
46.1. Minimum Requirements: The following requirement shall be provided:
46.1.1. The aggregate area of foyer exclusive of all passages shall be provided at every sitting-level at the rate of 0.1 sq.m per seat at that level, subject to minimum foyer width of 4.50 m.
46.1.2. Entry and exit passages of minimum 3 meters width shall be provided.
46.1.3. Water-room and snack-bar shall be provided.
46.1.4. The booking-office shall always be so located that intending purchasers of tickets does not have to queue up in open space.
46.2. Plinth: The plinth shall be measured at the foyer level and it shall not be less than 0.45 m.
46.3. Corridor: No landing, lobby, corridor or passage, not being an internal passage between and/or across rows of seats, intended for use as an exit; shall be less than 3m in width and there shall be no recess or projections in the walls of such passages or corridors within 1.80m of the ground.
46.4. Doors: The auditorium doors shall be provided at the rate of not less than one door of a dimension of 1.50 m in width and 2.10 m in clear height for every 150 seats or part thereof. All outside doors for the use of the public shall be made to open outwards and in such manner that when opened, they shall not obstruct any gangway, passage, stairway or landing. These doors shall be provided in such a way that they open in aisles or cross-aisles provided under these byelaws.
46.5. Balcony, its height, floor of an auditorium and arrangement of seats:
46.5.1. The height of the bottom balcony of the gallery shall be less than 3m from the floor of the auditorium.
46.5.2. The clear distance between the backs of two successive rows shall not be less than 1m. But for seats with rocking backs it may be 0.90m.
46.5.3. The minimum width of balcony steps shall be 0.80m provided that for the front and rear steps this distance shall be 0.90m.
46.5.4. The minimum height of the roof or ceiling at the highest steps of the balcony shall be 3.00m and at no place the distance between the nodding and the lowest projection ray shall be less than 2.40m.
46.5.5. The minimum width of the seat shall be 0.50m provided that 25 percent of the total seats may permit upto the width of 0.45m to adjust the staggering of the seats. The width of the seats shall be measured from centre of hand rails or arm rests.
46.6. Aisles: Clear aisles not less than 1.20m in width shall be formed at right angles to the line of seating in such number and manner that no seat shall be more than 3.80m away from any aisles measured in the line of seating. Where all these aisles do not directly meet the exit doors, cross aisles shall be provided in such number and manner that no row of seats shall be more than 7 meters away from cross-aisles. The width of cross aisles shall be 1.20m provided further that in computing the number of cross-aisles, the door connecting the aisles with foyer shall be considered as cross-aisles.
Explanation: The first cross-aisles in such a case shall be provided after the fourteen rows from the door.
(i) Sanitary Accommodations:
(ii) Water closet at the rate one for 100 seats or part thereof and urinals at the rate of two for 75 seats or part thereof, at each seating level shall be provided.
(iii) One wash-basin for every 200 seats or part thereof shall be provided.
(iv) The above conveniences shall be suitably apportioned between two sexes.
(v) Such water-closet and urinals shall be in accessible location and shall be provided with signs plainly indicating their purpose and the sex for which they are meant.
46.7. Visibility requirement:
46.7.1. The seat nearest to the screen shall not be nearer than the effective width of the normal picture (ratio 1:1.33). This distance shall be ¾ in case of cinema scope and other wide angles techniques and one half in case of 70 mm presentations.
46.7.2. The elevation of the balcony seats shall be such that line of sight is not inclined more than 30Oto the horizontal.
46.7.3. The seats should preferably be staggered side-ways in relation to those in front, so that a spectator in any rows is not looking directly over the head of the person immediately in front of him.
46.7.4. The position and height of the screen shall be regulated in such a way that the maximum angle of the line of vision from the front seat to the top of the screen shall not exceed 50.
46.8. Ventilation : Every auditorium shall be lighted and ventilated by doors, ventilators and windows abutting on an interior or exterior open space which shall not be less than 1/5th of the total floor area provided that if exhaust fans are installed or if the auditorium is air-conditioned, the requirement of this clause may be suitably relaxed.
46.9. Minimum Requirement of Stairs:
46.9.1. Except where otherwise provided under these Regulations/bye-laws the minimum clear width of all the stairs shall be 1.50m.
46.9.2. No stair-case shall have a flight of more than 15 steps or less than 3 steps and width of the landing between such flights shall be of the same width of the stair-case. The tread of the step shall not be less than 30 cms. The riser shall not be higher than 10 cms.
46.9.3. No space less than 2.40m in height shall be allowed under the floor of auditorium.
46.9.4. Except for a double-decker-cinema or theatre, the access to the auditorium from the ground floor, if it is on upper floor or on stilts shall be provided by not less than three stairs: two of which shall be exit stairs. The clear width of these next stairs shall not be less than 2m.
46.9.5. The access to balcony floor from auditorium floor shall be provided by not less than three stairs, two of which shall be exit stairs provided that if one exit stair is to be provided instead of two, its minimum width shall be 2.40m.
46.9.6 In case of double-decker cinema or theatre:
The access to upper class auditorium from ground floor shall be provided by at least three stairs out of which two shall be exit stairs with minimum clear width of 2 Mts.
The access to lower class auditorium from ground floor shall be provided by at least two stairs, one of which shall be exit stair.
46.10. No permission shall be given for converting existing air-conditioned cinema theatre into non-air-conditioned cinema theatre.
Section E
Facilities for Persons with Disabilities
These byelaws are applicable to all private and public buildings (proposed and existing) used by the public and shall not be restricted to a single floor or storey but shall allow free & full accessibility to the entire building.
- Definitions:
48.1 Non-Ambulatory Disabilities: Impairment that regardless of cause or manifestation, for all practical purpose, confines individuals to wheelchairs
48.2 Semi-Ambulatory Disabilities: Impairments that cause individuals with difficulty or insecurity, individuals using braces or crutches, arthritis, and those with pulmonary and cardiac ills may be semi-ambulatory.
48.3 Hearing Disabilities: Deafness or hearing handicaps that might make individual insecure in public area because he is unable to communicate or hear warning signals.
48.4 Sight Disabilities: Total blindness or impairments affecting sight to the extent that the individuals functioning in public areas in insecure or exposed to danger.
48.5 Wheel Chair: Chair used by disabled people for mobility. The standard size of the wheel chair shall be taken as 1050mm x 750mm.
-
Guiding/Warning Floor Materials: The floor materials to guide or warn the visually impaired persons with a change of colour or material with different texture and easily distinguishable from the rest of the surrounding floor materials is called guiding warning floor materials. The materials with different texture give audible signals with sensory warning when a person moves on this surface with walking stick. It is meant to give the directional effect or warn a person when at critical places.
-
Visual Signage: Appropriate identification of specific facilities within a building for the persons with disabilities should be done with proper signage. Visually impaired persons make use of other senses such as hearing and touch to compensate for the lack of vision, whereas visual signals benefit those with hearing disabilities.
Signs should be designed and located so that they are easily readable by using suitable letter size (not less than 20 mm) high. For visually impaired persons, information board in Braille on the wall at a suitable height and it should be possible to approach them closely. To ensure safe walking there should not be any protruding sign which creates construction in walking. Public address system may also be provided in busy public areas.
The symbols/information/should be in contrasting colour and properly illuminated because people with limited vision may be able to differentiate amongst primary colours.
- Site Planning: To accommodate the persons with disabilities and elderly people each building and its site should be planned and designed as an integral unit from the very beginning of the design process.
51.1 Walks and Paths: Walking should be smooth, hard level surface suitable for walking and wheeling. The minimum walkway width should be 1200 mm. and for moderate two ways traffic should be 1650 mm -1800 mm. Longitudinal walk gradient should be 3 to 5 % (30 mm to 0.50 mm in meter). When walk exceed 60 meter in length it is desirable to provide rest area adjacent to walk at convenient intervals with space for bench seats. For comfort the seat should be between 350 mm to 425 heights but not over 450 mm. Texture change in walkways adjacent to sitting will be desirable for blind persons.