The following appurtenant structures shall not be included in the height of the building unless the aggregate area of such structures, including pent-houses, exceeds one-third of the area of the roof of building upon which they are erected:
a) Roof tanks and their supports (with support height not exceeding 1 m);
b) Ventilating, air-conditioning, lift rooms and similar service equipment;
c) Stair cover (MUMTY) not exceeding 3 m in height; and
d) Chimneys, parapet walls and architectural features not exceeding 1.2 m in height.
Licensed Architect/Engineer/Town Planner/Firm etc’ - Means a qualified Architect/Engineer/Town Planner/Firm etc who has been given license by Meghalaya Urban Development Authority.
Note: Presently, the legislation for profession of architecture is applicable in the country in the form of Architects Act 1972. Whereas, for other professions and professionals like engineers, developers/promoters for taking up any project there is no legislative framework available/applicable in the country.
In the absence of any such legislation, the appropriate qualifications, service conditions, professional fees and charges in the engineering profession etc are varying and are not based on any uniform formula. Keeping the above in view, the qualifications/responsibilities and duties of Professionals are given in Appendix A.
2.25. ‘Ledge’: - Means a shelf-like projection, supported in any manner whatsoever, except by means or vertical supports within a room itself but not having projection wider than one meter.
2.26. ‘Loft’: - Means a structure providing an intermediate storage space between two floors or a residential space in a pitched roof, above normal floor level with a maximum height of 1.5 meter and which is used for storage purpose.
2.27. ‘Mezzanine floor’: - Means an intermediate floor between any two floors above ground in all type of buildings provided the same is counted as part of total permissible floor area ratio and height of the building. Mezzanine floor may be permitted with the minimum height of 3.0 mt.
2.28. “Multi-storeyed Building or High Rise Building” – A building above 4 storeys, and/or a building exceeding 15 meters or more in height. However, chimneys, cooling towers, boiler rooms/lift machine rooms, cold storage and other non working areas in case of industrial buildings and water tanks, and architectural features in respect of other buildings may be permitted as a non
high rise building. Buildings less than 15 meters including stilt/basement/parking floors stand excluded from the definition of high rise buildings.
2.29. ‘Open Space’: - Means an area forming an integral part of the plot, left open to the sky.
2.30. ‘Owner’: - Means a person who receives the rent for use of land or building, or would be entitled to do so if they were let.
2.31. ‘Occupancy’: - Means the change of function or use of the building.
2.32. ‘Parapet’: - Means a low wall or railing built along the edge of a roof or floor not less than 90cm in height.
2.33. ‘Plinth’: - Means the portion of a structure between the level of the ground and the floor immediately above the ground.
2.34. ‘Porch or Portico’: - Means a roof cover supported on pillars or cantilevered for the purpose of pedestrian or vehicular approach to a building.
2.35 ‘Sanctioned Plan’:- Means the set of plans and specification submitted under byelaw 4 in connection with a building and duly approved and sanctioned by the Authority.
2.36. ‘Set back Line’: - Means the open space from the proposed building envelop to the plot boundaries and laid down in each case by the Authority beyond which nothing can be constructed towards the boundaries.
2.37. ‘Site or Plot’: - Means a piece of land enclosed by the boundaries.
2.38. ‘Storey’: - Means the portion of building included between the surface of any floor and the surface of the floor next above it.
2.39. ‘To erect’: - Means
a) To erect a new building on any site whether previously built upon or not;
b) To re-erect any building of which portion have been pulled down, burnt or destroyed;
c) Conversion from one occupancy to another; and
d) To carry out alterations.
2.40. ‘Materials Alteration’: - Means a change of use in building materials in any existing building.
2.41. ‘Total floor area’: - Means the area of all floors of building including habitable, basement and mezzanine floor.
2.42. ‘Travel distance’: - Means the distance an occupant has to travel to reach the exit.
2.43. ‘Verandah’: - A covered area with at least one side open to the outside.
2.44. ‘Natural Hazard’ - Means the probability of occurrence, within a specific period of time in a given area, of a potentially damaging natural phenomenon.
2.45 ‘Natural Hazard Prone Areas’ - Means areas likely to have moderate to high intensity of earthquake or cyclonic storm, or significant flood flow or inundation or land slides/mud flows/avalanches, or one or more of these hazards.
Note: Moderate to very high damage risk zones of earthquakes are given as in Seismic Zones III, IV and V specified in IS:1893; moderate to very high damage risk zones of cyclones are those areas along the sea coast of India prone to having wind velocities of 39 m/s or more as specified in IS:875(Part 3;) and flood prone areas in river plains (Unprotected and protected) are indicated in the Flood Atlas of India prepared by the Central Water Commission, besides, other areas can be flooded under conditions of heavy intensity rains, inundation in depressions, back flow in drains, inadequate drainage, etc. as to be identified through local surveys in the development plan of the area and landslide prone areas as to be identified by State Government.
2.46 ‘Lifeline Building’ – Means those buildings which are of post earthquake importance such as hospital building, power house building, telephone exchange building and the like.
2.47. ‘Special Building’ – Means those buildings with large scale activities at a time such as Hotel of 4 star category &above, Public Institutions, Hospitals, Shopping malls with Multiplexes, I.C.T./ BPO’s, Educational Institutions having a minimum plot area of 6000 sq.m and a mininmum plinth area of 3000 sq.m.
2.48. ‘Retrofitting’ - Means upgrading the strength of an unsafe building by using suitable engineering techniques.
2.49. ‘Quality Control’ - Means construction quality and to control variation in the material properties and structural adequacy. In case of concrete, it is the control of accuracy of all operations, which affect the consistency, and strength of concrete, batching, mixing, transporting, placing, curing and testing.
2.50. ‘Quality Audit’ - Means a requirement for an independent assessment by a third party, of the quality and seismic or cyclone resistant features of all the high-rise buildings in earthquake zone V. The quality audit report shall consists of conformance or non-conformance of structures with the technical specifications for earthquake and cyclone resistance and to suggest remedies/rectification if any.
2.51. ‘Quality Assurance’ – Means that all planned and systematic actions necessary to ensure that the final product i.e. structure or structural elements, will perform satisfactorily in service life.
2.52. ‘Compliance’ – Means a verification of the properties of construction materials based on test data and verification of the strength and structural adequacy for various components of buildings and structures.
2.53. ‘Non-Structural Component’ - Those components of buildings, which do not contribute to the structural stability such as infill walls in RCC frame buildings, glass panes, claddings, parapet walls, chimneys etc.
4.1. The application for building permission shall be accompanied by documentary evidence of plot ownership, the site plan, the building plan, general specification, Seismic certificate, Structural Design Basis Report and drawings etc.
4.1.1. Site Plan: - Shall be drawn to a scale not less than 1:200 and shall show
(a) Boundaries of the plot with dimensions and contour intervals.
(b) Position of the plot in relation to the neighboring streets.
(c) Position of the building proposal in relation to North direction of the site.
(d) Plot area, plot coverage and F.A.R.
(e) Sewerage and surface drains, position and sizes of septic tank and soak pit in cubic dimensions of length, breath and depth.
(f) Any other particulars as prescribed by the Authority in the case of major proposals.
4.1.2. Building Plans, Site Plans, Section and Elevations accompanying the application shall be drawn to a scale not less than 1:100 and shall.
(i) Include floor plans of all floors, indicate the use of each floor of the building.
(ii) Shall indicate height of the building and parapet.
(iii) Give dimensions of the projected portions.
(iv) Include a roof plan indicating drainage and roof slope in case of building proposal having pitch roof(s).
(v) Specify total floor area of the building.
4.1.3. Building Plans for Special Buildings: For Special buildings, the building sanction shall be done in two stages.