- Mezzanine floor.—(1) The built-up area of mezzanine floor shall not exceed one third area of the main floor or room accommodating the mezzanine floor.
(2) The clear headroom beneath and above the mezzanine floor shall not be less than 2.2 metres.
-
Height of room.— The height of room intended for human entry in a building other than residential occupancy and livestock/poultry farm shall not be less than 3 metres: Provided that in the case of air conditioned rooms it shall not be less than 2.4 metres.
-
Sanitation Facilities:—
(1) Size of bathroom and latrine.—
(1) The area of bathroom shall not be less than 1.50 sq. metres with either side not less than1.1m, area of a latrine shall not be less than 1.10 sq. metres with one side not less than 1.0 metre:
Provided that the area of combined bathroom and latrine shall be not less than 2.2 sq. metres with one side not less than 1. 1 metres:
(2) The height of bathroom or latrine shall be not less than 2.20metres.
(2) Water closet.—Every building above 50 square metres of build up area shall be provided with at least one water closet.