Regulations for Collection of Rain Water
- The collection of rain water from the roof tops of the buildings shall be compulsory where the Himachal Pradesh Town and Country Planning Act, 1977 (Act No. 12 of 1977) is in operation in the State as under :-
(a) For all the buildings existing or proposed for construction in future; and
(b) The Guidelines for capturing, storage, integration and distribution of rain water shall be as under:-
(i) The Rain Water Harvesting Structures are allowed to be constructed in set backs below ground level. If the storage is desired at any level above ground level, it has to be away from set backs within the permitted covered area.
(ii) The community Rain Water Harvesting Structure shall also be permissible.
(iii) Proper system for rain water capturing, storage as well as integration and distribution shall be ensured.
(iv) The stored rain water shall be utilized regularly for non-drinking usages including fire fighting, landscaping, gardening apart from domestic usages.
(v) No water supply connection shall be given to any building till Rain Water Harvesting System is put in place and subsequently operationalised.
(vi) The minimum capacity of Rain Water Harvesting Structure shall be worked out @ 20 Liters per square Metre of the roof top area.
(vii) Violator shall be liable for disconnection of Public Water Supply connection.
(viii) The owners of existing buildings without Rain Water Harvesting System shall have to install Rain Water Harvesting System within eighteen months after coming into the operation of these Regulations.