1 Site Planning:
Every public and semi-public building shall have at least one access to main entrance/*exitto the disabled, which shall be indicated by proper signage. This entrance shall have approach through a ramp together with stepped entry. The ramp should have a landing after 9 M run and in front of the doorway. Minimum size of landing shall be 1000 mm x 2000 mm.
2 Access Path/Walkway:
Access path from plot entry and surface parking to building entrance shall be minimum of 1800 mm wide having even surface without any step. The slope, if any shall not be greater than 5%. Selection of floor material shall be made suitably to attract or to guide visually impaired persons (limited to floor material whose colour texture is conspicuously different from that of the surrounding floor material or the material that emit different sound to guide visually impaired persons). Finishes shall have a non-slip surface with texture traversable by a wheel chair. Curbs wherever provided should blend to common level.
3 Parking Provision:
(a) Surface parking for two equivalent car spaces shall have to be provided near entrance with maximum travel distance of 30 M from building entrance. Width of parking bay shall be minimum 3.60 M.
(b) Guiding floor materials shall be provided or a device which guides visually impaired persons with audible signals or other devices which serves the same purpose shall be provided.
4 Approach to Plinth Level:
(a) Ramp shall be provided with non-slip material to enter the building. Minimum clear width of ramp shall be 1800 mm with maximum gradient of 1:12 between top and bottom of the ramp. Length of ramps shall not exceed 9.00 M having 800 mm high handrail on both sides extending 300 mm beyond the ramp. Minimum gap from the adjacent wall to the handrail shall be 50 mm.
(b) For stepped approach, size of tread shall not be less than 300 mm and maximum riser shall be 150 mm. Provision of 800 mm high handrails on both sides of the stepped approach similar to the ramped approach shall be provided.
- Entrance Door: Minimum clear opening for the entrance door shall be 1000 mm.
6 Corridor connecting the Entrance/Exit:
The corridor connecting the entrance/exit for handicapped, leading directly outdoors to a place where information concerning the overall views of the specific building can be provided to visually impaired persons either by a person or signs shall be provided as follows:-
* As amended vide Himachal Pradesh Town and Country Planning (Amendment), Rules 2016
(a) Guiding floor materials shall be provided or devices that emit sound to guide visually impaired persons.
(b) The minimum width shall be 1500 mm.
(c) In case there is a difference of level, slope ways shall be provided with a gradient of 1:12.
(d) Handrails shall be provided for ramps/slope ways.
7 Lift:
For the buildings with more than 15.00 M in height, one lift shall be provided for the wheel chair user with the following clear dimensions:-
(a) Clear internal depth 1100 mm
(b) Clear internal width 2000 mm
(c) Entrance door width 910 mm
A handrail not less than 600 mm long at 900 mm above floor level shall be fixed adjacent to the control panel. The lift lobby shall be of an inside measurement of 1800 mm x 2000 mm or more. Operational details of lift shall conform to the National Building Code of India.
- Toilets: One special toilet in a set of a toilets shall be provided for use of handicapped with following specifications:-
(a) Provision of wash basin near the entrance.
(b) The minimum size shall be 1500 mm x 750 mm.
(c) Minimum clear opening of the door shall be 900 mm and the door shall be swinging/sliding type.
(d) Suitable arrangements for vertical/horizontal handrails with 50 mm clearance from wall shall be made in the toilet.
(e) The Water Closet (WC) seat shall be 500 mm from the floor.
9 Refuge Area:
Refuge area shall have to be provided at the fire protected stair landing on each floor having doorways with clear opening width of 900 mm that can safely hold one or two wheelchairs. The alarm switch should be installed between 900 mm and 1200 mm from the floor level.