1 Slope
Buildings of Information Technology (IT) Park shall be allowed upto 3 0 0 slope. The infrastructural services including roads shall be developed in accordance with the slope of the area.
2 Land Use structure of complex
| Sr. No. | Land Use Structure | Maximum limit |
|---|---|---|
| 1. | Total Covered Area (i) IT related activities (ii) Commercial (iii) Recreational (Indoor) (iv) Residential | 50%22% to 44% 1% to 5% 1% to 3% 9% to 15 % |
| 2. | Parks and Tot Lots | 8% to 12% |
| 3. | Area under Traffic and Transportation | 16% to 20% |
| 4. | Area under Set Backs and other Open Spaces | 20% to 24% |
3 Means of Access
(i) The access to the site of IT Park area shall not be less than 5.00 M wide.
(ii) Provisions of internal roads shall be as under:-
| Sr.No. | Width | Length |
|---|---|---|
| 1. | 9.00 M | Up to 1000.00 M |
| 2. | 12.00 M | Above 1000.00 M |
4 Parking Provision
- Residential
= @ 1.00 car space per 7 5 M 2 floor area
- Commercial
= @ 1.50 car space per 7 5 M 2 floor area
- Office Use
=@ 1.25 car space per 75 M2floor area
- Hardware Manufacturing Unit
= @ 1.00 car space per 60 M 2 floor area
- Software development/ITES
= @ 1.00 car space per 40 M2floor area
Maximum height of parking floor shall be 3.00 M including depth of beam below the ceiling of the slab.
5 Maximum Floor Area Ratio (FAR)
Maximum Floor Area Ratio (FAR) shall be 1.75.
6 Maximum height of buildings
Maximum height of buildings for IT and related activities shall be 21.00 M.
7 Set Backs
(i) Block to Block distance shall be 2 / 3 r d of average height of the Blocks.
(ii) Distance of structures from the adjoining properties and side Set Backs shall not be less than 1 / 3 r d of the height of the Blocks.
(iii) Minimum 3.00 M distance from internal roads shall have to be maintained.
8 Expansion Joints
The structures exceeding 45.00 M in length shall be divided by one or more expansion joints as per the Structural Design calculations.
9 Structural Stability
The Structural Stability provisions including Soil Investigation Report have to be strictly adhered, as enshrined in section 31-A of the Himachal Pradesh Town and Country Planning Act, 1977 (Act No. 12 of 1977) and under Rule 21 of the Himachal Pradesh Town and Country Planning Rules, 2014.
10 Environment and Health
(i) Proper air, light and ventilation to each dwelling unit shall have to be ensured. At least three hours sun may be available for each building during winters. In case of residential structures, kitchen and services shall have to be provided along the external walls. However, if the water closets and bath rooms are not opening to the front, sides, rear and interior open spaces, these shall open to the ventilation shaft. The maximum size of ventilation shaft shall be 4.00 M2 with minimum one dimension of 1.50 M.
(ii) The Developer shall ensure prior environmental clearance under the provisions of the Environment Protection Act, 1986 from the Competent Authority, besides consent of the Himachal Pradesh State Environment Protection and Pollution Control Board under the Water (Prevention and Control of Pollution) Act, 1974 and the Air (Prevention and Control of Pollution) Act, 1981.
11 Safety Measures
*(i) In case of buildings above 15.00 M height, No Objection Certificate from the Director of Fire Services or Chief Fire Officer, as the case may be, shall be required only at the completion stage.
(ii) The provision of stair cases shall be as per clause *“4.6.2” of Part-IV of the National Building Code of India i.e. minimum two stair cases for floor area of more than 500 M2. At least one of the stair case shall be on external wall of the buildings and shall open directly to the exterior. Width of stair case shall not be less than 3.00 M i.e. 1.50 M in each flight.
(iii) Provision for lift shall be optional upto 3 storeys and 1 parking floor. However, for more than 3 storeys and one parking floor, it shall be mandatory requirement. The Developer shall make provision of power back up for the lift and general lighting within and outside the building at his own cost.
(iv) Provision for proper Fire Hydrants shall have to be made in the Complex and the layout, showing position and location of the same. It shall be made available to the nearest Fire Office.
* As amended vide Himachal Pradesh Town and Country Planning (Fifth Amendment), Rules 2020
12 Potable Water Supply and Rain Water Harvesting
*(i) Water Availability Certificate from the Himachal Pradesh Irrigation and Public Health Department regarding availability of adequate water supply and viability of design of rain water harvesting structure shall have to be furnished.
(ii) Adequate provision for rain water harvesting structure, @ 20 Liters per M 2 of the roof top area, shall have to be made underground in the parks and open spaces and the same shall be used for the purposes other than drinking and cooking.
13 Parks and Tot Lots
Area under parks and tot lots shall have to be properly developed in regular shape by providing retaining walls, railings, plantation etc. and amidst the Blocks, proper landscaping of the IT Park area in accordance with the design shall be ensured by the Developer.
14 Existing trees and plantation
(i) No construction shall be allowed within a radius of 2.00 M from the existing tree and 5.00 M from the forest boundary measured from the circumference of an existing tree.
(ii) Plantation shall be ensured @ 125 trees per Hectare.
15 Distance from Natural drainage
Distance from the Highest Flood Level (HFL) along Rivers, Khuds and Nullahs shall be as delineated in the Interim Development Plans / Development Plans. In other areas, no construction shall be allowed in parcel of land prone to floods.
16 Distance from Roads
Minimum distance of structures from National Highways, State Highways, Himachal Pradesh Public Works Department (HPPWD)’s Scheduled roads, Bye-Passes and other District roads shall be 15.00 M.
17 Distance from Electric Lines
Adequate distance from the electric lines as per the requirement of Himachal Pradesh State Electricity Board Limited (HPSEB Ltd.) Rules shall have to be maintained.
18 Assessment of Power requirement
In case power requirement assessment exceeds 50 KW, proper space for installation of electric Transformer and Transmission Lines of 11 KV shall be provided in the layout plan. The proposed space is to be got verified from the concerned Officer of the HPSEB Ltd. and accordingly report shall have to be furnished.
19 Development of Infrastructure and its maintenance
(i) The Developer shall construct roads and drains, lay electric and sewerage lines and shall make provision for disposal of solid waste etc. Suitable site has to be reserved for placement of dumpers. The provision of services infrastructure shall be made through a duct to be constructed on the sides of the internal roads.
(ii) The Developer shall provide street light poles each at a distance of 30.00 M on either side of the roads.
(iii) The provision of community water reservoir has to be made in the Complex.
* As amended vide Himachal Pradesh Town and Country Planning (Fifth Amendment), Rules 2020
(iv) All the infrastructural services shall be maintained by the Developer, till such time when a Society is formed and got registered by the stakeholders and residents of the Complex or a Municipality or Gram Panchayat takes over the maintenance pursuits of the area.
20 Supervision
The registered Architect from the Council of Architecture and Structural Engineer, Graduate in Civil Engineering with 3 years experience in Structural Engineering and the Town Planner shall be competent for supervision of development of land as per provisions of Annexure-A of Part II of the National Building Code of India, 2005.
21 Integration
Proper integration of the IT park area shall have to be ensured with the surrounding uses and infrastructural provisions like roads, drainage, sewerage etc.
22 Preservation of local Heritage and Hill Architecture
As far as possible local Heritage and Hill Architecture imperatives shall have to be ensured and incorporated in the designs in terms of facades, sloping roof, windows, doors etc. in hilly areas.
- Other Regulations and instructions as issued by the Government from time to time shall be adhered strictly.