The following provisions shall be applicable where no specific mention is made, namely:-
-
Every plot should abut with path having 3.00 Meter width. In case the width is on lesser side, the applicant has to surrender land to make it 3.00 Metre wide.
-
The height of a building shall further be related to the width of abutting path:
For path less than 3.0M and non-vehicular 10 Metres
For path between 3.0M to 5.00M 15 Metres
-
Maximum acceptable slope for development shall be 45 degrees.
-
Maximum height of plinth level shall be 2.00 Meters.
-
One parking floor shall be mandatory wherever feasible. Maximum height of parking floor shall be 3.00 Metres for residential use and 4.00 Metres for other uses. Shear walls shall be constructed on all the three sides of parking floor, so that it does not behave as a soft storey.
-
In case, space as per requirement for parking is available in open, over and above the set backs, condition of parking floor shall not be insisted. The closed floors in a building at any level, if proposed and feasible for parking may be converted into parking floors. However, only one parking floor shall be exempt from Floor Area Ratio (FAR), subject to the height of building restriction and structural stability.
Though, one parking floor is mandatory yet second parking floor can be constructed which will be optional. Here too only one parking floor shall be exempt from Floor Area Ratio (FAR), subject to the height of building restriction and structural stability.
Fee for parking floor(s) shall have to be payable in all cases.
-
Every room used or intended to be used for the purpose of an office or for habitation in any building shall have a height of minimum 2.75 Meters and maximum 3.50 Meters measured from the surface of floor to lowest point of the ceiling (bottom of slab). The chimneys, elevators, poles, tanks and other projections not used for human occupancy may extend above the prescribed height limits. The cornices and window sills may also project into any required Set Backs.
-
Sloping roof shall be mandatory in hill areas (As per the URDPFI Guidelines, 2014 and National Building Code, 2005 hilly areas is any area above 600 m in height from mean sea level, or any area with average slope of 30°)which may be CGI, GI sheet or slate roof with facia.
(i) The roof shall be painted with post office red or forest green or natural roofing material such as slates. Height of sloping roof zero at eaves and maximum 2.75 Metres at centre shall be permissible. The Dormer at suitable distance on either side of the roof shall be permissible subject to the condition that the ridge of Dormer shall be below the ridge line of main roof.
(ii) Roof top @ 12 M2 per 1 Kilo Watt peak (KWp) shall be used for Solar Photovoltaic (PV) installations.