Regulations for Solar Passive Building Design
1 Scope
The Solar Passive Building Design shall be required in the following type of buildings:-
(i) All the Government and Semi-Government buildings.
(ii) Public and Semi-Public Institutions including Educational, Health, Community Centres, Banquet Halls, Inns and buildings of Autonomous Bodies.
(iii) Urban Local Bodies and Panchayati Raj Institutions.
(iv) Residential buildings in Urban and Urbanisable Areas.
(v) Residential Colonies and Apartments.
(vi) Commercial complexes and buildings related thereto including Hotels, Resorts, Lodges and Guest Houses.
(vii) Industrial buildings and complexes thereof.
(viii) Transport buildings such as Airport Terminals, Bus Terminals, Railway Stations etc.
(ix) New Townships.
2 Building Map
The map for the proposed building should accompany a statement giving detail of specifications of solar passive heating and cooling system, day lighting features, solar
photovoltaic panels, energy efficient and other renewal energy devices as shown in the drawing and proposed to be installed where required. Expected energy saving in the building should also be mentioned.
3 Site Selection
The site should preferably be selected on southern slopes or sunny side. Availability of sun shine duration during the winter months of December to March should also be mentioned.
4 Orientation
The longer axis of the building should preferably lie along east-west directions to trap maximum solar energy during winters.
5 Planning of Spaces
The main habitable spaces of a building may be planned and designed in such a manner, so that natural day light is available. The stair cases, garages, toilets and stores may be planned preferably on northern side. Minimum door and window openings on north side be proposed to avoid heat losses. In order to capture maximum heat in winters, maximum glazing be proposed on southern side. Glazing in proportion to total surface area of outer wall should not exceed more than 50% in mid-altitude regions i.e. 1500 M to 2200 M and not more than 70% in high altitude regions i.e. 2200 M and higher.
6 Integrating Solar Heating Systems in Building Designs
6.1 Passive solar heating systems like solar air heating, water heating, sun space, solar walls, space heating, green houses and solar trombe wall etc. shall be integrated in the building design, wherever possible on southern side, so as to allow maximum direct solar access to these systems.
6.2 The suitability of space heating systems to be installed or incorporated in the design of a solar passive building is to be decided by the registered Town Planner/Architect/Engineer/Designer/Solar Expert in accordance with building site, climate and space heating requirements.
7 Solar Photovoltaic Panel (SPV) for Lighting
Wherever possible and required, the solar photovoltaic panels may be integrated preferably in the building design for providing light in the building, emergency lighting and street lighting, so that use of electricity is minimized.
8 Solar Passive Cooling Design Features
The ventilation and Solar Passive cooling features may be incorporated wherever required as follows:
8.1 Cross Ventilation: Windows on opposite sides of rooms may be provided for proper circulation and ventilation of fresh and cool air in summers. Windows on southern side may be fixed with overhangs of adequate height and width to provide shade during the summers.
8.2 Colour and Shading: The external surface of the wall may be painted with white or light colours to reflect instant solar radiation.
8.3 Ground Embankments: Ground floor may be provided with earth berming upto a height of around 1.00 M for taking the advantage of constant temperature of the earth through out the year.
8.4 Outside Temperature: Outside temperature may be modified by landscaping.
9 Reducing Thermal Losses
The local building materials including stone, slate and mud may be utilized to meet the heating and cooling requirements by storing warmth and keeping the building cool.
10 Outer Wall Thickness
Outer walls of the building should be made atleast 0.23M thick or with cavity with air or with insulation for thermal comfort and to avoid the transfer of heat from outer environment to inner environment and vice-versa.
11 Installation of Solar assisted Water Heating System in Buildings
11.1 The capacity of the Solar hot water system is to be determined as per the requirement of particular building. The following building plans shall be submitted alongwith provision of solar water heating system.-
(a) Hospitals and Nursing Homes.
(b) Hotels, Lodges, Guest Houses, Group Housing or Apartments on an area of more than 1000 M2.
(c) Hostels of Schools, Colleges, Training Centres and other Institutions.
(d) Barracks of Police.
(e) Functional Buildings of public institutions like Airports, Bus Stands and Railway Stations.
(f) Community Centres, Banquet Halls and buildings for similar use.
*(g) Roof top @ 12 M2 per 1 Kilo Watt peak (KWp) shall be used for Solar Photovoltaic (PV) installations.
11.2 (a) New buildings should have open space on the roof top which receives direct sun light. The load bearing capacity of the roof should at least be 50 Kg. per M2. All new buildings of above categories must complete installation of solar water heating system before putting the same in use.
(b) Installation of solar assisted water heating systems in the existing building as given in Regulation 11.1 shall be required at the time of change of building use to above said categories, provided there is a system or installation, for supplying hot water.
11.3 Installation of solar assisted water heating systems shall conform to the Bureau of Indian Standards (BIS) specifications. The solar collectors used in the system shall have the Bureau of Indian Standards (BIS) certification mark.
11.4 All solar water heating systems may have an automatic electric backup system, so that the same is functional during cloudy or low / non-sunshine days.
11.5 Provision in the building design itself may be kept for an insulated pipeline from the roof top in the building to various distribution points where hot water or hot air is required.
11.5 The solar water heating system has to be integrated preferably in roof of the building, wherever possible, so that the panels become integral part of the roof. The solar air /water collectors/ green houses / sunspaces on the roof for receiving maximum solar radiation will be allowed.
* As amended vide Himachal Pradesh Town and Country Planning (Amendment), Rules 2016