Spaces excluded from FSI and Coverage Computation
1 The following shall not be counted towards FSI and plot coverage computation:
(1) Areas covered by stair-case rooms and lift rooms and passages thereto above the top most storey, architectural features, chimneys, elevated tanks (provided its height below the tank from the floor does not exceed 1.5 metre.) and WC (area not exceeding 10 sq.m)
(2) Staircase and lift rooms and passage thereto in the stilt parking floor
(3) Lift wells in all the floors
(4) Area of fire escape staircases and cantilever fire escape passages.
(5) Area of the basement floor / floors used for parking
(6) Area of the stilt parking floor provided its clear height (between lower floor and the bottom of the roof beam) does not exceed 3.0m and it is open on sides, and used for parking
(7) Area of structures exclusively for, accommodating machineries for water treatment plant and effluent treatment plant proposed with clearance from Tamil Nadu Pollution control Board,
(8) Areas covered by service ducts, and garbage shaft.
(9) Area of Balcony / Service verandah to an extent of 5 percent of each dwelling unit area in case of residential buildings and 5 percent of room area in the case of hotels and lodges.
(10) Porches /Canopies / porticos
(11) Service floor with height not exceeding 1.5 metres
(12) The following services and incidental structures necessary to the principal use subject to a maximum of 10 percent of the total floor area.
(a) Area of one office room not exceeding 15 sq.m for co-operative housing society or apartment/ building owners association in each block
(b) Servant's/drivers bath room and water closet (not exceeding 20 sq.m.) for each block in cases of special building, Group development, and Multi-storeyed Building at ground floor /stilt parking floor
(c) Gymnasium of 150sq.m in floor area
(d) Area covered by
(i) Metre room in Ground floor or stilt parking floor
(ii) Air-conditioning plant room in basement or ground floor
(iii) Electrical room (conforming to Annexure XXIV) in Ground floor or Stilt parking floor
(iv) Watchmen or caretaker booth/room in Ground floor / Stilt parking floor
(v) Pump room in Ground floor or stilt parking floor.
(vi) Generator room in basement floor or ground floor or stilt floor.
(vii) Lumber room in basement floor or ground floor.
(viii) AHU in all the floors.
(ix) Electrical /switch gear rooms in all the floors.
(e) Area of one room in ground floor of residential and commercial Multi-storeyed building, Special buildings, Group developments for separate letterboxes.