(A) Location of Multi Level Parking Lots
Structures exclusively for multi level parking shall abut on a road of minimum 7.2m in width where the height is upto 15.25m and road of minimum 18.0m in width where its height exceeds 15.25m. As proposed there will not be any FSI/coverage restriction for such multi level parking lots.
For automated/mechanically operated parking the authority notwithstanding anything containing in the rules subject to such conditions as may be decided by the authority may permit parking lots/structures.
(B) Setbacks
The setbacks all round and spacing between blocks within the site for multi level parking structures upto 15.25m high shall be a minimum if 4.0m, irrespective of the area of location of the multi level parking structure. Where the height of the building exceeds 15.25m, the building shall conform to the norms laid in the special DR for MSB except in respect of the plot coverage and FSI requirements.
(C) Width of Entry and Exit
The width of entry or exit gates shall be a minimum of 4.5m. The entry or exit gate shall be located away from junctions. In cases of large sites with frontage along road exceeds 50 m; additional entry exit may be permitted.
(D) Other Requirements:
(i) Parapet/Protection Frame - All floors above ground floor shall have a RCC parapet/protection frame of height not less than 1.0m
(ii) Ventilation - In case of parking on ground floor, all sides shall be left open for ventilation and lighting. In case of all floors above ground floor, adequate natural ventilation and lighting should be provided. In case of basement or sub basement parking, adequate mechanical ventilation and adequate lighting should be provided.
(iii) Where car/two wheeler lifts are proposed/provided there shall be atleast one ramp to standards from the parking floors to the ground level.