(1) Doorways:
(i) Every doorway shall open into an enclosed stairway, a horizontal exit, on a corridor or passageway providing continuous and protected means of egress.
(ii) No exit doorway shall be less than 1 meter in width. Doorways shall be not less than 2 meter in height. Doorways for bathrooms, water closet and stores shall be not less than 0.75 meter wide.
(iii) Exit doorways shall open outwards, that is, away from the room but shall not obstruct the travel along any exit. No door, when opened, shall reduce the require width of stairway or landing to less than 0.9 meter, overhead or sliding doors shall not be installed.
(iv) Exit door shall not open immediately upon a flight or stairs, a landing equal to at least the width of the door shall be provided in the stairway at each doorway, level of landing shall be the same as that of the floor which it serves.
(v) Exit doorways shall be openable from the side which they serve without the use of a key.
(vi) Mirrors shall not be placed in exit ways or exit doors to avoid confusion regarding the direction of exit.
(vii) Revolving doors shall not be provided as a means of fire exit