| Table No.1: Sanitation requirement for shops and commercial offices | ||
| Sl. No. | Sanitary Unit / Fittings | For Personnel |
| (a) | (b) | (c) |
| 1. | Water closet | One for every 25 persons or part thereofexceeding 15 (including employees and customers). For female personnel 1 for every 15 persons or part thereof exceeding 10. |
| 2. | Drinking Water Fountain | One for every 100 person with a minimum of one on each floor. |
| 3. | Wash Basin | One for every 25 persons or part thereof. |
| 4. | Urinals | Same as Sl. No. 3 of Table for " Sanitation Requirements for Governmental and Public Business Occupancy and Offices" |
| 5. | Cleaners' Sink | One per floor minimum, preferably in or adjacent to sanitary rooms. |
| Note: Number of customers for the purpose of the above calculation shall be the average number of persons in the premises for a time interval of one hour during the peak period. For male-female calculation a ratio of 1: 1 may be assumed. | ||
| Table No. 2: Sanitation requirement for Hotels | Table No. 2: Sanitation requirement for Hotels | Table No. 2: Sanitation requirement for Hotels | Table No. 2: Sanitation requirement for Hotels | Table No. 2: Sanitation requirement for Hotels |
| Sl. No. | Sanitary Unit | For Residential Public staff | For non-residential Staff | For non-residential Staff |
| Sl. No. | Sanitary Unit | For Residential Public staff | For male | For female |
| (a) | (b) | (c) | (d) | (e) |
| 1. | Water Closet (W.C.) | One per 8 Persons omitting occupants of the attached water closet minimum of2 if both sexes are lodged | 1 for 1-15 persons 2 for 16-35 persons 3 for 36-65 persons 4 for 66-100 persons | 2 for 1-12 persons 4 for 13-25 persons 6 for 26-40 persons 8 for 41-57 persons 10for 58-77 persons 12for78-100 persons Add 1 for every 6 persons or part thereof. |
| 2. | Ablution Taps | One in each W.C. | One in each W.C. | One in each W.C. |
| 3. | Urinals | Nil | Nil upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 40-70 persons 4 for 71-100 persons | Nil |
| 4. | Wash Basins | One per 10 persons omitting each basin | 1 for 15 persons 2 for 16-35 persons 3 for 36-65 persons | 1 for 1-12 2 for 13-25 3 for 26-40 |
| Table No. 2: Sanitation requirement for Hotels | Table No. 2: Sanitation requirement for Hotels | Table No. 2: Sanitation requirement for Hotels | Table No. 2: Sanitation requirement for Hotels | Table No. 2: Sanitation requirement for Hotels |
| Sl. No. | Sanitary Unit | For Residential Public staff | For non-residential Staff | For non-residential Staff |
| Sl. No. | Sanitary Unit | For Residential Public staff | For male | For female |
| (a) | (b) | (c) | (d) | (e) |
| installed in the room / suite | 4 for 66-100 persons | 4 for 41-57 | ||
| 5. | Baths | One per 10 persons, less occupants of room with bath in suite | Nil | Nil |
| 6. | Cleaner's Sinks | One per 30 Bed rooms (one per floor minimum) | Nil | Nil |
| 7. | Kitchen Sink | One in each Kitchen | One in each Kitchen | One in each Kitchen |
| Table No. 3: Sanitary requirements for Public Rest Room | |||
| Sl. No | Sanitary Unit | For Male | For Female |
| (a) | (b) | (c) | (d) |
| 1. | Water Closet | One per 100 persons upto 400 persons; for over 400 add at the rate of one per 250 persons or part thereof. | Two for 100 persons upto 200 persons; over 200 add at the rate of one per 100 persons or part thereof. |
| 2. | Ablution Taps | One in each W.C. | One in each W.C. |
| 3. | Urinals | One for 50 persons or part thereof. | Nil, upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons 4 for 71-100 persons |
| 4. | Washbasins | One per WC/Urinal | One per WC |
| 5. | Kitchen Sink | One in each Kitchen | One in each Kitchen |
| 6. | Baths (showers) | One per 10 persons | |
| 7. | Cleaner's Sinks | One per 30 Bed rooms (one per floor minimum) | |
| Note: i) It may be assumed that the two-thirds of the number are males and one- third females. ii) One water tap with drainage arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closet and urinals. | |||
| Table No.4: Sanitation requirement for Education Occupancy | |||||
| Sl. No | Sanitary Unit | Boarding Institution | Other Educational Institution | ||
| For Boys | For Girls | For Boys | For Girls | ||
| (a) | (b) | (c) | (d) | (e) | (f) |
| 1. | Water Closet (W.C.) | One for 8 boys or part thereof | One for 6 girls or part thereof | One for 40 boys or part thereof | One for 25 girls or part thereof |
| 2. | Ablution Taps | One in each W.C. | One in each W.C. | One in each W.C. | One in each W.C. |
| 3. | Urinals | One per every 25 pupils or part thereof | -- | One per every 20 pupils or part thereof | -- |
| 4. | Wash Basins | One for every 8 pupils or part thereof | One for every 6 pupils or part thereof | One for every 60 pupils or part thereof | One for every 40 pupils or part thereof |
| 5. | Baths | One for every 8 pupils or part thereof | One for every 6 pupils or part thereof | -- | -- |
| 6. | Drinking Water Fountains | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof |
| 7. | Cleaner's Sink | One per Floor minimum | One per Floor minimum | One per Floor minimum | One per Floor minimum |
| Table No. 5: Sanitation requirements for Educational Occupancy (Nursery School) | ||
| Sl. No. | Sanitary Unit | Requirement |
| (a) | (b) | (c) |
| 1. | Water Closet | One for 15 boys, one for 6 girls |
| 2. | Ablution Taps | One in each W.C. |
| 3. | Urinals | One for 12 boys |
| 4. | Wash Basins | One for every 15 pupils or part thereof |
| 5. | Baths | One bath per 40 pupils |
| 6. | Drinking Water Fountains | One for every 50 pupils or part thereof |
| 7. | Cleaner's Sink | One per Floor minimum |
| Note: i) One water tap with draining arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closets and urinal. ii) For teaching staff, the schedule of sanitary units to be provided shall be the same as in case of office buildings | ||
| Table No. 6: Sanitation requirements for Institutional (Medical) Occupancy- Hospital | ||||
| Sl. No. | Sanitary Unit | Hospitals With indoor Patient Ward For Males and females | Hospitals With outdoor Patient Wards | |
| For Males | For Females | |||
| (a) | (b) | (c) | (d) | (e) |
| 1. | Toilet Suite (1WC+ 1Washbasin+ 1 shower) | Private room upto 4 persons | For upto 4 patients | |
| 2. | Water Closet (W.C.) | One for every 8 beds or part thereof | One for every 100 personsor part thereof | One for every 25 persons or part thereof |
| 3. | Ablution taps | One in each W.C. | One in each W.C. | One in each W.C. |
| 4. | Wash Basins | Two upto 30 bed; add one for every additional 30 beds; or part thereof | One for every 100 persons or part thereof | One for every 25 persons or part thereof. |
| 5. | Baths with Shower | One bath with shower for every 8 beds or part thereof. | -- | -- |
| 6. | Bed pan washing sink | One for each ward | -- | -- |
| 7. | Cleaner' Sinks | One for each ward | One per floor minimum | One per floor minimum |
| 8. | Kitchen sinks and dish Washers (where Kitchen is provided) | One for each ward | -- | -- |
| 9. | Urinals | One for 30 beds (male wards) | One for every 50 persons or part thereof | -- |
| 10. | Drinking water Fountain | One for each ward | One for 500 persons or part thereof | |
| Note: For teaching staff, the schedule of sanitary units to be provided shall be the same as in case of office buildings | ||||
| Table No. 7: Sanitation requirements for Institutional - Hospital (Administrative Buildings) | Table No. 7: Sanitation requirements for Institutional - Hospital (Administrative Buildings) | Table No. 7: Sanitation requirements for Institutional - Hospital (Administrative Buildings) | Table No. 7: Sanitation requirements for Institutional - Hospital (Administrative Buildings) |
| Sl. No. | Sanitary Unit | For Males | For Females |
| (a) | (b) | (c) | (d) |
| 1 | Toilet Suite (1WC+ 1Washbasin+1shower) | For individual doctor's/officer's rooms | Toilet Suite (1WC+ 1Washbasin+1shower) |
| 2 | Water Closet (W.C.) | One for every 25 persons or part thereof | Water Closet (W.C.) |
| 3 | Ablution Taps | One in each W.C. | Ablution Taps |
| 4 | Wash Basins | One for every 25 persons or part thereof | Wash Basins |
| 5 | Baths with Shower | One on each floor | Baths with Shower |
| 6 | Cleaner's Sink | One per floor minimum | Cleaner's Sink |
| 7 | Kitchen sinks and dish Washers (where Kitchen is provided) | One for each floor | Kitchen sinks and dish Washers (where Kitchen is provided) |
| 8 | Nil upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons 4 for 71-100 persons From 101 to 200 persons add at the rate of 3%; for over 200 persons add at the rate of 2.5%. | ||
| 9 | Drinking water fountain | One for 100 persons or part thereof | One for 100 persons or part thereof |
| Table No. 8: Sanitation requirements for Institutional (Medical) Occupancy- (staff quarters and Hostels) | ||||
| Sl. No. | Sanitary Unit | Doctor's Dormitories | Nurses Hostel | |
| For Male Staff | For female staff | |||
| (a) | (b) | (c) | (d) | (e) |
| 1 | Water Closet | One for 4 persons | One for 2 persons | One for 2 persons or part thereof Two for 13-25 |
| 2 | Ablution Taps | One in each W.C. | One in each W.C. | One in each W.C. |
| 3 | Wash Basins | One for every 8 persons or part thereof | One for every 8 persons or part thereof | One for every 8 persons or part thereof |
| 4 | Bath (with shower) | One for every 4 persons or part thereof | One for every 4 persons or part thereof | One for every 4 persons or part thereof |
| 5 | Cleaner's Sink | One per floor minimum | One per floor minimum | One per floor minimum |
| 6 | Drinking water fountain | One for 100 persons or part thereof | One for 100 persons or part thereof | |
| Table No. 9: Sanitation requirements for Governmental and Public Business Occupancy and Offices | Table No. 9: Sanitation requirements for Governmental and Public Business Occupancy and Offices | Table No. 9: Sanitation requirements for Governmental and Public Business Occupancy and Offices | Table No. 9: Sanitation requirements for Governmental and Public Business Occupancy and Offices |
| Sl. No. | Sanitary Unit | For Male Personnel | For female Personnel |
| (a) | (b) | (c) | (d) |
| 1. | Water Closet (W.C.) | One for 25 persons or part thereof | Two for 15 persons or part thereof |
| 2. | Ablution taps | One in each W.C. | One in each W.C. |
| 3 | Urinals | Nil upto 6 persons | |
| 3 | Urinals | 1 for 7-20 persons | |
| 3 | Urinals | 2 for 21-45 persons | |
| 3 | Urinals | 3 for 46-70 persons | |
| 3 | Urinals | 4 for 71-100 persons | |
| 3 | Urinals | From 101 to 200 add @ 3%; | |
| 3 | Urinals | For over 200 persons add @ 2.5%. | |
| 4 | Wash Basins | One for every 25 persons or part thereof | One for every 25 persons or part thereof |
| 5 | Drinking water fountains | One for every 100 persons with a minimum of one on each floor | One for every 100 persons with a minimum of 1 on each floor |
| 6 | Cleaner's Sinks | One per floor minimum; preferably in or adjacent to sanitary rooms. | -- |
| 7 | Executive Room /Conference Halls | Toilet Suite (1 WC, 1 washbasin, optional shower for 24 hr usages) Unit could be common for Male/Female or separate depending on the number of user of each facility | Toilet Suite (1 WC, 1 washbasin, optional shower for 24 hr usages) Unit could be common for Male/Female or separate depending on the number of user of each facility |
| Note: One water tap with drainage arrangements shall be provided / 50 persons or part thereof in the vicinity. | Note: One water tap with drainage arrangements shall be provided / 50 persons or part thereof in the vicinity. | Note: One water tap with drainage arrangements shall be provided / 50 persons or part thereof in the vicinity. | Note: One water tap with drainage arrangements shall be provided / 50 persons or part thereof in the vicinity. |
| Table No.10: Sanitation Requirements for Assembly Occupancy Buildings (Cinema, Theaters, Auditoria. Etc.) | Table No.10: Sanitation Requirements for Assembly Occupancy Buildings (Cinema, Theaters, Auditoria. Etc.) | Table No.10: Sanitation Requirements for Assembly Occupancy Buildings (Cinema, Theaters, Auditoria. Etc.) | Table No.10: Sanitation Requirements for Assembly Occupancy Buildings (Cinema, Theaters, Auditoria. Etc.) | Table No.10: Sanitation Requirements for Assembly Occupancy Buildings (Cinema, Theaters, Auditoria. Etc.) | Table No.10: Sanitation Requirements for Assembly Occupancy Buildings (Cinema, Theaters, Auditoria. Etc.) |
| Sl. No. | Sanitary Unit | For Public | For Public | For Staff | For Staff |
| Sl. No. | Sanitary Unit | Male | Female | Male | Female |
| (a) | (b) | (c) | (d) | (e) | (f) |
| 1 | Water Closet | One for 100 persons upto 400 persons. | Four for 100 persons upto 200 persons. | One for 15 persons. | Two for 1-12 persons. |
| 1 | Water Closet | For over 400 persons, add at the rate of 1 per 250 persons or part thereof | For over 200 persons, add at the rate of 1 per 50 persons or part thereof | Two for16-35persons. | Four for 13-25 persons add at the rate of 1 per 6 persons or part thereof |
| 2 | Ablution Taps | One in each W.C. | One in each W.C. | One in each W.C | One in each W.C |
| 3 | Urinals | One for 50 persons or part thereof | --- | Nil upto 6 persons | --- |
| 3 | Urinals | One for 50 persons or part thereof | --- | One for 7-20 persons | --- |
| 3 | Urinals | One for 50 persons or part thereof | --- | Two for21-45persons | --- |
| 4 | Wash Basins | One for every 200 persons or part thereof | One for every 200 persons or part thereof | One for1-15persons | One for 1-12 persons |
| 4 | Wash Basins | One for every 200 persons or part thereof | One for every 200 persons or part thereof | Two for16-35persons | Two for 13-25 persons |
| 5 | Drinking Water fountain | One per 100 persons or part thereof |
| Table No.12: Sanitation Requirements for Restaurants | Table No.12: Sanitation Requirements for Restaurants | Table No.12: Sanitation Requirements for Restaurants | Table No.12: Sanitation Requirements for Restaurants | Table No.12: Sanitation Requirements for Restaurants | Table No.12: Sanitation Requirements for Restaurants |
| Sl.No. | Sanitary Unit | For Public | For Public | For Staff | For Staff |
| Sl.No. | Sanitary Unit | Male | Female | Male | Female |
| (a) | (b) | (c) | (d) | (e) | (f) |
| 1 | Water Closet | One per 50 seats upto 200 seats. | One per 25 seats upto 200 seats. | 1 for 15 persons. | 2 for 1-12 persons. |
| 1 | Water Closet | For over 200 seats, add at the rate of 1 per 100 seats or part thereof | For over 200 seats, add at the rate of 1 per 50 seats or part thereof | 2 for 16-35 persons. | 4 for 13-25 persons |
| 1 | Water Closet | For over 200 seats, add at the rate of 1 per 100 seats or part thereof | For over 200 seats, add at the rate of 1 per 50 seats or part thereof | 3 for 36-65 persons | 6 for 26-40 persons |
| 1 | Water Closet | For over 200 seats, add at the rate of 1 per 100 seats or part thereof | For over 200 seats, add at the rate of 1 per 50 seats or part thereof | 4 for 66-100 persons | 8 for 41-57 persons |
| 1 | Water Closet | For over 200 seats, add at the rate of 1 per 100 seats or part thereof | For over 200 seats, add at the rate of 1 per 50 seats or part thereof | 10 for 58-77 persons | |
| 1 | Water Closet | For over 200 seats, add at the rate of 1 per 100 seats or part thereof | For over 200 seats, add at the rate of 1 per 50 seats or part thereof | 12 for 78-100 persons | |
| 2 | Ablution Taps | One in each W.C. | One in each W.C. | One in each W.C | One in each W.C |
| 3 | Urinals | One for 50 persons or part thereof | --- | Nil upto 6 persons | --- |
| 3 | Urinals | One for 50 persons or part thereof | --- | 1 for 7-20 persons | --- |
| 3 |
| Table No.13: Requirements for Factories | |||
| Sl. No. | Sanitary Unit | For Male Personnel | For female Personnel |
| (a) | (b) | (c) | (d) |
| 1 | Water Closet | 1 for 15 persons | 2 for 1-12 persons |
| 2 for 16-35 persons | 4 for 13-25 persons. | ||
| 3 for 36-65 persons. | 6 for 26-40 persons. | ||
| 4 for 66-100 persons. | 8 for 41-57 persons. | ||
| 10 for 58-77 persons. | |||
| 12 for 78-100 persons. | |||
| For 101 to 200 persons add at rate of 3%. From over 200 persons, add at the rate of 2.5%. | For 101 to 200 persons, add at the rate of 3%. From over 200 persons add at the rate of 2%. | ||
| 2 | Ablution Taps | One in each W.C | One in each W.C. |
| 3 | Urinals | Nil upto 6 persons | |
| 1 for 7-20 persons | |||
| 2 for 21-45 persons | |||
| 3 for 46-70 persons | |||
| 4 for 71-100 persons | |||
| From 101 to 200 persons add at the rate of 3%; for over 200 persons add at the rate of 2.5%. | |||
| 4 | Washing Taps with draining arrangement | One for every 25 persons or part thereof | |
| 5 | Drinking Water Fountains | One for every 100 persons with a minimum of one on each floor | |
| 6 | Baths Preferably Showers | As required for particular trade or occupation |
| 7 | Emergency shower and eye wash fountain | 1 per every shop floor per 500 person |
| Note: i) For many trades of a dirty or dangerous character, more extensive provisions are required. ii) One water tap with draining arrangement shall be provided for every 50 persons or part thereof in the vicinity of water closet and urinal. iii) Creche where provided shall be fitted with water closets (One for 10 persons or part thereof), wash basins (1 for 15 persons or part thereof) and drinking water tap with drinking arrangement for every 50 persons or part thereof. | ||
| Table No.14: Sanitary Requirements for Large Stations and Airports | ||||
| Sl. No. | Place | W.C. for Males | W.C. for Females | Urinals for Males only |
| (a) | (b) | (c) | (d) | (e) |
| 1 | Junction Stations, Intermediate Stations and Substations | 3 for first 1000 persons, add 1 for subsequent 1000 persons or part thereof. | 8 for first 1000 persons, add 1 for every additional 1000 persons or part thereof. | 4 for every 1000 person, add 1 for every additional 1000 persons or part thereof. |
| 2 | Terminal Stations and Bus Terminals | 4 for first 1000 persons and 1 for every additional 1000 persons or part thereof. | 10 for every 1000 person and 1 for every additional 1000 persons or part thereof. | 6 for every 1000 person and 1 for every additional 1000 persons or part thereof. |
| 3 | Domestic Airports | 1 per 40 persons or part thereof. | ||
| Minimum | 2* | 4* | ||
| 200 persons | 5 | 16 | ||
| 400 persons | 9 | 30 | ||
| 600 persons | 12 | 40 | ||
| 800 persons | 16 | 52 | ||
| 1000 persons | 18 | 58 | ||
| 4 | International Airports | 1 per 40 persons or part thereof. | ||
| 200 persons | 6 | 20 | ||
| 600 persons | 12 | 40 | ||
| 1000 persons | 18 | 58 | ||
| Note:- (i) Provision for wash basins, baths including shower stalls, shall be in accordance with Drainage and Sanitation section of National Building Code of India. (ii) At least one Indian style water closet shall be provided in each toilet. Assume 60 % males and 40 % females in any area. (iii) At least 50 % of female WCs may be Indian pan and 50% EWC. | ||||