Apartment.— (1) In Apartment building with joint ownership of land, the owner or developer shall provide floor space for house owner’s society office and assembly at the rate of one square meter per flat, provided that the minimum area shall not be less than 12 square meters.
One staircase for every 6 dwelling units or fraction thereof in a floor shall be provided.
The minimum width of approach road to the plot shall be 9 meters for Apartment buildings.
Reservation of affordable housing i.e., EWS and LIG housing shall be done as per provisions of affordable housing overlay.
Outhouse.— An outhouse with zero rear and one side set back may be permitted on a plot having an area not less than 150 square meters:
Provided that—
(i) the coverage of the outhouse shall not exceed 30 square meters and the height shall not exceed 3 meters;
(ii) the built up area of the outhouse and that of the main building together shall not exceed the permissible FAR for the concerned plot;
(iii) the outhouse shall not cover more than one third of the width and more than one fourth of depth of the plot and shall not abut any public road;
(iv) a minimum 1.5 meters strip of land shall be kept open to the sky between the main building and the outhouse;
(v) no opening either in the form of windows or doors or ventilators shall be provided to the adjoining properties; and
(vi) outhouses with sloping roof would only be permitted and in no case permission for outhouses would be granted with reinforced concrete cement flat roof.
Requirements for old settlement area.— (1) In an old settlement area, permission to erect a building may be given on the basis of the available width of means of access, provided that where the width of means of access is 4.5 metres or less, the coverage shall be limited to 50% of the plot area and the maximum height of the building shall be limited to two storey and the F.A.R. shall be limited to 1.00.
For plots with narrow width, i.e. a width of 7.5 meters or less, zero setbacks may be allowed on one side with a passage of one meter on the other side.
The rear setback and front setback shall not be less than 3.0 meters and 1.5 meters, respectively.
In each house on a old settlement plot having one side setback, an internal courtyard of not less than 10 square meters in area and not less than 2.5 meters in width shall be provided in such a way that at least one wall of each living room abuts such court-yard or a verandah opening to such court-yard.
Construction proposed in all existing buildings which have been divided into parts by partition or sale or otherwise may be permitted (without insisting on front, rear or side setbacks) subject to fulfilment of following provisions, namely:—
(i) coverage provided for the upper floor shall not exceed 75% of the plinth area of existing floor for organizing an open terrace to facilitate light and ventilation to the habitable rooms;
(ii) separate arrangement shall be made for drainage of the storm water;
(iii) ventilators may be permitted above lintel height on production of no objection certificate from the owners of the adjacent plot to which the ventilators abuts, but no window overlooking others property may be permitted without obtaining his written consent in the shape of an affidavit.
For construction on the first and subsequent floors on existing floors in old settlement area, on zero setbacks on one sides may be permitted, provided that the construction does not lead to closing down of windows or ventilators or skylights of the neighbouring plot which are already existing lawfully.
While according permissions without providing required setbacks, no-objection certificate in the shape of an affidavit from the side neighbour may be obtained and reasons for the same may be recorded in writing.
Semi- detached and row housing.— (1) Owners of adjacent similar dimension plot abutting a road may be permitted to construct row or semi-detached buildings.
The orientation of the row or semi-detached building shall preferably be such that the prevailing summer breeze can be availed by each dwelling unit.
For semi-detached buildings over two adjacent plots, the setbacks, the height and the FAR shall be regulated by treating both the plots as one.
In case of row housing, the length of a row shall not exceed 50 meters along the road on which such houses abut.
In case, the dwelling units in a row are scattered, the maximum length of the road shall be 100 meters.
For row houses the ground coverage shall not be allowed to exceed 60% and the FAR more than 1.75.
The minimum size of the plot on which a unit of a row housing may be allowed shall be 30 square meters.
Shop cum residence.— Where plots are allotted in a row for shop-cum-residential purpose, the Authority may allow construction of shop-cum-residential building without any side set backs up to a depth of 10 meters from the front exterior wall:
Provided that no part of the building up to said depth is used for residential purpose on the ground floor and no building exceeding 12 meters in height shall be allowed to be constructed on a shop-cum-residential plot, unless so permitted under the Development Plan:
Provided further that the shop-cum-residence shall have only 2/3rd of the total floor area used for shops:
Provided also that the FAR and other parameters shall conform to that specified for commercial buildings.
Assembly Buildings (Cinemas, Theatres, Multiplex, Auditorium, Museum, Exhibition hall, Gymnasium, Stadia, Restaurant, Club room, etc.).— (1) The relevant provisions of the Odisha Cinemas (Regulations) Rules, 1954 shall apply for planning, designing and construction of Cinema and Theatre buildings.
The minimum width of the means of access for Cinema hall, Multiplex, convention centers and stadium shall be 18 meters.
No permission for construction of a assembly building to be used as a cinema hall, theatre or auditoria for cultural show, shall be granted unless the construction of such buildings conforms to the provisions of the Odisha Cinemas (Regulations) Act, 1954 and the Odisha Cinematograph Rules, 1939, the National Building Code of India or any other law on the subject for the time being in force in the State.
No permission to construct a cinema hall on a site shall be given unless such site has been approved by the Authority for the purpose.
Excepting provision for restaurant and incidental facilities no other use shall be permitted in a cinema building.
All cinema, multiplexes, theatres or auditoria buildings shall conform to IS; 4878-1986 and acoustics design of such buildings shall adhere to the requirements of IS; 2526-1963.
Exits and fire safety requirements shall be in accordance with Part IV (Fire and life safety) of the National Building Code of India.
Parking norms shall apply as per provisions of rule 37 of these rules.
Requirements of water supply, drainage and sanitation shall be as per provisions of the National Building Code of India.
Notwithstanding anything contained in rule 63, the setback provision for multiplex shall be as prescribed in Table No.14 below.
| Table No. 14: Setback provision for multiplex | |||
| Sl. No | Category of Multiplex | Minimum Front Setback | Minimum setback on all other sides |
| (a) | (b) | (c) | (d) |
| 1 | Independent multiplex building (Total built up area of 90% or more under cinema hall with commercial use limited to 10% of total built-up area shall be considered as Independent multiplex building.) | 12 | 6 |
| 2 | Multiplex within commercial building where the area under multiplex is more than 1/3rd of total built-up area or total number of seats exceeding 400 | 9 | 6 |
| 3 | Multiplex within commercial building where the area under multiplex is not more than 1/3rd of total built-up area or total number of seats is not more than 400. | 7.5 | 6 |
| Note:- (i) In case of multiplex within commercial building, special buildings or high-rise buildings, the higher setback prescribed for any of the aforesaid activities under these rules shall be applicable (ii) In case of multiplex buildings the exterior open space around a building for a width of | |||
7.5 meters shall be kept unbuilt except where the open space requirement is less than 7.5 meters, the entire specified open space shall be kept unbuilt. It shall be constructed of hard surface capable of taking load of fire engine weighing up to 45 tonnes.
Commercial activity in mixed use building.— (1) Subject to provisions of the zoning regulations, in mixed-use buildings, commercial activity shall be permitted as per the following criteria, namely:—
(i) for road width of 12m, commercial use shall only be allowed in ground floor:
Provided, if additional front- setback of 2m. is provided above the minimum setback and without front boundary wall, then the total front setback may be considered towards parking area calculation as surface parking;
(ii) for road width of 18m and above but less than 24m, only ground and first floor shall only be allowed for commercial use.
(iii) for road width of 24m and above but less than 30m, commercial use shall only be allowed in the ground, first and second floors.
(iv) for road width of 30m and above, commercial use may be provided in all floors.
Commercial activities shall be permitted on 9 meter wide road in the ground floor up to a depth of 10 meters from the front setback line:
Provided, if additional front- setback of 1m. is provided above the minimum setback and without front boundary wall, then the total front setback may be considered towards parking area calculation as surface parking;
Subject to provisions prescribed under sub-rule (1) and (2) above and zoning restrictions of the Authority, apartments and housing projects with commercial activities limited to 5% of the built-up area shall not be considered as mixed-use buildings.
Hotel Premises.— (1) A hotel premises may also have other permitted activities along with hotel activity, namely, service apartment, banquet, conferencing facilities, restaurant, swimming pool, health club, food court and discotheque.
Commercial offices, retail and service shops to be restricted to 20% of Floor area in Hotel Premises.
In case of land allotted by Government for Hotel purpose the commercial activity shall be permitted upto 20% of floor area, if specific provision for extent of commercial activities is not mentioned in the condition of lease or auction:
Provided that, if the extent of commercial usages have been specified in the terms and conditions of the lease deed/auction and if the same exceeds 20% of floor area, the same shall be allowed, subject to overall limit prescribed by the Authority in the regulations.
The commercial activity to be permitted within a hotel premises, shall be in compliance to the use restriction specified in zoning regulations and other provisions of these rules applicable to the specific commercial activity proposed within the hotel premises.
Liquefied petroleum gas or Gas Cylinder Godown.— (1) Vacant space shall be maintained at all times as given in Table No.15 below:
| Table cylind | No. 15: Minimum distances required for stor ers | age shed of liquefied petroleum gas |
|---|---|---|
| Sl. | Quantity of Compressed Gas in Cylinders | Minimum Clear Distance to be kept |
| No | (Kg.) | (in meters) |
| (a) | (b) | (c) |
| 1 | 0-100 | 1 |
| 2 | 101 -1000 | 3 |
| 3 | 1001- 4000 | 5 |
| 4 | 4001-8000 | 7 |
| 5 | 8001-12000 | 9 |
| 6 | 12001-30,000 | 12 |
| 7 | Over 30,000 | 15 |
Notwithstanding anything contained in the conditions specified in the Table, cylinders containing liquefied petroleum gas exceeding 100 kilograms but not exceeding 300 kilograms, may be kept in a storage shed forming part of, or attached to building, if it is separated there from by a substantial partition and the only means of access to it is from outside and such a storage shed shall not be situated under any staircase or near other entrances to or exits from the rest of the building or other buildings.
A shed used for storage of liquefied petroleum gas cylinders shall be surrounded by a suitable fence to prevent unauthorized persons from having access to the shed.
Norms for Petrol Pump.— (1) Minimum distance from the road intersections shall be—
(i) for minor roads having less than 30 meters width -- 50 meters.; and
(ii) for major roads having width 30 meters or more -- 100 meters.
The minimum distance of the property line of petrol pump from the Centre line of the road shall not be less than 15 meters on roads having less than 30 meter width. In case of roads having 30 meter or more width, the width of the road shall be protected.
Plot size shall be—
(i) for filling stations only -- 30 meters × 17 meters;
(ii) for filling-cum-service station -- 36 meters × 30 meters;
The frontage of the plots mentioned in clause (i) and (ii) of sub-rule (3) shall not be less than 30 meters.
Other conditions shall include—
(i) new petrol pump shall not be located on roads having less than 30 meters width;
(ii) every petrol pump shall adhere to the norms as prescribed in IRC Code: 12-
2009, as amended from time to time; and
(iii) every petrol pump shall have public toilets with Water Closet (WC) separately for men and women.
Other controls for installation of petrol pump shall include—
(i) Ground coverage -- 20% ;
Note: Ground coverage will exclude canopy area
(ii) FAR -- 0.20 ;
(iii) Max. height -- 7 meters ;
(iv) Canopy equivalent to permissible ground coverage within setback line;
(v) Front set back -- minimum 6 meters
Other requirements for installation of petrol pump shall be—
(i) NOC from Explosives and Fire Department
(ii) License from the District Magistrate
In case of Compressed Natural Gas (CNG) mother station—
(i) Plot size (Max) -- 36 meters × 30 meters
(ii) Maximum ground coverage --20%
(iii) Maximum height -- 7 meters (single storey)
(iv) Building component -- control room, office, dispensary, store, pantry and W.C.
Farm House.— (1) For construction of Farm House Building in Agricultural Use Zone, minimum size of plot shall not be less than 1.00 hectare.
Maximum coverage and FAR shall be as given in Table No.16 below:
| Table No. 16: Maximum Coverage and FAR | ||
| Sl.No. | (a) | (b) |
| 1 | Maximum permissible ground coverage for all types ofactivity | 15 percent |
| 2 | Maximum built-up area (BUA) allowed | 500 square meters for every 1 Ha. |
| 3 | Residential accommodation of watch and ward/maintenance staff | 100 square meters |
| 4 | Maximum height | 7 meters |
| 5 | Setbacks | Front/side abutting road 15.0 meters and all other sides 9.0 meters |
Minimum 65% percent of the total area of the farmhouse shall be under plantation
or cultivation and at least 100 trees per hectare shall be planted out of which at least 50 percent shall be evergreen trees.
In case of a plot for a farmhouse having dwelling units, the owner thereof shall be responsible to make lawful arrangements for potable water.
The owner shall be responsible to provide drains in the farm house to be used for rain water and in case of dairy farm open or closed sanitary drains to clean sheds, as may be required by the Authority.
The owner shall be responsible to provide septic tank with necessary disposal trenches for disposal of human and animal waste in the farmhouse within his own premises.
The owner of a farmhouse shall obtain electric connection directly from the appropriate authority authorized for distribution on such terms and conditions at his own cost as decided by the appropriate Authority.
For the purpose of sub-division of land for farmhouse, provisions of rules for approval of layout provided in Chapter-VII shall apply.
Norms for solid waste management shall apply.
The permitted activity of farm house shall not be modified into other activities.
Country Homes.— (1) For construction of Country Homes in Agricultural Use Zone, minimum size of plot shall not be less than 2000 square meters which shall be low density residential areas in peri-urban and rural areas and the minimum size of the project in such areas for approval shall be at least 10 acres.
Maximum coverage and FAR shall be as given in Table No.17 herein contained—
| Table No. 17: Maximum coverage and FAR | ||
| Sl. No. | (a) | (b) |
| 1 | Maximum permissible ground coverage for all types ofactivity | 15 percent |
| 2 | Maximum built-up area (BUA) allowed | 250 square meters for every 2000 square meters of plot area. |
| 3 | Residential accommodation of watch and ward/maintenance staff | 20 square meters |
| 4 | Maximum height | 7 meters |
| 5 | Setbacks | Front/side abutting road 15.0 meters and all other sides 9.0 meters |
Minimum 65% percent of the total area of the country-home shall be under plantation or cultivation and at least 100 trees per acre shall be planted out of which at least 50 percent shall be evergreen trees.
In case of a plot for a country-home having dwelling units, the owner thereof shall be responsible to make lawful arrangements for potable water.
The owner shall be responsible to provide drains in the country-home to be used for rain water and in case of dairy farm, open or closed sanitary drains to clean sheds, as may be required by the Authority.
The owner shall be responsible to provide septic tank with necessary disposal trenches for disposal of human and animal waste in the country home within his own premises.
The owner of a country home shall obtain electric connection directly from the appropriate authority authorized for distribution on such terms and conditions at his own cost as decided by the appropriate Authority.
For the purpose of sub-division of land for country homes, provisions of rules for approval of layout provided in Chapter-VII shall apply.
Norms for solid waste management shall apply.
The permitted activity of country homes shall not be modified into other activities.