Exterior open spaces for buildings having height up to 12.5 meters.
(1) Front open spaces.
(a) Every Residential Building having height up to 12.5 meters, facing street shall have a front open space mentioned below and such open space shall form an integral part of the site:-
| S. No. | Width of street facing the plot | Front open space Min. |
|---|---|---|
| (1) | (2) | (3) |
| 1. | up to 9.0 meters | 3.0 meters |
| 2. | More than 9.0 meters and up to 12 meters | 3.6 meters |
| 3. | More than 12.0 meters and up to 18 meters | 4.5 meters |
| 4. | Above18 meters. | 6.0 meters |
392 (228)
(b) In existing developed areas with streets less than 6.0 meters in width the distances of the building (building line) shall be at 6.0 meters from the center line of the street.
(2) Rear Open Space.
(a) Every Residential Building, having height up to 12.5 meters, shall have a Rear Open Space, as below :-
| Sr. No. | Plot area in Square meters | Building height in meters | Minimum Rear Open space in meters |
|---|---|---|---|
| (1) | (2) | (3) | (4) |
| 1. | Up to 40.00 | 10.00 | Nil |
| 2. | Above 40.00 and Up to 150.00 | 10.00 | 1.50 |
| 3. | Above 150 and up to 225.00 | 10.00 and above | 2.50 |
| 4. | Above 225.00 | 10.00 and above | 3.00 |
(b) Rear open space to extend through the rear wall. The rear open space shall be co-extensive with the entire face of the rear wall. If a building abuts on two or more streets, such rear open space shall be provided through-out the entire face of the rear wall. Such rear wall shall be the wall on the opposite side of the face of the building abutting on the wider street unless the Authority otherwise directs:
(3) Side open space.
Every semi-detached and detached building shall have a permanently side open airspace, forming integral part of the site as below :-
(i) For detached buildings there shall be minimum side open spaces of 3 meters on both the sides :
Provided that for detached residential building up to 7 meters in height on plots with a frontage less than 12 meters, one of the sides open space may be reduced to 1.5 meters.
(ii) For semi-detached building there shall be a minimum side open space of 3.0 meters on one side. For Semi-detached building up to 10 meters in height on plots with a frontage up to 10 meters, the side open space may be
मध्यप्रदेश राजपत्र, दिनांक 13 अपैल 2012
392 (229)
reduced to 2.5 meters. In the case of semi-detached buildings, the open spaces provided on one side shall be as in this sub-rule and all habitable rooms shall abut either on this side open space or front and rear open spaces or an interior open space.
(iii) For row-type buildings, no side open space is required.
(4) Notwithstanding provision of sub-rule (2). and (3) garage may be permissible in rear end of the side open space.
(5) Open space for building of more than 12.5 meters height. For building of height above 12.5 meters the open spaces around building shall be as given in Table 4 and 5 of Rule 42.
(6) Interior open spaces for all buildings.
(a)·Inner Courtyard-
(i) Every room (except bath, water closet and store room) that does not abut on either the front, rear or side open spaces shall abut on an inner courtyard, whose minimum side shall be 3 meters.
(ii) Further the inner courtyard shall have an area, throughout its height, of not less than the square of one-fifth the height of the highest wall abutting the courtyard.
Provided that when any room (excluding staircase bay, bathroom and water closet) is dependent for its light and ventilation on an inner courtyard, the dimension shall be such as is required for each wing of the building.
(ii). Where only water closet and bath room are abutting on the interior courtyard, the size of the interior courtyard shall be in line with the provision for ventilation shaft as given in clause (b).
(b) Ventilation Shaft. For ventilating the spaces for water closet and bath room in all types and height of buildings, if not opening on the front or side or rear or interior open spaces, shall open on to the ventilation shaft, the size of which shall not be less than the values given below :-
| Height of buildings in meters | Size of ventilation shaft in square meters | Minimum size of a side of shaft in meters |
|---|---|---|
| (1) | (2) | (3) |