Schedule IProposed Fee Structure for determining the ‘Building Permit $F e e ^ { flat }$ for various types of structure
Sl. No
Type
Rate
1
Type I: Assam Type pitched roof with corrugated sheets and timber framed structure OR Pitched roof with corrugated sheets and R.C.C or R.B column and brick wall
Rs 500/-
2
Type II: RCC Type structure having Plinth Area less than 3000 sq.ft
Rs 2000/-
3
Type III: RCC Type structure having Plinth Area more than 3000 sq.ft
Rs 3000/-
4
Type IV: All commercial and utility structures incl;uding filling stations, cinema, telephone towers, etc.
Rs 5000/-
Forms
FORM – A (See Regulation 4 of the Nagaland Building Bye-Laws) (To be submitted in triplicate)
Application to Construct Building or Execute Any Work
To,
____
____
____
Sir,
I / We beg to apply for permission to construct / reconstruct / add / alter / repair of a building at plot No ____ Ward No ____ House No ____ according to building plans submitted herewith.
Description of Construction / reconstruction / add / alter / repair:
Ground Floor / First Floor
2nd Floor
3rd Floor
4th Floor
Specifications, general and detail
I / We attach (a) Site Plan in Triplicate showing the position of the plot proposed to be built up (b) a certificate of Ownership from Revenue Authority (c) Three copies of plans, all elevations, sections and other details as specified in Regulation No. 4.
The plans have been prepared by: Licensed / Registered Architects / Engineers
Yours faithfully,
Signature of Owner(s)
Name of Owner(s)....
Address....
Dated....
FORM – B (see Regulation 14 of the Nagaland Building Bye-Laws)
Service Connection Certificate
To,
____
____
____
____
With reference to your notice dated ____ I hereby:
Grant permission for the occupation of the said building or
Grant clearance for the water supply and electric connection in the said building.
Refuse permission for the occupation of the said building for the reason given below:
____
____
____
____
Description of the building:
Building No. ____ Plot No. ____
Ward No._ Street Road No._
FORM NO 1 (see Regulation 4(iii) of the Nagaland Building Bye-Laws) (Appendix A Para 2.3.1 and 2.3.2) CERTIFICATE OF UNDERTAKING FOR HAZARD SAFETY REQUIREMENT
To,
____
____
____
REF : Proposed work of ____
C.S.No./R.S.No. ____ Inward No. ____ at
House No. ____ Ward No. ____ situated at ____ street/road
____ ____ Village/Town/City
Certified that the building plans submitted for approval will satisfy the safety requirements as stipulated under Building Regulation No. ...and the information given therein is factually correct to the best of our knowledge and understanding.
It is also certified that the structural design including safety from hazards based on soil conditions shall be duly incorporated in the design of the building and these provisions shall be adhered to during the construction.
Signature of Owner with date ____
Name in Block Letters ____
Address____
____
____
Structural Engineer on Record with date
Signature of Developer with date ____
Name in Block Letters ____
Address______
Signature of the Architect on Record/Engineer on Record with date ____
Name in Block Letters ____
Name in Block Letters ____
Address____
____
Address____
____
Note : The certificate of Undertaking shall be signed by person concerned as per the provisions of Paras 2.3.1 and 2.3.2 FORM NO. 2 (see Regulation 4(iii) of the Nagaland Building Bye-Laws) (Appendix A Para 2.3.1 and 2.3.2)
Certificate of Undertaking of Architect on Record/ Engineer on Record
To,
____
____
Ref : Proposal work of ____
C.S.No.R.S.No./F.P.No. ____ Inward No. ____ at
House No._ Ward No._ situated at _
street/road
Village/Town/City
For____
Address: ____
Tel.No.: ____
I am a member of Council of Architects/Institution of Engineers (India) and I am possessing current registration to act as registered Architect/Engineer.
I hereby certify that I am appointed as the Architect on Record / Engineer on Record to prepare the plans, sections and details as required under the provisions of the Act / Development control Regulations for the above mentioned project and that I have prepared and signed the same and that the execution of the project shall be carried out under my direction, and supervision of a Construction Engineer on Record, as per the approved drawings. I am fully conversant with the provisions of the Regulations, which are in force, and about my duties and responsibilities under the same and I undertake to fulfill them in all respects, except under the circumstances of natural calamities.
I also undertake to provide my guidance for the adequate measure to be taken by the owners for installation of plumbing, drainage, sanitation and water supply. The appointment of a Construction Engineer on Record, building contractor, plumbing contractor and electrical contractor shall be made at the appropriate stage by the owner before the relevant work commences.
Signature :
Reg. No. ____ Date :
Name : ____
Address : ____
Tel. No.: ____
FORM NO. 3
(see Regulation 4(iii) of the Nagaland Building Bye-Laws)
(Appendix A Para 2.3.1 and 2.3.2)
Certificate of Undertaking of Structural Engineer on Record (SER)
To,
____
____
____
Ref : Proposed work of ____
(Title of the project)
C.S.No./R.S.No./F.P.No. ____ Inward No. ____
at Village ____ Taluka ____
Scheme No. ____ of ____
(Village/Town/City)
Owner:____
Address:____
Tel. No.: ____
I am a Registered Structural Engineer (RSE). This is to certify that I have been appointed as the Structural Engineer on record to prepare the Structural design basis report, detailed structural design and detailed structural drawings for above mentioned project. I am fully conversant of my duties and responsibilities under the Regulations and assure that I shall fulfill them in all respects.
I have prepared and signed a structural design basis report (SDBR).
I undertake to carry out a detailed structural design and prepare detailed structural drawings of the proposed building as per the latest Indian Standard Specifications, and as indicated in the Structural design basis report.
I undertake to supply the owner and the supervisor the detailed structural drawings. If my services are terminated, I undertake to intimate the Authority in writing.
Signature :
Reg. No. ____ Date :
Name : ____
Address : ____
Tel. No.: ____
FORM NO.4
(see Regulation 4(iii) of the Nagaland Building Bye-Laws)
(Appendix A Para 2.3.1 and 2.3.2)
Certificate of Undertaking of the Construction Engineer on Record
To,
____
____
____
Ref : Proposed work of
(Title of the work)
I possess a current Registration to act as Registered Construction Engineer.
I hereby certify that I am appointed as a Construction Engineer on Record on the above mentioned project and that all the works under my charge shall be executed in accordance with the drawings and specifications prepared for this project.
I am fully conversant with the provisions of the Regulations which are in force and about the Duties and Responsibilities under the same and I undertake to fulfil them in all respect.
* I undertake not to supervise more than ten works at a given time as provided in Development Control Regulations.
* I undertake not to supervise work simultaneously at one point of time on any other sites during my supervision of the execution of this work.
Signature:
Registration No......Date......
Name....
Address....
Tele.No....
FORM – 5 (see Regulation 12 of the Nagaland Building BYE-LAWS) (Appendix A Para 3.3.1) DEVELOPMENT PERMISSION
Ref. No. ____ Date ____ dated ____
for the grant of approval to construct / add / alter / repair of a building specified House No.
Ward No. ____ situated at ____.
Permission is hereby granted / refused under Section ____
to____
(Name of the person)
for____
(Description of work)
on the following conditions / grounds Conditions:
(in case of grant)
subject to the following conditions:
Prior permission for commencement of the building should be sought for on Form A obtainable from the Competent Authority.
The construction should be as per the approved plan and permissible without prior permission.
There should be enough provision for good sanitation and drainage system.
The land vacated in consequence of the reinforcement of the set back limit shall form part of public street.
No new building or part therefore shall be occupied of allowed to be occupied or used or permitted to be used by any person until permission has been granted in that behalf.
The excavated earth from the site shall not be dumped in public street, road, gully, etc.
Dumping of construction materials / spoils shall be made on any public places roads.
(in case of refusal)
a) Documents / N.O.C. etc.: -
Following documents / plans / N.O.C/ undertakings as mentioned in form no. ---- (application for Development permission) are not submitted.
b) Site Clearance: -
(i) Site is not cleared as per the provisions of Development Plan with respect to
- Road line
- Reservations
- Zone
- Other (specify)
(ii) Site is not cleared as per the provision of T.P. Scheme .... with respect to - Road
- Reservation
- Final plot
- Other (specify)
(iii) Proposed use is not permissible according to the width of road as per the provision No....
FORM NO. 6
(Appendix A Para 4.2)
FORM NO 7 (Appendix A Para 4.10.2 b)
Structural Design Basis Report
This report to accompany the application for Building Development Permission.
In case information on items 3, 10, 17, 18 and 19 can not be given at this time, it should be submitted at least one week before commencement of construction.
Part 1 General Data
Part 1 General Data
Part 1 General Data
Part 1 General Data
S.No.
Description
Information
Notes
1
Address of the buildingName of the buildingPlot numberSubplot numberTPS schemea. Nameb. NumberLocality/TownshipDistrict
2
Name of owner
3
Name of Builder on record
4
Name of Architect/Engineer on record
5
Name of Structural engineer on record
6
Use of the building
7
Number of storeys above ground level (including storeys to be added later, if any)
8
Number of basements below ground level
9
Type of structureLoad bearing wallsR.C.C frameR.C.C frame and Shear wallsSteel frame
10
Soil dataType of soilDesign safe bearing capacity
IS: 1893 Cl. 6.3.5.2IS: 1904
11
Dead loads (unit weight adopted)EarthWaterBrick masonryPlain cement concreteReinforced cement concreteFloor finishOther fill materialsPiazza floor fill and landscape
IS: 875 Part 1
12
Imposed (live) loadsPiazza floor accessible to Fire TenderPiazza Floor not accessible to Fire TenderFloor loadsRoof loads
IS: 875 Part 2
13
Cyclone / WindSpeedDesign pressure intensity
IS: 875 Part 3
14
Seismic zone
IS:1893 2002)
15
Importance factor
IS:1893 (2002) Table 6
16
Seismic zone factor(Z)
IS:1893 Table 2
17
Response reduction factor
IS: 1893 Table-7
18
Fundamental natural period - approximate
IS: 1893 Cl. 7.6
19
Design horizontal acceleration spectrum value (Ah)
Progress Certificate
Plinth Stage/In case of basement casting of basement slab
Reference No.
Owner's Name:
Submitted on:
Location:
Received on:
To,
____
____
____
Sir,
We hereby inform you that the work of execution of the building as per approved plan, working drawing and structural drawings has reached the Plinth Level and is executed under our supervision.
We declare that the amended plan is not necessary at this stage.
Yours faithfully,
Signature of the
Construction Engineer on Record
Signature of the
Owner/ Developer/ Builder
Date:____
Date: ____
Name in block letters: ____
Name in block letters ____
Address:____
Address ____
FORM NO. 8 (Appendix A Para 5.10.2 b)
Progress Certificate - First Storey
Reference No.
Owner's Name: Location:
Submitted on: Received on:
To,
____
____
____
Sir,
We hereby inform you that the work of execution of the building as per approved plan, working drawing and structural drawings has reached the first storey level and is executed under our supervision.
We declare that the amended plan is not necessary at this stage.
Yours faithfully,
Signature of the
Construction Engineer on Record
Signature of the
Owner/ Developer/ Builder
Date:____
Date: ____
Name in block letters: ____
Name in block letters____
Address: ____
Address____
____
____
____
FORM NO. 9 (Appendix A Para 5.10.2 b)
Progress Certificate - Middle Storey in Case of High-rise Building
Reference No.
Owner's Name:
Submitted on:
Location:
Received on:
To,
____
____
____
Sir,
We hereby inform you that the work of execution of the building as per approved plan, working drawing and structural drawings has reached ____ storey level and is executed under our supervision.
We declare that the amended plan is not necessary at this stage.
Yours faithfully,
Signature of the
Construction Engineer on Record
Signature of the
Owner/ Developer/ Builder
Date:____
Date: ____
Name in block letters: ____
Address: ____
______
Name in block letters____
Address____
____
FORM NO. 10 (Appendix A Para 5.10.2 b)
Progress Certificate - Last Storey
Reference No.
Owner's Name:
Submitted on:
Location:
Received on:
To,
____
____
____
Sir,
We hereby inform you that the work of execution of the building as per approved plan, working drawing and structural drawings has reached ____ storey level and is executed under our supervision.
We declare that the amended plan is not necessary at this stage.
Yours faithfully,
Signature of the
Construction Engineer on Record
Signature of the
Owner/ Developer/ Builder
Date:____
Date: ____
Name in block letters: ____
Address: ________________
Name in block letters____
Address____
FORM NO. 11 (see Regulation 13 of the Nagaland Building Bye-Laws) (Appendix A Para 4.10.2.4 d)
COMPLETION REPORT
Reference No.
Owner's Name:
Location:
Submitted on:
Received on:
To,
Sir,
I / We hereby give notice that I / We have completed the construction / reconstruction of the building in Plot No. ____ House No. ____ Ward No ____ in pursuance of the approval granted vide No. ____ Date ____
The work of erection/re-erection of building as per approved plan is completed under the Supervision of Architect/Construction Engineer who have given the completion certificate which is enclosed herewith.
We hereby declare that the plan as per the building erected has been submitted and approved.
Any subsequent change from the completion drawings will be our responsibility.
Yours faithfully,
(Developer's / Builder's Signature)
(Owner's Signature)
Name of Developer / Builder
Name of Owner
Date:
Address:
Encl: Completion Certificate
FORM NO. 12 (Appendix A Para 4.10.2.4 d)
Building Completion Certificate by Architect on Record
Reference No.
Owner's Name :
Submitted on :
Location :
Received on :
To,
____
____
____
Sir,
The building/s has/have been constructed according to the sanctioned plan.
The building/s has /have been constructed as per approved plan and design as per detailed architectural drawings and specifications prepared by Architect on Record.
Construction has been done under our supervision / guidance and adheres to the drawings submitted.
Signature of the Owner
Date
Signature of Architect on Record Date
Name in block letter:
Address : ________ ________________
Name in block letters:
Address: ____
______
FORM NO. 13 (Appendix A Para 4.10.2.4 d)
Building Completion Certificate by Construction Engineer on Record
Reference No.
Owner's Name : Location :
Submitted on : Received on :
To,
____
____
____
Sir,
The building/s has/have been constructed according to the sanctioned plan.
The building/s has / have been constructed as per - the detailed structural drawings and structural specifications prepared by the Structural Engineer on Record - the detailed Architectural drawings and Architectural specifications prepared by the Architect on Record. - detailed drawings and specifications of all services
All materials used in the construction have been tested as provided in specifications and a record of test reports has been kept.
Signature of the Owner
Signature of Construction
Engineer on Record
Date
Date
Name in block letter:
Address : ________
____________________________
Name in block letters:
Address: ________ ________________
IS: 1893 Cl. 6.4.2
20
♠ Expansion / Separation Joints
♥ Enclose small scale plans of each floor on A₄ sheets
♦ Incase terrace garden is provided, indicate additional fill load and live load
Indicate on a small scale plan on A4 sheet
FORM NO. 6 (Continued)
Part 2 Load bearing masonry buildings
S.No.
Description
Information
Notes
1
Building category
IS:4326 Cl. 7read with IS: 1893
Bldg Zone
II III IV V
Ordinary
B C D E
Important
C D E E
2
Basement Provided
3
Number of floors including Ground Floor (all floors including stepped floors in hill slopes)
4
Type of wall masonry
5
Type and mix of Mortar
IS:4326 Cl. 8.1.2
6
Re: size and position of openings (See note No.1)Minimum distance (b5)Ratio (b1+b2+b3)/l1 or (b6+b7)/l2Minimum pier width between consequent opening (b4)Vertical distance (h3)Ratio of wall height to thickness4Ratio of wall length between cross wall to thickness
IS:4326 Table 4, Fig.7
7
Horizontal seismic bandat plinth levelat window sill levelat lintel levelat ceiling levelat eave level of sloping roofat top of gable wallsat top of ridge walls
Vertical reinforcing barat corners and T junction of wallsat jambs of doors and window openings
☐ ☐ ☐☐ ☐ ☐
IS:4326 Cl. 8.4.8IS:4326 Cl. 8.4.9
9
Integration of prefab roofing/flooring elements through reinforced concrete screed
☐ ☐ ☐
IS:4326 Cl. 9.1.4
10
Horizontal bracings in pitched trussin horizontal plane at the level of tiesin the slopes of pitched roofs
☐ ☐ ☐☐ ☐ ☐
Notes
Information in item 6 should be given on separate A4 sized sheets for all walls with large number of openings.
P indicated "Information Provided"
TP indicates "Information to be Provided"
NA indicates "Not Applicable"
Tick mark one box
FORM NO. 6 (Continued)
Part 3 Reinforced concrete framed buildings
Part 3 Reinforced concrete framed buildings
Part 3 Reinforced concrete framed buildings
Part 3 Reinforced concrete framed buildings
Sl no
Description
Information
Notes
1
Type of Building · Regular frames · Regular frames with Shear walls · Irregular frames · Irregular frames with shear walls · Soft storey
IS: 1893 Cl. 7.1
2
Number of basements
3
Number of floors including ground floor
4
Horizontal floor system · Beams and slabs · Waffles · Ribbed Floor · Flat slab with drops · Flat plate without drops
5
Soil data · Type of soil · Recommended type of foundation - Independent footings - Raft - Piles · Recommended bearing capacity of soil · Recommended, type, length, diameter and load capacity of piles · Depth of water table · Chemical analysis of ground water · Chemical analysis of soil
Ductile detailing of RC frameType of reinforcement usedMinimum dimension of beamsMinimum dimension of columnsMinimum percentage of reinforcement of beams at any cross sectionMaximum percentage of reinforcement at any section of beamSpacing of transverse reinforcement in 2-d length of beams near the endsRatio of capacity of beams in shear to capacity of beams in flexureMaximum percentage of reinforcement in columnConfining stirrups near ends of columns and in beam-column jointsa. Diameterb. SpacingRatio of shear capacity of columns to maximum seismic shear in the storey
A certificate to the effect that this report will be completed and submitted at least one month before commencement
In addition to the completed report following additional information shall be submitted, at the latest, one month before commencement of Construction.
2.1 Foundations
2.1.1 Incase raft foundation has been adopted indicate K value used for analysis of the raft
2.1.2 Incase pile foundations have been used give full particulars of the piles, type, dia, length, capacity
2.1.3 Incase of high water table indicate system of countering water pressure, and indicate the existing water table, and that assumed to design foundations.
2.2 Idealization for Earthquake analysis
2.2.1 Incase of a composite system of shear walls and rigid frames, give distribution of base shear in the two systems on the basis of analysis, and that used for design of each system.
2.2.2 Indicate the idealization of frames and shear walls adopted in the analysis with the help of sketches.
2.3 Submit framing plans of each floor
2.4 Incase of basements, indicate the system used to contain earth pressures
FORM NO. 6 (Continued)
Part 4 Buildings in Structural Steel
Part 4 Buildings in Structural Steel
Part 4 Buildings in Structural Steel
Part 4 Buildings in Structural Steel
1
Adopted method of Design
O Simple
IS: 800; Cl. 3.4.4
1
Adopted method of Design
O Semi-rigid
IS: 800; Cl. 3.4.5
1
Adopted method of Design
O Rigid
IS: 800; Cl. 3.4.6
2
esign based on
O Elastic analysis
IS: 800; Section-9
2
esign based on
O Plastic analysis
SP: 6 (6)
3
Floor Construction
O Composite
3
Floor Construction
O Non-composite
3
Floor Construction
O Boarded
4
Roof Construction
O Composite
4
Roof Construction
O Non-composite
4
Roof Construction
O Metal
4
Roof Construction
O Any other
5
Horizontal force resisting system adopted
O Frames
Note: Seismic force
5
Horizontal force resisting system adopted
O Braced frames
As per IS: 1893Would depend on system
5
Horizontal force resisting system adopted
O Frames & shear walls
6
Slenderness ratios maintained
Members defined in Table 3.1, IS: 800
IS: 800; Cl. 3.7
7
Member deflection limited to
Beams, Rafters Crane Girders Purlins Top of Columns
IS: 800; Cl. 3.13
8
Structural members
O Encased in Concrete
IS: 800; Section-10
8
Structural members
O Not encased
9
Proposed material
O General weld-able
IS: 2062
9
Proposed material
O High strength
IS: 8500
9
Proposed material
O Cold formed
IS: 801, 811
9
Proposed material
O Tubular
IS: 806
10
Minimum metal thickness Specified for corrosion protection
O Hot rolled sections
IS: 800, Cl. 3.8
10
Minimum metal thickness Specified for corrosion protection
O Cold formed sections
Cl. 3.8.1 to Cl. 3.8.4
10
Minimum metal thickness Specified for corrosion protection
O Tubes
Cl. 3.8.5
10
Minimum metal thickness Specified for corrosion protection
Cl. 3.8.5
11
Structural connections
O Rivets
11
Structural connections
O C T Bolts
IS: 800; Section-8
11
Structural connections
O S H F G Bolts
IS: 1929,2155,1149
11
Structural connections
O Black Bolts
IS: 6639, 1367
11
Structural connections
O Welding-Field
IS: 3757, 4000
11
Structural connections
IS: 1363, 1367
12
Minimum Fire ratingProposed, with method
Shop(Specify welding type proposed)O CompositeO Rating ---- hoursO Method proposed- - In tumescent Painting- Spraying- Quilting- Fire retardant boarding
Building Completion Certificate by Structural Engineer on Record
Reference No.
Owner's Name : Location :
Submitted on : Received on :
To,
____________________
____________________
____________________
Sir,
This is to certify that detailed structural drawings of the buildings/s has / have been prepared on the basis of a detailed analysis and a detailed design carried out according to relevant previsions of the latest Indian Standard Codes, National Building Code and as indicated in the structural design basis report.
Signature of the Owner
Signature of Structural Engineer on Record
Date
Date
Name in block letters:
Address: ____
______
Name in block letters:
Address: ________
____________________________
Form NO. 15
(Appendix A Para 4.7.1)
Model Proforma for Technical Audit Report
(Quality inspection program to be carried out by Quality Auditor on Record (QAR) or Quality Auditor Agency on Record (QAAR) for high-rise buildings higher than seven storeys, public buildings and special structures in seismic zones IV & V).
Design
COMMENTS
1.1
Design/Drawings available?
Y/N
Design categoryType design?Specific design?
Y/NDesign to be collected to refer to Design Consultant/H.O.
Drawings prepared/checked by competent Authority?
Y/N
Design Drawings/detailsStructural detailed includedEarthquake/cyclone resistant features included?
Y/NY/N
Design verified/vetted by Dept./Govt. approved agency/competent authority?
Y/N
Design changes approved by dept./govt. approved agency/competent authority?
Y/N
Foundation
2.1 Foundation used
2.2.1 If existing foundation used
Existing/New
2.2.1 Depth of foundation below ground
2.2.2 Type of masonry
: <50cm/50-70/>70cm
: Stone/Bricks/PCC Blocks
2.2.3 Thickness of masonry (above ground) : 23cm/35/>35
2.2.4 Mortar used
2.2.5 Mix of cement mortar
: Cement-Sand/Lime/Mud
: 1:4/1:6/Leaner
2.2.6 Height up to Plinth
cm
2.2.7 If stone masonry
2.2.7.1 Through Stones
2.2.7.2 Corner Stones
: Yes/No, if Yes Adequate/Inadequate
2.3 If new foundation used
: Yes/No, if Yes Adequate/Inadequate
2.3.1 Depth of foundation below ground
2.3.2 Type of masonry blocks
<50/50-70/>70cm
2.3.3 Thickness of Masonry above plinth
: stone/bricks/PCC
2.3.4 Mortar used
: 23 cm/35/>35cm
: Cement – sand/lime/mud
2.3.5 Mix of cement mortar (1:4)
: Yes/No
2.3.6 Height up to Plinth
: <60/>60cm
2.3.7 If stone masonry
2.3.7.1 Through Stones
: Yes/No, if Yes Adequate/Inadequate
2.3.7.2 Corner Stones
: Yes/No, if Yes Adequate/Inadequate
2.4 Verticle reinforcement in foundation
: Yes/No
3 Walling
3.1 Type of masonry : Stone/Brick/PCC Blocks
3.2 Mortar used : Cement – Sand/Lime/Mud
3.3 Mix of cement mortar : 1:4/1:6/Leaner
3.4 Thickness of wall : >23cm/23cm/23cm
3.5 Mixing of mortar : OK/Not OK
3.6 Joint Property filled : OK/NOT OK
3.7 Wetting of bricks : Good/ Medium/ Poor
3.8 If stone masonry
3.8.1 Through Stones : Yes/No
3.8.2 Corner Stones : Yes/No
3.9 Overall workmanship : Good / Medium / Poor
4 Roofing
4.1 Type of roof : Flat/Sloping
4.2 If sloped : Morbid tiles/ A.C. sheet/ G.I. sheet
4.3 Purlins : Angle-Iron / Timber / NA
4.4 Truss type : _
4.5 Anchorage with wall : Adequate/ Inadequate/ NA
5 Materials
5.1 Cement
5.1.1 Source : Authorised Dealer/ Market
5.1.2 Type of cement : OPC/PPC/PSC
5.1.3 If OPC : Grade (33/ 43/ 53)
5.2 Sand
5.2.1 Type of sand : River sand / Stone dust
5.2.2 Presence of deleterious materials : Mild / Moderate/ High
5.3 Coarse Aggregates
5.3.1 Type coarse Aggregates : Gravel/ Crushed Stone
5.3.2 Presence of deleterious material : Mild/ Moderate / High
5.4 P.C.C. Blocks (Applicable for onsite production)
5.4.1 Type of P.C.C. Blocks : Solid blocks/Hollow blocks
5.4.2 Ratio of concrete in blocks : _
5.4.3 Interlocking feature : Yes/No
5.4.4 Course aggregates used : Natural/ Crushed stone
5.6.1. Mix of concrete : (1:1 ½:3)/ (1:2:4)/Design Mix
5.6.2 Batching : Weigh batching/Volume batching
5.6.3 Compaction : Vibrators/Thappies and rods
5.6.4 Workability : Low / Medium / High
5.6.5 Availability of water : Sufficient / Insufficient
FORM NO. 16 (Appendix A Para 4.11) STRUCTURAL INSPECTION REPORT
(This form has to be completed by registered Structural Designer after his site Inspection and verification regarding compliance of all recommendation by the owner, which in the opinion of the registered structural designer are necessary for safety of the structure. In case of building older than fifty years, the Structural Inspection Report shall be submitted to the Appropriate Authority within a year from the date of coming into force of these regulations.)
I. Description by title and location of the property including T.P.No., F.P.No. etc.:
II. Name of the present owner :
III. Description of the structure :
Class I or Class II (Briefly describe the property in general and the structure in particular)
(a) Function (b) Framed construction
Residence (with or without shops
Apartments (with or without shops
Office Bldg.
Shopping Centre
School, College
Hostel
Auditoria
Factory
1
2
3
4
5
6
7
8
A. Load bearing masonry wall construction
B. Framed structure
Construction and structural materials
Critical load bearing element
Brick
RCC
Stone
Timber
Steel
Roof Floor
RCC
Timber
RBC
Steel
Jack-arch
IV. Year of construction
Year of subsequent additions or rectification’s (Please describe briefly the nature of additions or rectification’s).
V. Date of last inspection report filed : Last filed by whom
(This does not apply to the first report).
VI. Soil on which building is founded :
i) Any change subsequent to construction
ii) Nearby open excavation
iii) Nearby collection of water
iv) proximity of drain
v) underground water-tank
vi) R.W. Pipes out-lets
vii) Settlements
VII. The Super-structure (R.C.C. Frame structure)
I) Crack in beam or column nature and extent of crack probable causes.
ii) Cover spell
iii) Exposure of reinforcement
iv) subsequent damage by user for taking pipes, conduits, hanging, fans or any other fixtures, etc.
v) Base plate connections with columns or pedestals
vi) Loading
IX. The Super-Structure (Load bearing masonry structure)
Cracks in masonary walls)
(Please describe some of the major cracks, their nature, extent and location, with a sketch, if necessary.
X. Recommendations if any :
This is to certify that the above is a correct representation of facts as given to me by the owner and as determined by me after Site Inspection to the best of my ability and judgment.
The recommendations made by me to ensure adequate safety of the structure are compiled with by the owner to my entire satisfaction.
(Signature of the Registered Structural Engineer Date:
Name of the registered structural Engineer:
Registration No. Address:
5.6.6 Curing : Satisfactory/Unsatisfactory.
5.7 Reinforcing Steel
5.7.1 Type of Steel : Plain mild steel/HYSD bars
5.7.2 Source : Authorised Dealer/Market
5.7.3 Whether IS marked : Yes/No
5.7.4 Conditions of bars : Clean/Corroded
5.7.5 Fixing of reinforcement as per drawing : Yes/No
5.7.6 Suitable cover : Yes/No
5.7.7 Spacing of bars : Regular/Irregular
5.7.8 Overlaps as per specifications : Yes/ No
5.8 Form Work
5.8.1 Type of Form Work : Timber / Plyboard/ Steel
5.8.2 Use of mould oil : Yes/No
5.8.3 Leakage of cement slurry : Observed/Not observed
5.9 Source
5.9.1 Cement
5.9.2 Sand
5.9.3 Coarse Agg.
5.9.4 Bricks
5.9.5 PCC blocks.
6 Seismic resistance features
6.1 Masonry Structures
6.1.1 Provision of bands at Provided Adequate
6.1.1.1 Plinth level Yes/No Yes/No
6.1.1.2 Sill level Yes/No Yes/No
6.1.1.3 Lintel level Yes/No Yes/No
6.1.1.4 Roof level (if applicable) Yes/No Yes/No
6.1.2 If sloped Roof, whether seismic bands are provide at
6.1.2.1 Gable wall top Yes/No Yes/No
6.1.2.2 Eaves level Yes/No Yes/No
6.1.3 Provision of vertical steel in masonry at Provided Adequate
6.1.3.1 Each corner Yes/No Yes/No
6.1.3.2 Each T-junction Yes/No Yes/No
6.1.3.3 Each door joint Yes/No Yes/No
6.1.3.4 Around each window Yes/No Yes/No
6.1.4 Openings
6.1.4.1 Total width of openings : <50%/50*-60%/>60%
(*-42% for double storey)
6.1.4.2 Clearance from corner : OK/Not OK
6.1.4.3 Pier width between two openings : OK/Not OK
6.2 Framed Structures
6.2.1 Ductile detailing
6.2.1.1 Spacing of stirrup : OK/Not OK
6.2.1.2 Sizes of members : OK/Not OK
6.2.1.3 End anchorage : OK/Not OK
6.2.1.4 Lapping (length, location etc.) : OK/Not OK
6.2.1.5 Angle of stirrup hook : 90 / 135 degrees
6.3 Any testing carried out by Owner/Engg. Supervisor on