A1. Protection of Areas from Earthquakes
(a) In those areas where there are no dangers of soil liquefaction or settlements or landslides, all building structures and infrastructures should be designed using the relevant Indian Standards as provided in the Building Regulations and the National Building Code
(b) Soils subjected to liquefaction potential under earthquake shaking can be improved by compaction to desired relative densities, so as to prevent the possibility of liquefaction.
(c) Buildings and structures could be founded on deep bearing piles going to non-liquefiable dense layers.
(d) Steep slopes can be made more stable by terracing and construction of retaining walls and breast walls, and by ensuring good drainage of water so that the saturation of the hill-slope is avoided.
(e) Any other appropriate engineering intervention to save the building structures or infrastructure from the fury of the earthquake.
Note : The protective action given under (b) to (e) will usually involve large amount of costs and should only be considered in the case of large and costly structures. For ordinary buildings the cost of improvement of the site will usually be uneconomical, hence bad sites should be excluded by Land Use Zoning.
A2. Protection from Cyclonic Wind Damage
(a) Buildings, structures and infrastructures in the cyclone prone areas should be designed according to the Indian Standards and Guidelines as provided in the Regulations and the National Building Code.
(b) Light utility structures used for electrical transmission and distribution, and towers for communications, chimney stacks of industrial structures require special design considerations against the cyclonic wind pressures, suctions and uplifts.
(c) In case the buildings, structures and infrastructures are founded on marine clay deposits it will be advisable to adopt either under-reamed or long piles which should penetrate the marine clay layer and rest on dense sand stratum, or individual column footing with a reinforced concrete beam located at the level of the ground, or a continuous reinforced concrete strip footing, using a very low bearing pressure not exceeding
(d) Wherever, the top soil could become slushy due to flooding, the top layer of 30 cm depth of soil should not be considered for providing lateral stability
(e) In storm surge prone areas, it will be preferable to construct the community structures, like schools, cyclone shelters, etc. by raising the level of the ground protected by provision of retaining walls at sufficient distance away from the building, taken to such depth that no erosion takes place due to receding storm surge. Alternatively, construct the community structures on stilts with no masonry or bracing upto the probable maximum surge level.
A3. Protection of Areas from Floods
This may require one or more of the following actions.
(a) Construction of embankments against the water spills from the source of flooding like rivers, large drain etc.
(b) Construction of high enough embankments/bund around the planning area.
(c) Raising the planning area above the high flood level.
(d) Construction/improvement of drainage paths to effectively drain the water from the planning area.
(e) Construction of buildings and structures on deep foundations going below the depth of scour or on stilts with deep enough foundations under water.
(f) Flood proofing works such as the following:
(i) Providing Quick Drainage facility, consisting of
Revitalization of secondary and primary drainage channels after establishing the drainage blockage points;
Provision of additional waterways;
• Clearing of clogged cross drainage works;
Providing Human and Animal Shelters for population living within embankments in the form of raised platform or use of available high ground.
(g) Anti-erosion actions in affected areas
(h) Any other suitable measure.
Note: 1. Similar protection methods could be used against flooding caused in cyclone prone areas by high intensity rains or by the storm surge.
- The concept of land zoning should be kept in mind for areas where protection works are taken up to decide inter-se priority for location of structures considering possibility of failure of protection works during extreme disaster events.