158Application for approval of sites and for permission to construct or reconstruct buildings other than huts.—
(1) Before submission of the building plan, approval of the building site has to be obtained,
Note.—The applicant may simultaneously submit the site plan and building plan to the Municipality for approval at his own risk and cost. But the Municipality shall consider the building plan submitted for approval only after the site plan is approved. In case the site plan is not approved, the submitted building plan shall also be treated as not approved.
(2) Application, under sub-rule (1) submitted in Form A, shall state inter alia the proposed use of the land as per use group provided in the Act.
(3) Every application, specified in sub-rule (1) shall be accompanied by a site plan in triplicate and the reports and/or recommendations of tests for soil and stability of slopes, as and where applicable under rule 157 together with a fee as specified in rule 4. The site plan shall be drawn to the scale of not less than one centimeter to six meters and shall be signed by the applicant and by the Licensed Building Surveyor or Architect as required under rule 161 with a certificate to the effect that the site has been inspected personally by the Licensed Building Surveyor or the Architect, as the case may be.
[PART I
(4) Every site-plan specified in sub-rule (3) shall show or state on the body of the sheet showing the site plan the following:—
(a) the boundaries of the building site and of any contiguous land belonging to the owner thereof with number assigned to the plot or the premises;
(b) the position of the building site in relation to neighboring streets with dimensions;
(c) the name of the street on which the building site abuts;
(d) the position of the proposed building and of all other buildings including existing buildings (if any) which the applicant intends to erect upon his contiguous and referred to in clause (a) in relation to—
(i) the boundaries of the building site and, in case where the site has been subdivided, the boundaries of the portion owned by the applicant and also the portions owned by the other owners, and
(ii) all adjacent streets, buildings and premises within a distance of 12.00 meters of the building site and of the continuous land (if any) referred to in clause (a);
(e) the use or occupancy of all the buildings;
(f) the direction of North Point;
(g) the means of access from the street to the proposed building and to all other buildings (if any) which the applicant intends to erect upon his contiguous land referred to in clause (a);
(h) the schematic position and approximate height and the number of storeys of all other buildings within 12.0 meters from each side of the building site;
(i) the free passage or way in front of the building;
(j) the width of the street (if any) in front and at the rear of the building;
(k) the means of drainage of the proposed building leading to existing public drains or drainage channels with their location in relation to the building site;
(1) the means of drinking water supply to the proposed building indicating the source and the distance from the site including the route through which the pipeline will be laid, if piped water supply is envisaged;
(m) the means of power supply to the proposed building on the site, indicating the route through which power supply will be achieved;
(n) areas of distress;
(o) such other particulars as may be specified by the Board of Councillors;
(p) the location of power line, water line, sewer line, natural drainage channel or jhora, road side drain, protective works;
(q) location of land slides, if any, on or near the building site in hill areas detected during reconnaissance. The Board of Councillors shall cause to ensure that the building site is away from the slide zone or areas of distress;
(r) on a sloping building site in hill areas, proposals for diversion of the natural flow of water coming from uphill side of the building away from the foundation.
Part XISpecial Provision for Municipalities in the Hill Areas
156 Special Provisions.—
Notwithstanding anything contained elsewhere in these rules, the special provisions of this part shall apply only to the Municipalities or Notified Area Authorities in the hill areas and shall be construed to be in modification of, or to supplementing, the other provisions elsewhere in these rules in their application to the Municipalities or Notified Area Authorities in the hill areas. Anything not covered under the special provisions shall be guided by the provision made elsewhere in these rules or the Act.
Criteria of using a piece of land as a building site.—
(1) No piece of land shall be used as a building site, unless the Board of Councillors is satisfied that—
(a) land record is in conformity with the proposed construction;
(b) the site of such building abuts an all weather public street or a projected public street or a private street or footpath or passage and is not less than 1.50 meters wide at any part, duly sanctioned and constructed and recorded in the Books of Municipality in accordance with the provisions of the Act or any other law in force immediately before the commencement of the Act:
Provided that no building shall be erected so as to deprive any other building or building site of the means of access as specified above;
(c) the site is at least 100 sq. meters in area;
(d) the land is capable of being well drained by means of drainage facilities leading to the existing public drainage channel or jhora or under course of natural drainage line;
(e) the site is reasonably secured from danger from hillside slips from above, below, or the sides;
(f) the soil of the site is likely to sustain the construction of a building thereon; and, for sites with inclinations of 30° and above or for proposed building above 6.5 meters in height or 500 sq. meters in coverage, such sustainability shall be justified, at the cost of applicant, by prior testing of soil and certification of stability of slopes and buildings conforming to the relevant codes of Bureau, of Indian Standards including—
65
(i) BIS : 2070 : IS Code of practice for design and construction of shallow Foundation on rock;
(ii) BIS : 3063 : IS Code of practice for structural safety of building on shallow Foundation on rock;
(iii) BIS : 4243 (Parts I & II) : Selection and development of site in hill areas-guidelines.
Note.—Detailed geotechnical investigations, testing and certification, in such cases, shall be carried out by a competent geotechnical engineering organization or firm, recognized by the Board of Councillors.
Explanation: soil will also include rocks, boulders, laterite.
(g) the building site does not contain any portion which forms a component of the open spaces prescribed under the regulations for any other building or building site thereof;
(h) (i) no part of the land is located within 200 meters from the boundary of a sinking zone or probable slip zone, designated in a meeting by the Board of Councillors; or,
(ii) within an area of distress or possible unequal settlements with wide fissures, regular cracks, faults, voids, rock, debris or landslides caused by subsidence or erosion, filling and disposal dumps including solid waste disposal or organic materials, or;
(iii) it is located within an area showing high water table and fully saturated soils with a possibility of liquefaction and settlement on exposure to earthquakes or of water seepage in the foundations and erosion, or,
(iv) any other vulnerable area identified by the Board of Councillors, as unsafe for environmental, geological, ecological, wind, drainage or any for other reasons;
(i) no piece of land is located within five meters in any direction of the outside edge of such water courses;
(j) adequate drainage measures and protection work as specified in rules 166 and 167 shall be taken by the applicant at his own cost if it is located on the permanent shadow zones of ridges and spurs or at the bottom of the valleys or gorges or located by nature of its orientation in a zone as identified by the Board of Councillors to be inadequately sunlit so as to make it unfit for human habitation, if any;
(k) the site has not been subject to repeated blasting or, was a former quarry;
(1) where the site is within five meters of any side of a tank, the owner will take such measures as shall prevent any risk of the drainage from such building passing into the tank;
(m) where the site is within five meters of any side of a tank, water reservoir, jhora or natural spring, water source or natural drain or within two meters from either side of water pipe, sewer line and/or other underground utilities, the owner shall take such measures at his own cost, which shall prevent any risk of damage or landslide thereto by construction of such buildings.
Note.—The distance shall be measured from the outside edge of the jhora or drain or pipeline, as the case may be, on either side. In case of jhoras, such protection measure shall also have to be taken by the owner, at his own cost if the site is within 30 meters of jhora;
(2) No piece of land located in Central business area as determined by the Board of Councillors or in sinking zone or areas of distress with cracks caused by subsidence or slides or any other areas identified by Board of Councillors, with reasons to be recorded in writing, shall be used as a building site without prior approval of the State Government.
(3) No piece of land where a closed, sick or other industry was located or is in operation, shall be used as a site for construction of any building, other than an industrial building, without the prior approval of the competent authority appointed under clause (d) of section 2 of the Urban Land (Ceiling and Regulation) Act, 1976 (33 of 1976).
160Preparation of plan and supervision of execution of work.—
(1) Every owner who intends to erect, re-erect, add to, or alter, any building, shall get its plan prepared and structural work designed and supervised by an architect or structural engineer or licensed building surveyor or Geo technical Engineer as required under rule 161. While submitting the plan, the architect or licensed building surveyor or structural engineer or Geo technical engineer shall certify to the effect that the site has been personally inspected by him while planning for the building and/or designing the structural members, as well as he has taken into account the findings and/ or recommendations of stability analysis as well as soil tests performed as and where necessary under this rule.
(2) In all such cases, the licensed building surveyor, structural engineer or geo technical engineer shall have to be empanelled with the Municipality.
(3) The name, address and license or empanelment number of the person so employed and serial number in the case of architect shall be stated in the application in respect of such building.
(4) In case of site plans or building plans submitted by the Central Government or the State Government or by organization controlled by the Central Government or the State Government, the plans prepared and submitted under the signature of a Government engineer or Government architect, who are employees of the Central Government or the State Government or the organization control by the Central Government or the State Government, sub-rule (1) shall not be applicable.
159Sub-division of plots.—
(1) No sub-division of any plot within the municipal area shall be undertaken without the prior approval of the Board of Councillors.
(2) (a) A plot to be sub-divided shall be termed as mother plot;
(b) every individual plot obtained by sub-division of the mother plot shall abut a means of access having width of not less than 2.00 meters;
(c) this rule shall not apply to a scheme for Economically Weaker Section and Low Income Group Housing approved by the Government;
(d) sub-division may be allowed on the condition that the following facilities shall be provided by the owner at his own cost to the satisfaction of the Board of Councillors:—
(i) complete drainage facilities in accordance with provisions made elsewhere for the hill areas, ensuring drainage of each individual plot and of the means of access and passages leading to existing public drains or natural drainage channels,
(ii) all weather means of access with related protective works, if necessary, along with street lighting,
67
(iii) sanitary facilities including sewage and garbage disposal facilities,
(iv) water supply facilities,
(v) electricity and telecommunication facilities,
(vi) all individual plots as well as the means of access and infrastructure provided shall be accompanied by complete protective measures in accordance with provisions made elsewhere for hill areas in these rules,
(f) no permission for sub-division of a plot of land shall be granted unless each sub-divided plot is at least 80 sq. meters in area;
(g) no sub-division of a plot shall be granted unless a detailed layout plan or the area proposed to be sub divided is submitted before the Municipality duly integrating the site layout plan with the general use of the land in the adjoining areas. The existing street pattern as also other physical infrastructural facilities like drainage, sewerage, water supply, electric supply with location of high tension or low tension electric line with poles are also required to be shown.
(3) The mother plot shall abut an all weather means of access conforming to the conditions specified below:
(a) the means of access shall have a width of not less than 2.0 meters, for plots having an area less than 500 sq. meters and a width not less than 3.0 meters for plots having an area more than 500 sq. meters:
Provided that an emergency vehicular access (minimum 3 m wide) shall be available within a distance of 100 m from the mother plot;
161Engagement of technical personnel.—
(1) Every person who intends to erect, re-erect, add to, or alter, any building shall, subject to the provisions of the Act and these rules, engage,—
(a) for all building up to 6.50 meters in height, a technical personnel not below the rank of a licensed building surveyor for planning, designing and construction of the building foundation and superstructure, and for all buildings above 6.50 meters but below 13.50 meters in height and/or for erection involving piling works, deep foundation or construction of basement or any other underground structure thereto, a licensed building surveyor and/or an architect and a structural engineer and a geo-technical engineer for conducting soil test and other tests as required under rule 157(f), planning, designing and construction of the building foundation and superstructure;
(b) a licensed building surveyor who shall have—
(i) a minimum Bachelor degree in civil engineering. Construction Engineering or Architecture from a recognized university or its equivalent qualification recognized by the Government and shall not have less than two years experience in planning, designing and execution of building works including sanitary and plumbing works related to buildings under geo-technical condition similar to that of hill areas, or
(ii) a minimum diploma in Civil Engineering or Architecture from a recognized university or its equivalent qualification recognized by the Government and shall not have less than five years experience in planning, designing and execution of building works including sanitary and plumbing works related to buildings under similar geo-technical condition similar to that of hill areas;
(c) a Structural Engineer who must have a minimum Bachelor degree in civil engineering or construction engineering from a recognized university or its equivalent with at least five years experience (including two years in hill areas) in structural design;
(d) a Geo-technical Engineer who must have a minimum bachelor degree in civil engineering or construction engineering from a recognized university or its equivalent with at least two years experience in soil engineering and foundation engineering under identical soil/slope/geo technical conditions.
(2) The licensed building surveyor, the architect, the structural engineer and the geo-technical engineer will work in association with one another and will be individually and/or collectively responsible for ensuring the safety of the building structure and its foundation.
162Permissible height of building.—
(1) The maximum permissible height of a building as well as its permissible floor area shall be regulated by the width of the surrounding open space in the same holding plus the width of its means of access, depending on the type of building use as per the table below:—
Floor Area Ratio (FAR):
width of means of access plus width of front open space
Up to 3.0 m
3.0-5.0 m
5.0-7.5 m
above 7.5 m
Residential
1.0
2.0
2.5
2.75
Commercial, Public and other uses
1.0
1.5
2.0
2.5
Maximum permissible height
4.5 m
6.5 m
11.5 m
13.5 m
Provided that in case a building is more than 11.50 meters in height, prior approval of the State Government is required to be obtained.
Note.— For buildings of residential (excluding a height of 6.5 meters), commercial, public and other uses the means of access of at least 3 metre wide should be available within a distance of 100 meters of foot-path length from the proposed plot.
(2) (a) The following appurtenant structures shall not be included in the height of the building:—
(i) stair cover not exceeding 2.40 meters in height;
(ii) lift machine rooms as per the latest edition of the National Building Code;
(iii) roof tanks and their supports, the height of support not exceeding 1.00 meters;
(iv) chimneys;
(v) parapet walls not exceeding 1.50 meters in height;
(vi) ventilating, air-conditioning and other service equipment;
(vii) height above mid-point between eaves level and ridge level;
(b) The aggregate area of the structures mentioned in clause (a) shall not exceed one-third of the area of the roof upon which these are erected.
(3) The Board of Councillors may, if necessary, restrict the height of building in any area within the municipal limits, below that provided sub-rule(l) for reasons to be recorded in writing.
163 Ground coverage.—
164Open spaces for building.—
(!) The following shall be the open spaces of the buildings:—
(a) every room intended for human habitation shall abut an interior open space or exterior open space or an open verandah open to such interior open space or exterior open space. Open spaces shall be areas forming integral parts of the plot at ground level and shall be open to sky without any projection or overhang excepting cornices, chajjas or weather-shades of not more than 0.50 metre width;
[P AR T I
(b) every building shall have exterior open spaces comprising front open space, and side open spaces. The minimum width prescribed for front open space, rear open space and side spaces shall be provided along the entire front, rear and side faces of the building respectively. For this purpose the front of the building shall be that face of the building which faces the means of access of the building and the rear of the building is that face of the building which is farthest from the means of access. These provisions shall also be applicable to each individual building separately when a plot contains more than one building. In the case of a corner plot located at the crossing of more than one street or passage, the rear of the building shall be deemed to be that face of the building which is farthest from the widest of all such streets and/or passages;
(c) open spaces prescribing to one site cannot be taken for another site. No building shall at any time be erected on any open space prescribed in this rule for a building and form part of the site thereof, nor shall such open space be taken into account in determining the area of any open space required under these rules for any other building;
(d) if the front open space is 3.00 meters or more in width, a Gate Goomti for security purpose may be allowed in the said open space. The covered area of such Goomti shall not in any case exceed 3.00 sq. m. and the height of such Goomti shall not exceed 3.00 meters. The covered area of the Gate Goomti shall not be included in calculation of ground coverage.
(2) The minimum front open space, rear open space and side open space shall be provided along the entire faces or sides of the building as given in the table below:—
Minimum width of open space in meters
Minimum width of open space in meter
165Access, circulation and parking.—
(1) Every plot shall abut a means of access which may be a public street or private street or passage, the minimum width of which shall be as specified in rule 157(l)(b).
(2) No building which in full or part is put to assembly occupancy for the purposes of theatre, motion picture house, city hall, skating-rink, auditorium, exhibition hall or for similar other purposes shall be allowed on a plot located within 50 meters of the junction of two streets, the width of which is of 8.0 meters or less.
(3) Every building on a plot having more than one building shall abut an internal road connecting the means of access of the plot and such roads shall conform to the requirements of internal roads specified in rule 159.
(4) Number of Car Parking Spaces as per Covered Area of plot and Use Group shall be as follows:—
Residential and Educational uses
I Car Space per 300 sq. meters
Commercial, Public and other uses
I Car Space per 200 sq. meters
Note.—In case of a plot having more than one building or use, parking requirements shall be calculated according to the proportionate floor area of each building or use group, as the case may be.
(5) For plots abutting non-vehicular means of access less than 3.0 meters in width, car parking space need not be provided within the plot area but space with vehicular access has to be identified and owned by applicant for the required parking or garage space, as per this rule.
(6) The parking space for each vehicle shall be accessible from the means of access, either directly or through a driveway or internal circulation, aisle, the width of which shall not be less than 3.5 meters for cars and 5.0 meters for trucks and the gradient of which shall not be more than 1:6.
(7) The minimum size of a car parking space shall be 2.50 meters x 5.00 meters and that for a truck or bus parking space shall be 3.75 meters x 10.00 meters. These spaces do not include the area of circulation, internal roads, aisles and driveways, and standards for these shall be guided by provisions in the National Building Code.
(8) No garage for cars shall be less than 2.5 meters x 5.0 meters (clear size) with a minimum head room of 2.25 meters and no garage for trucks shall be less than 3.75 meters x 10.00 meters (clear size) with a minimum head room of 3.50 meters.
167Protective work in hills.—
(1) The cutting of slopes in the creation of steps and terraces for development work shall be carried out while ensuring the stability of excavations to provide for the safety of the buildings located and constructed thereon in accordance with the provisions in the BIS Codes.
(2) Local ground conditions shall be taken into account in the determination of the appropriate precautionary work and protection walls such as revetments, retaining walls, toe walls and breast walls as well as the specifications of the relevant codes of practice of the Bureau of Indian Standards including BIS 14243-Part I & 11 : Selection and development of site for building in hill areas guidelines.
(3) (a) The maximum height of cutting for development work as per soil strata shall be as given below:—
Loose soil or boulders with soil matrix
4.0m;
Compact soil or boulders with soil matrix overlaying loose, soft, fractured of firm hard rock strata which remains vertical in 4 m high cutting when dry
6.0m;
Hard stable rock with or without compact soil or boulder with soil matrix up to 2 m thick
8.0m;
(b) Cutting of slopes over a height of 6.0 meters shall not be ordinarily permitted, excepting with the special approval of the Board of Councillors.
(4) (i) The foundation of every protection wall must be taken down to original and firm soil or rock, have a bed-line cut at right-angles with the face of the wall and a slope of 3 : 1 towards the hillside;
(ii) (a) Where a protection wall does not exceed 6.0 meters in height and is not surcharged, the mean thickness of the revetment or wall above the footings shall not be less than one-third of the vertical height of the revetment or wall, measured from the top of the footings,
(b) Where a protection wall does not exceed 6.0 meters in height and is surcharged, the height assumed for the determination of mean thickness of the revetment or wall above the footings shall be one and a half times the actual vertical height:
Provided that the width at the top shall in no case be less than 0.5 metre and shall not in any case exceed 1.0 metre,
(c) No structure shall be allowed to be raised from the top of the retaining wall or protective wall;
(b) the minimum permissible width for any given length of means of access for sub-divided plots shall be as given in the following table:—
Length of internal road
Minimum width of means of access
Up to 25.00 meters
1.5 meters (pedestrain pathways only)
Above 25.00 meters up to 50.00 meters
3.0 meters
Above 50.00 meters up to 100.00 meters
4.5 meters
Above 100.00 meters
6.0 meters
(c) Sub-division of a mother plot measuring more than 500 sq. meters in area shall only be allowed if a proportion of the total area of the mother plot is developed as public amenities or open space, as specified in the table below.:—
Size of plot to be sub-divided
% of area to be reserved for public amenties or open space (excluding roads)
Above 2000 sq. meters and below 5000 sq. m
7.5
5000 sq. meters and above
10.0
Note.—This shall be in addition to the land required for providing the means of access to the individual plots obtained by sub-division of the mother plot as specified in this rule.
Moreover, each such space in a single parcel shall have minimum areas of 150 square meters and a minimum width of not less than 3.00 meters; and each such open space shall abut a means of access as specified in sub-rule (3) of this rule.
(4) For mother plots measuring more than 5000.00 sq. meters in area, sub-division may be allowed if an additional five percent of the total area of mother plot is reserved for use or facilities like school, health centre, market, police outpost, milk booth, post office, power sub-station, transport terminal, water tank for fire fighting or water treatment plant, sewage treatment plant and the like. Such land shall abut a means of access as specified in this rules. This is in addition to the land necessary for means of access as specified in sub-rule (3) and for public amenities and open spaces specified in this rule.
[PART I
(3) The licensed building surveyor, structural engineer or a geo-technical engineer is also required to be empanelled with the Municipality. Duties and Responsibilities of Licensed Building Surveyor, Architect, Structural Engineer or Geo-technical Engineers will be governed by rules 16, 17, 18 of these rules.
(4) In case of death, resignation or removal of Licensed building Surveyor, Architect, Structural Engineer or Geo-technical Engineer, as the case may be, a fresh engagement shall be made forthwith and shall be notified to the Chairman of the Municipality. No work shall be carried out till such engagement is made.
(5) The validity of any engagement made under this rule shall lapse, in the case of an architect with lapse of validity of registration granted under the Architect's Act, 1972 (20 of 1972), or in case of a structural engineer and a geo-technical engineer with the lapse of empanelment, or in the case of a licensed building surveyor, with lapse of the validity of license.
69
The maximum permissible ground coverage for buildings when a single building is proposed for a plot shall be regulated by the plot size, depending on the type of building use as given in the table below:—
Plot Size
Maximum permissible ground coverage
100-400 sq .m
400-1200 sq. m
Over 1200 sq. m
Residential and Educational uses
70%
60%
50%
Commercial, Public and other uses
60%
50%
40%
Front
Rear
Side
Residential and Educational uses
1.5 m
1.5 m
1.5 m
Commercial, Public and other uses
2.5 m
3.5 m
3.5 m
Provided that the minimum clearance, on all the sides between a building wall and the toe of a retaining or other protective wall shall be 1.50 meters, except on the side where the septic tank shall be installed, in which case, the minimum clear distance of 2.1 meters shall be provided:
Provided further that for mixed use buildings, the minimum front open space shall be the one applicable for that particular occupancy which gives the provision of the minimum front open space in these rules:
Provided also that for a building of more than 11.00 meters in height, the minimum open spaces provided in this rule shall be increased by 0.3 metre in all cases.
(3) Notwithstanding anything contained elsewhere in this rule in the case of a building with a septic tank, a side open space of 2.1 meters shall be provided on any one side of the building for the provision of the said septic tank.
(4) In the case of a building more than 25.0 meters in depth, a passage of width not less than 3.5 meters shall be provided along the entire depth of the building.
(5) For plots of size not more than 65 (sixty-five) sq. meters, minimum side space of 0.90 metre may be allowed on each side provided the building height does not exceed 6.5 meters.
Explanation.—
(i) Notwithstanding anything contained in this rule, the minimum distance across the side open space from every new building to an existing building with a door opening or window opening shall be 1.80 meters;
(ii) Notwithstanding anything contained in this rule, the minimum width of side open space for an industrial or storage or mercantile (wholesale) building shall be 3.50 meters;
(iii) In the case of a building more than 24.00 meters in depth on a plot abutting any street, a passage along the entire depth of the building shall be provided and the minimum width of such passage shall be 4.0 meters.
(6) The interior open space shall be as follows:—
(a) for inner courtyard,—
in case the whole of one side or part of at least two sides of every room excepting bath, water closets and store-room is not abutting either the front open space, rear open space or side open space, it shall abut an inner courtyard whose minimum width shall be 30% of the height of the building or 3.00 meters, whichever is more.
(b) for ventilation shaft, that is to say,—
for ventilating water closet, bathroom and kitchen such water closet or bath room or kitchen if not opening to front open space, side open space, rear open space or interior open space, shall open on to a ventilation
71
shaft, the size of which shall not be less than the values given below:
Height of building (meters)
Minimum area of ventilation Shaft (sq. meters)
Minimum width of shaft (meters)
Up to 11 .50
1.50
1.00
Above 11 .50 but not more than 12.50
3.00
1.20
Note.—No chajja shall be allowed in the ventilation shaft unless the width of shaft is 2.40 meters or more.
(c) the minimum width shall not be less than 20% of the height of the building or 2.50 meters, whichever is more.
(7) The service rooms shall have access by means of two passages of staircases, providing access and exit from higher and lower level floors, the width of which shall not be less than 1.2 meters and the slope shall not be steeper than one 1:1 and so located that the travel distance on any floor up to any such access or exit is not more than 15.0 meters.
(8) Mezzanines are to be used strictly for purposes other than habitation or kitchens and eating places and may be provided between any two floor and shall be permitted with a minimum clear height at every part of at least 2.0 meters measured from the floor to the lowermost point on the underside of the roof, slab, beam or false ceiling. The area of such mezzanines shall be included in floor area in all calculations.
(9) (a) An internal road must be so constructed as to have a slope inwards towards the hillside. Such slope must be not less than the gradient of the road;
(b) Where required, the inner and outer edges of an internal road must be protected by protective walls of such number and placed in such positions as the Board of Councillors may direct and constructed in accordance with the specifications in this rule.
[PART 1
Drainage measures.—
(1) (a) An open drain must be provided on the inner side of an internal road, constructed in accordance with the specifications in this rule.
(b) An effective slope and drainage system shall be maintained at all times on the developed ground after slope cutting or filling, during and after development as per this rule on any site;
(c) The drainage system shall efficiently collect and carry away from the site the water collected within the premises of the building complex or from the hillside above for suitable disposal as quickly as possible to water courses such as main drains or natural streams/jhoras without stagnation avoiding any possibility of erosion, slope failure, damage to the building or other property in the vicinity.
(2) (a) Proper slopes, not less than 1: 60 shall be maintained all around a building for quick drainage of the entire plot as provided in this rule.
Note.—The possibilities of erosion or ground failure through ingress and percolation of water into soft ground or through joints and fissures in the soil crust shall be prevented by suitable surface protection measures such as surface grouting, stone pitching, planting of small plants and grass, so as to protect and make the surface impervious in accordance with the provisions of the BIS Codes, specially the minimum distance from provision required to be maintained for planting trees;
(b) The flow of water, particularly on the upper side of the building, shall be diverted away from the foundations through suitable lined or unlined drains;
(c) Drains for sullage or rain water must be constructed with round or half round tiles embedded in concrete, or with V-shaped stone masonry set in lime mortar and plastered over the inner surface with Portland cement, or with V-shaped stone concrete and the sectional area of every drain shall be subject to the approval of the Municipality; .
(d) Drains for surface water may be constructed only either of dry rubble masonry or of any other material approved by the Board of Councillors, and may be either rectangular or V-shaped in section. Such drains shall not be connected with any drain carrying sullage water or sewage;
(e) Except with the written permission of the Board of Councillors, no covered drain .shall be constructed and no existing open drain shall be covered in;
(f) No building shall be placed to cover any drain;
(g) Where a small drain is crossed by a private road, a removable R.C.C. slab cover or wooden grating or iron grating, if the Board of Councillors so direct, must be laid over the drain instead of a covered culvert.
(h) Drains must discharge into the nearest water channel or public drain, unless in any case the Board of Councillors otherwise direct. The outfall of a drain into a water channel or public drain must be protected and guided in such manner as the Board of Councillors may direct. Where the drain of a private road joins the drain of a public road, the former drain must be so directed or so protected by strike-boards as to minimize the risk of damage to the public drain or road. Filters may also be provided where necessary;
(i) Every building must be constructed so as not to project over, or admit of water from the roof falling upon or damaging, any open space, road or passage it abuts, whether public or private;
(j) Every building shall have rain water gutters and pipes connected to a drain along the periphery of a building;
(k) A masonry drain must be placed round the periphery of every building or block of buildings, sufficient in section and slope to the satisfaction of the Municipality for the effectual drainage of the building and be placed as to admit the drainage being led into some drain at the time existing or projected;
(1) The surrounding ground adjacent to the building must be sloped from all sides towards the perimeter drain and an impervious apron, not less than 0.75 m wide, shall be provided all around the building to prevent the entry of water into the foundations.
(3) (a) Septic tank and soak pits shall be so located so as to be easily accessible from the means of access to the plot;
(b) Soak pits may be constructed on the side of buildings at right angles to the slope of the land and from the building foundations. There shall be a minimum clearance of 2.1 meters between the foundation and the soak pit to minimize the chances of dampness and slope failures due to seepage from the soak pit.
(4) (a) A private bridge must be constructed as and where necessary to the satisfaction of the Municipality so as to leave sufficient waterway to pass the maximum discharge of the channel spanned by the bridge.
73
(b) The invert of the channel under a private bridge must be laid to the same slope as that of the channel;.
(c) When a pocket for the deposit of debris is cut in the hillside above a private bridge, it must be lined with masonry walls unless constructed on solid rock.
(iii) (a) A protection wall may be of dry rubble masonry, or cement masonry as per the directions of the Board of Councillors,
(b) Dry stone masonry protection walls shall include cement masonry bands in 1 : 4 cement sand mortar of 0.4 to 0.6 metre thick at top and bottom, and vertically at 3.0 to 5.0 meters spacing,
(c) No stone used shall be of greater height than its length or breadth. All stones used must be laid on their natural beds, and must be arranged so as to break joint.
(d) Every protection wall must be built up solid to full section and spawls or chips shall not be used for filling the courses unless their use is unavoidable;
(iv) one thorough bonding stone or line of bonding stones must be inserted at intervals at 1.50 meters in each course and at points intermediate between the corresponding bonding stones of the course below
Note.—Any of the bonding tones which do not extend right through the wall must overlap each other of one-third of their length.
(v) (a) Special investigations and analysis shall be carried out to determine the details of protection works in the case of R.C.C. retaining walls or protection walls on steep cut slopes greater than 6.0 meters in height, or in case of fine soils like silt, clay or shales,
(b) In all such cases, detailed designs must be submitted to the Board of Councillors and the sections must be such as the Board of Councillors may approve,
[P AR T I
(c) Protection walls of height more than 6.00 meters and successive retaining walls shall only be permitted when there is hard stable rock behind and below the toe of the said wall as permissible under relevant BIS Code of Practice;
(vi) The height of cutting for any step of a stepped building shall not be more than 4 m and successive protection walls shall only be permitted when there is hard stable rock behind and below the toe of every such wall;
(vii) (a) Weep-holes shall be provided in breast walls and retaining walls equipped with graded filter for proper drainage at intervals of 1.2 meters horizontally and 1.2 meters vertically in a staggered manner and beginning from 0.20 metre above ground level,
(b) Water along the base of a breast wall and retaining wall shall be drained out by means of a suitable lined drain forming an integral part of the drainage system as specified in rule 166;
(viii) When a slope determined to be vulnerable to a debris slide in pursuance of any requisition or direction made or given by the Board of Councillors, the angle of a slope shall be reduced to an angle of not more than 30° to the horizontal plane through trimming or cutting to make the slopes stable along with minor protection both for soil and building work.
Note.—Any barren surfaces above a cut slope shall be planted with selected varieties of light but deep rooted bushes, shrubs and grass to check soil erosion and improve the stability of the slope, in pursuance of any requisition or direction made or given by the Board of Councillors.