Part XProvisions for Salt Lake Township within Bidhannagar Municipal Area and Nabadiganta Industrial Township
93 Special provision.—
(1) Notwithstanding anything contained elsewhere in these rules, the provisions of this part shall apply only to the Salt Lake Township within Bidhannagar Municipal area and Nabadiganta Industrial Township and shall be construed to be in modification of, or to be supplementing, the other provisions of these rules in their application to the said Township.
(2) The provisions regarding construction of any building in any plot measuring 1.5 k within green verge, and plot measuring 2k or 3k plot within park, allotted for Community Hall, Ward Committee office building or such other building, shall be as may be required by the Bidhannagar Municipality or Nabadiganta Industrial Township Authority, as the case may be:
Provided that the provision for approval of building sites to construct or reconstruct building under rule 4 of these rules, shall not apply to the Salt Lake Township.
94 Administration.—
(1) The provisions of this part of these rules shall be enforced by the Bidhannagar Municipality or Nabadiganta Industrial Township Authority, as the case may be.
(2) The Bidhannagar Municipality or the Nabadiganta Industrial Township Authority may, at all reasonable hours normally between sunrise and sunset and after giving forty eight hours' previous notice, enter into or upon any building or premises for the purpose of ascertaining whether or not the provisions of the Part of these rules are being complied with.
95Definitions.—In this part,—
(1) “alley” means a secondary public thoroughfare which affords a means of access to the abutting property;
(2) “Anita” or “Mumty (Stair Cover)” means a cabin, that is, the structure with a covering roof over a staircase and its landing built to enclose only the stairs for the purpose of providing protection from weather and not used for human habitation;
(3) “apartment house” means a building arranged, intended or designed to be occupied by three or more families, independent of each other;
(4) “approved” means approved by the Bidhannagar Municipal Authority or Nabadiganta Industrial Township Authority, as the case may be;
(5) “Assembly Place” means a room, floor area, or building designed, intended or used to accommodate one hundred or more persons and used as a place for meetings, entertainments, instruction, worship, or any such other use;
(6) “Authority” means the Board of Councillors of the Bidhannagar Municipality, or the Nabadiganta Industrial Township Authority, as the case may be;
(7) “balcony” means a horizontal projection, including a hand rail, or balustrade to serve as passage or sitting outplace;
(8) “Barsati”, “Saiban” or “Penthouse” means covered space open at least on one side, constructed on a terraced roof used for shelter during rains;
(9) “height of building, or building height of “ means the vertical distance, measured in the case of flat roofs, from
the Road crown top level orl5 cm above of the Kerb Stone of the adjoining road, whichever is higher, to the highest point of the building and, in the case of pitched roofs, up to the point where the external surface of the outer wall intersects the finished surface of the sloping roof and, in the case of gables facing the road, the mid-point between the eaves level and the ridge.
[PART I
Explanation.—Architectural features serving no other function except that of decoration shall be excluded for the purpose of taking heights. If the building does not abut on a street, the height shall be measured above the average level of the ground around and contiguous to the building;
(10) “building line” means the line up to which the plinth of a building adjoining on a street or on an extension of a street or on a future street lawfully extended. It includes the lines prescribed, if any, in any scheme;
(11) “building line permissible” means a line parallel to the front line of the plot at a distance of the minimum width of the front yard, other lines being as fixed by the Authority having jurisdiction;
(12) “ceiling height” means the vertical distance between the floor and the ceiling or the bottom of the roof beam in case there is a beam;
(13) “cross wall” means an internal wall built into an external or party wall up to its roof level and of which it forms the limiting factor for the purpose of deciding its thickness;
(14) “damp-proof course” means a course consisting of some appropriate waterproofing materials provided to prevent penetration of dampness or moisture from any part of the structure to any other part at a height of not less than 15 cm. (or 6 inch) above the surface of the adjoining ground;
(15) “drain” includes a sewer, pipe, ditch, channel, and any other device for carrying off sewage, offensive matter, polluted water, sullage, waste water, rain water of sub-soil water, sealed sewage mains and special machinery or apparatus for raising, collecting, expelling or removing sewage or offensive matter to the sewage outfall;
(16) “drainage” means the act, process, method, or means of drainage, mode of discharge of water, system of drains;
(17) “exit” means a passage, channel or means of egress from any building, storey or floor area to a street or other open space of safety;
(18) “Filling Station” means an area of land including any structure or structures thereon, used or designed to be used for the storage and supply of gasoline or oil or other fuel for the propulsion of vehicles;
(19) “Fire-resisting material” means any of the following materials and the like:—
(a) masonry constructed with good, hard, sound and well-burnt bricks, fire bricks, stone or other hard and incombustible materials properly bonded and set in lime-surki, or lime-sand, or neat cement, or cementsand mortar;
(b) reinforced cement concrete, and other incombustible cement products;
(c) teak and other hard woods when used for beams and posts or in combination with iron, the timber and iron being protected by a plastering or coating with an incombustible and non-conducting external coating not less than 6 cm (or 2 inch) thick or, in the case of timber, not less than 2.5 cm. (or 1 inch) thick;
(d) slates, tiles, bricks, and terracotta when used for covering and corbelling;
(e) concrete, not less than 10 cm (or 4 inch) in thickness, composed of broken bricks, stone chippings or ballast and lime, cement when used for filling in between floor joists; and
(f) any other material approved by any Authority having jurisdiction;
(20) “footing” means the offset portions of a foundation to provide for a greater bearing area;
(21) “foundation” means the part of a structure which is below the lowermost floor and which provides support for the superstructure and which transmits loads of the superstructure to the bearing materials;
(22) “gallery” means the raised portion of a room, which remains open to the room.
Explanation.—The floor of the gallery may be either level or sloped. If the space below the gallery is enclosed or divided off from the room, the space so enclosed remains a ground floor room. If the side of the gallery which was open to the room is filled by a wall or partition, the gallery becomes a mezzanine floor;
(23) “garage private or private garage” means a building or outhouse designed or used for the storage of private owned motor vehicles;
(24) “garage public or private garage or public garage” means a building or portion thereof, other than private garage, operated for gain, designed or used for repairing, servicing, hiring, selling or storing motor driven or other vehicles;
(25) “ground floor” means the storey of a building to which there is an entrance from the outside of the adjacent ground or street;
(26) “ground level” means the average level of the centre line of the street or passage to which the plot abuts; or 15 cm above the abutting footpath level whichever is higher.
THE KOLKATA”GAZETTE, EXTRAORDINARY, FEBRUARY 14, 2007
47
(27) “habitable room” means a room occupied or designed for occupancy by one or more persons for study, living, sleeping, eating, kitchen, if it is used as a living room but not including bathrooms, water closet compartment, laundries, serving and storage panties, corridors, cellars, and attic and spaces that are not used frequently;
(28) “head room” or “headway” means the vertical distance between the floor and the ceiling.
Explanation.—Where a finished ceiling is not provided, the underside of the joists or beams of tie beams shall determine the upper point of measurement;
(29) “latrine connected” means a latrine connected to the Government sewer system;
(30) “load, dead or dead load” means the weight of all permanent stationary construction becoming a part of the structure;
(31) “load, Live or live load” means all loads except dead loads that may be imposed on a structure, and includes, Wind loads;
(32) “non-combustible”, in relation to materials, means a non-combustible material which neither burns nor gives off inflammable vapors in sufficient quantity to ignite at a pilot flame;
(33) “owner” means the person who receives the rent of the said premises or would be entitled to do so if the premises were let, and includes,—
(a) an agent or trustee who receives such rent on behalf of the owner;
(b) a receiver, executor or administrator or a manager appointed by any court of competent jurisdiction to have the charge of, to exercise the rights of, an owner of the said premises; or
(c) an agent or trustee who receives the rent of or is entrusted with or is concerned with any premises devoted to religious or charitable purposes;
(34) “partition” means a wall which supports no load other than its own weight;
(35) “pathway” includes an approach constructed with materials, such as bricks, murram, concrete, stone, asphalt, or the like;
(36) “plaster” means a pier forming part of a wall partially projecting therefrom and bounded thereto;
(37) “plot” includes a parcel or piece of land occupied or intended to be occupied by the main building together with its accessory buildings, used customarily or as incidental to it, and includes the open spaces required by these rules and having frontage upon a street or upon a private way that has officially been approved by the Authority;
(38) “plot corner” means a plot at the junctions of and fronting on two or more intersecting streets;
(39) “plot, depth of or depth of plot” means the mean horizontal distance between the front and rear plot boundaries;
(40) “plot, double frontage or double frontage plot” includes a plot having a frontage on two streets other than a corner plot;
(41) “plot, interior or tandem” includes a plot access to which is by a passage from a street, whether such passage forms part of the plot or not;
(42) “porch” means a covered surface supported on pillars or otherwise for the purpose of pedestrian or vehicular approach to a building;
(43) “Rain Water Pipe” includes a pipe or drain situated wholly above ground and used or constructed to be used for carrying water directly from roof, surface of elevated courtyard or other open surface;
(44) “registered plumber/plumbing firm” includes a qualified Plumber/Plumbing Firm who or which has been registered and enrolled in the panel of the Authority;
(45) “road” means any highway, street, lane, pathway, alley, stairway, passageway, carriageway, footway, square, place or bridge, whether a thoroughfare or not over which the public have a right of passage or access or had passed and had access uninterruptedly for a specified period, whether existing or proposed in any scheme, and includes all bunds, canals, ditches, storm-water drains, culverts, sidewalks, traffic islands, road side tree and hedges, retaining walls, fences, barriers and railings within the road lines;
(46) “road line” means the line defining the side limits of a road;
(47) “sanctioned plan” means the set of drawings and statements submitted under these rules in connection with a building and duly approved and sanctioned by the authority;
(48) “service road” means a road provided at the rear or side of a plot for service purpose;
(49) “sewage drain” means a closed drain used or constructed to be used for conveying solid or liquid waste matter, excremental or otherwise, to a sewer;
[P AR T I
(50) “shop” means a building or part of a building where articles of food of personal, domestic and household use and consumption are sold and goods of any kind are ordinarily retailed, but does not include a workshop;
(51) “slop sink” means a sink used or constructed to be used for receiving solid or liquid excremental matter;
(52) “smoke pipe” means a flue, approximately horizontal, of metal or other material in which smoke or the products of combustion are conducted from a furnace to a chimney;
(53) “storey topmost” means the uppermost storey in a building, whether constructed wholly or partly on the roof;
(54) “street”-has the same meaning as in clause (45);
(55) “street level or grade” means the officially established elevation of the centre line of the street upon which a plot fronts and if there is no officially established grade, the existing grade of the street at its mid-point;
(56) “structure” includes anything that is built or constructed, an edifice or building or any kind or any piece of work artificially built up or composed of parts joined together in some definite manner, and includes building;
(57) “to abut” means to abut on a road so that any portion of the building is on the road boundary;
(58) “to erect” means to construct a building for the first time or to reconstruct existing building after demolishing it according to some fresh or revised plan;
(59) “to make material alterations” means to make any modification in any existing building by way of addition or alteration, or any other change in the roof, window, door, compound, sanitary drainage system in any respect whatsoever, and includes—
(a) conversion of a building or any part thereof for human habitation as one dwelling house into more than one dwelling house and vice versa;
(b) conversion of a building or a part thereof not suitable for human habitation into a dwelling house or vice versa;
(c) conversion of a dwelling house or a part thereof into a shop, warehouse or factory or vice versa;
(d) conversion of a building used or intended to be used for one purpose, such as shop, warehouse, factory, etc. into one for another purpose.
Explanation.—Opening of a window and providing intercommunication doors shall not be considered as material alterations. Similarly, modifications in respect of gardening, white-washing, painting, retailing and other decorative works shall not be deemed to be material alterations.
(60) “to re-erect” means to construct for a second time or subsequent times a building or a part of a building after demolishing it, on the same plan as had been previously sanctioned;
(61) “wall, external or external wall” includes an outer wall or a vertical enclosure of any building being a party wall, even though adjoining a wall of another building, and includes a wall abutting on an interior open space of any building;
(62) “wall, party or part wall” includes a wall built on land belonging to two adjoining owners, the wall being the joint property of both owners.
Explanation.—If each of the two adjoining owners builds a dividing wall on their own property, they are not 'Party Walls' and no part of the footings of either wall shall project on to the land of the adjoining owner, except by legal agreement between the owners. Any such 'Party wall' or dividing wall shall be considered, for the purposes of these rules as being equivalent to an external wall, as far as thickness and height are concerned;
(63) “wall, part, compound” includes wall, used or constructed to be used for separation of adjoining lands of different owners and not being part of a building, but does not include a wall constructed on the land of one owner, the footings of which project over the land of another owner;
(64) “warehouse” means a building, the whole or a substantial part of, which is used or intended to be used for the storage of goods, whether for keeping or for sale or for any similar purpose, but does not include a store-room attached to and used for the proper functioning of a shop;
(65) “window” includes an opening to the outside, other than a door, which provides all or part of the required natural light and ventilation or both to an interior space;
(66) “water closet (WC)” means a privy with arrangement for flushing the pan with water, but does not include a bathroom;
(67) “yard” means an open space at ground level between a building and the adjoining boundary lines of the plot unoccupied and unobstructed, except by encroachments or structures specially permitted by these rules on the same plot with a building;
49
Explanation.—All yard measurements shall be the minimum distance between the front plot boundary, rear plot boundary and side plot boundary, as the case may be, and the nearest point of the building including enclosed or covered porches. Every part of every yard shall be accessible from every other part of the same yard;
(68) "yard, front or front yard" means a yard extending across the front of a plot between the side yard lines and being the minimum horizontal distance between the street line and the main building or any projection thereof other than steps, unenclosed balconies and unenclosed porches;
(69) "yard, rear or rear yard" means a yard extending across the rear of a plot between the side yard lines and being the minimum horizontal distance between the rear plot boundary and the rear of the building or any projection other than steps, unenclosed balconies or unenclosed porches;
(70) "yard, side or side yard" means a yard between the building and the side line of the plot and extending from the front line to the rear line of the plot and being the minimum horizontal distance between a side boundary line and the sides of the building or any other projection other than steps, unenclosed balconies or unenclosed porches.
Note:- The different categories of plots mentioned in these rules, shall be as specified below:
Category of plot
Areas
1.5 k
Any Plot having area of less than 2 cottahs;
2k
Any Plot having area of less than 3 cottahs;
3k
Any Plot having area of 3 cottahs or more but less than 4 cottahs;
4k
Any Plot having area of 4 cottahs or more but less than 5 cottahs;
5k
Any Plot having area of 5 cottahs or more but less than 6 cottahs;
6k
Any Plot having area of 6 cottahs or more but less than 7 cottahs;
7k
Any Plot having area of 7 cottahs or more but less than 8 cottahs;
8k
Any Plot having area of 8 cottahs or more but less than 9 cottahs;
9k
Any Plot having area of 9 cottahs or more but less than 10 cottahs;
10 k
Any Plot having area of 10 cottahs or more but less than 11 cottahs.
96Additional requirements for submission of building plan —
For submission of building plan under rule 11, in addition to the conditions laid down in these rules the following conditions are required to be fulfilled for the purpose of this chapter:—
(a) all plans shall be duly signed and certified by the owner in writing with inscription "Certified that I have gone through the West Bengal Municipal (Building) Rules, 2007, and also undertake to abide by those rules during and after the construction of the building"
Such plans shall also be signed and certified by the technical personnel engaged under rules 14-18 indicating their names, addresses, qualifications and enrollment numbers allotted by the authority with inscription "Certified that the plan has been designed and drawn up strictly according to the provisions of the West Bengal Municipal (Building) Rules, 2007".
(b) five copies of sewerage and water connection plans shall accompany the notice drawn to a scale of 1 m to 1 cm (or 8' to 1.0") and coloured as laid down in sub-rule (3) of rule 12 shall have to be submitted to the Authority. The size of the drawing sheet will be 30 x 22 cm.
97Notice for an alteration only —
When the notice is only for an alteration of the building, only such plans and statements as may be necessary shall accompany the notice:
Provided that a revised plan is to be submitted showing the changes proposed with the requisite fee as specified in rule 100.
Note.— (I) Every person who intends to demolish any building or part thereof shall give notice in writing to the Municipal Authority. The demolition work to be executed taking care of adjoining structures under the supervision of qualified or empanelled structural engineer.
(II) The building plan shall have to be obtained afresh.
[PART I
98 Repairs.—
No notice shall be deemed necessary for repairs in any existing building constructed in accordance with these rules.
104Cases of emergency.—
In cases of emergency which, in the opinion of the Authority, involves imminent danger to human life or health, the decision of the Authority shall be final. The Authority shall forthwith or with such notice as may be possible promptly cause such building, structure or portion thereof to be rendered safe or removed. For this purpose, the Authority may enter any time such structure or land on which it stands or abutting land or structure with such assistance and as may be deemed necessary. The Authority may also get the adjacent structure vacated and protect the public by an appropriate fence or such other means as may be necessary.
51
103Constructions not according to plan under sub-rule (2) of rule 30 or sub rule (1) of rule 34.—
Where, on inspection, it is found that any building or structure or any part thereof is being or has been erected in deviation of the sanctioned plan or in contravention of any of the provisions of the Act or the directions issued therein, the Chairman or his authorized representative may issue a notice, in writing, to the plot-holder to appear before him or his authorized representative within such period as would be mentioned in the Notice, but not less than 10 (ten) days from the date of issue of the letter, requiring the plot-holder or his authorized representative to explain the reasons for committing such deviation or contravention as would be mentioned in the notice.
101Part construction.—
(1) Part construction of a building according to any sanctioned plan may be permitted. Prior approval of part construction have to be taken from the Authority by submitting 2 copies of the plans (floor plan and front elevation of the part of the building proposed to be constructed). The Authority reserves the right to get the front elevation modified in case of such part construction.
(2) Part construction shall always start from the front and completed in full as per sanctioned plan for part construction.
(3) A partial occupancy certificate shall be issued for part construction under sub rule (4) of rule 34 and no occupancy certificate shall be issued till part construction is completed in full.
(4) In the case of multistoried flats of Housing Co-operative Societies a partial occupancy certificate may be issued for completion of 75% of the building. In this case the members of the concerned Housing Co-operative Society have to execute an indemnity bond with the condition that the member of the said Housing Co-operative Society shall complete the building on all respect within 180 days from the date of issue of the partial occupancy certificate and shall apply to the Authority for a full occupancy certificate.
102 Fees for sanction of revised plan or part plan.—
Fees for sanction of revised plan or for sanction of part plan shall be as follows:
(a) part plan-Rs 300.00 per floor per building;
(b) revised plan-Rs. 2.00 per sq. ft. of total floor area covered per building;
(c) renewal fee-Rs. 200.00 per floor per building;
106Access to Dwelling Units and Rooms.—
In every building containing more than one dwelling, access shall be provided to each dwelling unit without the necessity of passage through any other dwelling unit.
Note,—No room containing water closet shall be used for any purpose except as a lavatory and no such room open directly into any kitchen or cooking space by a door, window or other opening. Every room containing water closet shall have doors completely closing the entrance to it.
Obligatory front space, minimum side spaces and back spaces for various categories of residential buildings.—
(1) Obligatory front space, minimum side spaces and back spaces for various categories of residential buildings shall be as follows:—
Category of plot
Front (fixed) (in metre).
Narrower side (Min.) (in metre).
wide side (Min.) (in metre).
back (Min.) (in metre).
2k
1.00
0.90
2.50
2.00
3k
1.00
0.90
2.50
2.00
4k
1.00
0.90
2.50
4.00
5k
1.50
0.90
2.50
4.00
6k
2.00
1.00
3.00
6.00
7k
2.00
1.00
3.00
7.00
8k
2.00
1.20
3.00
7.00
9k
2.00
1.20
3.50
7.00
10 k
2.00
1.20
3.50
7.00
(2) In every building specified in sub-rule (2) of rule 93 there shall be a fixed front open space measuring 1.0 metre, minimum side open space of 1.22 meters and minimum back open space of 1.22 meters.
Explanation—For Block Areas the provisions of rule 153 shall apply.
(3) For the corner plots, the width of wider side space will be reduced to counterbalance, the difficulty of planning of the building due to rounding off the frontage but the clear gap with its adjacent building shall never be less than 2.5
[PART I
meters (8'-2"). The side spaces of the comer plots will also be suitably adjusted where provision for paved passage, open ground, playground, will allow for such adjustment. The maximum covered area and EA.R. will however remain the same as in other plots.
(4) A Plan showing the area that may be built up or covered can be seen by each plot holder in the office of the Authority sanctioning the building.
108 Open spaces with respect to covered area.—
Whenever the open spaces specified under rule 107 do not give the percentage of covered area in conformity with rule 109 the more restrictive of the two shall apply.
105Means of access.—
(1) For plots of more than 10 K where more than one house will be permitted, the organisation which erects building shall provide as means of access to such building a clear pathway not less than 3.6 m. in width for 3 storeys and 5 m (16 ft) in width beyond 3 storeys from a street to the entrance door of such building, and such pathway shall, so long as it is used as a means of access to that building be maintained free from any obstruction and shall not at any time cause or permit any portion of any building below a height of 5 m (16 ft) to overhang into such passage.
(2) No building shall be erected so as to deprive any other building of the means of access as provided in this rule.
(3) Every person who erects a building shall indicate upon any plan required to be furnished by him in accordance with these rules the whole area of such means of access by a distinguishing colour and description.
(4) Every person who erects a building shall not at any time erect or cause or permit to be erected or re-erected any building, which in any way encroaches upon or cause or permit to be diminished the area so set apart for this purpose.
(5) Every such means of access shall be drained and lighted to the satisfaction of the Authority. Manhole covers or other drainage, water or any other fittings laid in such means of access shall be flushed with the finished surface level so as not to obstruct safe travel over the same.
(6) A person who undertakes construction work on building shall not reduce the access.
(7) The means of access under these rules shall not be deemed to be suitable and sufficient until they have been approved by the Authority who shall have power to prescribe the width of the clear way which he shall communicate.
99Deviation during construction.—
If during construction of a building any departure or deviation from the sanctioned plan is intended to be made, sanction of the Authority shall be obtained before the change is made. The revised plan showing the deviation shall be submitted and the procedure laid down for the original plan therefor shall apply to all such amended plans. If on inspection during the construction stage, it is detected that deviation from the sanctioned plans have been made, the applications for the revised plan may not be entertained and the clearance certificate as mentioned in clause (a) of sub-rule (3) of rule 151 will not be issued in respect of the water and sewerage connections till rectification of the deviations.
100 Fees.—
(1) No building plan shall be deemed valid unless and until the person giving notice has paid the fees specified in sub-rule (2) to the Authority having jurisdiction and an attested copy of the receipt of such payment is attached with the building plan.
(2) Scale of fees for granting permission for building work under this part, shall be as follows:—
(a) Rs 3.50 per sq.ft. of total floor area covered in case of residential plots;
(b) Rs 10.00 per sq.ft. of total floor area covered in case of commercial plots and co-operative buildings.
110Projection.—
(1) Window chajja or cornice may project up to 0.5 m (l'-8") on all sides of the building.
(2) One cantilever verandah from first floor upward projecting upto property line may be allowed only on the frontage and side facing the roads (for corner plots only). This projection may be extended up to 0.5 m (1 '-8") on the wider and narrower side spaces also, provided that the permissible limit of FAR is not exceeded and that the width of such verandah shall not exceed 2.5 m (8'- 2"). Weather boards made either of concrete or pierced concrete or grill or glass or louvres or wood may be allowed to come down from second floor upwards up to the top level of windows in case of weather board from first floor, the clear gap between the bottom of weather board and plinth level shall be at least 8'-0". Only grills will be permitted to connect the above weather boards to the verandah railings on each of the floors and no window or solid wall shall be allowed. Verandah railings may be taken up to a maximum height of 1.25 m (4'-l"), provided that the solid part of it, if so constructed is limited to a height of 1 m (3'-4"):
Provided that in any co-operative building on any plot of 5 K or above, a cantilever verandah from ground floor and upwards projecting upto the property line may be allowed on frontage and side facing roads (for corner plot only) but under no circumstances shall any verandah projection be less than 2.4 m in clear height from ground level and that permissible limit of F.A.R. is not exceeded.
(3) The cantilever verandah on the first floor and above may be constructed within the open space after keeping open the space compulsorily required to be kept open as per rule 107, provided the permissible limit of F.A.R. is not exceeded.
(4) Weather Board may be taken down from the projected cantilever balcony at the front open space from the 1st floor level up to 8' height (2.43 m) from the plinth level.
53
(5) Projections for shelves not exceeding 0.25 m (10") beyond the outer surface of external walls may be allowed within the minimum wider, narrow and back open spaces for the purpose of making wall cupboards or alcove, provided the thickness of the wall for such projections is minimum 10" brick work or 3" thick reinforced concrete.
(6) Under no circumstances shall any verandah projection be less than 8' in clear height from the plinth level.
Floor Area Ratio (F.A.R.).—
(1) Permissible floor area ratio shall be as follows:—
Area of Plot
Floor Area Ratio
2K
1.25
3K
1.25
4K
1.75
5K
1.75
6K
2.10
7K
2.10
8K
2.25
9K
2.25
10K
3.20
Permissible for institutional, industrial and Commercial Buildings
2.75
Note.—For IT and ITES Buildings, FAR of 5.9 shall be permitted. However, in such building minimum 80% of the built up space shall have to be utilized for IT or ITES activities and condition stipulated by the State Government or ULB has to be adhered to.
Exemptions in calculation of FAR should be as per provisions laid down in Rule 53 (b). Any plot
specified in sub-rule (2) of rule 93, Floor Area Ratio shall be 1.35.
Explanation.—Floor area ratio, for the purpose of this rule, is the ratio of the total area of all the floors including the areas of walls, passages, staircase blocks, sanitary blocks, etc. of a building and accessory buildings to the gross area of plot.
Maximum number of floor.—
(1) Maximum number of floors to be built up shall be as follows:—
Area of Plot
Maximum no. of Floors allowed
2K
G Plus 1
3K
G Plus 1
4K
G Plus 2
5K
G Plus 2
6K
G Plus 3
7K
G Plus 3
8K
G Plus 4
9K
G Plus 4
10K
G Plus 7
Any plot specified in sub-
G Plus 1
rule (2) of rule 93.
G means Ground floor
[P AR T I
(2) So far as the restrictions to the number of storeys to be permitted in the buildings are concerned, the parking floor in the main building at ground level up to 2.25 m in height from garage floor level to the beam soffit will not be considered as floor, and will not be taken into consideration for the purpose of calculation of F. A.R.
(3) One mumti or a stair cover above the permissible number of storeys will be allowed in each of the buildings and this will not be covered by the rule of floor area ratio. The overall height of stair cover shall not exceed 2.85 m.
(4) The overall height of all tall buildings including the Mast should not exceed the approval accorded by the Airport Authority of India.
Note.—parking space at ground level shall be provided in all buildings including co-operative buildings, on any plot of 4 cottah or above, the maximum clear floor height of such parking space shall be 2.25 m. The height shall be measured from the ground level to the beam soffit level of ground floor slab (the ground floor) being the floor just above the parking space. Such parking space shall not be taken into account to calculate the permissible floor area ratio.
115Plinth regulation.—
(1) In the main building, no plinth or any part of such building or outer house shall be more than 0.9 m (3'-0") and less than 0.5 m (l'-8") above the ground level, the reference ground level being taken as 15 cm above the abutting footpath level or road crown level whichever is higher, vide clause (9) of rule 95.
55
(2) The minimum plinth height in respect of bathroom and water closet only may be reduced, provided the required slope for drainage up to the manhole is available. For this purpose, the minimum plinth height has been fixed as 30.48 cm (i.e. l'-0") only. In no case the rules of minimum height and size of the room would be relaxed.
(3) The minimum floor level of the garage shall be 15 cm above ground level.
(4) Every interior courtyard shall be raised at least 30 cm above the footpath of the abutting street, and shall be satisfactorily drained.
118Lighting and Ventilation of rooms.—
(1) (a) Every habitable room shall have, for the admission of light and air, one or more fixture, such as windows, fan, lights, opening directly to the external air or into an open verandah, and of an aggregate area, inclusive of frames, of not less than l/10th of floor areas.
Note (1): If a window is partly fixed and partly openable, only the latter area will be counted for the above purpose.
Note (2): No portion of a room shall be assumed to be lighted, if it is more than 7.5 m (25 ft) away from the door or window which is taken for calculation as ventilating that portion.
(b) Cross ventilation by means of windows shall be effected in at least one living room of a tenement either by means of windows in opposite walls, or if this is not possible or advisable, then, at least in the adjoining walls.
(2) In the case of mechanized light and ventilation, the standards shall be such as to give the same intensity of ventilation as is provided in sub-rules (1) and (3) and subject to the approval of the Authority, provided alternative arrangements to ventilating and lighting the room according to the standards laid down in sub-rules (1) and (3) have also been made.
(3) Bathrooms and water closets shall be provided with natural light and permanent ventilation by one of the following means:—
(a) windows having an area of not less than 10 per cent of the floor area and located in an exterior wall facing
[PART I
a street alley yard or an airshaft whose dimension in the direction perpendicular to the window is not less than 1/3 of the height of the building on which the window is located subject to a maximum and a minimum limit of 6 m (20 ft) and 1 m (3 ft) respectively;
(b) skylights, the construction of which shall provide light and ventilation as required in clause (a);
(c) ventilation ducts, provided such ducts have 1.30 cm2 of area for each m2 (2 in2 of area for each ft2) of floor area with a minimum total area of 330 m2 (48 in2) and a least dimension of 9 cm (3'/2 in). The vent register or grills to the duct shall be located in or next to the ceiling or the ventilated space. A separate duct from each space or room shall run to and above the roof and shall be provided with a lowered vent stack:
Provided, however, that when an exhaust fan is used, the duct opening may be located in an outer wall.
(4) Stores Box Rooms and the like shall have at least half of the ventilation required for living rooms. Where such ventilation by apertures in walls is not possible or advisable, at least there shall be ventilation by means of a flue or chimney.
(5) Laundry and recreation rooms located above the basement shall be lighted by windows located in exterior walls having openings of not less than 10 per cent of the floor area.
(6) Every kitchen shall be ventilated according to the standards prescribed for habitable rooms near the ceiling as far as possible. Each kitchen shall be furnished with smokeless chullas subject to the following conditions:—
(i) smoke shall not come out during the time of firing and cooking;
(ii) each kitchen shall be provided with a separate chimney;
(iii) chimneys provided for smokeless chullas shall be made of suitable diameter;
(iv) suitable provision shall be made at the bottom of chimney for clearing.
(7) Every staircase shall be lighted and ventilated from an open air space of depth (measured horizontally) not less than,—
(i) 3 m (10 ft) in case of ground and one upper floor structure; (ii)
4 m (15 ft) in case of ground and two upper floor structures; (iii) 6
m (20 ft) in case of further higher structures:
Provided that the lighting area shall be not less than 1 m (10 sq. ft) per floor.
Note.—Every staircase shall be ventilated properly.
119Other requirements.—
(1) Every bathroom or water closet shall—
(i) be so situated that at least one of its walls shall be open to external air;
(ii) not preferably be directly over or under any room other than another latrine, garage, washing place, bath or terrace, unless it has a water-tight floor;
(iii) have the platform or seat either plastered with cement or made of some water-tight non-absorbent material;
(iv) be enclosed by walls or partitions of bricks. Surface of every such wall or partition shall be furnished with a smooth, impervious material, such as cement plaster 1.3 cm thick or glazed tiles or polished marble or any suitable materials to a height of not less than 1 m (3 ft) above the floor of such a room;
(v) be provided with an impervious floor covering sloping towards the drain; and (vi) have a floor level of such a height as to ensure suitable grade towards the sewage drain.
(2) Every room to be used as kitchen shall have—
(i) a floor area as provided under rule 117(2);
(ii) either a suitable flue for the escape of heated air or an approved form of smokeless chulla;
(iii) a height as provided in rule 116(3);
(iv) unless separately provided in a pantry, means for the washing up of kitchen utensils which shall lead directly or through a sink to a grated and trapped connection to the waste pipe.
120 Drainage of roofs.—
The roof of a building shall be so constructed or framed as to permit effectual drainage of the rain water therefrom by means of a sufficiency of rain-water pipes of adequate size so arranged, joined and fixed as to ensure that the rainwater is carried away from the building without causing dampness in any part of the walls or foundation of the building or those of an adjacent building.
57
121Water tanks and cisterns.—
(1) A tank or a cistern constructed with a building and intended for storage of water for human consumption or domestic purpose shall comply with the following requirements:—
(i) the Authority shall supply water at the ground level only and any arrangement for lifting the water by means of pumps to a suitable height and distribution of water in the building shall have to be done as per approval of the Authority. For this purpose, construction of house tanks shall be made at suitable levels in every household operated by properly checked ball valves;
(ii) no household up tap connections should be taken direct but through house tank.
(2) The tank of high level for distribution of water in the premises shall be constructed of metal reinforced cement concrete or lined with metal or metal sheets and be of such a design, weight and quality as has been approved by the Authority. The tank or cistern at ground level or below ground level for receiving supply from the water mains is to be constructed in the wider side and/or the back space (leaving) 1.52 m for the back boundary line or within the built up area or partly between the side space, back space and the built up area. The depth of foundation of the tank shall not exceed 0.75 m (2'-6") from the ground level, the ground level being taken as 8 cm (0'-3") above the abutting footpath. This tank shall be water tight, properly covered over and shall be constructed of reinforced concrete or brick work in cement mortar or designed according to a manner approved by the Authority and shall be rendered inside with cement mortar.
(3) The tank shall be provided with a draw off pipe, tap or other apparatus the invert of which shall be not more than 5 cm (2 inch) high from the bottom of the tank.
(4) The tank shall be provided with an overflow pipe which shall—
(a) be so located and fitted as to prevent entry of animals and insects;
(b) not be connected to a drain or sewer;
(c) have an open end to permit the overflow pipe to serve also as a warning pipe;
(d) have to be so located that it is open for inspection by any person authorized by the Authority:
Provided that, in the case of any building specified in sub-rule (2) of rule 93, the tank or cistern at ground level or below ground level is to be constructed in any space excepting fixed from open space.
113Maximum number of flat per storey.—
(1) Maximum number of flats per storey shall be as follows:—
2K
One Flat per Storey
3K
One Flat per Storey
4K
One Flat per Storey
5K
Two Flats per Storey
6K
Two Flat per Storey
7K
Two Flat per Storey
8K
Two Flat per Storey
9K
Two Flat per Storey
10K
Three Flats per Storey
In the case of any building specified in sub-rule (2) of rule 93
One Flat per Storey
(2) A certificate shall be furnished by the owner of the plot measuring 2 cottahs to 5 cottahs on the body of each plan of building furnished for sanction in the following form:—
"Certified that I shall not on later date make any addition or alteration to this plan so as to convert it for use or allow it to be used for two separate flats per floor/per storey."
(3) Notwithstanding anything containing in the preceding sub-rules, one additional bath-cum-W.C. for attendant may be allowed in each building, over and above the permissible numbers having minimum size as specified in rule 117. The said bath-cum- W.C. will be the integral part of the whole building:
Provided that one room for watchman with attached bath-cum- W.C. may be provided at car parking space of cooperative building, the floor area of which shall not be counted in floor area ratio. The floor area of such room shall not be more than 10.00 sq. m. and that of the bath-cum-W.C. shall not be more than 3.00 sq. m.:
Provided further that one room for watchman with attached bath-cum- W.C. may be allowed at the roof level of all existing buildings not exceeding the height of mumti roof, subject to the condition that the wider side space of all such buildings will be made free from any sort of construction, the floor area of which shall not be counted in floor area ratio. The floor area of such room shall not be more than 10.00 sq. m. and that of the bath-cum-W.C. shall not be more than 3.00 sq. m.
114 Basement and floors underground rooms.—
Except with the written permission of the Authority, no person shall construct any basement floor, vault or underground rooms either under or as a part of building or otherwise and this will be considered as a floor and floor area ratio as specified in rules 111 and 112.
116Height regulation.—
(1) The height of all rooms for human habitation shall not be less than 2.75 m (9'-0") measured from the surface of the floor to the lowest point of ceiling and beam.
(2) The height of Bathroom, water closet and stores, measured from the floor to the lowest point of ceiling or beam, shall not be less than 2.29 m (7'-6").
(3) The height of the kitchen, measured from the floor to the lowest point of ceiling, shall not be less then 2.75 m (9 ft):
Provided that the maximum height of each floor of any residential building shall be restricted to 3.6 m unless and otherwise specified in the guidelines of National Building code.
(4) The ledge or tand shall have a minimum head room of 2.1 m (7 ft).
(5) The loft shall have a minimum head room of 2.29 m (7'-6").
109Covered area.—
(1) The maximum covered area of residential buildings shall be governed by the following:
Category of Plot
Maximum permissible covered area
(i)
2,3 and 4 cottahs
55% of the site area
(ii)
6 and 7 cottahs
50% of the site area
(iii)
8,9 and 10 cottahs
45% of the site area
(iv)
Building specified in sub rule (2) of rule 93
60% of the site area
(v)
IT, ITES & other permissible Industrial & Commercial Sector Buildings
40% of the site area
Explanation.—For Block Areas, the provisions of rule 153 shall apply.
(2) In case of existing buildings only in the wider side space (or in the back space in the case of corner plots of 4 K and above), only one motor garage up to 5.00 m (overall) in length, 15 Sq. Metre in area and 2.25 m in height from Ground Level will be allowed in the case of 2 K or 3 K corner plots, a garage may be allowed in any place outside the covered area without covering any part of the narrower side within the limits regulating the height and width). The minimum clear width and the area of this garage will be 2.25 m and 9.60 sq. metre respectively. This garage or such portions of it as would be constructed within the minimum width of the wider space will be over and above the covered area specified above and will not also be taken into consideration while calculating F. A.R. No accesses to the roof of this garage will be allowed. Garage in the wider space cannot cover the minimum width of the back space as specified in rule 107.
117Size of room.—
(1) No habitable room shall have a floor area of 9.50 sq. m. except in the case of hostels attached to recognised institutions and in Industrial or Low Income Housing Schemes where the size of habitable rooms or the residence of a single person shall be not less than 7.45 sq. m.
(2) A kitchen shall have a floor area of not less than 4.20 sq meters and shall not be less than 1.52 m in width in case of plots having an area up to 167.2 sq m and shall have a floor area of not less than 5.57 sq meters and shall not be less than 1.83 m in width in case of plots having an area of more than 167.2 sq m. In case of Industrial or Low Income Group Housing Scheme, the minimum floor area of kitchen shall be 3.4 sq m. A kitchen, which is intended for use as a dining room also, shall have floor area of not less than 9.29 sq m with a minimum width of 2.5 m.
(3) Every bathroom shall have a floor area of not less than 1.80 sq m for which the smallest side shall not be less than 1.22 M and if a water closet room is combined with the bathrom, the floor area shall not be less than 2.80 sq m and the smallest side shall not be less than 1.22 m. Every water closet shall have a floor area of not less than 1.10 sq M for which the smallest side shall not be less than 0.9 m. The minimum floor area of bathroom and water closet in the case of Industrial or Low Income Group Housing Scheme shall be 1.53 sq m and 1.10 sq m respectively.
(4) A ledge or tand in a habitable roof shall not cover more than 25% of the area of the floor on which it is constructed and shall not interfere with the ventilation of the room under any circumstances.
125Flushing of connected privies and urinals.—
(1) Every connected privy shall be provided with suitable water-cistern, so arranged as—
(a) to discharge direct into the pan of the privy not less than thirteen litres of water each time the cistern is used, and
(b) to prevent water being drawn from the cistern for any other purposes.
(2) All waste pipes and overflow pipe attached to such cistern shall terminate in the open air and a cut off from all direct communication with any drain.
(3) Every connected urinal shall be provided with adequate flushing arrangements to the satisfaction of the Authority.
(4) For the purpose of supplying water to the flushing cistern of a connected privy or connected urinal, a reserve tank of such capacity as may be specified by the Authority shall be provided at a height sufficient to supply the cistern with water:
Provided that the minimum size of a privy shall be 1.10 m2 (12 sq ft). The wall of the privy shall be lined internally with smooth impervious non-absorbent coating of rest Portland Cement and shall be of not less than 1.27 cm thickness or of the glazed tiles or polished marble to a height of not less than 91 cm:
Provided further that every connected privy and connected urinals shall be provided with a pan of such form and dimensions as may be approved by the Authority:
Provided also that every connected privy and connected urinal shall be provided with an air-tight water-trap immediately below the pan.
122Pipes and Fittings.—
All pipes including all bends, junctions, tees, and elbows and all fittings used in connection with, or forming part of, the sanitary installation of a building or for the supply and distribution of water to and in a building shall be made of such material and be of such manner as may be approved by the Authority.
Sinks.—
(1) A sink shall be so located that at least one of its sides will be against an external wall or in a window recess or in a position to ensure suitable connection.
(2) (a) Sinks shall be constructed of glazed stoneware, enameled fireclay or other equally suitable material;
(b) they shall be of such shape as will facilitate their maintenance in a state of cleanliness;
(c) no wood work shall be used for covering any such sink;
(d) the bottom of the sink shall slope towards the outlet.
(3) (a) A pipe shall be joined to the sink by a bell mouth at the bottom of the sink having its internal diameter about one inch larger at the sink than at the other ends;
(b) the sink outlet shall be fitted with a brass grating and a plug;
(c) the sink waste pipe shall have an internal diameter of not less than 5 cm (2 inch) and shall be preferably provided with a trap of drawn lead or other equally suitable material fitted with a brass cleaning screw at the bend.
Privy.—
No other privy except connected privy discharging into the underground sewerage system shall be constructed in any building. The floor of every privy shall be made of cement concrete Patent stone or vitrified or well-pointed earthen tiles or mosaic and shall be in every part at a height' of not less than thirty centimeters above the level of the surface of the ground adjoining the privy. The floor of every connected privy in which the opening of the pan is placed on the level of the floor shall have a fall or inclination towards the pan of at least one in twenty four. Every connected privy situated in a building shall have opening of not less than 0.55 sq meters in area in anyone of the walls of the privy as near the top of the wall as may be practicable and communicating directly with the open air.
[Part I
126Syphon-trap and Anti-syphonage Pipe.—
(1) Every connected privy and connected urinal shall be provided with a syphon trap which shall be proof against syphonage.
(2) In all cases where a connecter privy or connected urinal is more than one storey high, an anti-syphonage pipe having an internal diameter of not less than fifty millimeters shall be provided, and such pipe shall be carried independently to a height of at least sixty centimeters above the roof of the privy or urinal or the roof of the building in which such privy or urinal is situated.
(3) No 'container' or other similar fittings shall be placed under the pan of a connected privy or connected urinal and no trap of the kind known as a 'D trap' shall be used with any such privy or urinal.