- Regulation for more than one building in one plot, existing buildings and the buildings under Government approved schemes.—
(1) (a) Every building on a plot containing more than one building which does not abut on means of access shall abut an internal road connecting the means of access of the plot. The floor area ratio shall be calculated on the basis of the width of means of access on which the plot abuts
(b) The minimum width of such internal roads shall be 3.50 meters. Where internal road of 3.50 meters in width is not possible to be provided due to an existing building constructed prior to the enforcement of these rules, a building of not more than 7.0 meters in height may be allowed, provided that the width of the internal road shall not be less than 1.20 meters.
(c) The maximum permissible height of any building on a plot shall be determined by the width of the means of access on which the plot abuts according to the table given in sub-rule (3) of rule 49.
(d) The minimum width and the maximum length of all such internal roads shall be as prescribed in the table below:—
Table Width and Length of Internal Roads
| Width of means of access. | Maximum length of the means of access. | |
| 3.50 meters and above but not more than 7.00 meters | 25.00 | 75.00 |
| above 7.00 meters but not more than 10.00 meters | 50.00 | 150.00 |
| Above 10.00 meters | No restriction | No restriction: |
Provided that every internal road as required under this rule shall be kept free from any projection thereon and shall be kept open to the sky.
Note.—No chajja or cornice or weather shed more than 500 mm. shall overhang or project thereon.
(e) In case the buildings within a plot are not of the same occupancy, an individual building of any particular occupancy shall comply with the rules governing such occupancy except the provisions regarding ground coverage which shall be in accordance with sub rule (2) of this rule.
(2) Ground coverage for plots measuring 5000 sq. meters or more in area, the maximum permissible ground coverage shall be 45% for residential buildings or educational buildings, and 35% for buildings of other use groups or for buildings with mixed occupancies:
Provided that the provisions of rule 46 shall be applicable to plots measuring less than 5,000 sq. meters.
(3) Open space for building shall be as laid down below:—
(a) every building shall have minimum external open space prescribed in rule 50, provided that on these open spaces internal roads may be constructed;
(b) for plots measuring more than 5000 sq. m. in area, provision of 8% of the total area of the plot is to be kept as public open space. The width of each such open space shall not be less than 10.00 meters and each such open space shall abut a street having a width of not less than 7.00 meters. The minimum area of each of such open space in one parcel shall be 400 sq. m. This open space shall be in addition to the land required for providing the means of access to the individual plots as prescribed in rule 45. No objection certificate from the Director of West Bengal Fire services and West Bengal Pollution Control Board in respect of the proposed construction is to be submitted along with the application for building permit;
(c) for plots measuring more than 25000 sq. m. in area provision of 7% of the total area of the plot shall be reserved for use for facilities like School, Health Centres, Market, Police Outpost with booth, Post Office, Power Sub-station, Transport Terminal, Water Treatment Plant, Sewerage Treatment Plant as well as the provisions for Green cover and free gift of land for Economically Weaker Section housing and the like, such land shall abut a street having a width of not less than 10 meters in addition to the land necessary for means
[PART I
of access and for open spaces sanctioned in clause (b) of this sub-rule. No objection certificate from the Director of West Bengal Fire services and West Bengal Pollution Control Board in respect of the proposed construction is to be submitted alongwith the application for building permit.
(4) The parking provisions shall be the same as stipulated in rule 52.
55 Provisions regarding existing buildings.—
(1) The provisions of these rules shall apply only in the case of an existing building.
Note.—Existing building, for this purpose shall mean any building which was erected before the date of coming into force of these rules in accordance with a building plan sanctioned by an authority competent to sanction such building plan under the Bengal Municipal Act, 1932 (Ben. Act XV of 1932) or any other law for the time being in force.
(2) In the case of existing building,—
(a) excepting storage buildings, where the open spaces required have not been provided, an addition in the number of stories, if otherwise permissible, may be allowed with a set back, provided such building continues with the same occupancy:
Provided that no formal set back may be necessary up to a height of eight meters for adding only one floor over an existing single storied residential building;
(b) the extent of the set back from the property boundary shall be such as to make the addition to the building conform to the provisions of rules 46 and 50;
(c) if any car parking space is required to be provided under these rules and no such car parking space can be provided, the covered area allowable under the provisions of these rules shall be reduced by the area required for such car parking space which cannot be provided in the said building.
Explanation.—For the purpose of calculation, the area required for one car parking space shall be taken as 20.00 sq. meters;
(d) the height of the building shall conform to the rules as indicated in rule 49 and in no case after addition the height shall exceed 14.50 meters;
(e) the addition to an existing building with residential occupancy shall not exceed 200.00 sq. meters in covered area;
(f) the addition to an existing building with educational occupancy shall not exceed the total covered area of the existing building;
(g) the addition to an existing building with other occupancies including mixed use building but excepting storage building shall not exceed 100.00 sq. meters in covered areas;
(h) in case of partition of existing building common walls may be allowed as the partition line.
56 Provisions for buildings constructed under Government approved schemes.—
(1) Notwithstanding anything contained elsewhere in these rules, the provisions of this part shall apply in respect of matters provided therein, in the case of buildings constructed by Governments, or any of the statutory bodies under any Government approved scheme, for residential use of persons belonging to low income group or of industrial workers.
(2) The minimum size of a plot shall not be less than 30 square meters and the maximum size of the plot shall not be more than 65 square meters.
(3) The following provisions shall be complied with for the construction of building under sub-rule (1):—
(a) no building shall be constructed on a plot if the width of the means of access to the site is less than 1.2 meters;
(b) no building exceeding 8.0 meters in height shall be allowed on a plot if the width of the means of access to the site is less than 3.5 meters;
(c) the maximum permissible ground coverage shall be 75% of the area of the plot;
(d) the maximum height of the building shall be 10 meters;
(e) the minimum front open space for a building shall be 0.8 metre;
(f) the minimum rear open space for a building shall be 1.0 metre;
(g) the buildings may be of the row housing type with common wall and the maximum length of the buildings in a row shall be 50 meters. After every 50 meters of length of the building in a row, there shall be an open space of not less than 2,5 meters in width for the entire depth of the building:
Provided that such open space shall not be necessary if there is a street or passage at such location, the minimum width of which is 2.5 meters;
(h) no parking space within the plot shall be necessary.
37