- Rules for means of access in areas other than the Municipalities in hill areas.—
(1) (a) Every plot shall abut a means of access which may be a public street or private street or passage.
(b) The relationship between the width of the means of access and the maximum permissible height of building shall be as indicated in rule 49.
(2) The minimum width of means of access in respect of a new building shall be as follows:—
(a) no new building shall be allowed on a plot unless the plot abuts a street which is not less than 10.00 meters in width at any part, or there is access to the plot from any such street by a passage which is not less than 10.00 meters in width at any part:
Provided that:—
(i) in case of a residential building with other occupancies, if any, of less than 10% of the total floor area of the building, the width of such street or passage shall not be less than 2.40 meters at any part,
(ii) in case of a residential building with educational occupancy of 10% or more of the total floor area of the building, the width of such street or passage shall not be less than 7.00 meters at any part,
(iii) in case of an educational building with residential occupancy the width of such street or passage shall not be less than 7.00 meters at any part,
(iv) in case of an educational building with other occupancy or occupancies not being residential of less than 10% of the total covered area of the building the width of such street or passage shall not be less than 7.00 meters at any part;
(b) notwithstanding anything contained in clause (a), residential buildings up to a maximum height of 7.00 meters may be allowed on a plot abutting a means of access not less than 1.20 meters, provided such means of access is in long existence and is recorded in the settlement records and/or Municipal records accordingly.
(3) Any building which in full or part is put to assembly occupancy for the purpose of theatre, motion picture house, city hall, skating rink, auditorium, exhibition hall or for similar other purposes shall not be allowed on a plot located within 50 meters of junction of two streets, the width of each of which is 15.00 meters or more.
(4) Notwithstanding the provisions of these rules, in the case of any building which is intended to be erected at the corners of two streets, the Municipal Authority may, in accordance with the provisions of the Act, place special conditions concerning exit or entry from any street.
(5) Requirements of a private passage:—
Every means of access appertaining to a site shall be drained and lighted to the satisfaction of the Municipal Authority and manhole covers or other drainage, water supply or other fittings laid in such means of access shall be flushed with the finished surface so as not to obstruct safe travel over the same.
25
46 Ground coverage in respect of buildings in areas other than municipalities in hill areas.—
(1) (a) The maximum permissible ground coverage for building, when a plot contains a single building, shall depend on the plot size and the use of the building as given in the table below:
Table
Maximum permissible Ground Coverage
(Plot containing a single building)
| Type of building. | Maximum permissible ground coverage. |
|---|---|
| 1. Residential and educational: (a) Plot size up to 200 sq. meters (b) Plot size of above 500 sq. meters; 2. Other uses including mixed use | 65%50%40%. |
(b) for any other size of the plot, in between the plot size of 201 to 500 square meters, the percentage of coverage shall be calculated by direct interpolation.
(2) When a plot contains more than one building, the maximum permissible ground coverage for the building shall be as stipulated in rule 54.
(3) For mercantile buildings (retail) and assembly buildings on plots measuring 5000 sqm. or more, the additional ground coverage to the extent of 15% may be allowed for car parking and building services. The additional ground coverage of 15% will be exclusively utilized for car parking, ramps, staircase, lift for upper level car parking and for building services such as Air Conditioned plant room, generator room, fire fighting equipments, electrical equipments not exceeding 5% out of such 15% shall be used, subject to compliance of other relevant building rules.
47 Addition of new plot.—
When one or more plots of land are added to one or more premises by way of amalgamation or otherwise, in that event the existing buildings on any plot/plots, if any, shall stand as authorized in case those are constructed in accordance with the building rules of the material time when the building/buildings was/were sanctioned. Addition, alteration to the sanctioned building or addition of a new building or new block on newly added land/lands may be permitted as per these rules considering amalgamated land to be a new plot.
48 Linking of two blocks.—
Notwithstanding anything contained in rule 51 if there are two adjacent plots or adjacent buildings of the same owner, gangways between two buildings may be permitted at any level subject to the condition that it does not obstruct movement of vehicles or fire vehicles. The minimum width of the gangway shall not be less than that of stairway and not exceeding 3.00 meters at any place.
49 Permissible height of buildings in areas other than municipalities in hill areas.—
(1) Height of a building shall be the vertical distance measured from the average level of the centre line of the adjoining street or passage on which the plot abuts to the highest point of the building, whether with flat roof or sloped roof.
(2) (a) The following appurtenant structure shall not be included in the height of the building:—
(i) stair cover not exceeding 2.40 meters in height;
(ii) lift machine rooms as per the latest edition of the National Building Code;
(iii) roof tanks and their supports, the height of support not exceeding 1.00 metre;
(iv) chimneys;
(v) parapet walls not exceeding 1.50 meters in height;
(vi) ventilating, air conditioning and other service equipments;
(vii) height above mid-point between eaves level and ridge level;
[PART I
(viii) toilet at roof level upto a height of 3.0 mtrs. subject to maximum floor area of 3.00 sq.m.;
(ix) garden cover with permeable material not exceeding 3.00 mtrs. in height;
(x) equipments for communication such as Microwave Antenna, Towers, Dish Antenna as well as room for installing the said equipments or their support equipments subject to a maximum area of 20 sq.m. and further subject to permission of the same from Municipal Authority.
(b) The aggregate area of the structures mentioned in clause (a) shall not exceed one-third of the area of the roof upon which these are erected;
(3) The maximum permissible height of buildings on a plot shall be as given in the table below:—
TABLE
| Width of means of access (in meters). | Maximum permissible height (in meters). |
|---|---|
| (a) 2.40 to 3.50 (b) above 3.50 to 7.00 (c) above 7.00 to 10.00 (d) above 10.00 to 15.00 (e) above 15.00 to 20.00 (f) above 20.00 to 24.00 (g) above 24.00 | 8.0011.0014.5018.0024.0036.001.5 x (width of the means of access + required width of front open space). |
Note : (I) There will be no restriction in height of buildings for plots abutting means of access above 10 mtrs in width subject to free gifting of strip of land as per prescribed street alignment. However, this increase in height as mentioned above shall be permissible provided the minimum area of the plot is 2500 sqm. and minimum frontage of the plot abutting the main road is 30.0 Meters.
(II) In case of such additional height by free gifting the strip of land as mentioned hereinabove, the applicant will get FAR of original road width only. However, the applicant will be given benefit of FAR and ground coverage of the portion gifted to the Municipality.