The norms, other than the ones mentioned in this chapter shall be in accordance with Harmonised Guidelines and Standards for Universal Accessibility in India, 2021. These shall include design elements, and standards to for an include universal design.
10.1 Provision/ facilities for Differently abled Persons
a) In all public buildings/places of public gathering, the level of the roads, access paths and parking areas shall be described in the plan, along with specification of the materials.
b) It should be ensured that during winter the ramps, canopies and sheds are kept dry and non-slippery.
c) The specified facilities in public buildings/sites for differently abled persons shall be as follows:
(i) Parking: For parking of vehicles of differently-abled people the following provisions shall be made: -
(a) surface parking for two car spaces shall be provided, near the entrance, for the differently abled persons, with maximum travel distance of 30 meters from building entrance,
(b) the parking bay shall be of minimum 3.6 meters in width and marked as reserved for wheelchair users.
(ii) Every building shall have at least one entrance accessible to the differently- abled and shall be approachable through a ramp in addition to the stepped entry made of non-slippery material with a minimum width of 1.5 meters in a maximum gradient of 1:12, length of ramp shall not exceed 9.0 meters having 0.8 meters high handrail on both sides of extending 0.3 meters beyond top and bottom levels of the ramp. The minimum gap between the wall and the handrail shall be 5 cm.
(iii) Stepped approach- For stepped approach, size of tread shall not be less than 0.3 meters and maximum riser shall be 0.15 meters with provision of 0.8 meters high handrail on both sides of the stepped approach similar to the ramped approach shall be made.
(a) Exit/ entrance door- Minimum clear opening of the entrance door shall be 0.9 meters and shall not be provided with a step that obstructs the passage of a wheelchair user.
(b) Entrance landing- Entrance landing shall be provided adjacent to the ramp, with the minimum dimension of 1.8 meters x 2.0 meters.
(iv) Corridor connecting the entrance/exit for the differently abled; the corridor
connecting the entrance/exit for differently abled leading directly outdoor to a place where information concerning the overall use of the specified building can be provided to visually impaired persons by a person:
(a) the minimum width of corridor shall not be less than 1.5 meters,
(b) in case there is a difference of level, slope-ways shall be provided with a slope of 1:12 with specified above handrails.
(v) Stair-ways- One of the stairways near the entrance/exit, for the use of differently abled, shall have the following provisions:
(a) the minimum width shall be 1.35 meters,
(b) height of the riser shall not be more than 0.15 meters and width of the tread 0.30-meter, maximum number of risers on a flight limited to maximum12,
(c) handrails shall be provided on both sides.
(vi) Lifts- Wherever lift is required as per NBC, provision of at least one lift shall be made for the wheelchair users, with the following cage dimensions, recommended for passenger lift of 13 persons capacity by the Bureau of Indian Standards:
(a) Clear internal depth 1.1. meters,
(b) Clear internal width 2.0 meters,
(c) Entrance door width 0.9 meter,
(d) a handrail not less that then 0.6 meter long and 1.0 meter above floor level shall be fixed adjacent to the control panel,
(e) the lift lobby shall measure 1.8 meters x 2.0 meters or more,
(f) the time of an automatically closing door shall be minimum 5 seconds and the closing speed shall not exceed 0.25 meter/ second,
(g) the interior of the cage shall be provided with a device that audibly indicates the floor. When the cage reaches on floor, it shall indicate that the door of the cage for entrance/ exit is either open or closed.
(vii) Toilets: One special water closet shall be provided with essential provision of wash basin inside toilet near the entrance having:
(a) minimum dimensions of 1.50 meters x 1.75 meters,
(b) minimum clear opening of the door of 0.90 meter and shall swing out,
(c) suitable arrangement of vertical/horizontal handrails with 50mm clearance from the wall.
(viii) Drinking Water: Suitable provision of drinking water shall be made for the differently abled persons near the special toilet provided for them.
(ix) Designing for Children: In the building meant for the predominant use of children, the height of the handrail and other fittings and fixtures, shall suit the requirements of children.