9.1 Rainwater Harvesting for Ground Water Recharge
Arrangement for roof top and ground surface rainwater harvesting within the plot shall be made by the plot owner plot measuring more than 70 square meters:
(i) Recharging of ground water shall be mandatory not only for residential buildings but for all types of buildings, including Group Housing Societies having a plot area more than 250 square meters,
(ii) The Ground Water Recharge shall be mandatory for open spaces like parks, parking, plazas, playgrounds, and other common areas. The harvesting and recharge structures should be constructed by the Authority by associating community-based organizations including Resident Welfare Associations, or by any other agencies or client themselves,
(iii) Where snow remains on the surface within a plot or in parks, open spaces, the water of melting snow should flow to the ground water recharge system.
Rainwater Harvesting System Measures
i. The collection, conveyance, and dispersal of rainwater for harvesting should only be of clear water to check contamination of ground water. This shall include ‘filtration and storage’ of surface run-off for limited range, and re-use of collected and filtered rainwater.
ii. The entry or pouring points of the rainwater shall be designed to remain covered.
iii. The arrangement of quick filtration of rainwater shall also be made in the rainwater harvesting well/ tube well so that rainwater does not choke the strata.
iv. The complete rainwater harvesting system shall be constructed within the available area of the plot.
v. The recharge well shall be located at a distance of not less than 10 meters away from any structure handling sewage or industrial wastewater (such as septic tank or effluent treatment plant etc.). This minimum distance of 10 meters shall not be applicable to manholes or sewer lines although it shall be ensured that they are leak proof.
vi. The detailed proposal of the system comprising collection, conveyance and dispersion of rainwater harvesting well/ tube well shall have to be shown on the building plan submitted for approval.
vii. An architect/engineer duly engaged for supervision and execution of the construction of the building shall submit the certificate stating that the rainwater harvesting system is functional at site and same conforms to the provisions of
these Bye-Laws. However, if the architect/ engineer found guilty of misrepresentation of the facts, penal proceedings shall be initiated along with debarring the concerned architect/engineer from practicing in the UT of Ladakh.
viii. The construction of the building as laid down in sub-clause (1) shall be the part of occupation certificate. Unless such construction is completed as per the approval, occupation certificate shall not be issued.
ix. The owner of every building shall ensure that the rainwater harvesting structure is maintained in good repair for storage of water of non-potable purposes and recharge of ground water at all time.
x. The above said provisions of Rainwater Harvesting shall be strictly implemented in the Local Areas, notified from time to time.
xi. Groundwater extraction needs to be regulated; water meters need to be installed for recording flow/quality of water extraction. District metered areas and connection to SCADA system needs to be incorporated for all connections
xii. Snowmelt run-off drains need to be away from pathways in order to prevent hazards due to freeze-thaw cycles.
xiii. Chapter-9 of Model Building Byelaws, 2016 need to be referred for incorporating further techniques and measures of Rainwater Harvesting.
xiv. Any further guidelines and rules released by Govt. of India/UT Acts, Laws, and Byelaws would be applicable as notified from time to time.
9.2 Compulsory tree Plantation to increase tree cover
i. To reduce cold desert effect in Ladakh, measures to increase the vegetal cover shall be enforced. Each household shall plant the minimum number of plants as prescribed in these Bye-Laws.
ii. To enhance fertility in the sand-shedding slopes, the biodegradable waste shall be deposited in layers under the sand cover to allow decomposition. The layers of waste shall be watered by the recycled treated water which will facilitate natural growth of vegetal cover in days to come.
iii. Such sand-shedding slopes where snow is received even in meager quantity, shall be terraced, or provided with check dams to store the snow and allow the water to percolate gradually, in the biodegradable waste layers.
iv. The kitchen waste, waste from food industry, fruit and vegetable markets, horticulture waste shall be carried to the sandy surface and deposited below the sand layers and sprinkled with the recycled treated water, or surface water/ground water, as the case may be.
9.3 Provision of Rooftop Solar Photo Voltaic Power Plant
i. The mandatory installation of Rooftop Solar Photovoltaic Power Plant for the buildings/ areas shall be in accordance with the directions issued, from time to time.
ii. Installation of Solar Photovoltaic Power Plant as per Code 9.3(i) above, shall be
part of the occupation certificate.
iii. The Competent Authority shall empanel consultants (experts in solar photo voltaic power plant installations) for inspecting, verifying and issuing certification for installation of Rooftop Solar Photovoltaic Power Plant and solar evacuated tube collectors for hot water.
9.4 Provision of Energy Conservation Building Code
i. The provision for Energy Conservation Building Code shall be mandatory applicable on buildings/ areas in accordance with the direction issued by Administration of UT Ladakh from time to time.
ii. The applicant/ owner along with building plan application shall submit a certificate from an architect confirming that the building plans confirms to the Energy Conservation directions.
iii. Occupation certificate of building to be issued by the competent authority only after the applicant/ owner submits a certificate from an architect/engineer (who has supervised the construction of building) that the building has been constructed in accordance with the provision of the Energy Conservation directions.
iv. The applicant/owner shall submit building plans along with the submission of Design Stage and Occupancy Stage ECBC Compliance Forms and/or Simulation Report duly signed and stamped by Bureau of Energy Efficiency (BEE) Approved Empaneled Experts/Firms confirming or from Ladakh UT Level empaneled architect that the building plans and construction confirms to the Energy Conservation directions as per ECBC and Ladakh ECBC 2021 (once notified).
9.5 Recycling of Treated water
i. The sites or buildings in a complex or individual building, discharging water 30,000 liters and above, per day, shall have the treated wastewater recycle system for horticultural, flushing, cooling tower purposes, etc. to increase the vegetal cover and minimize the useof potable water.
ii. The dual pipe system shall be adopted in these buildings and indicated in building plans submitted for approval.
iii. In order to mitigate water pollution, the bulk waste generators including Hotels, restaurants/cafes, laundry, car wash facilities etc. should provide Effluent Treatment Plants to treat wastewater generated from their respective units
iv. Water conservation measures need to be adopted/regulated to maximize the use of treated STP water for non-potable purpose/gardening, construction activity, toilet flushing, etc. as per Code 9.6 (1) and 9.6 (2).
v. Any Govt. of India/UT Ladakh Acts, laws, byelaws, notifications and statutory provisions shall be binding and applicable as notified from time to time.
9.6 Sustainable Habitat
(1) Part-11 Approach to Sustainability of National Building Code need to be
referred for detailed approach to sustainability. This shall include but not be limited to built environment, ecological footprint, renewable resource, 3Rs (reduce, reuse, recycle), sustainable development, thermal conditioning (capacity, conductance, conductivity, etc.), technology options, disaster preparedness, water management, site design and development, external landscaping, fenestration designs, rainwater harvesting, water elements and irrigation, access design, parking, lighting, envelope optimization and materials, along with any other relevant sections.
(2) CPWD Guidelines for sustainable habitat need to be referred to incorporate sustainable architecture and layout planning, sustainable index and guidance of materials, selection of equipment for electrical and mechanical services for sustainable buildings and reuse and recycling of construction & demolition waste. These shall include energy efficiency design and process, site development, building orientation and shading, design strategies for day lighting, building envelope, design strategies in cold climate, reduction in overall embodied energy of building materials, integrated water management, solid waste management, sustainability index, building materials, functional life period, capital cost, building loads (live and dead loads), power saving, lighting, HVAC and solar power, along with any other relevant sections.
(3) The following supplementary building materials (derived or processed from waste) may be suitably used while constructing building in combination with conventional resources in addition to mud bricks:
(i) Panels, hollow slabs, hollow blocks, or other factory materials which consume less water.
(ii) Fly Ash bricks, Portland Pozzolana cement, Fly-ash concrete, phosphor gypsum-based walling & roofing panels, particle wood, Recycled use of industrial/agricultural by-products.
(iii) Fly ash/ AAC (Autoclaved Aerated light weight Concrete) panels/ CLC (Cellular Light weight Concrete) panels- Ensuring thermal comfort.
(iv) Use of timber from rapidly growing plants from environment pointofview.
(v) Compressed Soil Earth Block and Rammed Earth Walls and Vaults.
(vi) Use of Polyurethane Foams (PUF), Extruded Polystyrene (XPS), Expanded Polystyrene (EPS), Rockwool, Glasswool as per the suitability to keep building insulated
Further materials and techniques shall be referred as per Code 9.6(1) and Code 9.6(2) of these Bye-Laws.
(4) Solar passive techniques specific to Ladakh need to be incorporated. This is to include inputs from competent authorities to provide sustainable building techniques, solar passive heating and comfort retention techniques, thermal insulation technologies to provide sustainable solutions to extremities of cold desert climate. The techniques should be in accordance with Code 9.6(1) and Code 9.6(2) of these Bye-Laws for a more inclusive design.