(i) Sub-division of a bigger plot into smaller units is permissible in the case of a family division, in case the plot is not allotted by the development agency. In case a plot has been allotted by the development agency, the prior approval of the competent authority is required. Each such sub-division shall be accessible independently through a street or a public road/street.
(ii) Except as otherwise expressly provided at the time of sale/allotment of plot in a colony under specific scheme approved by the competent authority, not more than one building unit shall be erected on any one plot, however, two or more plots may be combined together under a single ownership for purposes of erection of one “building unit”.
Note:-
“Building unit” means a self-contained building with such outbuildings as are ordinarily ancillary to the main building used in connection therewith and physically incapable of sub-division into two or more
independent building units. A building unit may, however, be owned by an individual or may be jointly and severally owned, provided it remains in a single indivisible ownership.
7.3Proportion of the site which may be covered with buildings
(1) The proportions of covered area of a building, including ancillary buildings, shall be in accordance with the categories of plots given in following sub-Codes and the remaining portion shall be left open in the form of open space around the building falling in the core area identified in the Master Plan or Zonal Development Plan or as notified by the competent authority and other than Core Area.
(2) For General Building Requirements, Chapter-4 of Model Building Bye Laws 2016 needs to be referred.
(3) Chapter 5 & 6 of Model Building Bye Laws, 2016 need to be referred for provisions of high rise and structural safety, as relevant, unless mentioned otherwise
(4) Unless specified in these building bye-Laws, DCRs, or Architecture Control Sheet, the minimum setbacks, permissible heights and any relevant critical sections shall be referred to from Model Building Byelaws, 2016.
(5) Restrictions based on critical areas need to be included, including Airport Authority of India, Archaeological Department, Hazard Risk Mitigation and other critical areas need to be consulted with the relevant authorities, and NOC shall need to be obtained as the case may be.
(6) Relevant group housing requirements need to be referenced with Master Plan/DCR documents. Special provisions for construction of EWS and slums housing based on spatial impact assessment depending on the feasibility of the project, location, and impact shall be taken from Master Plan/DCR Documents. Private developers need to provide 15% for EWS and hand over to ULB at predetermined price; similar reservations need to be explored and provided in the Group Housing wherever relevant.
(7) Core Area land use-wise permissible coverage, floor area ratio and height shall be as follows:
(i) Residential
Sr. No.
Plot area slabs in square meters
Maximum permissible Ground Coverage
Permissible basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height (G+3 Floor) (including stilt (S+4 Floor in meters)
1
Up to 100
80%
Single level
200 %
15.0
2
Above 100 to 200
75%
Single level
200 %
15.0
3
Above 200 to 300
70%
Single level
180 %
15.0
4
Above 300 to 400
65%
Single level
160 %
15.0
5
Above 400
55%
Single level
140 %
15.0
(ii) Commercial
Sr. No.
Plot area slabs Square meters
Maximum permissible Ground Coverage
Permissible basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height
1
up to 50
90%
Single level
200 %
18
2
Above 50 to 100
80%
Single level
200 %
18
3
Above 100 to 200
70%
Single level
180 %
18
4
Above 200 to 400
60%
Single level
160 %
18
5
Above 400
40%
Single level
150 %
18
(iii) Plot setbacks
The buildings shall not project beyond the building lines as shown in the zoning plan of respective schemes/Zonal Development Plans and or as indicated below the minimum setbacks shall be adhered.
Sr. No.
Area of plot (in sq. meters)
Minimum Front Setback (meters)
Minimum Rear Setback (meters)
1.
Up to 50
1.0
-
2.
Above 50 to 150
1.5
1.0
3.
Above 150 to 200
2.5
2.0
4.
Above 200 to 400
3.0
3.0
5.
Above 400 square meters
4.5
4.0
(8) Areas other than core area:
(i) Residential: In the case of Plots; permissible coverage, floor Area ratio and height
Sr. No.
Plot area in Square Meters
Maximum permissible Ground Coverage
Permissible Basement
Maximum permissible FAR
Maximum permissible Height (G+3 Floor) (including stilt (S+4 Floor)) (in meters)
1
Up to100
65%
Single level
160 %
15.0
2
Above 100 to 250
65%
Single level
145 %
15.0
3
Above 250 to 350
60%
Single level
130 %
15.0
4
Above 350 to 500
60 %
Single level
120 %
15.0
5
Above 500
55 %
Double level
100 %
15.0
A. The additional FAR to the extent of 5% within the permissible height can be purchased at the collector’s rates fixed from time to time for the respective localities.
B. Provided that the building shall conform to the restrictions contained in the zoning plans, development control regulations (DCRs) or the architectural control sheets of respective areas.
C. Provided that the 25% of the built-up area of the building not exceeding up to 50 square meters, whichever is less, can be used for non-nuisance professional consultancy services, after getting permission from the competent authority in writing. The applicant shall apply for specific use of consultancy services as mentioned in Code 3.83 in Form NAC-I along with fee as fixed from time to time and the permission shall be granted in Form NPC-II”.
D. Stilt floor is permitted for parking purposes in residential and commercial plots of all sizes, subject to the condition that maximum permissible height of the building shall not exceed 15 meters.
E. Transfer of Development Rights need to be provided in accordance to Master Plan, DCRs and Zoning Regulations [that should include disaster management component, heritage preservation and conservations and other zoning regulations as required].
(ii) Group Housing
Sr. No.
Maximum permissible ground coverage
Permissible Basement
Floor Area Ratio
Maximum Permissible height (m)
1.
40%
Up to two levels
175%
21
A. The height of mumty/lift room/water tank/building maintenance unit are not counted in the building height,
B. The parking requirement of group housing shall be governed by Code 7.1 or as per the national building code updated.
(iii) Commercial
Sr. No.
Type of building
Area Norm
Maximum permissible Ground Coverage
Permissible Basement
Maximum permissible Floor Area Ratio (FAR)
Maxim um permissible Height
1
Individual Shops
No Limit
As per the Architectural Control Sheets relating to façade and height controls in a street.
2
Approved Commercial colony: includes shopping mall, multiplex, Departmental store, Integrated commercial Complex, Service Apartments, starred Hotels/ Unstarred Hotels and Guest Houses, offices.
No Limit
60 %
Two levels
175 %
15
3
Dhabas
500 square meters to 1/2 acre
50 %
One level
50 % (with maximum 50 sqm for kiosks for other items)
5 meters
4
Banquet Hall
Minimum 2.5 acres
50 %
One level
50% (10% FAR allowed for gift shop/STD Booths, Toy Centre and flower shops etc.)
15
5
Resort, 5-star Hotels, Motel (with/without banquet hall facilities)
No Limit
40%
Two levels
175 %
6
Starred Hotels, Restaurants
No Limit
40 %
Two levels
175 % (with permissible 15% commercial component)
18
7
Amusement Park
No Limit
30 %
One Level
50 % (with permissible 15% commercial component)
Unrestricted
8
Big retail stores
No Limit
50%
Two Levels
175%
15
9
Petrol Stations
No Limit
As per terms and conditions of Oil companies.
Note:
For all use cases subject to petroleum and explosive material handling, PESO regulations including Fire clearances are to be recommended
(iv) Institutional and Educational
Plot area slabs (Square meters)
Maximum permissible Ground Coverage
Permissible Basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height
Up to 10000
35 %
Up to two levels
150%
15 m
Above 10000
25 % of such portion of site
Up to two levels
150 %
15 m
A. In the case of educational institutions (Schools/College/University), the Hostel component is restricted to 20% of maximum permissible covered area, and
B. The residential component (i.e., residential facility for principal, teachers/professors, staff, etc.) is restricted to 10% of maximum permissible covered area in addition to hostel component).
C. However, the competent authority may consider the requirement of the project for permitting residential component up to maximum limit of 50% of FAR by recording the reasons of Justification.
(v) Industrial and IT
Sr. No. (v
Type of Industry i) W
Maximum Ground Coverage
Permissible Basement
Maximum Permissible Floor Area Ratio
Maximum Permissible Height
Remarks
1.
Genaeral
60%
Twin level
150 %
30 Meters
--
2.
Apprarel and Footwear
40%
Twin level
200 %
No Restriction
To be located on a road with Right of Way of 12 meters and above.
Apperoved Information Tec/hnology Park, Cyber Park, Cyber City, TecShnology Park t o r
40%
Twin Level
250 %
No Restriction
Subject to condition that the plot must be located on roads with a Right of Way of 15 meters and above.
(vii) Storage/ Godown
Sr. No.
Type of building
Maximum permissible Ground coverage
Maximum permissible Floor Area Ratio (FAR)
Setbacks all around the plot (in meters)
1
Integrated Inland Container Depot/Custom Bounded Area
60%
75 %
8
2
Warehouse other than agricultural produce/Grain Godown/Silos
6
3
Warehouse for Agricultural Produce/Grain Godowns/ Silos
6
4
Gas Go-down
6
(viii) Recreational
Sr. No.
Type of building
Area norms
Maximum permissible Ground coverage
Permissible basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height meters
1
Recreational site in residential zone such as Club/Community Centre including swimming pool, Badminton/Tennis/ Squash Court, Indoor Games, Canteen/ Restaurant (not exceeding 200 square meters area) and related uses. Note: a. Not more than 10% of the permitted FAR to be allowed for rooms. b. Maximum 10% of the total FAR can be utilized for commercial use viz, Canteen/ Restaurants.
0.5acre to 2 acres
40 %
Single level
100 %
15
2
Open Space Zone such as Mini Amusement Park, Outdoor games facility, Canteen (not exceeding200 square meters area) and related infrastructure requiring minimal construction activity Note: The overall character of the site shall be maintained as open with minimum construction to be permitted at site. However, Joy rides/ water parks etc. Installed in such projects, which are open to sky shall not be part of covered area/ FAR.
2 acres to 5 acres
10%
Single level
10%
15
Note:
A. Control of signs (hoardings) and outdoor display structures and transmission tower, telephone tower, mobile/broadband tower and outdoor display structure (Apart from provisions laid down in NBC 2005)
Chapter 7Land Use of Site, Planning and Architectural Control and Coverage
7.1 Use of site, type, and character of building
(i) Type and character of building, including ancillary buildings, that may be erected or re- erected on a site and the purpose for which these may be used shall not be other than that shown in the Mater Plan or Zonal Development Plan, as the case may be or as shown in the approved layout plan of a colony or zoning plan, if any.
(ii) Where the site does not form part of a layout plan or zoning plan, the use shall be in conformity with the use prescribed in the Master Plan or Zonal Development Plan and in case no master plan notified, in that case, the use of the surrounding area will be considered and in such cases the decision of the competent authority shall be final.
(iii) Every building that may be erected or re-erected on a site, in addition to the foregoing restrictions, shall comply with the restrictions shown in the Architectural Control Sheets, wherever applicable which shall have precedence over the Building Bye-Laws.
(iv) Every building that may be erected or re-erected on a site, in addition to other restrictions under these Bye-Laws, shall comply with the provisions made in the National Building Code of India (updated from time to time), wherever these Building Bye-Laws are not applicable.
(v) Facade design to also incorporate Urban Design guidelines to preserve heritage conservation and city identity for the districts. Separate Urban Design guidelines need to be formulated and suitable notification need to be released for the same by the relevant authorities.