The construction of the building/ buildings shall be governed by provisions of the Haryana Building Code, 2017.
[156]
xviii. FIRE SAFETY MEASURES:
(a) The owner will ensure the provision of proper fire safety measures in the multi storied buildings conforming to the provisions of The Haryana Building Code, 2017/ National Building Code of India and the same should be got certified form the Competent Authority.
(b) Electric Sub Station/ generator room if provided should be on solid ground near DG/ LT. Control panel on ground floor or in upper basement and it should be located on outer periphery of the building, the same should be got approved from the Chief Electrical Inspector, Haryana.
(c) To ensure fire fighting scheme shall be got approved from the Director, Urban Local Bodies, Haryana or any person authorized by the Director, Urban Local Bodies, Haryana. This approval shall be obtained prior to starting the construction work at site.
xix. The rain water harvesting system shall be provided as per Code 8.1.
Diode lamps (LED) for its building.
xxi. That the owner shall strictly comply with the Code 8.3 for enforcement of the Energy Conservation Building Codes.
xxii. That the owner shall ensure the installation of Solar Power Plant as per Code 8.2.
[157]
2. Model Zoning Clauses for Commercial Building
i. Code referred in the clause is Haryana Building Code, 2017, amended from time to time.
ii. SHAPE & SIZE OF SITE.
The shape and size of site is in accordance with the demarcation plan shown as ‘ ’ to ‘ ’, as confirmed by Competent Authority, vide drawing no…………….., issued on DD/MM/YYYY.
iii. LAND USE.
The type of buildings use permissible is commercial for retail outlet/ showroom/ shop/ etc. and under no circumstance, the use of building shall be changed.
(a) The type of buildings permitted on this site shall be buildings designated and intended to be used for:
(i) retail outlet including saleroom for lubricants, office room, toilet, store installation of fuel pumps, air filling pumps, underground storage of petrol/ diesel, canopy and way side amenities, like repairs/services shop, ATMs & small eating place (Dhaba/ Fast Food Joint). Fuel tanks shall be provided underground within the site after leaving 1.5 mtrs from the boundary.
(ii) Showroom/ shops including sale of goods.
(b) No other building use shall not be permitted.
(c) The site shall be developed and building constructed thereon as indicated in and explained in the table below:
| Notation | Land Use Zone | Type of Building permitted/permissible structure |
|---|---|---|
| Open Space Zone | Open parking, garden, landscaping features, underground services etc. | |
| Building Zone | Building as per permissible land use in clause-iii above and uses permissible in the open space zone. |
(a) The building or buildings shall be constructed only within the portion of the site marked as Building zone as explained above, and nowhere else.
(b) The proportion up to which the site can be covered with building or buildings on the ground floor and subsequent floors shall be as per Code 6.3(3)(ii).
(c) Maximum permissible FAR shall be as per Code 6.3(3)(ii).
vi. HEIGHT OF BUILDING.
The height of the building block, subject of course to the provisions of the site coverage and FAR, shall be governed by the following:-
(a) The maximum height of the buildings shall be as Code 6.3(3)(ii) and Code 6.3(3)(vii).
(b) If a building abuts on two or more streets of different widths, the buildings shall be deemed to face upon the street that has the greater width and the height of the buildings shall be regulated by the width of that street and may be continued to this height to a depth of 24 metres, along the narrow street.
(c) The plinth height of building shall be as per Code 7.3.
[158]
(d) All building block(s) shall be constructed so as to maintain an inter-se distance as per Code 7.11(5).
(e) If such interior or exterior open space is intended to be used for the benefit of more than one building belonging to the same owner, then the width of such open air space shall be the one specified for the tallest building as specified in (c) above.
vii. PARKING.
(a) Adequate parking spaces, covered, open or in the basement shall be provided for vehicles of users and occupiers, within the site as per Code 7.1.
(b) In no circumstance, the vehicle(s) belonging/ related to the plot/ premises shall be parked outside the plot area.
viii. APPROACH TO SITE.
(a) The vehicular approach to the site shall be planned and provided giving due consideration to the junctions of and the junctions with the surrounding roads to the satisfaction of the Competent Authority.
(b) The approach to the site shall be shown on the zoning plan.
(c) Entry and Exit shall be permitted as indicated/ marked on the plan.
(d) In case of retail outlet no gate and gatepost shall be permitted.
Ix. BAR on Sub-division of Site.
Sub-division of the site shall not be permitted, in any circumstances.
X. Approval of Building Plans.
The building plans of the buildings to be constructed at site shall have to be got approved from the Competent Authority/ any other persons authorized by him, under the provisions of the respective Acts, before starting up the construction.
xi. BASEMENT.
(a) Basements within the building zone of the site shall be provided as per Code 6.3(3)(ii) and shall be constructed, used and maintained as per Code 7.16.
(b) In case of retail outlet basement is not permitted.
Xii. Planning Norms.
The building to be constructed shall be planned and designed to the norms and standards as per Chapter-7 of the Haryana Building Code, 2017, and as approved by the Competent Authority.
Xiii. Provisions of Public Health Facilities.
The W.C. and urinals provided in the buildings shall conform to Chapter 11 of the Haryana Building Code, 2017 and National Building Code, 2005.