(1) The courtyard shall have a minimum area, throughout its height, of not less than the square of one-fifth the height of the highest wall abutting the courtyard. Provided that when any room (excluding staircase bay, bathroom and water-closet) is dependent for its light and ventilation on an inner courtyard, the dimension shall be such as is required for each wing of the building.
(2) Provided that such courtyard shall not be less than 12.0 square metres in area and the minimum width of every such courtyard in any direction shall not be less than 3.0 metres. In determining the said aggregate, floor area of the rooms and verandah abutting on the courtyard, following shall be considered:-
(i) Only one half of the floor area of such rooms and verandahs as abut on another courtyard or an open space or road not less than 6 metres in width shall be taken in account;
(ii) The area of the courtyard for the purposes of this Code shall be the area open to sky, clear of all projections.
56 Inserted/amended vide memo no. Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
[61]
57[7.2(a) Podium
(1) Uses permitted shall be for parking of vehicles, fire and building services/ utilities and landscaping/ recreational use on topmost podium slab which is open to sky, subject to provision of parapet wall of maximum 1.6m height, which shall be free from FAR and ground coverage. In addition, toilets and driver’s rest rooms shall be allowed in podium which shall not be counted towards FAR and ground coverage.
(2) Podium may be permitted in a plot of area 1,500 sq.m or more. Podium may be permitted in one or more levels, however, the total height shall not exceed 30 m above ground level which shall be measured upto finished floor level of roof of podium excluding parapet wall of maximum 1.6m height.
(3) Podium shall only be allowed to be constructed in the zoned area. Further, the requirement of ramps for vehicles shall be as specified in National Building Code, as amended from time to time.
(4) If the podium is not accessible by fire tender, then it should not extend more than 11.0 m beyond the building footprint where fire tender access is provided, unless accessible by fire engine. If accessible to a fire tender, a minimum 7.5 m wide ramp with a maximum slope of 1 in 10 shall be required for fire engine access.
Note: - Where this Code is silent regarding any norm, the provisions of National Building Code, as amended from time to time, shall be followed.]