(2) Habitable room
(i) In case of Group Housing Scheme the dwelling unit having more than one room may have one of the rooms with a clear floor area not less than 7.5 sq. metres with one side not less than 2.4 metres.
(ii) In case of air-conditioned rooms, the height shall not be less than 2.4 metres measured from the surface of the floor to the lowest point of air conditioning duct or false ceiling; and
(iii) All doors and windows shall open directly or through a verandah or to a permanent open space or an open space abutting the building not less than 1.8 metres in width. No portion of a room shall be assumed to be lighted, if it is more than 3 metres or as stated in National Building Code portion.
(iv) 60[The carpet area of any ‘Store’ or ‘Utility Room’ to be provided in any residential building shall not be more than or equal to the minimum area requirement of a habitable room, i.e. 9.5 sqm;
(v) The dining room, drawing room and dining-cum-drawing room shall be considered as a habitable room;
(vi) The provision of lobby exceeding the size of habitable room, i.e. 9.5 sqm in a residential building shall be allowed subject to prior provision of either a drawing room or dining-cum-drawing room.]
59Inserted vide memo no. Misc-2339-ULB-Vol-I/7/8/2025-2TCP dated 08.12.2025
60Inserted vide memo no. Misc-2339-ULB-Vol-II-A/7/5/2006-2TCP dated 25.04.2022. This amendment shall come into force from 25.04.2022.
[64]
(3) Kitchen
(i) In case there is a separate store, the floor area of the kitchen shall be reduced to 4.5 square metres.
(ii) In case of houses constructed on plots up to 100 square metres, the size of the kitchen shall be reduced to 3.8 square metres.
(iii) The kitchen which is intended for use as a dining space also shall have a floor area of not less than 9.5 square metres with a minimum width of 2.45 metres.
(iv) For the purpose of this regulation, a kitchen shall be deemed to be a habitable room and all the aforementioned requirements regarding ventilation shall apply to it provided that the minimum area of the kitchen shall not be less than 5.5 square metres with a minimum width of 1.8 metres.
(v) In case of Group Housing Scheme the minimum area of the kitchen shall not be less than 5.5 square metres with a minimum width of 1.8 metres.
(4) Bathroom and Water Closet (W.C):
(i) Every bathroom and water closet shall: -
(a) preferably be so situated that at least one of its walls shall have opening for circulation of external air, with provision of exhaust fan.
(b) 61[not be directly over any room other than another W.C, washing place, bath or terrace unless it has a water-tight floor (only in case of toilet fixtures affixed at sunken slab);]
(c) have a platform or seat made of water tight non-absorbent materials;
(d) preferably be enclosed by walls and partitions and the surface of every such walls or partition, shall be finished with a smooth impervious material to a height not less than 1.5 metres above the floor of such room; and
(e) Be provided with impervious floor covering sloping towards the drain with a suitable gradient and not towards verandah or any other room.
61 Inserted/amended vide memo no. Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
[65]
(ii) 62 [Where the water-closet room in a building is not connected to exterior, it shall be ventilated by mechanical means or through a vertical shaft open to sky of a minimum size stated at Code 7.11(6) for ventilation to toilet, bath and water closet, but it shall be counted towards covered area.]
(iii) No room containing water-closet shall be used for any other purposes except as lavatory and no such room shall open directly into any kitchen or cooking space by a door/ window or another opening. Every room containing watercloset shall have a door completely closing the entrance to it.
(iv) Soil or ventilating pipes shall not be allowed on the exterior face of any building, provided these shall either be embedded in the walls or pipe ducts to be provided to accommodate them.
(v) Security rooms each measuring maximum area of 3.0 square metres is permitted only at the entry and exit gates of premises.