Chapter 6Siting, Planning and Architectural Control
6.1 Use of site, type and character of building.
(1) Type and character of building, including ancillary buildings, that may be erected or re-erected on a site and the purpose for which these may be used shall not be other than that shown in the Development Plan or the approved layout plan or sector plan or zoning plan.
(2) Where the site does not form part of such layout or sector plan or zoning plan, the use shall be in conformity with the use of the surrounding area, or use prescribed in development plan and the decision of the Competent Authority shall be final in this respect.
(3) Every building that may be erected or re-erected on a site shall, in addition to the foregoing restriction, comply with the restriction shown the Architectural Control Sheets, wherever applicable, shall have precedence over the zoning plan or the building Code.
(4) Every building that may be erected or re-erected on site shall, in addition to other restrictions under this Code, comply with the provisions made in the National Building Code of India (amended from time to time), wherever this building Code is silent.
6.2Sub-division and amalgamation of plots
(1) Division of plot into smaller units is permissible in core areas with the prior approval of the Competent Authority. Each such plot shall be accessible separately and independently through a public road laid out and constructed to the satisfaction of the Competent Authority.
(2) Except as otherwise expressly provided at the time of sale or the colony approved under specific scheme by the Competent Authority, not more than one building unit shall be erected on any one plot, but in any case two or more plots may be combined for purposes of erection of one “building unit”.
Note:-“Building unit” means a self-contained building with such out buildings as are ordinarily ancillary to the main building used in connection therewith and physically incapable of sub-division into two or more independent building units. A building unit may, however, be owned by an individual or may be jointly and severally owned, provided it remains in a single indivisible ownership
(3) The Competent Authority shall be competent to refuse permission for construction on consideration of compact and economical development of the area till such time as availability of water supply, drainage arrangement, and other facilities are ensured to his satisfaction.
(4) In case plots which are to be amalgamated are back to back, then rear setback shall be maintained as per already approved zoning plan.
(5) In case plots adjacent plots are to be amalgamated, then setbacks shall be maintained as per zoning plan approved by the Competent Authority for whole amalgamated plot.
(6) Amalgamation of adjacent plots (side by side or back to back or both) where building stand constructed is permitted, subject to the condition that the constructed buildings shall not violate the provisions of zoning plan issued by the competent authority for the amalgamated plot.
6.3Proportion of the site which may be covered with buildings.
(1) The proportions of covered area of a building, including ancillary buildings, shall be in accordance with the plot categories given in following sub-Codes and the remaining portion shall be left open in the form of open space around the building.
(2) Core Areas
(i) Residential
Sr. no.
Plot area slabs
Maximum permissible Ground Coverage
Permissible basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height (G+3 Floor) (including stilt (S+4 Floor)) (in metres)
1
Upto 60 square metres
85%
Single level
220 %
15.0
2
Above 60 to 150 square metres
80%
Single level
200 %
15.0
3
Above 150 to 225 square metres
70%
Single level
180%
15.0
4
Above 225 to 450 square metres
60%
Single level
160 %
15.0
5
Above 450 square metres
50%
Single level
140 %
15.0
(ii) Commercial
Sr. no.
Plot area slabs
Maximum permissible Ground Coverage
Permissible basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height
1
upto 50 square metres
100%
Single level
200 %
Unrestricted
2
Above 50 to 150 square metres
85%
Single level
200 %
Unrestricted
3
Above 150 to 225 square metres
75 %
Single level
200 %
Unrestricted
4
Above 225 to 450 square metres
60 %
Single level
175 %
Unrestricted
5
Above 450 to 1000 square metres
40%
Single level
175 %
Unrestricted
Note: Example for calculating FAR and ground coverage as per plot area slabs for 14 marla and 1 Kanal plot:
Calculations for Ground Coverage
Plot area slabs
Area in each slab (in square metres)
Maximum permissible Ground Coverage
14 marla plot (354.1 square metres)
1 Kanal plot (505.86 square metres)
Upto 75
75
66
49.5
49.5
76-100
24
66
15.84
15.84
101-150
49
60
29.4
29.4
151-250
99
60
59.4
59.4
251-350
99
50
49.5
49.5
351-500
149
50
4.05
74.5
501-1000
499
45
4.8861
207.69
283.0261
Actual permissible ground coverage
58.6529229
Cal
culations for Floor Area Rati
o (FAR)
Plot area
Area in each slab
Maximum permissible
14 marla(354.1
1 Kanal(505.86
slabs
(in square metres)
Floor Area Ratio (FAR)
square metres)
square metres)
Upto 75
75
165
123.75
123.75
76-100
24
165
39.6
39.6
101-150
49
145
71.05
71.05
151-250
99
145
143.55
143.55
251-350
99
125
123.75
123.75
351-500
149
120
9.72
178.8
501-1000
499
100Actual permissible FAR
511.42144.4281276
10.858691.358136.6703699
(iii) Plot setbacks (core areas)
The buildings shall not project beyond the building lines as shown in the zoning plan of respective schemes. However, in case where zoning plans are not prepared, the minimum setbacks shall be provided as below:-
Sr.
Area of plot (in square
Minimum Front Setback
Minimum Rear Setback
No.
metres)
(in metres)
(in metres)
1.
Upto 60 square metres
0.5
0.5
2.
Above 60 to 150 square metres
1.5
1.0
3.
Above 150 to 225 square metres
2.5
2.0
4.
Above 225 to 450 square metres
3.0
3.0
5.
Above 450 square metres
4.5
4.0
(a) The front setbacks can be adjusted to achieve permissible Ground Coverage subject to the condition that rear setbacks are fixed.
(b) In core areas single level basement may be allowed upto the maximum roof height of not more than 1.5 metres from the ground level for the area of maximum permissible coverage and after that till the zoned area, the roof of basement shall flush with the ground level.
(3) Areas other than core areas
(i) Residential
(a) Plotted
Sr. no.
Plot area
Maximum permissible Ground Coverage
Permissible Basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height (G+3 Floor) (including stilt (S+4 Floor)) (in metres)
1
Upto 100 square metres
66%
Single level
165 %
15.0
2
Above 100 to 250 square metres
66%
Single level
145 %
15.0
3
Above 250 to 350 square metres
60%
Single level
130 %
15.0
4
Above 350 to 500 square metres
60 %
Single level
120 %
15.0
5
Above 500 to 1000 square metres
60 %
Single level
100 %
15.0
Note:
I. The additional FAR is allowed on payment of charges as approved by Government from time to time.
II. Provided that the building shall conform to the restriction contained in the zoning plans or the architectural control sheets of respective area of sector.
III. Provided further that in case of sites measuring 100 square metres or less under any scheme relating to houses for economically weaker
section framed by the Government, Housing Board, Improvement Trust or any other authority, the Competent Authority may relax the above condition.
IV. Provided further that the 25% of the built up area of the building or upto 50 square metres, whichever is less, can be used for non-nuisance professional consultancy services, after getting permission from Competent Authority in writing. The applicant shall apply for specific use of consultancy services as mentioned in Code 1.2(1)(lx) in Form N-I along with fee as mentioned in Schedule IV-A. The permission shall be granted in Form N-II”.
V. The stilts are permitted for parking purposes in residential and commercial plots of all sizes, subject to the condition that maximum permissible height of building shall not exceed 15 metres.
(b) Group Housing
Sr. No.
Maximum permissible ground coverage
Permissible Basement
Floor Area Ratio
Maximum Permissible height
1.
35%
(vi) Recreational
Sr. no.
Type of building
Area norms
Maximum permissib le Ground coverage
Permissi ble baseme nt
Maximum permissible Floor Area Ratio (FAR)
Maxmi mum permis sible height
1
Recreational site in residential zone such as Club/ Community Centre including swimming pools, Badminton/ Tennis/ Squash Court, Indoor Games, Canteen/ Restaurant (not exceeding 200 square metres area) and related uses. Note: a. Not more than 10% of the permitted FAR to be allowed for rooms. b. Maximum 10% of the total FAR can be utilized for commercial use viz, Canteen/ Restaurants.
0.5acre to 2 acres
35 %
Single level
100 %
Unrestr icted
2
Open Space Zone such as Mini Amusement Park, Outdoor games facility, Canteen (not exceeding 200 square metres area) and related infrastructure requiring minimal construction activity Note: The overall character of the site shall be maintained as open with minimum construction to be permitted at site. However, Joy rides/ water parks etc. Installed in such projects, which are open to sky shall not be considered to be part of covered area/ FAR.
2 acres to 5 acres
10%
Single level
10%
Unrestr icted
(vii) Mixed land use
In case of mixed land use site/ plot, the ground coverage, FAR, setback and other norms shall be in accordance with the zoning plan issued by Competent Authority.
(viii) General note:-
(a) The unrestricted height shall only be allowed subject to submission of No Objection Certificate from the appropriate authority (i.e. Defence Establishment, Air Force Establishment, Airport Authority of India, etc.), if any in the area.
Note: It is the responsibility of the competent authority to procure the zoning map/ instructions issued by the appropriate authority (i.e. Defence Establishment, Air Force Establishment, Airport Authority of India, etc.), if any present in its jurisdiction.
(b) The basement may be allowed to the maximum roof height of not more than 1.5 metres from the ground level for the foot print of the building and after that till the zoned area, the roof of basement shall be flush with the ground level.
6.4Architectural/ Frame Control and siting of building.
(1) In the case of building sites where architectural control is considered necessary by the Competent Authority, he shall cause to be prepared Architectural Control Sheets for this purpose showing the extent of architectural control on the various units of the buildings or on a portion of such buildings, among others in the following respects:-
(i) Compulsory elevations for a particular building or a row of buildings.
(ii) Compulsory height on the front or on any side exposed to view from a street upon which building shall have to be erected and completed within a certain period.
(iii) Compulsory height of floors.
(iv) Compulsory height and design of cornices, sills and top of windows in the first and higher storeys.
(v) Compulsory building line along which the building shall have to be erected and completed within a certain period.
(vi) Compulsory type designs of balconies.
(vii) Compulsory use of materials texture and colour.
(2) Building line in front, rear and side shall be as per the zoning plan approved by the Competent Authority.
(3) Special zoning:
In case competent authority decides that it is not feasible to keep setbacks/ spaces as prescribed above due to peculiar shape and condition of the site, then the competent authority after recording reasons in writing may issue special zoning plan, keeping in view the fire safety.
(4) Frame Control:
No frame control shall be applicable on residential plotted buildings.
6.5Green building measures and incentives
(1) For reducing consumption of total energy, fresh potable water and reduction in total waste generation by modern buildings, the green building measures are to be adopted by all building on various plot sizes above 500 square metres.
(2) The applicant shall be awarded benefits of additional Floor Area Ratio (on plot area) for adopting either green norms specified in sub-Code (3) or by getting his building/ site/ project certified from Green Rating for Integrated Habitat Assessment (GRIHA) and achieving rating as specified in Code 6.5 (4):
(3) The details of green norms and additional Floor Area Ratio (FAR):
(i) For installing solar photovoltaic power plant:
Generating power in respect of total connected load of building from solar photovoltaic power plant
15 to 25%
26 to50%
51 to75%
76 to 100%
Additional FAR for all building uses (except plotted residential)
3%
6%
9%
12%
(ii) For installing Solid Waste Management Plant:
Installing Solid Waste Management Plant for treatment of total generated waste.
Additional FAR for all building uses (except plotted residential)
3%
(4) The details of rating achieved from GRIHA and Additional Floor Area Ratio (FAR) is as under:
Additional FAR for all building uses (except plotted residential)
3%
6%
9%
12%
15%
GRIHA rating
1 star
2 star
3 star
4 star
5 star
Note:
a. The additional FAR shall be given over and above the maximum permissible FAR as stated in Code 6.3.
b. The incentive of additional FAR for achieving GRIHA rating shall be applicable only on new buildings.
c. The applicant has to pay only Infrastructure Development Charges on additional FAR granted as incentive under Code 6.5.
(5) Procedure for availing incentive:
(i) The applicant is required to submit provisional rating from GRIHA at the time of submission of building plan application to the Competent Authority (Code 4.1 and 4.2) for claiming incentive of additional FAR stated at Code 6.5 (4).
(ii) At the time of applying for Occupation Certificate of building, the applicant is required to submit final rating from GRIHA.
(iii) The Competent Authority only after verifying that the GRIHA rating achieved in final rating is same as provisional rating submitted at the time of building plan application, shall issue the Occupation Certificate:
Provided, in case the final rating achieved is lesser than the provisional rating, the occupation certificate shall be issued after compounding the additional FAR (i.e. difference of additional FAR from provisional rating and final rating) acquired by the applicant, at ten times the rates of EDC applicable at the time of submission of occupation certificate application.
Provided, the applicant may claim additional FAR, if final rating is higher than the provisional rating.
(iv) The applicant has to submit a rating certificate for the building from GRIHA/ Compliance Certificate with respect to clause 6.5 (3) [duly issued by Architect or Engineer or Bureau of Energy Efficiency Certified Energy Auditors as the case may be] is to be submitted after every 5 years. In case, he fails to submit this certificate, the authority, after giving him one month notice may charge the compounding fee or may take appropriate action on case case basis by recording the reasons in writing, thereof.
Upto four levels
175%
Unrestricted
Note:
I. The height of mumti/ lift room/ water tank/ Building Maintenance Unit shall be exclusive of building height;
II. The parking requirement of group housing shall be governed by Code 7.1 or any other policy issued by the Government in this regard, from time to time.
(ii) Commercial
Sr. no.
Type of building
Area norm
Maximum permissib le Ground Coverage
Permissib le Basement
Maximum permissible Floor Area Ratio (FAR)
Maxim um permis sible Height
1
Shop-cum-Flat (SCF) or Shop-cum-Office (SCO) or Shop-cum-Office-cum-Flat (SCOF) or Double Storey Shop (DSS) purposes or for shopping booths
Unrestric ted
As per the Architectural Control Sheets
As per the Architectural Control Sheets
As per the Architectural Control Sheets
As per the Architectural Control Sheets
2
Commercial colony: includes shopping mall, multiplex, Departmental store, Integrated commercial Complex, Service Apartment, starred Hotel/ Unstarred Hotel, offices.
Unrestric ted
60 %
Unrestricte d
175 %
Unrestri cted
3
Dhabas
1000square metres to 1 acres
40 %
Unrestricte d
40 %(maximum 50 sqm for kiosks like STD, Books, Cassettes, CDs etc.)
5metres
4
Banquet Hall
Minimum 2.5 acres
50 %
Unrestricte d
50%(10% FAR allowed for gift shop/STD Booths, Toy Centre and flower shops etc.)
Unrestri cted
5
Starred Hotels, Restaurants
Unrestric ted
40 %
Unrestricte d
175 %(with permissible15%commercial component)
Unrestri cted
6
Amusement Park
Unrestric ted
30 %
Unrestricte d
50 %(with permissible15%commercial component)
Unrestri cted
7
Resort, 5 star Hotels, Motel (with/ without banquet hall facilities)
Unrestric ted
30%
Unrestricte d
175 %
Unrestri cted
8
Big box retail stores
Unrestric ted
60%
Unrestricte d
175%
Unrestri cted
9
Petrol Stations
Unrestric ted
As per terms and conditions of Oil companies.
As per terms and conditions of Oil companies.
As per terms and conditions of Oil companies.
As per terms and conditions of Oil companies.
(iii) Institutional and Educational
Plot area slabs
Maximum permissible Ground Coverage
Permissible Basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height
Upto 10000 Square metres
35 %
Upto four levels
150%
Unrestricted
Above 10000 square metres
25 % of such portion of site
Upto four levels
150 %
Unrestricted
(iv) Industrial and IT
Sr. No.
Type of Industry
Maximu m Ground Coverag e
Permissi ble Baseme nt
Maximum Permissible Floor Area Ratio
Maximum Permissib le Height
Remarks
1.
General
60%
Twin level
150 %
30 Metres
--
2.
Apparel and Footwear
40%
Unrestric ted
250 %
Unrestricte d
To be located on roads with a Right Of Way of 15 metres and above.
3.
Biotechnology other than Pharmaceuticals
4.
Information Technology/Information Technology Enable Services
5.
Information Technology Park, Cyber Park, Cyber City, Technology Park
40%
Unrestric ted
250 %
Unrestricte d
Subject to condition that the plot must be located on roads with a Right Of Way of 30 metres and above.
Note for above Code 6.3(3)(ii), (iii) and (iv):
a. Unrestricted basement means as many numbers of basements subject to fulfilment of parking norms and/ or storage requirements and/ or use of maximum permissible FAR (in case of habitable use of basement) required in accordance to use of building.
b. Four levels basement shall be allowed only on site having area more than 8000 square metres & in other cases as decided by Competent Authority.
c The facility of enhanced FAR beyond the General level of 125% in industrial use shall be permissible on payment of proportionate charges/ infrastructure strengthening charges as prescribed by the Government/ Development Agency.
d. The facility of enhanced FAR of 25% beyond the General level of 150% in resorts, five star hotels, motels (with/without banquet hall facilities) shall be permissible on payment of proportionate charges/ infrastructure strengthening charges as prescribed by the Government/ Development Agency.
The facility of enhanced FAR of 50% beyond the general level of 100% in institutional and educational use shall be permissible subject to payment of proportionate increasing EDC & conversion charges at existing rates (in the form of augmentation charges) for the existing buildings i.e. Building Plans are approved before 30.06.2016. However, no such payment is required for such buildings whose building plans are approved by competent authority after 30.06.2016.
(v) Ware house/ Storage/ Godown
Sr. no.
Type of building
Maximum permissible Ground coverage
Maximum permissible Floor Area Ratio (FAR)
Setbacks all around the plot (in metres)
1
Integrated Inland Container Depots/ Custom Bounded Areas
60%
75 %
15
2
Warehouse other than agricultural produces/ Grain Godowns/ Silos
9
3
Warehouse For Agricultural Produces/ Grain Godowns/ Silos
6
4
Gas Go-down
As per zoning plan
Note:
If a warehouse contains storage of agro produce and also products other than agriculture produce, then the setbacks of 9 metres shall be followed.