(i) High Rise Buildings / Complexes shall be permissible only in areas other than those given in Annexure - I & II.
(ii) The minimum size of plot for High Rise building shall be 2000sq.m.
(iii) In respect of sites proposed for high rise buildings and affected in road widening where there is shortfall of the net plot size, up to 10% of such shortfall in net plot area would be considered with the proposed height and corresponding minimum all round setbacks.
(iv) Every application to construct or reconstruct a High Rise building or alteration to existing High Rise building shall be made in the prescribed form and accompanied by detailed plans, floor plans of all floors along with complete set of structural drawings and detailed specifications duly certified by a qualified licenced structural engineer.
(v) Prior Clearance from Airport Authority:
For any High Rise Building located in the vicinity of airports as given in the National Building Code, the maximum height of such building shall be decided in consultation with the Airport Authority and shall be regulated by their rules / requirements.
(vi) Prior No Objection Certificate (NOC) from the Andhra Pradesh State Disasters Response & Fire Services Department:
For all High Rise Buildings prior No objection Certificate (NOC) from the Andhra Pradesh State Disasters Response & Fire Services Department shall be obtained and copy of the approved plan and No Objection Certificate (NOC) issued by the said department shall be enclosed along with the building application.
(vii) In every high rise building site, an organized open space shall be utilized as greenery, tot lot or soft landscaping, etc. shall be provided over and above the mandatory setbacks to be left in and around the building. This space shall be at least 10% of total site area at ground level open to sky and shall be a minimum width of 3m. This may be in one or more pockets with minimum area of 50sq.m at each location.
(viii) In addition to the above, a minimum of 2m wide green planting strip in the periphery on all sides within the setbacks are required to be developed and maintained.
(ix) Buildings abutting major road of 30m and above width shall be permitted only after providing black-topped service roads of minimum 7m width with minimum 2 Lane carriageway with in the defined right of way. It will be the responsibility of the developer / builder / owner to provide the above service road of the standards fixed by the Sanctioning Authority at his own cost. The Sanctioning Authority may consider sanctioning building permission if the developer / builder / owner deposits the full cost for laying such service road to the Sanctioning Authority. The amount so levied and collected shall be maintained in a separate exclusive account by the Sanctioning Authority and utilized only for this purpose.
(x) The minimum abutting road width and all round open space / setback for High Rise Building / Complex shall be as follows:
TABLE – IV
Height of building (in meters)
Minimum abutting road width required (in meters)
Minimum all-round open space on remaining sides (in meters) *
above
Up to
1
2
3
4
-
21
12
7
21
24
12
8
24
27
18
9
27
30
18
10
30
35
24
11
35
40
24
12
40
45
24
13
45
50
30
14
50
55
30
16
After 55m 0.5m additional setback for every 5m of height shall be insisted
(xi) * The front open space shall be on the basis of the abutting road width and shall be either as given in Col. 4 of above Table - IV or the Building Line given in Table - III of rule-5 whichever is higher.
(xii) The open space to be left between two blocks shall be equivalent to the open space mentioned in Col. 4 of above Table – IV and this shall not be considered for organized open space (Tot lot).
(xiii) In case of high rise buildings up to 30m height, it is permitted to transfer up to 2m of setback from one side to the other side, which needs to be uniform at any given point, subject to maintaining of minimum setback of 7m on all sides subject to not exceeding the permissible / allowable plinth area.
(xiv)The balcony projection of up to 2m may be allowed projecting onto the open spaces for upper floors from 6m height onwards.
(xv) Where the lighting and ventilation of a building is through the means of a chowk or inner courtyard or interior open space/duct, such open space shall be open to sky and area of at least 25sq.m and no side shall be less than 3m.
(b) Tower and Podium Type Building:
(i) Height of the building shall be allowed up to 50m.
(ii) For Podium, i.e., Ground plus first floor: alround setbacks shall be 7m.
(iii) For Tower block: The coverage and alround setbacks shall be minimum 50 % of the Podium Block, and shall be atleast 3m from the Podium edge on all sides,
(iv) The fire safety and fire escape measures for the Tower Block shall be independent of the Podium Block.
(c) “Stepped Type” or “Pyramidal Type” Building:
Such type of High Rise Building blocks may be allowed for heights above 30m with the following open space requirements:
(i) At Ground level: Minimum 9m all round open space for the first five floors.
(ii) At Upper floors: Increase of 1m all round open space or more, for every 5 upper floors or 15m height or part thereof, over and above the ground level open space of minimum 9m.
(d) Multiplex Complexes:
In case of Multiplex Complexes, “The Andhra Pradesh Rules for Construction and Regulation of Multiplex Complexes, 2007” issued vide G.O.Ms.No. 486, Dt.07.07.2007 shall be followed (Annexure-III).
(b) High Rise Buildings: in addition to the above the following conditions shall also be complied with
(i)In addition to the required staircases and lifts, there shall be at least one fire escape staircase and lift. These staircases and lifts shall be got certified from the manufacturer’s authorized service technical personnel from time to time.
(ii) Such buildings shall be undertaken by owners by engaging registered architect, licenced builders / developers and licenced structural engineers. The designs and building plans shall be countersigned by the owner, licenced developer, registered architect, licenced engineer and a qualified & licenced Structural Engineer who shall be responsible for the supervision, structural safety, fire safety and specifications compliance of such buildings.
(iii) Provision for power generator shall be made.
(iv) These buildings shall be planned, designed and constructed to ensure fire safety requirements are met and maintained and shall comply in accordance with the Fire Protection Requirements of National Building Code of India (NBC)-2005 / Andhra Pradesh Fire Services Act,1999.
(v) The facilities for providing fire protection and firefighting facilities in such buildings should be in compliance with the stipulations laid down and clearance issued by the Andhra Pradesh State Disasters Response & Fire Services Department from time to time. No Objection Certificate (NOC) from the Andhra Pradesh State Disasters Response & Fire Services Department shall be obtained from time to time regarding the fire safety requirements and facilities installed. The designs and installations regarding fire protection and safety measures including exit requirements and smoke containment and smoke management measures shall be undertaken through a fire engineer / fire consultant.
(vi) Buildings shall be designed for compliance with earth quake resistance and resisting other natural hazards. The Completion Certificate shall mention that the norms have been followed in the design and construction of buildings for making the buildings resistant to earthquake, compliance with structural safety and fire safety requirements.
16. CONCESSIONS IN ROAD WIDENING CASES:
(a) Where any land or site or premises for building is affected in the Statutory Plan / Master Plan Road or Circulation network or a road required to be widened as per Road Development Plan, such area so affected in the road or circulation network shall be surrendered free of cost to the Sanctioning Authority by the owner of land. No development permission shall be given unless this condition is complied with.
(b) Upon surrendering such affected area the owner of the site would be entitled to a Transferable Development Right (TDR) as given in Rule-17. OR
The owner shall be allowed to construct an extra floor with an equivalent built area for the area surrendered subject to mandated public safety requirements.
(d) Guidelines on Transferable Development Right:
In order to adopt uniform guidelines throughout the State the following conditions and guidelines are prescribed.
(i) As and when the owner of the building intends to construct the building in the remaining area of the site, he is entitled to construct the building as per the provisions of these Building Rules. In the event the owner doesn't take up any construction, the owner is entitled for TDR which can be used I disposed depending on convenience.
(ii) A composite Register shall be maintained by the Sanctioning Authority as per the proforma enclosed at Annexure -VIII on the award of TDR and its sale / disposal and utilization. A responsible officer shall be the custodian of the Register.
(iii) At the time of sale / disposal / utilization of a particular TDR, the utilization details of the sale / disposal need to be entered at relevant columns in the register and that therefore the relevant file need to be referred to the custodian of the Register for making necessary entries in the register. The custodian is held responsible to enter relevant details in the register and also to enter utilization details in the TDR. When TDR Certificate is sold / utilized totally, the same shall be surrendered by the owners and the custodian shall take possession of the Certificate and make necessary entries in the register. As per Government Orders, TDR award is to be arrived on the basis of relevant land value at both export and import areas as per prevailing Registration value.
(iv) TDR can either be sold or can be utilized by the same owner depending on convenience.
(v) TDR can be allowed to be utilized for construction of one additional floor over the normal permissible floors without insisting additional setbacks subject to compliance of other norms.
(vi) Every TDR sold or disposed shall be accompanied by a prescribed agreement on Rs.l00/ - non-judiciary stamp paper between the person disposing the TDR and the person who intend to utilize the TDR. Draft agreement as per Annexure - XI.
(e) Hospital Buildings with more than 30m height
In case of Hospital Buildings with more than 30m height, “The Andhra Pradesh Fire Prevention and Safety measures in High Rise Hospital Buildings (above 30m height) Rules 2011” issued vide G.O.Ms.No.2, Dt.03.01.2011 shall be followed (Annexure-IV).
8. GROUP DEVELOPMENT SCHEMES:
(a) The minimum site / plot area shall be 4000sq.m.
(b) The minimum abutting existing road width shall be 12m and black topped.
(c) If the site is not abutting to an existing road, the proposals should be promoted with the immediate improvement of the accessibility of the site from the nearest main road by way of an approved Road Development Plan by the Competent Authority with a minimum width of 12m which
should be implemented by the Licenced Developer within a period of three years.
(d) Group Development Schemes shall be considered where the site is developed together with construction of building and all amenities and facilities and not disposed as open plots.
(e) All such applications shall in addition to the requirements under these Rules be accompanied by the provisional plans of.
(i) A Services and Utilities Plan as per standards for water supply system, drainage and storm water disposal system, sewerage system, rain water harvesting structures, and for other utilities.
(ii) A Landscaping plan including rain water harvesting / water recycling details.
(iii) Parking & Internal Circulation Plan along with common pool parking area plan, if any.
(f) The above shall be drawn to suitable scale with relevant details.
(g) Minimum of 10% of site area shall be earmarked for organised open space and be utilised as greenery, tot lot or soft landscaping, etc. and shall be provided over and above the mandatory setbacks. Such open space shall be open to sky with a minimum width of 3m. This may be in one or more pockets with minimum area of 50sq.m at each location.
(h) No additional or proportionate open space charges need to be levied in such schemes.
(i) These shall not be applicable in case of Government sponsored Housing Scheme / approved Non Government Organisations (NGOs) or private schemes, and the guidelines and requirements as given in the National Building Code for Low Cost Housing / Government orders shall be followed.
(j) The Building setbacks shall be as per the type of housing & requirements given above for the said type of housing and as per Table - III of rule-5 and Table – IV of rule-7. The open space to be left between two blocks also shall be equivalent to the setback mentioned in Column -10 of Table-III of rule-5 and Column - 4 of Table- IV of rule-7 as the case may be.
(k) A thorough public access road of 12m width with 2-lane black-topped is to be developed within the applicant’s site on any one side at the periphery / as per suitability and feasibility for the convenience of accessibility of other sites and lands located in the interior. This condition would not apply if there is an existing abutting peripheral road on any side.
(l) In case of blocks up to 12m height, access through pathways of 6m width branching out from the internal roads / loop road would be allowed. All internal roads and pathways shall be developed with good design, practices, good built environment and standards.
(m)Road requirements:
9m to 18m for main internal approach roads;
9m for other internal roads and also for looped roads.
8m for cul-de-sacs roads (with a minimum radius 9m.) between 50-100m length.
(n) All roads and open spaces mentioned in this Rule shall be handed over to local body at free of cost through a registered gift deed before issue of occupancy certificate. The society / association may in turn enter into agreement with the local authority for utilizing, managing and maintaining the roads and open spaces. In case of any violation or encroachment, the local authority shall summarily demolish the
encroachments and resume back the roads and open spaces and keep it under its custody.
9. ROW TYPE HOUSING / ROW TYPE SHOPPING PRECINCTS:
(a) Row Houses shall abut internal roads only.
(b) Minimum site area shall be not less than 1000sq.m.
(c) Minimum size of individual plot shall be 50sq.m.
(d) Maximum plot size shall be 125sq.m.
(e) Number of plots in a row shall not be more than 8.
(f) Separation between two blocks shall not be less than 6 m which may be an open space or an alley/pedestrian plaza.
(g) Only internal staircase is allowed.
(h) Minimum width of internal roads: 9m.
(i) Internal cul-de-sac road 6m with maximum length 50m is allowed.
(j) Minimum open space : 10 % of site area.
(k) Height permissible:
i. Ground + 1 floor or 7m in plot area up to 100sq.m.
ii. Ground + 2 floors or 10m in plot area of above 100sq.m.
(l) Minimum setbacks: Front 3m ; Rear 1.5m.
(m) The setbacks in a row can be interchangeable.
(n) In case of row type shopping precincts, back to back shops with above front setback of 3m would be allowed.
(o) In case of very large projects more than 5 acres, common amenities and facilities like shopping center, community hall/club house etc. are required to be provided in minimum 5 % of the site area.
(p) In case of Row Type Shopping Precincts, common basement parking in one or more levels would be permissible subject to conditions mentioned in Rule -13.
10. CLUSTER HOUSING
(a) Minimum site area shall be not less than 1000sq.m.
(b) Minimum plot size 25sq.m with maximum number of 20 houses in a cluster.
(c) Minimum size of cluster open space 36sq.m with a minimum width of 6m.
(d) Height permissible 2 floors or 6m.
(e) Minimum access road 9m.
(f) Internal access may be through pedestrian paths of 6m.
(g) Minimum space between two clusters shall be 6m which may be utilised as pathway / alley.
(h) Building setbacks: No setbacks are needed for interior clusters as the lighting and ventilation is either from the central open space of cluster and the surrounding pedestrian pathway / access road of the cluster. However, interior courtyards may be provided for larger plots and building areas to facilitate lighting and ventilation. For end clusters sides that are abutting peripheral thoroughfare roads or property boundary, setback / building line shall be as per Table – III of rule-5.
(i) In case of very large projects more than 5 acres, common amenities and facilities like shopping center, community hall/club house etc. are required to be provided in minimum 5 % of the site area.
11. PROVISIONS FOR ECONOMICALLY WEAKER SECTION (EWS) / LOW INCOME GROUP (LIG) HOUSING CATEGORY
(a) In case of areas falling in Hyderabad Metropolitan Development Authority (HMDA), Visakhapatnam Urban Development Authority (VUDA), Vijayawada–Guntur–Tenali–Mangalagiri Urban Development Authority
(VGTMUDA) where the proposed site area for residential projects is 4000sq.m and above, the developer shall provide at least 20% of developed land for Economically Weaker Sections (EWS) and Low Income Groups (LIG) housing in such projects.
(b) In case of areas falling in Municipal Corporations and the Urban Development Authorities in the State except Greater Hyderabad Municipal Corporation, Greater Visakhapatnam Municipal Corporation, Vijayawada Municipal Corporation, Guntur Municipal Corporation, HMDA, VUDA, VGTMUDA areas where the proposed site area for residential projects is 3000sq.m and above, the developer shall provide at least 20% of developed land for Economically Weaker Sections (EWS) and Low Income Groups (LIG) housing in such projects.
(c) In case of areas falling in Municipalities / Nagar Panchayats constituted under the provisions of the Andhra Pradesh Municipalities Act, 1965 and excluding the Municipalities which are within the jurisdiction of any Urban Development Authority where the proposed site area for residential projects is 2000sq.m and above, the developer shall provide at least 20% of developed land for Economically Weaker Sections (EWS) and Low Income Groups (LIG) housing in such projects.
12. BUILDINGS WITH CENTRAL COURTYARD FOR COMMERCIAL USE:
(a) ‘U’ type commercial buildings with central courtyard are allowed with a minimum plot area of 2000sq.m with the following conditions:
(b) The Front setback shall be as per Table-III of rule-5 & Table-IV of rule-7 for Non High Rise & High Rise buildings respectively.
(c) The minimum open space / setback on sides and rear except front, shall be
(i) 2m for building height up to 15m;
(ii) 3m for building height up to 18m;
(iii) 7m in case of high rise buildings up to 30m height and buildings coming under purview of Andhra Pradesh Fire Services Act-1999.
(d) The area so saved is transferred to the central area / space or court yard;
(e) The depth of such courtyard shall be at least 50% of the average building depth and the minimum width shall be 10m.
13. PARKING REQUIREMENTS:
(a) In all Buildings provision shall be made for parking spaces as per the following requirements:
TABLE – V
Sl. No.
Category of building/activity
Parking area to be provided as percentage of total built up area
Parking area to be provided as percentage of total built up area
Parking area to be provided as percentage of total built up area
Parking area to be provided as percentage of total built up area
Parking area to be provided as percentage of total built up area
Parking area to be provided as percentage of total built up area
Sl. No.
Category of building/activity
HMDA Area
HMDA Area
All Municipal Corporations & UDA Areas
All Municipal Corporations & UDA Areas
Municipalities/ N.Ps/ G.Ps. other than UDA Areas
Municipalities/ N.Ps/ G.Ps. other than UDA Areas
Sl. No.
Category of building/activity
GHMC
Municipali ties/N.Ps/G.Ps. in HMDA Area
All Munici pal Corpor ations
Municipal ities/N.Ps/ G.Ps. in UDA Areas
Selecti on & Special Grade Munici palities
Other Municipal ities/N.Ps/G.Ps.
1
2
3
4
5
6
7
8
1
Multiplexes
60
50
60
50
60
50
2
Shopping Malls (above 4000 sq.m), Information Technology Enabling Services Complexes
60
50
50
40
40
30
3
Hotels, Restaurants, Lodges, Cinema halls, Business buildings, Other Commercial buildings, Kalyana Mandapams, Offices, & High-Rise Buildings / Complexes of Non Residential Category
40
30
30
25
25
25
4
Residential Apartment Complexes, Hospitals, Institutional buildings, Industrial buildings, Schools, Colleges, Other Educational Buildings & Godowns & Others
30
20
20
20
20
20
(b) The parking spaces may be provided in
(i) Basements or cellars (one or more) / multi-level (allowed for plots 750sq.m and above only) or
(ii) Stilt floor or in upper floors (at any level) or
(iii) The Open space over and above the setbacks i.e. after leaving the setbacks to be left around the building with adequate vehicular access, aisle, drives, ramps required for maneuvering of vehicles, or
14. ENCOURAGEMENT FOR PROVISION OF PARKING COMPLEXES
To encourage parking complexes, Parking lots and enclaves, owners who develop parking complexes / parking lots, the following incentives would be considered:
(a) Equivalent built up area of such Parking Complex / or area of Parking lot as the case may be would be considered as Transferable Development Right by the Competent Authority.
(b) In an existing area/locality where an owner or two or more owners come together and develop combined or Common Parking Complex, Pedestrian Plaza / Subway, or improve / facilitate additional access by linking with surrounding roads etc for public usage are provided, as part of their premises / land development / improving the urban design aspects, additional bonus built up area / Transferable Development Right (TDR) would be considered by the sanctioning authority.
(c) The setbacks for Parking Complexes shall be as follows: front setback – as per building line in Table-III of rule-5. Setbacks on remaining sides – 50% of setbacks given in Table-III of rule-5.
(d) No fees and other charges shall be charged by the Sanctioning Authority for the area / floors developed as Parking Complex / Parking lot;
(e) A moratorium on property tax for 5 years would be considered;
(f) For the next 5 years – Property Tax shall be levied on the lowest slab of residential category.
(g) Such parking complexes may be permitted along main commercial roads, City Centers, close to Bus Stations, Railway Stations and any Public Transport System so as to encourage parking facility, etc. Access to these parking spaces in such Complexes may be accomplished through provision of mechanical lifts. Such areas may be identified by the sanctioning authority and notified to public every year.
15. COMPLIANCE OF NATIONAL BUILDING CODE PROVISIONS FOR AMENITIES AND FACILITIES IN ALL BUILDINGS
(a) Non High Rise Buildings
(i) The building requirements and standards other than heights and setbacks specified in the National Building Code - 2005 shall be complied with.
(ii) Such buildings shall be undertaken by owners by engaging registered architect, licenced builders / developers and licenced structural engineers. The designs and building plans shall be countersigned by the owner, licenced developer, registered architect, licenced engineer and a qualified & licenced Structural Engineer who shall be responsible for the supervision, structural safety, fire safety and specifications compliance of such buildings.
(iii) The work of the building services like sanitation, plumbing, fire safety requirements, lifts, electrical installations, and other utility services shall be executed under the planning, design and supervision of qualified and competent technical personnel.
(iv) The parking requirements shall comply as given in these rules. The parking facilities and vehicles driveways etc. shall be maintained to the satisfaction of the Sanctioning Authority.
(v) All Public and Semi-Public Buildings and Institutional Buildings shall be designed and constructed to provide facilities to the Specially Enabled Persons as prescribed in the National Building Code of India as given in Annexure – V.
(vi) In all Buildings, the requirements of parts of the building like size and area requirements of habitable rooms, kitchen, bathrooms and Water closets, other areas, corridor and staircase widths, service ducts, etc. shall conform to the National Building Code of India.
(vii) Rain Water Harvesting Structures shall be provided as given in G.O.Ms.No.350 MA, Dated. 09.06.2000 (Annexure-VI).
(viii) Provisions of the Andhra Pradesh Water, Land and Trees Act, 2002 shall be complied in such sites and schemes where ever applicable.
(ix) Buildings shall be designed for compliance with earth quake resistance and resisting other natural hazards. The Completion Certificate shall mention that the norms have been followed in the design and construction of buildings for making the buildings resistant to earthquake, compliance with structural safety and fire safety requirements.
(x) In case of Group Housing Buildings where there are 100 units and above, a minimum 3% of the total built up area shall be planned and developed for common amenities and facilities like convenient shopping, committee hall / club house, crèche, gymnasium etc. as per National Building Code of India (NBC)-2005. Amenities block shall not be part of the residential blocks. However in case of single apartment block, amenities can be provided in the same block.
(xi) In case of Group Housing Buildings where there are 100 units and above, buildings proposed for Nursing Homes, Hospitals and Hotels provision for Solar Water Heating System and Solar Lighting System in the building and in the site for outdoor lighting, etc. shall be made and the applicant shall give a bank guarantee to this effect to the sanctioning authority for compliance of the same.
OR
The owner shall be allowed to avail concessions in setbacks including the front set-back (subject to ensuring a building line of 6m in respect of roads 30m and above, 3m in respect of roads 18m and below 30m and 2m in respect of roads less than 18m and subject to ensuring minimum side and rear setback of 2m in case of building of height up to 12m and 2.5m in case of buildings of height above 12m and up to 15m and 3m for buildings of height above 15 and up to 18m).
(c) The extent of concessions given shall be such that the total built up area after concession shall not exceed the sum of built up area allowed (as proposed) on total area without road widening and built up area equivalent to surrendered area.
(d) In case of plots less than 750sq.m in addition to concessions in setbacks and height, the cellar floor may be allowed keeping in view of its feasibility on ground.
(e) In case of High Rise Buildings the concessions in setbacks, other than the front setback would be considered subject to maintaining minimum clear setback of 7m on the sides and rear side and such minimum setback area shall be clear without any obstructions to facilitate movement or fire fighting vehicles and effective firefighting operation.
(f) The above concessions shall be considered at the level of Sanctioning Authority / Competent Authority. The Sanctioning Authority / Competent Authority may consider any other concession as deemed fit with the prior approval of Government.
17. GRANT OF TRANSFERABLE DEVELOPMENT RIGHT:
(a) Transferable Development Right” (TDR) can be awarded only when such lands are transferred to the local body / Urban Development Authority as the case may be by way of registered gift deed. The award would be in the form of a TDR certificate issued by the Competent Authority / Sanctioning Authority.
(b) Grant of TDR can be considered by the Competent Authority / Sanctioning Authority for the following areas subject to the owners complying with the conditions of development above, as per the following norms:
(i) For the Master Plan Road / Road Development Plan undertaken and developed: equivalent to 200% of built up area of such area surrendered. For conservation and development of lakes / water bodies / nalas foreshores & Recreational buffer development with greenery, etc: equivalent to 100% of built up area of such recreational buffer area developed at his cost.
(ii) For Heritage buildings and heritage precincts maintained with adaptive reuse: equivalent to 100% of built up area of such site area.
(c) The TDR may be arrived at on the basis of relative land value and equivalent amount in both export and Import areas, as per the Registration Department records. The Competent Authority shall have the discretion in the matter of applicability of TDR. The TDR shall not be allowed in unauthorized buildings / structures / constructions and shall be considered only after the land is vested with the local authority / UDA. The TDR certificate issued would be valid or utilized / disposed only within the concerned local body area and as per guidelines and conditions prescribed.
(e) Documents Required with Application for Grant of Transferrable Development Right Certificate:
Application to be made by owner in the prescribed format giving the following details:
(i) Name of the owner with clear address, contact phone number, etc.
(ii) Copy of the ownership documents along with clear site plan and location plan.
(iii) Site Plan showing the land surrendered, its extent, location with dimensions.
(iv) Building permission Plan for the site by the urban local body.
(v) Details of Building permission granted / applied for like use or purpose of building, number of floors permitted, all-round setbacks, floor area permitted and utilized, parking area permitted; etc.
(vi) Whether already benefit of relaxations been utilized for the site?
(vii) Whether any Court case is pending against Urban Local Body?
(viii) Land value of the site where TDR is to be availed (latest copy from concerned Sub Registrar to be enclosed)
(ix) TDR admissible in terms of sq.m and equivalent land value.
18. URBAN DESIGN AND ARCHITECTURAL CONTROL
For certain areas as well as sites abutting major roads of 30m and above, the Competent Authority may enforce urban design and architectural control. These shall be detailed out keeping in view the development conditionalities and requirements given in these Regulations and the National Building Code norms. For this purpose, urban design and architectural control sheets / Plans approved by the Competent Authority shall be complied with.
19. BUILDING PERMIT / LICENSE FEES
(a) The Sanctioning Authority shall along with the Building Application levy and collect 2% of the Building Permit / License fees, subject to a maximum of Rs.10,000 as initial fees. The balance Building Permit / License Fees together with other fees and Charges shall be levied and collected before the issue of permission / sanction.
(b) In case of rejection of building application, the above initial fees would be forfeited.
(c) No fees and charges would be levied for parking spaces provided in any floor.
(d) The permission is valid for 5years in case of High Rise Buildings & Group Development Schemes and 3years in case of Non High Rise Buildings subject to condition that the construction shall be commenced with in 18months. The permission can be revalidated for another 2years on payment of building permit fee.
(b) Areas not covered under HMDA / UDA Areas:
(i) Where the Town Planning Section Head is below the cadre of Deputy Director, the Sanctioning Authority is empowered to sanction the building permission up to 10m height in plot area up to 300sq.m, in the sites where the proposed activity is permissible in normal course as per Zoning Regulations.
If the site area is above 300sq.m and up to 1000sq.m. prior Technical Approval from the concerned Regional Deputy Director shall be obtained where the proposed activity is permissible in normal course as per Zoning Regulations.
(ii) Where the Town Planning Section Head is in the cadre of Deputy Director or above, the Sanctioning Authority is empowered to sanction the building permission in plot area up to 1000sq.m, in the sites where the proposed activity is permissible in normal course as per Zoning Regulations.
(iii) Other than (i) & (ii) above the proposals of building approvals shall be submitted to The Director of Town and Country Planning for prior Technical Approval.
(iv) In the Gram Panchayat areas covered under sanctioned General Town Planning (GTP) Scheme the Sanctioning Authority is empowered to sanction the individual residential building permission up to 10m height in plot area up to 300sq.m, in the sites where the proposed activity are permissible in normal course as per Zoning Regulations. In respect of other cases prior Technical Approval shall be obtained from the Competent Authority i.e. Director of Town & Country Planning.
(v) In Case of Group Development, Group Housing Schemes like Cluster Housing / Row Housing / Semidetached Housing Schemes and Gated Community, Technical approval from the Competent Authority is required to be obtained.
24. HIGH RISE BUILDING COMMITTEE
The following committees shall be constituted for scrutiny of High Rise Building applications.
(a) Greater Hyderabad Municipal Corporation (GHMC)/Greater Visakhapatnam Municipal Corporation (GVMC)/Vijayawada Municipal Corporation (VMC).
Chief City Planner / Town Planning Section Head : Member Convener
Engineering Section Head : Member
Director of Town & Country Planning (DT&CP) or : Member his nominee
Town Planning Section Head of Urban : Member Development Authority (UDA) or his nominee
The Committee shall give the recommendations to the Commissioner.
(iv) Common pool parking area (in the case of Group Housing Scheme / Cluster Housing / Row Housing Schemes).
(v) Any of the above or all the above or combination of the above.
(vi) Wherever Mechanical system and car lifts are proposed enabling two tier parking, the required parking is computed accordingly.
(c) The other aspects for providing parking spaces are:
(i) Misuse of the area specified for parking of vehicles for any other use shall be summarily demolished / removed by the Enforcement Authority.
(ii) The parking spaces should be efficiently designed and clearly marked and provided with adequate access, aisle, drives and ramps required for maneuvering of vehicles.
(iii) Cellar floor shall be used only for parking and not for any habitation purpose. There shall be ventilation to cellars with not less than 2.5% of each cellar floor area.
(iv) In respect of Apartment Complexes / Building / Block of residential nature, in sites up to 750sq.m the Parking requirement shall be deemed to be met if the entire stilt floor is left for parking.
(v) Common and Continuous cellar parking floors between adjoining buildings would be allowed depending upon structural safety aspects, mutual agreement between owners, etc.
(vi) In the Stilt floor a watchman room and 2 toilets (W.C), with maximum built up area of 25sq.m may be allowed. Such space shall not be disposed and shall be part of common facility of the complex. For the sites above 750sq.m area it is permitted subject to fulfillment of parking requirement as per Table-V.
(vii) For parking spaces in basements and upper floors, at least two ramps of minimum 3.6m width or one ramp of minimum 5.4m width and adequate slope 1 in 8 shall be provided. Such ramps shall not be allowed in mandatory setbacks including building line, however they may be permitted in the side and rear setbacks after leaving minimum 7m of setback for movement of fire-fighting vehicles. Access to these may also be accomplished through provisions of mechanical lifts.
(viii) The minimum width of the drive way shall be 4.5m.
(ix) In case where the permissible set back is less than 4.6m the pillars position in stilt floor shall be so designed that there shall be clear space of 3.6m (excluding Greenery) is available for movement of vehicles.
(x) Cellar shall be with a setback of at least 1.5m in the sites of extent of up to 1000sq.m, 2m in the sites of extent of more than 1000sq.m and up to 2000sq.m, and 3m in the sites of extent of more than 2000sq.m from the property line. In case of more than one cellar, 0.5m additional setback for every additional cellar floor shall be insisted.
(xi) Up to 10% of cellar may be utilised for utilities and non-habitation purpose like A/C Plant room, Generator room, Sewerage Treatment Plant (STP), Electrical installations, Laundry, etc,
(xii) Visitors’ parking shall be provided with minimum 10% of the parking area mentioned in Table-V and may be accommodated in the mandatory setbacks other than front setback where ever such setbacks are more than 6m (excluding green strip).How ever this is not permissible in case of transfer of setback. The Visitors’ Parking facility shall be open to all visitors which shall be properly demarcated on ground.
(xii) In case of Group Housing Buildings where there are 100 units and above, Nursing Homes, Hospitals and Hotels provision for Recycling of Water shall be made.
20. LEVY OF SPECIAL FEES AND OTHER PROVISIONS FOR CERTAIN AREAS:
The Sanctioning Authority with the specific approval of the Government may, when implementing such Projects, levy Special fees and other fees / charges for lands / sites / premises abutting or in the vicinity of the Ring Road or other highways / major roads or the Mass Rail Transit System / Light Rail Transit System / Multi Modal Transit System / Bus Rapid Transit System route indicated in the Master Plan, at the rates and procedure prescribed by the Government.
21. CITY LEVEL INFRASTRUCTURE IMPACT FEES APPLICABLE IN CERTAIN CASES:
(a) With a view to ensure development of City Level Infrastructure facilities and the City Level Infrastructure Impact Fees shall be levied as given in the table below:
TABLE – VI
Areas
Height (No. of Floors), Use of the Building and Rate in Rs. per sq. m of Built Up Area
(b) For The first 15m height of the building (excluding stilt floor) there will be no levy of City Level Impact Fee.
(c) In case of Multiplexes the rates given in the Multiplex Rules shall be applicable.
(d) The Government may revise the above rates from time to time.
(e) The above rates shall not be applicable for Government Departments and Public Agencies like Urban Development Authority, Andhra Pradesh Industrial Infrastructure Corporation (APIIC), Local Bodies and Hyderabad Metropolitan Water Supply & Sewerage Board (HMWSSB). This exemption shall not be applicable for commercial projects taken up by such agencies.
(f) The amount levied and collected under the above Rule shall be credited and maintained in a separate escrow account by the concerned sanctioning authority and 50% of it shall be utilised for development of infrastructure in the same area and balance amount is to be utilised towards improvement of city level capital infrastructure in the area. An Infrastructure Plan and Action Plan for implementation is required to be undertaken by the Competent Authority and the said Fund is utilised accordingly.
22. INCENTIVES FOR OWNERS LEAVING MORE SETBACKS / INSTALLING SOLAR HEATING SYSTEM / LIGHTING / RAIN WATER HARVESTING / RECYCLING OF WASTE WATER:
The following incentives in terms of rebate in Property Tax will be given by the local authority for owners or their successors-in-interest who:
(i) Install and use solar heating and lighting system: 10% rebate.
(ii) Undertake both recycling of waste water and rain water harvesting structures: 10% rebate.
23. TECHNICAL APPROVAL FROM THE COMPETENT AUTHORITY
(a) Hyderabad Metropolitan Development Authority (HMDA) / Urban Development Authority (UDA) Areas: In case of areas falling under the jurisdiction of HMDA / UDA, the development control powers shall be as per the delegation issued by the concerned HMDA / UDA from time to time.
(b) Hyderabad Metropolitan Development Authority (HMDA)/All Urban Development Authorities (UDA) (Other than the area covered in “a” above.)
Head of the Town Planning wing of concerned UDA -Member
Town Planning Section Head or his nominee of concerned ULB-Member
Engineering Section Head of concerned UDA / ULB -Member
Director of Town & Country Planning or his nominee. -Member
The Committee shall give the recommendations to the Metropolitan Commissioner / Vice Chairman.
(c) Other Municipal Corporations / Municipalities / Nagar Panchayats.
(Other than the area covered in (a) & (b) above i.e. DT&CP Jurisdiction)
Commissioner of concerned ULB -Member
Regional Deputy Director of Town Planning -Member
Superintendent Engineer Public Health -Member
Town Planning Section Head of concerned ULB -Member Convener
Senior Practicing Architect / Planner nominated by DT&CP -Member
The Committee shall give the recommendations to the Director of Town & Country Planning.
(d) Gram Panchayats covered in Sanctioned Master Plan Area.
(Other than the area covered in (a), (b) & (c) above i.e. DT&CP Jurisdiction)
Regional Deputy Director of Town Planning (RDDTP) -Member Convener 2. Superintendent Engineer Public Health -Member
Senior Practicing Architect / Planner nominated by DT&CP -Member
The Panchayat Secretary shall submit the proposal through the concerned Regional Deputy Director of Town Planning (RDDTP) to place before the committee and the committee shall give the recommendations to the Director of Town & Country Planning.
The guidelines for Nomination of Senior Practicing Architect / Planner shall be followed as mentioned in Annexure - XII.
25. COMPLIANCE BY OWNER FOR ENSURING CONSTRUCTION IS UNDERTAKEN AS PER SANCTIONED PLAN:
(a) The owner and builder / developer shall give an Affidavit duly notarized to the effect that in the case of any violation from the sanctioned building plan, the Enforcement Authority can summarily demolish the violated portion.
(b) In respect of Apartment Buildings, the owner or builder shall give a Declaration duly specifying the number of floors permitted, along with the extent of each floor. In case of any violation with regard to the Declaration, the Enforcement Authority can demolish the violations.
(c) Before release of the building sanction by the sanctioning authority, the owner of the plot / site is not only required to produce the original Sale Deed, registered under the provisions of the Indian Registration Act, 1908 / Certified copy issued by Stamps and Registration Department for the perusal of the sanctioning authority and cross verification with the attested copy submitted with the building application.
(d) The owner is required to hand over 10% of the built-up area in the ground floor or first floor or the second floor, as the case may be, to the sanctioning authority by way of a Notarised Affidavit. In respect of row houses / detached houses / cluster housing 5% of the units shall be handed over by way of notarized affidavit to the sanctioning authority. The Notarised Affidavit shall be got entered by the sanctioning authority in the Prohibitory Property Watch Register of the Registration Department. Then only the Building sanction will be released.
(e) Individual buildings in plots up to 200sq.m with height up to 7m in respect of Municipal Corporations including Greater Hyderabad Municipal Corporation (GHMC) and 300sq.m with height up to 7m in respect of Municipalities / Nagar Panchyats are exempted from the conditions (c) & (d) above.
26. OCCUPANCY CERTIFICATE:
(a) Occupancy Certificate shall be mandatory for all buildings. No person shall occupy or allow any other person to occupy any building or part of a building for any purpose unless such building has been granted an Occupancy Certificate by the Sanctioning Authority. Partial Occupancy Certificate may be considered by the Sanctioning authority on merits i.e. flats / units or area within a complex which have fulfilled all the requirements in addition to basic facilities like lifts water supply, sanitation, drainage, roads, common lighting etc. However, in respect of individual buildings in plots up to 100sq.m with height up to 7m obtaining Occupancy Certificate is optional.
(b) The owner shall submit a notice of completion through the registered architect and licenced builder / developer along with prescribed documents and plans to the Sanctioning Authority. The Sanctioning Authority or the person authorized, on receipt of such notice of completion shall undertake inspection with regard to the following aspects:
(i) *No. of Floors.
(ii) External setbacks.
(iii) Usage of the building.
(iv) Parking space provision.
(v) Abutting road width
* The total height of the building may vary to a maximum of 1m with no change in the permitted number of floors subject to compliance of fire service norms.
(c) The Sanctioning Authority shall communicate the approval or refusal of the Occupancy Certificate within 15days or may issue the same after levying and collecting compounding fee, if any. If the authority fails to issue the occupancy certificate within the above stipulated period the responsibility shall be fixed with the concerned officer who fails to process the file.
(d) The Sanctioning Authority is empowered to compound the offence in relation to setbacks violations (other than the front setback) in respect of non high rise buildings only up to 10%, duly recording thereon the violations in writing. The rate of Compounding fee shall be equivalent to one hundred percent of the value of the land as fixed by the Registration Department at the time of compounding for the violated portion and the Government may revise this rate from time to time. Compounding of such violation shall not be considered for buildings constructed without obtaining any sanctioned plan.
(e) For all high rise buildings, the work shall be subject to inspection by the Andhra Pradesh State Disasters Response & Fire Services Department and the Occupancy Certificate shall be issued only after clearance from the Andhra Pradesh State Disasters Response & Fire Services Department with regard to Fire Safety and Protection requirements.
(f) The sanctioning authority shall ensure that all public and semi public buildings are constructed disable friendly and provide facilities for specially enabled persons as per National Building Code -2005 of India while issuing occupancy certificate.
(g) The functional/line agencies dealing with electric power, water supply, drainage and sewerage shall not give regular connections to the building unless such Occupancy Certificate is produced, or alternatively may
charge 3 times the tariff till such time Occupancy Certificate is produced. This condition shall also be applicable to all unauthorized constructions and buildings constructed without sanctioned building plan. In addition to the above, the Local Body shall collect every year two times the property tax as penalty from the owner / occupier.
(h) The Registration Authority shall register only the permitted built up area as per the sanctioned building plan and only upon producing and filing a copy of such sanctioned building plan. On the Registration Document it should be clearly mentioned that the registration is in accordance with the sanctioned building plan in respect of setbacks and number of floors.
(i) The financial agencies / institutions shall extend loan facilities only to the permitted built up area as per the sanctioned building plan.
27. ENFORCEMENT
(a) In addition to the enforcement powers and responsibilities given in the respective laws of the local authority, in respect of these Rules:
(i) The Enforcement Authority concerned shall be wholly and severally responsible for ensuring and maintaining the right of way / width of the road and building restrictions as given in these Rules.
(ii) The Enforcement Authority shall summarily remove any violation or deviation in building construction in maintaining the road widths and building line.
(iii) In respect of apartment complexes, shopping complexes and all high rise buildings, periodical inspections shall be carried out indicating the stage of work with reference to sanctioned plan. In case of any deviations from the sanctioned plan, necessary action shall be taken as per rules.
(iv) Any person who whether at his own instance or at the instance of any other person or anybody including the Government Department undertakes or carries out construction or development of any and in contravention of the statutory master plan or without permission, approval or sanction or in contravention of any condition subject to which such permission or approval or sanction has been granted shall be punished with imprisonment for a term which may extend to three years, or with fine which may extend to ten percent of the value of land or building including land in question as fixed by the Registration Department at the time of using the land or building. Provided that the fine imposed shall, in no case be less than fifty percent of the said amount.
(b) Constitution of Town Planning and Building Tribunal:
The Government shall constitute a Town Planning and Building Tribunal for dealing with all town planning, enforcement and building issues by making necessary amendments to the corresponding Acts if required.