(b) High Rise Buildings: in addition to the above the following conditions shall also be complied with
(i)In addition to the required staircases and lifts, there shall be at least one fire escape staircase and lift. These staircases and lifts shall be got certified from the manufacturer’s authorized service technical personnel from time to time.
(ii) Such buildings shall be undertaken by owners by engaging registered architect, licenced builders / developers and licenced structural engineers. The designs and building plans shall be countersigned by the owner, licenced developer, registered architect, licenced engineer and a qualified & licenced Structural Engineer who shall be responsible for the supervision, structural safety, fire safety and specifications compliance of such buildings.
(iii) Provision for power generator shall be made.
(iv) These buildings shall be planned, designed and constructed to ensure fire safety requirements are met and maintained and shall comply in accordance with the Fire Protection Requirements of National Building Code of India (NBC)-2005 / Andhra Pradesh Fire Services Act,1999.
(v) The facilities for providing fire protection and firefighting facilities in such buildings should be in compliance with the stipulations laid down and clearance issued by the Andhra Pradesh State Disasters Response & Fire Services Department from time to time. No Objection Certificate (NOC) from the Andhra Pradesh State Disasters Response & Fire Services Department shall be obtained from time to time regarding the fire safety requirements and facilities installed. The designs and installations regarding fire protection and safety measures including exit requirements and smoke containment and smoke management measures shall be undertaken through a fire engineer / fire consultant.
(vi) Buildings shall be designed for compliance with earth quake resistance and resisting other natural hazards. The Completion Certificate shall mention that the norms have been followed in the design and construction of buildings for making the buildings resistant to earthquake, compliance with structural safety and fire safety requirements.
16. CONCESSIONS IN ROAD WIDENING CASES:
(a) Where any land or site or premises for building is affected in the Statutory Plan / Master Plan Road or Circulation network or a road required to be widened as per Road Development Plan, such area so affected in the road or circulation network shall be surrendered free of cost to the Sanctioning Authority by the owner of land. No development permission shall be given unless this condition is complied with.
(b) Upon surrendering such affected area the owner of the site would be entitled to a Transferable Development Right (TDR) as given in Rule-17. OR
The owner shall be allowed to construct an extra floor with an equivalent built area for the area surrendered subject to mandated public safety requirements.
Chapter 7Requirements for High Rise Buildings:
(a) High Rise Buildings / Complexes
(i) High Rise Buildings / Complexes shall be permissible only in areas other than those given in Annexure - I & II.
(ii) The minimum size of plot for High Rise building shall be 2000sq.m.
(iii) In respect of sites proposed for high rise buildings and affected in road widening where there is shortfall of the net plot size, up to 10% of such shortfall in net plot area would be considered with the proposed height and corresponding minimum all round setbacks.
(iv) Every application to construct or reconstruct a High Rise building or alteration to existing High Rise building shall be made in the prescribed form and accompanied by detailed plans, floor plans of all floors along with complete set of structural drawings and detailed specifications duly certified by a qualified licenced structural engineer.
(v) Prior Clearance from Airport Authority:
For any High Rise Building located in the vicinity of airports as given in the National Building Code, the maximum height of such building shall be decided in consultation with the Airport Authority and shall be regulated by their rules / requirements.
(vi) Prior No Objection Certificate (NOC) from the Andhra Pradesh State Disasters Response & Fire Services Department:
For all High Rise Buildings prior No objection Certificate (NOC) from the Andhra Pradesh State Disasters Response & Fire Services Department shall be obtained and copy of the approved plan and No Objection Certificate (NOC) issued by the said department shall be enclosed along with the building application.
(vii) In every high rise building site, an organized open space shall be utilized as greenery, tot lot or soft landscaping, etc. shall be provided over and above the mandatory setbacks to be left in and around the building. This space shall be at least 10% of total site area at ground level open to sky and shall be a minimum width of 3m. This may be in one or more pockets with minimum area of 50sq.m at each location.
(viii) In addition to the above, a minimum of 2m wide green planting strip in the periphery on all sides within the setbacks are required to be developed and maintained.
(ix) Buildings abutting major road of 30m and above width shall be permitted only after providing black-topped service roads of minimum 7m width with minimum 2 Lane carriageway with in the defined right of way. It will be the responsibility of the developer / builder / owner to provide the above service road of the standards fixed by the Sanctioning Authority at his own cost. The Sanctioning Authority may consider sanctioning building permission if the developer / builder / owner deposits the full cost for laying such service road to the Sanctioning Authority. The amount so levied and collected shall be maintained in a separate exclusive account by the Sanctioning Authority and utilized only for this purpose.
(x) The minimum abutting road width and all round open space / setback for High Rise Building / Complex shall be as follows:
TABLE – IV
Height of building (in meters)
Minimum abutting road width required (in meters)
Minimum all-round open space on remaining sides (in meters) *
above
Up to
1
2
3
4
-
21
12
7
21
24
12
8
24
27
18
9
27
30
18
10
30
35
24
11
35
40
24
12
40
45
24
13
45
50
30
14
50
55
30
16
After 55m 0.5m additional setback for every 5m of height shall be insisted
(xi) * The front open space shall be on the basis of the abutting road width and shall be either as given in Col. 4 of above Table - IV or the Building Line given in Table - III of rule-5 whichever is higher.
(xii) The open space to be left between two blocks shall be equivalent to the open space mentioned in Col. 4 of above Table – IV and this shall not be considered for organized open space (Tot lot).
(xiii) In case of high rise buildings up to 30m height, it is permitted to transfer up to 2m of setback from one side to the other side, which needs to be uniform at any given point, subject to maintaining of minimum setback of 7m on all sides subject to not exceeding the permissible / allowable plinth area.
(xiv)The balcony projection of up to 2m may be allowed projecting onto the open spaces for upper floors from 6m height onwards.
(xv) Where the lighting and ventilation of a building is through the means of a chowk or inner courtyard or interior open space/duct, such open space shall be open to sky and area of at least 25sq.m and no side shall be less than 3m.
(b) Tower and Podium Type Building:
(i) Height of the building shall be allowed up to 50m.
(ii) For Podium, i.e., Ground plus first floor: alround setbacks shall be 7m.
(iii) For Tower block: The coverage and alround setbacks shall be minimum 50 % of the Podium Block, and shall be atleast 3m from the Podium edge on all sides,
(iv) The fire safety and fire escape measures for the Tower Block shall be independent of the Podium Block.
(c) “Stepped Type” or “Pyramidal Type” Building:
Such type of High Rise Building blocks may be allowed for heights above 30m with the following open space requirements:
(i) At Ground level: Minimum 9m all round open space for the first five floors.
(ii) At Upper floors: Increase of 1m all round open space or more, for every 5 upper floors or 15m height or part thereof, over and above the ground level open space of minimum 9m.
(d) Multiplex Complexes:
In case of Multiplex Complexes, “The Andhra Pradesh Rules for Construction and Regulation of Multiplex Complexes, 2007” issued vide G.O.Ms.No. 486, Dt.07.07.2007 shall be followed (Annexure-III).
(e) Hospital Buildings with more than 30m height
In case of Hospital Buildings with more than 30m height, “The Andhra Pradesh Fire Prevention and Safety measures in High Rise Hospital Buildings (above 30m height) Rules 2011” issued vide G.O.Ms.No.2, Dt.03.01.2011 shall be followed (Annexure-IV).
8. GROUP DEVELOPMENT SCHEMES:
(a) The minimum site / plot area shall be 4000sq.m.
(b) The minimum abutting existing road width shall be 12m and black topped.
(c) If the site is not abutting to an existing road, the proposals should be promoted with the immediate improvement of the accessibility of the site from the nearest main road by way of an approved Road Development Plan by the Competent Authority with a minimum width of 12m which
should be implemented by the Licenced Developer within a period of three years.
(d) Group Development Schemes shall be considered where the site is developed together with construction of building and all amenities and facilities and not disposed as open plots.
(e) All such applications shall in addition to the requirements under these Rules be accompanied by the provisional plans of.
(i) A Services and Utilities Plan as per standards for water supply system, drainage and storm water disposal system, sewerage system, rain water harvesting structures, and for other utilities.
(ii) A Landscaping plan including rain water harvesting / water recycling details.
(iii) Parking & Internal Circulation Plan along with common pool parking area plan, if any.
(f) The above shall be drawn to suitable scale with relevant details.
(g) Minimum of 10% of site area shall be earmarked for organised open space and be utilised as greenery, tot lot or soft landscaping, etc. and shall be provided over and above the mandatory setbacks. Such open space shall be open to sky with a minimum width of 3m. This may be in one or more pockets with minimum area of 50sq.m at each location.
(h) No additional or proportionate open space charges need to be levied in such schemes.
(i) These shall not be applicable in case of Government sponsored Housing Scheme / approved Non Government Organisations (NGOs) or private schemes, and the guidelines and requirements as given in the National Building Code for Low Cost Housing / Government orders shall be followed.
(j) The Building setbacks shall be as per the type of housing & requirements given above for the said type of housing and as per Table - III of rule-5 and Table – IV of rule-7. The open space to be left between two blocks also shall be equivalent to the setback mentioned in Column -10 of Table-III of rule-5 and Column - 4 of Table- IV of rule-7 as the case may be.
(k) A thorough public access road of 12m width with 2-lane black-topped is to be developed within the applicant’s site on any one side at the periphery / as per suitability and feasibility for the convenience of accessibility of other sites and lands located in the interior. This condition would not apply if there is an existing abutting peripheral road on any side.
(l) In case of blocks up to 12m height, access through pathways of 6m width branching out from the internal roads / loop road would be allowed. All internal roads and pathways shall be developed with good design, practices, good built environment and standards.
(m)Road requirements:
9m to 18m for main internal approach roads;
9m for other internal roads and also for looped roads.
8m for cul-de-sacs roads (with a minimum radius 9m.) between 50-100m length.
(n) All roads and open spaces mentioned in this Rule shall be handed over to local body at free of cost through a registered gift deed before issue of occupancy certificate. The society / association may in turn enter into agreement with the local authority for utilizing, managing and maintaining the roads and open spaces. In case of any violation or encroachment, the local authority shall summarily demolish the
encroachments and resume back the roads and open spaces and keep it under its custody.
9. ROW TYPE HOUSING / ROW TYPE SHOPPING PRECINCTS:
(a) Row Houses shall abut internal roads only.
(b) Minimum site area shall be not less than 1000sq.m.
(c) Minimum size of individual plot shall be 50sq.m.
(d) Maximum plot size shall be 125sq.m.
(e) Number of plots in a row shall not be more than 8.
(f) Separation between two blocks shall not be less than 6 m which may be an open space or an alley/pedestrian plaza.
(g) Only internal staircase is allowed.
(h) Minimum width of internal roads: 9m.
(i) Internal cul-de-sac road 6m with maximum length 50m is allowed.
(j) Minimum open space : 10 % of site area.
(k) Height permissible:
i. Ground + 1 floor or 7m in plot area up to 100sq.m.
ii. Ground + 2 floors or 10m in plot area of above 100sq.m.
(l) Minimum setbacks: Front 3m ; Rear 1.5m.
(m) The setbacks in a row can be interchangeable.
(n) In case of row type shopping precincts, back to back shops with above front setback of 3m would be allowed.
(o) In case of very large projects more than 5 acres, common amenities and facilities like shopping center, community hall/club house etc. are required to be provided in minimum 5 % of the site area.
(p) In case of Row Type Shopping Precincts, common basement parking in one or more levels would be permissible subject to conditions mentioned in Rule -13.
10. CLUSTER HOUSING
(a) Minimum site area shall be not less than 1000sq.m.
(b) Minimum plot size 25sq.m with maximum number of 20 houses in a cluster.
(c) Minimum size of cluster open space 36sq.m with a minimum width of 6m.
(d) Height permissible 2 floors or 6m.
(e) Minimum access road 9m.
(f) Internal access may be through pedestrian paths of 6m.
(g) Minimum space between two clusters shall be 6m which may be utilised as pathway / alley.
(h) Building setbacks: No setbacks are needed for interior clusters as the lighting and ventilation is either from the central open space of cluster and the surrounding pedestrian pathway / access road of the cluster. However, interior courtyards may be provided for larger plots and building areas to facilitate lighting and ventilation. For end clusters sides that are abutting peripheral thoroughfare roads or property boundary, setback / building line shall be as per Table – III of rule-5.
(i) In case of very large projects more than 5 acres, common amenities and facilities like shopping center, community hall/club house etc. are required to be provided in minimum 5 % of the site area.
11. PROVISIONS FOR ECONOMICALLY WEAKER SECTION (EWS) / LOW INCOME GROUP (LIG) HOUSING CATEGORY
(a) In case of areas falling in Hyderabad Metropolitan Development Authority (HMDA), Visakhapatnam Urban Development Authority (VUDA), Vijayawada–Guntur–Tenali–Mangalagiri Urban Development Authority
(VGTMUDA) where the proposed site area for residential projects is 4000sq.m and above, the developer shall provide at least 20% of developed land for Economically Weaker Sections (EWS) and Low Income Groups (LIG) housing in such projects.
(b) In case of areas falling in Municipal Corporations and the Urban Development Authorities in the State except Greater Hyderabad Municipal Corporation, Greater Visakhapatnam Municipal Corporation, Vijayawada Municipal Corporation, Guntur Municipal Corporation, HMDA, VUDA, VGTMUDA areas where the proposed site area for residential projects is 3000sq.m and above, the developer shall provide at least 20% of developed land for Economically Weaker Sections (EWS) and Low Income Groups (LIG) housing in such projects.
(c) In case of areas falling in Municipalities / Nagar Panchayats constituted under the provisions of the Andhra Pradesh Municipalities Act, 1965 and excluding the Municipalities which are within the jurisdiction of any Urban Development Authority where the proposed site area for residential projects is 2000sq.m and above, the developer shall provide at least 20% of developed land for Economically Weaker Sections (EWS) and Low Income Groups (LIG) housing in such projects.
12. BUILDINGS WITH CENTRAL COURTYARD FOR COMMERCIAL USE:
(a) ‘U’ type commercial buildings with central courtyard are allowed with a minimum plot area of 2000sq.m with the following conditions:
(b) The Front setback shall be as per Table-III of rule-5 & Table-IV of rule-7 for Non High Rise & High Rise buildings respectively.
(c) The minimum open space / setback on sides and rear except front, shall be
(i) 2m for building height up to 15m;
(ii) 3m for building height up to 18m;
(iii) 7m in case of high rise buildings up to 30m height and buildings coming under purview of Andhra Pradesh Fire Services Act-1999.
(d) The area so saved is transferred to the central area / space or court yard;
(e) The depth of such courtyard shall be at least 50% of the average building depth and the minimum width shall be 10m.
13. PARKING REQUIREMENTS:
(a) In all Buildings provision shall be made for parking spaces as per the following requirements:
TABLE – V
Sl. No.
Category of building/activity
Parking area to be provided as percentage of total built up area
Parking area to be provided as percentage of total built up area
Parking area to be provided as percentage of total built up area
Parking area to be provided as percentage of total built up area
Parking area to be provided as percentage of total built up area
Parking area to be provided as percentage of total built up area
Sl. No.
Category of building/activity
HMDA Area
HMDA Area
All Municipal Corporations & UDA Areas
All Municipal Corporations & UDA Areas
Municipalities/ N.Ps/ G.Ps. other than UDA Areas
Municipalities/ N.Ps/ G.Ps. other than UDA Areas
Sl. No.
Category of building/activity
GHMC
Municipali ties/N.Ps/G.Ps. in HMDA Area
All Munici pal Corpor ations
Municipal ities/N.Ps/ G.Ps. in UDA Areas
Selecti on & Special Grade Munici palities
Other Municipal ities/N.Ps/G.Ps.
1
2
3
4
5
6
7
8
1
Multiplexes
60
50
60
50
60
50
2
Shopping Malls (above 4000 sq.m), Information Technology Enabling Services Complexes
60
50
50
40
40
30
3
Hotels, Restaurants, Lodges, Cinema halls, Business buildings, Other Commercial buildings, Kalyana Mandapams, Offices, & High-Rise Buildings / Complexes of Non Residential Category
40
30
30
25
25
25
4
Residential Apartment Complexes, Hospitals, Institutional buildings, Industrial buildings, Schools, Colleges, Other Educational Buildings & Godowns & Others
30
20
20
20
20
20
(b) The parking spaces may be provided in
(i) Basements or cellars (one or more) / multi-level (allowed for plots 750sq.m and above only) or
(ii) Stilt floor or in upper floors (at any level) or
(iii) The Open space over and above the setbacks i.e. after leaving the setbacks to be left around the building with adequate vehicular access, aisle, drives, ramps required for maneuvering of vehicles, or
14. ENCOURAGEMENT FOR PROVISION OF PARKING COMPLEXES
To encourage parking complexes, Parking lots and enclaves, owners who develop parking complexes / parking lots, the following incentives would be considered:
(a) Equivalent built up area of such Parking Complex / or area of Parking lot as the case may be would be considered as Transferable Development Right by the Competent Authority.
(b) In an existing area/locality where an owner or two or more owners come together and develop combined or Common Parking Complex, Pedestrian Plaza / Subway, or improve / facilitate additional access by linking with surrounding roads etc for public usage are provided, as part of their premises / land development / improving the urban design aspects, additional bonus built up area / Transferable Development Right (TDR) would be considered by the sanctioning authority.
(c) The setbacks for Parking Complexes shall be as follows: front setback – as per building line in Table-III of rule-5. Setbacks on remaining sides – 50% of setbacks given in Table-III of rule-5.
(d) No fees and other charges shall be charged by the Sanctioning Authority for the area / floors developed as Parking Complex / Parking lot;
(e) A moratorium on property tax for 5 years would be considered;
(f) For the next 5 years – Property Tax shall be levied on the lowest slab of residential category.
(g) Such parking complexes may be permitted along main commercial roads, City Centers, close to Bus Stations, Railway Stations and any Public Transport System so as to encourage parking facility, etc. Access to these parking spaces in such Complexes may be accomplished through provision of mechanical lifts. Such areas may be identified by the sanctioning authority and notified to public every year.
15. COMPLIANCE OF NATIONAL BUILDING CODE PROVISIONS FOR AMENITIES AND FACILITIES IN ALL BUILDINGS
(a) Non High Rise Buildings
(i) The building requirements and standards other than heights and setbacks specified in the National Building Code - 2005 shall be complied with.
(ii) Such buildings shall be undertaken by owners by engaging registered architect, licenced builders / developers and licenced structural engineers. The designs and building plans shall be countersigned by the owner, licenced developer, registered architect, licenced engineer and a qualified & licenced Structural Engineer who shall be responsible for the supervision, structural safety, fire safety and specifications compliance of such buildings.
(iii) The work of the building services like sanitation, plumbing, fire safety requirements, lifts, electrical installations, and other utility services shall be executed under the planning, design and supervision of qualified and competent technical personnel.
(iv) The parking requirements shall comply as given in these rules. The parking facilities and vehicles driveways etc. shall be maintained to the satisfaction of the Sanctioning Authority.
(v) All Public and Semi-Public Buildings and Institutional Buildings shall be designed and constructed to provide facilities to the Specially Enabled Persons as prescribed in the National Building Code of India as given in Annexure – V.
(vi) In all Buildings, the requirements of parts of the building like size and area requirements of habitable rooms, kitchen, bathrooms and Water closets, other areas, corridor and staircase widths, service ducts, etc. shall conform to the National Building Code of India.
(vii) Rain Water Harvesting Structures shall be provided as given in G.O.Ms.No.350 MA, Dated. 09.06.2000 (Annexure-VI).
(viii) Provisions of the Andhra Pradesh Water, Land and Trees Act, 2002 shall be complied in such sites and schemes where ever applicable.
(ix) Buildings shall be designed for compliance with earth quake resistance and resisting other natural hazards. The Completion Certificate shall mention that the norms have been followed in the design and construction of buildings for making the buildings resistant to earthquake, compliance with structural safety and fire safety requirements.
(x) In case of Group Housing Buildings where there are 100 units and above, a minimum 3% of the total built up area shall be planned and developed for common amenities and facilities like convenient shopping, committee hall / club house, crèche, gymnasium etc. as per National Building Code of India (NBC)-2005. Amenities block shall not be part of the residential blocks. However in case of single apartment block, amenities can be provided in the same block.
(xi) In case of Group Housing Buildings where there are 100 units and above, buildings proposed for Nursing Homes, Hospitals and Hotels provision for Solar Water Heating System and Solar Lighting System in the building and in the site for outdoor lighting, etc. shall be made and the applicant shall give a bank guarantee to this effect to the sanctioning authority for compliance of the same.
(iv) Common pool parking area (in the case of Group Housing Scheme / Cluster Housing / Row Housing Schemes).
(v) Any of the above or all the above or combination of the above.
(vi) Wherever Mechanical system and car lifts are proposed enabling two tier parking, the required parking is computed accordingly.
(c) The other aspects for providing parking spaces are:
(i) Misuse of the area specified for parking of vehicles for any other use shall be summarily demolished / removed by the Enforcement Authority.
(ii) The parking spaces should be efficiently designed and clearly marked and provided with adequate access, aisle, drives and ramps required for maneuvering of vehicles.
(iii) Cellar floor shall be used only for parking and not for any habitation purpose. There shall be ventilation to cellars with not less than 2.5% of each cellar floor area.
(iv) In respect of Apartment Complexes / Building / Block of residential nature, in sites up to 750sq.m the Parking requirement shall be deemed to be met if the entire stilt floor is left for parking.
(v) Common and Continuous cellar parking floors between adjoining buildings would be allowed depending upon structural safety aspects, mutual agreement between owners, etc.
(vi) In the Stilt floor a watchman room and 2 toilets (W.C), with maximum built up area of 25sq.m may be allowed. Such space shall not be disposed and shall be part of common facility of the complex. For the sites above 750sq.m area it is permitted subject to fulfillment of parking requirement as per Table-V.
(vii) For parking spaces in basements and upper floors, at least two ramps of minimum 3.6m width or one ramp of minimum 5.4m width and adequate slope 1 in 8 shall be provided. Such ramps shall not be allowed in mandatory setbacks including building line, however they may be permitted in the side and rear setbacks after leaving minimum 7m of setback for movement of fire-fighting vehicles. Access to these may also be accomplished through provisions of mechanical lifts.
(viii) The minimum width of the drive way shall be 4.5m.
(ix) In case where the permissible set back is less than 4.6m the pillars position in stilt floor shall be so designed that there shall be clear space of 3.6m (excluding Greenery) is available for movement of vehicles.
(x) Cellar shall be with a setback of at least 1.5m in the sites of extent of up to 1000sq.m, 2m in the sites of extent of more than 1000sq.m and up to 2000sq.m, and 3m in the sites of extent of more than 2000sq.m from the property line. In case of more than one cellar, 0.5m additional setback for every additional cellar floor shall be insisted.
(xi) Up to 10% of cellar may be utilised for utilities and non-habitation purpose like A/C Plant room, Generator room, Sewerage Treatment Plant (STP), Electrical installations, Laundry, etc,
(xii) Visitors’ parking shall be provided with minimum 10% of the parking area mentioned in Table-V and may be accommodated in the mandatory setbacks other than front setback where ever such setbacks are more than 6m (excluding green strip).How ever this is not permissible in case of transfer of setback. The Visitors’ Parking facility shall be open to all visitors which shall be properly demarcated on ground.
(xii) In case of Group Housing Buildings where there are 100 units and above, Nursing Homes, Hospitals and Hotels provision for Recycling of Water shall be made.