(1) The Floor Area Ratio and Ground Coverage in between two consecutive slabs of the “Plot size” table shall be calculated on interpolation basis.
(2) The total covered area for calculation of Floor Area Ratio shall consist of the areas of all the floors with the circulation spaces, spaces for sanitary facilities and other ancillary
areas within the building including the area of basement or cellar, area of the mezzanine floors, area of walls, pillars and other structural members, the area of all the projections, but shall not include the following :—
(a) Stair well area, the stair case with landing up to the extent of the width of the stairway in each floor;
(b) stair cover not exceeding 2.6 meters in height;
(c) projection for cornice, weather shade, chajja; (up to 500 mm). The length of chajja in such cases should be restricted to the width of the opening plus 100 mm. on either side of the opening. Projection of Architectural features like vertical-fringe are allowed up to 500 mm which will not be counted in covered area/F.A.R. No such projection shall be allowed in the ground floor, below the lintel level for any building(s);
(d) lift machine rooms as per the National Building Code;
(e) roof tanks and their supports, the height of support not exceeding 0.75 metre;
(f) ventilating, air-conditioning and service equipment attached to the building:
Provided that the aggregate area of these structures mentioned at clauses (a) to (f) shall not exceed one-third the area of the roof upon which these are erected;
(g) area of loft;
(h) the covered area used for car, bus and truck parking spaces as may have been provided for the required number of cars, buses or trucks in accordance with the provision of rule 23;
(i) the area of covered car parking spaces as may have been provided for the community car parking required in accordance with the rule 23;
(j) for building above four storied in height, areas for a servants room and toilet (maximum 15 square meter), darwans/quarters for caretakers (maximum 15 square meter); generator room with all services provided, for the project, in ground and basement;
(k) rain water harvesting tanks and other accessories, if any;
(l) fire refuge area of 15 square meter or an area equivalent to 0.3 square meter per person;
(m) area of service floor having maximum clear height of 1800 mm. may be allowed between any two floors for plumbing, electrical and other utility services in case of all hotel buildings under assembly use and hospital buildings under institutional use other than residential use;
(o) full area of the terrace, open to sky.
(3) The essential utilities within a plot shall be water supply, sewerage, drainage, solid waste management and power supply services. The structures and appurtenant to be used exclusively for these five categories of essential utilities shall be exempt from the provision of ground coverage and Floor Area Ratio for the particular plot.
(4) Where a land if gifted to WBHIDCO (i.e. the Planning Authority) for road construction as per alignment in finally published LUDCP under the West Bengal Town and Country (Planning and development) Act, 1979 (West Ben. Act XIII of 1979) or approved Master Land Use Plan (MLUP), the amount of built up area allowed shall be the same as it would have been before the gifting of such plot of land.
Open space.– (1) Open Space means an area forming an integral part of the plot, open to the sky and no chajja or cornice or weather shade more than 75 mm. widths shall overhang or project thereon. The total area of open spaces in a plot shall be as follows :—
The area of Open Space in a Plot = (Total area of the Plot) – (Area of the plot covered by Building when vertically projected on the ground level)
(2) Every building shall have marginal open spaces comprising front open space, rear open space and side open spaces. The minimum width prescribed for front open space, rear open space and side open spaces shall be provided along the entire front face, rear face and side faces of the building respectively. For this purpose, the front face of the building shall be that face of the building that faces the means of access and the rear face of a building shall be deemed to be that face of the building, which is farthest from the means of access.
(3) In the marginal open space one or more “Gate Goomti” for security purpose may be allowed. The covered area of each “Goomti” shall not exceed 3.00 square meters and the height of such “Goomti” shall not exceed 3.00 meters, Provided that in case of land area of two hectares or more, such area of gate goomti may be increased upto twelve square meters.
(4) The minimum front open space shall be as follows :—
Table – V
Type of building
Minimum front open space for building height in meter
Up to 15.1 m.
Above 15.1 m.
Residential
1.2 meter
15% of building height or 3.5 meter which ever is more;
Educational, Institutional, Mercantile (Retail), Business including IT and ITES, Assembly,
25% of building height or 5 meter whichever is more
“Joint Principal use (a) Business-Mercantile (Retail), Mercantile (Retail)-Assembly and (b) Business-Assembly in two rows are to be incorporated in table X.
(6) The minimum side open space shall be as follows :—
Table – VII
Type of building
Minimum side open spaces for building height in meter
Side 1 Open Space
Side 2 Open Space
Upto 15.1 m.
Above 15.1 m.
Upto 15.1 m.
Above 15.1 m.
Residential
Plot area upto 330 sq m
0.8 metres
15% of building height or 3.5 meters which ever is more,
2.4 meters,
15% of building height or 3.5 meters which ever is more,
Other building
15% of building height or 3.5 meters which ever is more,
15% of building height or 3.5 meters which ever is more,
(7) Inter Open Space between two buildings, within a plot, shall be 20% of the height of the lower building subject to a minimum of 3.2 meter and maximum of 12m.
(a) Side 1 of any plot shall always be adjacent to narrower side 2 of adjoining plot. No two narrow sides shall be adjacent;
(b) Facing a plot from the means of access, the left hand side of the plot shall be treated as side 1 and the right hand side of the plot shall be treated as side 2.
(7)A. Minimum open space for residential plots with plot area up to 3 Cottah or 200 sq.mt. shall be as follows:
a) Maximum allowable ground coverage – 65%
b) Minimum front open space required – 0.75 Mt.
c) Minimum rear open space required – 3.0 Mt.
d) Minimum side 1 open space required – 0.9 Mt.
e) Minimum side 2 open space required – 1.2 Mt.
(8) Inner Courtyard and Outer Courtyard and Ventilation Shaft
Every room intended for human habitation or kitchen shall abut an inner courtyard or outer courtyard or marginal open space or an open verandah which is open along its length into the courtyard or marginal open space.
(a) For Inner Courtyard
In case any room, excepting bath, water-closets and store-room, is not abutting any marginal open spaces, it shall abut on inner courtyard whose minimum width shall be 30% of the height of the building or 3.20 meters, whichever is more, If an inner courtyard is formed by a composite block of higher and lower blocks, the minimum width of courtyard shall be determined by the maximum height of lower block;
(b) For Outer Courtyard
(i) the minimum width of such courtyard shall not be less than 20% of the height of the lower building or 3.2 meter whichever is more, upto a maximum limit of 10.0 m.
(ii) the maximum depth of that courtyard shall not be more than 1.5 times the width;
(iii) outer courtyard having depth upto 1.2 metres shall be treated as a “Recess” not a courtyard.
Chapter II
Mixing of uses or occupancies. –(1) Every plot on which erection of building will be undertaken shall be provided with a principal use or joint principal use by the Development Authority.
Note: A joint principal use in this context shall be a combination of any two permissible principal uses which together shall be covering at least eighty percent of the total use and each of them shall be covering at least thirty percent of the total floor area of the building in a plot.
(2) The mixing of the other uses or occupancies with the joint principal use(s) or occupancy shall be allowed as mentioned in Table – I below:
Note: Hazardous use cannot be mixed with any other uses in a building. In plots with industrial as the principal use, exclusive hazardous use may be permitted with prior specific approval of the Planning Authority.
Means of access.–Means of access shall be in the following manner:—
(a) every plot shall about a means of access;
(b) entry from plots to the adjacent public open spaces shall not be allowed without specific written permission from the Development Authority;
(c) building(s) in a plot not abutting on a means of access shall abut on an internal road.
(d) in plots above 10 ha organized park(s) provided within the plot, shall abut on an internal road.
(e) the minimum width of internal road for different size of plots shall be as given in Table- II below:
Table – II
Minimum Width of Internal Roads for different size of plot:
Plot size
Minimum width of Internal Roads;
Upto 1500 square meters
3.50 meters;
Above 1500 square meters upto 1 hectares
4.50 meters;
Above 1 hectare upto 2 hectares
5.50 meters;
Above 2 hectares upto 10 hectares
7.00 meters;
Above 10 hectares
10.00 meters;
Height of buildings.–(1) The following appurtenant structures shall not be included in the height of the building :–
(a) stair cover not exceeding 2.6 metres in height from the surface of the roof;
(b) lift machine rooms as per the latest edition of the National Building Code.;
(c) roof tanks and their supports, the height of support not exceeding 0.75 meter and the top of the tank not exceeding 3 meters from the surface of the roof or highest point of the building ;
(d) parapet walls or railings not exceeding 1.2 meters in height;
(e) ventilating, air-conditioning and other service equipment;
(f) dome, minaret, kiosk and other non-usable feature not exceeding 3.5 meters in height; Note:
(a) There shall be provision for lift in buildings having height more than 15.1 m.
(b) No appurtenant structure shall be constructed on another appurtenant structure to be exempted only for Over Head Water Tank;
(2) The maximum permissible height of the building excluding the appurtenant structure specified sub rule (1) for different width of Means of Access shall be as follows :–
Table – III
Width of Means of Access
Maximum Permissible Height excluding the appurtenant structures
Upto 10 meter
15.1 meter
Above 10 meter Upto 20 meter
2.00 × (Width of means of access)
Above 20 meter upto 40 meter
2.00 × (Width of means of access)
Above 40 meter
No restriction
Note: Clearance for microwave system for Tele-communication purpose in accordance with such rules or direction issued by or on behalf of Government of India. No Objection Certificate from the Civil Aviation Authority shall have to be submitted for construction of building.
(3) The minimum clear height of a floor shall be 2.7 meter provided that for service floor, this shall not be more than 1.8 m and for Mezzanine Floor, this shall be minimum 2.2 meter.
Floor area ratio (F.A.R.) and ground coverage. –
The Floor Area Ratio and Ground Coverage shall be as given below in Table IV
Table – IV
Plot size (square meter/ hectare)
Residential building, Educational building and Institutional building.
Industrial building, Storage building, mercantile (wholesale) building and Hazardous building.
Business building, Mercantile (retail) building, Assembly building, Business-Assembly, Business-Mercantile (retail) and Mercantile (retail)-Assembly.
Information Technology and Information Technology Enabled Services.
Maximum permissible F.A.R.
Maximum permissible Ground Coverage
Maximum permissible F.A.R.
Maximum permissible Ground Coverage
Maximum permissible F.A.R.
Maximum permissible Ground Coverage
Maximum permissible F.A.R.
Maximum permissible Ground Coverage
Below 1500 square meter
2.5
55%
1.5
40%
2.0
45%
2.5
45%
4000 square meter
2.35
50%
1.5
40%
2.0
40%
2.5
40%
2 hectare
2.25
45%
1.5
40%
2.0
40%
2.5
40%
10 hectare
2.0
40%
1.5
40%
2.0
35%
2.0
40%
20 hectare
1.75
35%
1.5
40%
2.0
35%
2.0
40%
Above 20 hectare
1.5
35%
1.5
40%
2.0
35%
2.0
40%
Sub-Central Business District
-
-
-
-
2.25
35%
2.0
40%
Central Business District
-
-
-
-
2.5
35%
2.5
40%
Provided that some incremental FAR to buildings may be allowed over and above the FAR ordinarily available under existing rules in the following manner:
A) 10% additional FAR is to be allowed in case of green buildings and granting of this 10% additional FAR shall be given as per provisions of the notification from Urban Development Department, Govt. of West Bengal, Vide No. 2052 – UD/O/M/HID/5M – 28/2016, dated 11th July, 2016.
[Explanation: For the definition of ‘Green Building’ specification of the incremental fees/charges, on the additional FAR, the guideline for the certification and grant of additional FAR and designated agencies for certification of ‘Green Building’ within New Town, Kolkata, the following clauses as notified from Urban Development Department, Govt. of West Bengal, Vide No. 2052 – UD/O/M/ HID/5M – 28/2016, dated 11th July 2016. Shall be referred:
i. Definition: ‘Green Building’ inter alia means a structure created by using processes that are environmentally responsible and resource efficient throughout the building’s life cycle i.e. from design, construction, operation, maintenance, renovation and demolition.
ii. 10% additional FAR for ‘Green Building’ shall be allowed only for buildings which have been granted ‘Gold’ rating or higher under Indian Green Building Council (IGBC) rating system or at least ‘Four Star’ rating or higher under GRIHA rating system.
iii. Sanction of building plan for construction of ‘Green Building’ and grant of additional FAR shall be allowed on the basis of pre-certification by the designated agencies that are following GRIHA/ IGBC rating system as mentioned hereinafter.
iv. The projects which are under construction/ implementation and Pre-certified under the rating system will also be eligible for additional FAR subject to observation of the other conditions mentioned in the relevant Notification issued by Municipal Affairs Department.
v. Periodic inspection during the construction in regard to compliance of ‘Green Building norms shall be done by the rating agencies who has issued the pre-certification.
vi. Grant of additional FAR should not be in contravention of any building rules of any regulatory/statutory authorities.
vii. Plan sanctioning authority i.e. New Town Kolkata Development Authority may issue partial completion certificate on the basis of inspection report from the rating agency. However, final completion certificate shall be issued by the Authority only after receipt of the ‘FINAL CERTIFICATION’ from the rating agency.
viii. In case of non-compliance of the guidelines and upon failure to obtain the rating as mentioned above, penalty equivalent to one hundred fifty percent of the value of the floor area sanctioned for availing the additional FAR as per IGR value of the said building, shall be imposed by the Plan Sanctioning Authority i.e. New Town Kolkata Development Authority.
ix. Agencies designated for certification: the agencies to be notified, which follow the rating programme given below will be the designated agencies for certification (Pre-certification or Provisional certification and Final-certification of ‘Green Building’)
Green Rating Integrated Habitat Assessment (GRIHA) India and
Indian Green Building Council (IGBC)]
B) 15% additional FAR is to be granted in case of mass housing projects, hospitals, IT buildings, mega commercial projects etc., if there are adequate urban infrastructure and facilities available in the locality to cater to the enhanced civic demands.
Provided that in case of IT/ITES developers, 15% additional FAR shall be allowed in respect of plot of land abutting minimum 12 Mt. wide roads.
C) In areas within 500 mtrs. On either sides of the under construction Metro Corridor where construction work has actually begun a maximum of 15% additional FAR is to be allowed over the prescribed amount for properties abutting 15 meter to 24 meter wide roads and a maximum of 20% additional FAR is to be allowed over the prescribed amount for properties abutting more than 24 meter wide roads.
D) To ensure equitable and inclusive growth, housing society for Low Income group people and economically weaker section and to encourage ‘Affordable Housing’ projects for these categories, 10% additional FAR may be allowed only in case of exclusively affordable housing projects having plot area 5000 sq.mt. or more.
[Explanation: Affordable Housing Project means the residential complex consisting of LIG/EWS or any combination of the above two category only. for definition of LIG and EWS category, the following criteria as notified by Govt. of West Bengal, Urban Development Department Vide No. 1448/T & CP/C-2/3A-2/2011, dated 20th July 2011 shall have to be followed:
1
2
3
4
5
6
Sl. Nos.
Beneficiary Category
Beneficiary Monthly Income
Carpet area in case of walk up apartment per family unit
Plot size in case of plotted development per family unit
Minimum project (Housing/ sub-division of plot or land) area
1.
EWS
Up to Rs. 6000.00
Not less than 20 Sq.m.
Not less than 30 Sq.m.
5000 Sq.m.
2.
LIG
Rs. 6000.00 to Rs. 10,000.00
Not less than 34 Sq.m.
35 Sq.m. to 65 Sq.m.
5000 Sq.m.
E) The benefits as mentioned above in sub-rules (A) to (D) may be simultaneously availed provided that, during calculation of the additional F.A.R (in each case) basic allowable F.A.R shall be considered as detailed in Rule 21, Table IV and Rule 25A.
In case of CBD and Sub-CBD, the facilities of additional F.A.R due to proximity to metro corridor can be availed only once (i.e. either as per provision of sub-rule (C) above or as per sub-rule (f) of Rule 25A of this Rules.
Illustration – 1:
Say, Basic F.A.R as per existing Rules (Rule 21, Table IV) = 2
Say, Additional F.A.R for Green Building = 10% of 2 = 0.2
Say, Additional F.A.R for Mega Commercial project = 15% of 2 = 0.3
Say, Additional F.A.R for metro alignment = 20% of 2 = 0.4
Say, Additional F.A.R for Affordable Housing = 10% of 2 = 0.2
Hence, final permissible F.A.R = 2+0.2+0.3+0.4+0.2 = 3.1
= 4 + 0.225 + 0.3375 + 0.225 = 4.7875
Illustration – 2 (For Sub-CBD plots within 250 mt. of proposed metro rail corridor/ LRT corridor)
Say, Basic F.A.R as per existing Rules (Rule 21, Table IV) = 2.25
Maximum allowable FAR for location within 250 mt.
of proposed metro rail corridor as per sub-rule (f)
of Rule 25A of this Rules
Say, Additional F.A.R for Green Building = 10% of 2.25 = 0.2250
Say, Additional F.A.R for Mega Commercial project = 15% of 2.25 = 0.3375
Say, Additional F.A.R for Affordable Housing = 10% of 2.25 = 0.2250
= (3.0675 + additional FAR for metro alignment as per provision of sub-rule (C) of rule 21 i.e. 20% of 2.25 )
= 3.4875
The facilities of additional FAR due to proximity to metro corridor can be availed only once (i.e. either as per provision of sub-rule (C) of rule 21 above or as per sub-rule (f) of rule 25A of these rules)
Illustration – 3 (For Sub-CBD plots beyond 250 mt. of proposed metro rail corridor/ LRT corridor)
Say, Basic F.A.R as per existing Rules (Rule 21, Table IV) = 2.25
Say, Additional F.A.R for Green Building = 10% of 2.25 = 0.2250
Say, Additional F.A.R for Mega Commercial project = 15% of 2.25 = 0.3375
Say, Additional F.A.R for metro alignment = 20% of 2.25 = 0.4500
Say, Additional F.A.R for Affordable Housing = 10% of 2.25 = 0.2250
Hence, final permissible F.A.R =2.25+0.225+0.3375+0.4500+0.225 = 3.4875
Additional FAR for metro alignment sub-rule (f) of Rule 25A of these rules is not applicable in this case.
Illustration – 4 (For CBD plots within 250 mt. of proposed metro rail corridor/LRT corridor)
Say, Basic F.A.R as per existing Rules (Rule 21, Table IV) = 3.5
Maximum allowable FAR for location within 250 mt.
of proposed metro rail corridor as per sub-rule (f)
of Rule 25A of this Rules
Say, Additional F.A.R for Green Building = 10% of 3.5 = 0.350
Say, Additional F.A.R for Mega Commercial project = 15% of 3.5 = 0.525
Say, Additional F.A.R for Affordable Housing = 10% of 3.5 = 0.350
Hence, final permissible F.A.R =3.5+0.350+0.525+0.350 = 4.725
= 6+0.350+0.525+0.350 = 7.225
Or
= (4.725 + additional FAR for metro alignment as per provision of sub-rule (C) of rule 21 i.e. 20% of 3.5 )
= 5.425
The facilities of additional FAR due to proximity to metro corridor can be availed only once (i.e. either as per provision of sub-rule (C) of rule 21 above or as per subrule (f) of rule 25A of these rules)
Illustration – 5 (For CBD plots within 250 mt. of proposed metro rail corridor/LRT corridor)
Say, Basic F.A.R as per existing Rules (Rule 21, Table IV) = 3.5
Say, Additional F.A.R for Green Building = 10% of 3.5 = 0.350
Say, Additional F.A.R for Mega Commercial project = 15% of 3.5 = 0.525
Say, Additional F.A.R for metro alignment = 20% of 3.5 = 0.700
Say, Additional F.A.R for Affordable Housing = 10% of 3.5 = 0.350
Hence, final permissible F.A.R = 3.5+0.350+0.525+0.700+0.350 = 5.425
Additional FAR for metro alignment sub-rule (f) of Rule 25A of these rules is not applicable in this case.
25A. Special provision Central Business District
Notwithstanding anything contained in the aforesaid rule the following rules are applicable for the Central Business District as stated below:–
(a) The Principal Uses as well as the ‘Uses Not Permissible for Mixing’ and; Uses Permissible for Mixing shall be as given in the following Table – 1
Permissible Principal Uses
Uses not permissible for mixing
Assembly, Business & Mercantile (Retail)
Mercantile (Wholesale), Storage, Industrial & Hazardous.
(b) Any one, or a combination of any two, or of all the three permissible principal uses mentioned above shall be applicable to all the plots in CBD excepting plots under ‘Specific Uses’. The principal use or a combination of principal use altogether shall cover at least 51% of the total floor area of the building in a plot. Mixing with other permissible uses (Residential, Educational, Institutional and IT / ITES) shall be allowed provided that together they shall not be more than 49% of the total floor area of the building in a plot.
(c) In Central Business District for the plots abutting the main north-south street corridors, as well as the Central Green Pedestrian Plaza, the ground and first floor levels of all buildings will be uses exclusively for Mercantile (Retail) purpose including circulation areas as necessary, provided that the two corner plots earmarked for Hotel will not be required to fulfil this condition.
(d) In Central Business District, the main north-south street corridors, as well as Central Green & of the plot along these streets/facilities, will be treated as the front of the plot, provided that the two corner plots earmarked for hotel will not be required to fulfil this condition.
(e) In Central Business District, the buildings on the plots abutting the main north-south street corridors, as well as the Central Green & pedestrian Plaza, arcade will have to be provided within the front open space along the entire frontage of all these plots. The arcade at ground level shall be kept free for movement of pedestrians at footpath level. The arcade at the first floor level shall remain open to sky and shall not be covered by any permanent structure. The area covered by arcade at the ground level shall be exempted for calculation of Floor Area Ratio and ground coverage, the minimum width (depth) of the arcade shall be 6 m. the spacing of the columns in the arcade shall be 6m. centre to centre.
(f) FAR for the plots located within 250 Mtrs. From the proposed Metro Rail/ LRT Corridor in the CBD area shall be considered to the maximum as 6 and the same in the Sub-CBD area shall be considered to the maximum as 4 for all category of uses as enumerated in Table 0I other that ‘Residential’. However, plots located beyond 250 Mtrs. From the proposed Metro Rail/LRT Corridor FAR for all plots except ‘Residential’ shall remain as 3.50 for CBD area and 2.25 for Sub-CBD area. This is subject to payment of upfront fees as may be determined by the Planning Authority and compliance of the restrictions imposed by different other authorities already applicable under this rules.
The proposed Metro Rail/LRT Corridor and the distance of the plot therefrom shall be defined by the Planning Authority of the township.
(g) For plots with any Specific Use the maximum permissible FAR shall be as given in the Table – 2 below :—
Table – 2
Specific Use
Maximum Permissible FAR
Hotel
3.5
Bus Terminus
1.5
Police Station
2.5
Fire Station
2.0
Communication Tower
3.5
Petrol Pump
1.0
Para transit Terminus
1.0
(h) For community garage there will be no restriction of FAR, provided that at least 70% of the constructed total area of the building shall be used for car parking purpose and the remaining may be put to permissible uses.
(i) The maximum permissible Ground Coverage of CBD Plots shall be 35%
(j) Subject to the Special Provisions mentioned under clauses (a) to (i) all other rules of the New Town Kolkata (Building) Rules, 2009 shall be applicable to the CBD Plots. In applying such rules, the Specific Uses mentioned in clause (g) shall all be considered to be under Assembly Use”
Provided further that:
i. The grant of additional FAR must be in conformity with the LUDCP and must not contravene the norm for structural stability and or any norm of other regulatory authorities (e.g. environmental department, Pollution Control Board, Fire & Emergency Services authority, Airport Authority etc.)
ii. The rate / fee / charge payable for the additional FAR as detailed in sub-rule (A) – (C) shall be decided in terms of “Land price / Lease Premium rates” of WBHIDCO Ltd. For availing additional F.A.R as per sub-rule (D) for “Affordable Housing” no such rate /fee / charge shall be payable. All incremental fees / charges collected on account of grant of additional FAR will be payable to WBHIDCO Ltd directly.
F) As per Notification Vide No. 36 – TW/5T – 06/2015; dated 6th January 2015, published by Tourism Department, Govt. of West Bengal, an approved mega project of an eligible unit shall be entitled to additional Floor Area Ratio (FAR) of 0.25 over and above the existing maximum permissible FAR under this rule.
a. The rate/ fee/ charge payable for the additional FAR should be decided in terms of “Lease” Premium rates of WBHIDCO Ltd.
b. All incremental fees/charges collected on account of grant of additional FAR will be payable to WBHIDCO Ltd. Directly.
(9) Green Open Space within a plot
A part of the total Open Space in a plot shall be maintained as Green Open Space as specified in the table below.
Table – IX
Plot size
Minimum area of green open space
Upto 1500 sq m.
4% of plot area,
1 hectare
5% of plot area,
10 hectares
8% of plot area,
20 hectares
10% of plot area,
above 20 hectares
12% of plot area.
Note :
(a) The minimum area of green open space in between two consecutive slabs of the “Plot Area” shall be calculated on interpolation basis.
(b) The Green Open Space shall not be paved and shall be so maintained that rain water can percolate underground providing a suitable base vegetation/plantation.
(c) The provisions contained in West Bengal Trees (Protection and conservation in non-forest areas) Act, 2006 shall be taken into consideration.
(d) One tree cover shall be provided for each 80 sq.mt. of plot area as per provisions at Table-IX, However, at least one tree shall be planted in every plot irrespective of usegroup and plot size.
Parking space within a plot.– (1) (a) the minimum size of a car parking space shall be 2.50 m. × 5.00 m. and that for a L.C.V. shall be 3 m. × 7.5 m. and that for a truck or bus parking shall be 3.75 m. × 10.00 m. These sizes do not include the circulation spaces. The minimum width of circulation driveway with single side parking shall be 3.50 m. for cars and 5.00 m. for L.C.V. or trucks or buses if parking spaces are provided on both sides of the circulation driveway. The minimum width of such driveway shall be 5.0 m. for cars and 7 m. for L.C.V. or bus or truck.
(b) For calculating the number of parking as per norms laid down in sub-rule 2, the covered area shall be the same as the area for calculating of Floor Area Ratio ;
(c) the parking layout plan shall be so prepared that the parking as mentioned in sub-clause (a) of sub-rule 1 for each vehicle becomes directly accessible from the circulation driveway having minimum width as mentioned in clause (a) of sub-rule 1. However for residential buildings below 15.1 meters in height., back to back parking may be allowed;
(d) the open spaces within the plot may be allowed to be utilized for parking open to the sky, provided that minimum front open space, rear open space and side open spaces prescribed in rule 22 or 3.5 meters whichever is less are kept free from parking from the building line for plots having area more than 300 square meter.
(e) in case of a plot containing more than one building parking requirement shall be calculated for total covered area, on the basis of use of different uses.
(2) Provision for Car Parking Spaces shall be as follows :—
(a) parking provisions for different types of buildings are given in terms of car parking space in Table – X of these sub-rule.
(b) the space standards given below will be considered for calculation of exemption from permissible maximum floor area as mentioned in rule 21
(i) for ground floor parking–25 square meter per Car Parking space and 40 square meters. per L.C.V. parking bay and 60 square meter per Bus or Truck Parking space inclusive of circulation spaces.
(ii) for Basement and Upper floor/roof parking–30 square meter per Car Parking space and 50 square meter per L.C.V. parking space and 70 sq m. per Bus or Truck Parking space inclusive of circulation spaces.
(c) for the covered parking spaces, which do not have any covered space for circulation and have a direct access from the roads / internal roads, the exemption for car parking shall be 12.5 square meter per space and for L.C.V. parking shall be 22.5 square meter per bay and for bus or truck parking 37.5 square meters per bus or truck parking space. This is not applicable for residential buildings not exceeding 15.1 meter in height.
Note: Actual area used for the covered parking shall be considered for exemption for vehicles, which are at least fifty percent under cover. The minimum headroom (soffit of the beam) to be provided for cars shall be 2.5 meter and for truck or bus shall be 4.75 meters if parked in a covered area.
(3) The Development Authority may change ratio of usage pattern of car, LCV and Buses keeping the total area of parking spaces as mentioned in column 2 of Table – X of sub-rule (2);
(4) There may be provisions of mechanized multilayer parking facility in plots where there is difficulty in arranging parking space, even after constructing basement for car parking;
23. Parking space within a plot. –
(A)
Table – X
Type of building
Number of Car Parking spaces and minimum extent of parking spaces to be provided for cars, L.C.V. or truck or bus
1 parking space/100 square meters floor area Car: LCV:Bus=88:10:2
Assembly,
1.2 parking space/100 square meters floor area Car: Bus=98:2
Business, Business-Assembly,
1.5 parking space/100 square meters floor area Car: Bus=98:2
Industrial,
1 parking space/500 square meters floor area Truck: LCV:Car =80:15:5
Storage,
1 parking space/500 square meters floor area Truck: LCV:Car =40:40:20
It / ITES
1.5 parking space/100 square meters floor area
Provided that in case of LIG & EWS residential apartments, 3(three) two wheeler parking may be considered equivalent to each required car parking space.
(B) Space standards given below will be considered for calculation of exemption from permissible maximum floor area as mentioned in rule 21;–
(i) for ground floor parking up to a maximum extent of 25 sq m per car parking space and 40 sqm per L.C.V. parking bay and 60 square meters per Bus or Truck Parking space inclusive of circulation spaces;
(ii) for Basement and Upper floor or roof parking up to a maximum extent of 30 square meters per Car Parking space and 70 sqm per bus or truck parking space inclusive of circulation spaces;
(iii) for the covered parking spaces, which have uncovered spaces for circulation, the actual area used for covered parking shall be considered for exemption.
25. Fire protection of building. –
(1) Every building shall be provided with adequate means of exit as well as all arrangements and measures as per the provisions of the prevailing National Building Code for protection in case of fire. This should be duly certified by the Architect.
(2) Notwithstanding anything contained in these regulations in respect of following buildings, no permission for carrying out building operation shall be granted unless a No Objection Certificate from Directorate of Fire and Emergency Services, Government of West Bengal is given for,—
(a) Buildings on plot size exceeding 0.5 hectare;
(b) All residential buildings exceeding 15.1 meters in height;
(c) All buildings other than residential buildings.
(3) In case of buildings for which ‘No Objection Certificate’ will be required from Directorate of Fire and Emergency Services, Government of West Bengal, the Architect shall certify that the plans and drawings submitted by the Architect, incorporate the provisions recommended by the Directorate of Fire and Emergency Services, Government of West Bengal while issuing the No Objection Certificate.
[The certificate of Architect in Schedule – II as stated above will incorporate these provisions in case of such buildings.]
(4) One dedicated Fire Fighting Kiosk measuring 200 sq.ft. area, preferably located at ground floor for the following type of buildings:
All stand-alone Residential Buildings above 45 Mtr. Height.
All Residential Complex having floor area more than 2.0 Lac. Sq.ft.
All educational occupancy having provision of air conditioning, basement parking, laboratory, auditorium of 500 persons capacity and market complexes.
Other High Risk Buildings as specified in this Department’s Notification No. 279/DS/ FS/O/C-1/FIA-3/96, dated 08.07.2003 depending upon Building’s vulnerability to Fire.
Such kiosks shall contain the following equipment:
i. 4 nos. 4.5 kg. CO2 extinguisher.
ii. 4 nos. 4.5 kg. ABC type extinguisher.
iii. 2 nos. ceiling hook.
iv. 4 nos. Fire Bucket.
v. 1 no. Lock Cutter.
vi. 2 nos. 14 lb. Hammer.
vii. 2 nos. Crowbar.
viii. 1 no. Insulated Axe.
ix. 2 nos. Stretcher.
x. 2 nos. Smoke Hood.
xi. 2 nos. Torch Light.
(5) Lightning Arrester on all tall buildings/structures (more than 15.1 Mt. height) in New Town, Kolkata shall be installed mandatorily.
Chapter – IIA
(c) For ventilation shaft
(i) the width and size shall not be less than as given in Table -VIII of this clause;
(ii) no projection shall be allowed in the ventilation shaft. For all buildings suitable arrangements for access into the ventilation shaft shall have to be provided for maintenance of service lines;
Table – VIII
Ventilation shaft for toilet
Height of the building
Minimum size of ventilation shaft
Minimum width of the shaft
Upto 11.5 meters
3.0 square meter
1.5 meter
Above 11.5 meter and upto 15.1 meter
6.5 square meter
2.5 meter
Above 15.1 meter and upto 20.0 meter
8.0 square meter
2.75 meter
Above 20 meter
9.0 square meter
3.0 meter
(iv) actual area used for the covered parking shall be considered for exemption for vehicles, which are at least fifty percent under cover.
(C) Minimum headroom (soffit of the beam) to be provided for cars shall be 2.5 meters and for truck/bus shall be 4.75 meters if parked in a covered area.
(D) Where additional parking is provided in excess of parking space provided in accordance with the provisions of Table – X of sub-rule (A), in case of Big residential complexes, old residential high-rise buildings, Mega commercial project, hospitals and educational buildings etc. The additionally provided parking space shall not be counted as consumption of Floor Area Ratio (FAR)
(E) 2% of the car parking space shall have to be provided for electric vehicle charging facilities. At least one car parking space shall be equipped with electric vehicle charging facilities for all plots irrespective of use-group and plot size.
(F) For plot size above 10 hectare, 20% of the parking space shall have to be allotted for electric vehicle charging facilities. The said allotted space for electric vehicle charging facilities will be exempted from Floor Area Ratio (FAR) and Ground Coverage calculation provided that, the required mandatory parking space has to be provided as described in Rule 23 of the said Rule.
Note: For fractional car parking space, it will be rounded upto next whole number, if it is 0.5 or more.
(a) for plot size above 10 hectare Community Car Parking shall be provided at the rate of 20% of the car parking required for this plot under this rule;
(b) loading unloading space and embarking and disembarking spaces for L.C.V. and buses and trucks, if any, shall be provided within the plot. If parked in a covered space, minimum headroom of 4.75 meters shall have to be provided.
Provision for facilities and utilities.— (1) For all plots above 1 hectare and above in area, facilities and utilities shall be provided for the minimum requirements of which are indicated in the table below :—
Table – XI
Plot Area
Minimum Floor Area for facilities and utilities
Residential Building
Other Uses
Below 1 hectare
Nil
Nil
1 hectare
3% of total floor area in the plot
2.5% of total floor area in the plot,
2 hectares
4% of total floor area in the plot
3% of total floor area in the plot,
10 hectares
6% of total floor area in the plot
4% of total floor area in the plot,
50 hectares
7% of total floor area in the plot
6% of total floor area in the plot,
Above 50 hectares
8% of total floor area in the plot
7% of total floor area in the plot.
Note :
(a) the minimum floor area between two consecutive slabs of the plot area shall be calculated on interpolation basis;
(b) the Facilities for the purpose of this rule will comprise health, education and shopping facility and community spaces.
(2) Provision of Water body and forestry will be made for plot area above10 hectare.