(1) The Floor Area Ratio and Ground Coverage in between two consecutive slabs of the “Plot size” table shall be calculated on interpolation basis.
(2) The total covered area for calculation of Floor Area Ratio shall consist of the areas of all the floors with the circulation spaces, spaces for sanitary facilities and other ancillary
areas within the building including the area of basement or cellar, area of the mezzanine floors, area of walls, pillars and other structural members, the area of all the projections, but shall not include the following :—
(a) Stair well area, the stair case with landing up to the extent of the width of the stairway in each floor;
(b) stair cover not exceeding 2.6 meters in height;
(c) projection for cornice, weather shade, chajja; (up to 500 mm). The length of chajja in such cases should be restricted to the width of the opening plus 100 mm. on either side of the opening. Projection of Architectural features like vertical-fringe are allowed up to 500 mm which will not be counted in covered area/F.A.R. No such projection shall be allowed in the ground floor, below the lintel level for any building(s);
(d) lift machine rooms as per the National Building Code;
(e) roof tanks and their supports, the height of support not exceeding 0.75 metre;
(f) ventilating, air-conditioning and service equipment attached to the building:
Provided that the aggregate area of these structures mentioned at clauses (a) to (f) shall not exceed one-third the area of the roof upon which these are erected;
(g) area of loft;
(h) the covered area used for car, bus and truck parking spaces as may have been provided for the required number of cars, buses or trucks in accordance with the provision of rule 23;
(i) the area of covered car parking spaces as may have been provided for the community car parking required in accordance with the rule 23;
(j) for building above four storied in height, areas for a servants room and toilet (maximum 15 square meter), darwans/quarters for caretakers (maximum 15 square meter); generator room with all services provided, for the project, in ground and basement;
(k) rain water harvesting tanks and other accessories, if any;
(l) fire refuge area of 15 square meter or an area equivalent to 0.3 square meter per person;
(m) area of service floor having maximum clear height of 1800 mm. may be allowed between any two floors for plumbing, electrical and other utility services in case of all hotel buildings under assembly use and hospital buildings under institutional use other than residential use;
(o) full area of the terrace, open to sky.
(3) The essential utilities within a plot shall be water supply, sewerage, drainage, solid waste management and power supply services. The structures and appurtenant to be used exclusively for these five categories of essential utilities shall be exempt from the provision of ground coverage and Floor Area Ratio for the particular plot.
(4) Where a land if gifted to WBHIDCO (i.e. the Planning Authority) for road construction as per alignment in finally published LUDCP under the West Bengal Town and Country (Planning and development) Act, 1979 (West Ben. Act XIII of 1979) or approved Master Land Use Plan (MLUP), the amount of built up area allowed shall be the same as it would have been before the gifting of such plot of land.
Open space.– (1) Open Space means an area forming an integral part of the plot, open to the sky and no chajja or cornice or weather shade more than 75 mm. widths shall overhang or project thereon. The total area of open spaces in a plot shall be as follows :—
The area of Open Space in a Plot = (Total area of the Plot) – (Area of the plot covered by Building when vertically projected on the ground level)
(2) Every building shall have marginal open spaces comprising front open space, rear open space and side open spaces. The minimum width prescribed for front open space, rear open space and side open spaces shall be provided along the entire front face, rear face and side faces of the building respectively. For this purpose, the front face of the building shall be that face of the building that faces the means of access and the rear face of a building shall be deemed to be that face of the building, which is farthest from the means of access.
(3) In the marginal open space one or more “Gate Goomti” for security purpose may be allowed. The covered area of each “Goomti” shall not exceed 3.00 square meters and the height of such “Goomti” shall not exceed 3.00 meters, Provided that in case of land area of two hectares or more, such area of gate goomti may be increased upto twelve square meters.
(4) The minimum front open space shall be as follows :—
Table – V
Type of building
Minimum front open space for building height in meter
Up to 15.1 m.
Above 15.1 m.
Residential
1.2 meter
15% of building height or 3.5 meter which ever is more;
Educational, Institutional, Mercantile (Retail), Business including IT and ITES, Assembly,
25% of building height or 5 meter whichever is more
“Joint Principal use (a) Business-Mercantile (Retail), Mercantile (Retail)-Assembly and (b) Business-Assembly in two rows are to be incorporated in table X.
Chapter II
Mixing of uses or occupancies. –(1) Every plot on which erection of building will be undertaken shall be provided with a principal use or joint principal use by the Development Authority.
Note: A joint principal use in this context shall be a combination of any two permissible principal uses which together shall be covering at least eighty percent of the total use and each of them shall be covering at least thirty percent of the total floor area of the building in a plot.
(2) The mixing of the other uses or occupancies with the joint principal use(s) or occupancy shall be allowed as mentioned in Table – I below:
Note: Hazardous use cannot be mixed with any other uses in a building. In plots with industrial as the principal use, exclusive hazardous use may be permitted with prior specific approval of the Planning Authority.
Means of access.–Means of access shall be in the following manner:—
(a) every plot shall about a means of access;
(b) entry from plots to the adjacent public open spaces shall not be allowed without specific written permission from the Development Authority;
(c) building(s) in a plot not abutting on a means of access shall abut on an internal road.
(d) in plots above 10 ha organized park(s) provided within the plot, shall abut on an internal road.
(e) the minimum width of internal road for different size of plots shall be as given in Table- II below:
Table – II
Minimum Width of Internal Roads for different size of plot:
Plot size
Minimum width of Internal Roads;
Upto 1500 square meters
3.50 meters;
Above 1500 square meters upto 1 hectares
4.50 meters;
Above 1 hectare upto 2 hectares
5.50 meters;
Above 2 hectares upto 10 hectares
7.00 meters;
Above 10 hectares
10.00 meters;
Height of buildings.–(1) The following appurtenant structures shall not be included in the height of the building :–
(a) stair cover not exceeding 2.6 metres in height from the surface of the roof;
(b) lift machine rooms as per the latest edition of the National Building Code.;
(c) roof tanks and their supports, the height of support not exceeding 0.75 meter and the top of the tank not exceeding 3 meters from the surface of the roof or highest point of the building ;
(d) parapet walls or railings not exceeding 1.2 meters in height;
(e) ventilating, air-conditioning and other service equipment;
(f) dome, minaret, kiosk and other non-usable feature not exceeding 3.5 meters in height; Note:
(a) There shall be provision for lift in buildings having height more than 15.1 m.
(b) No appurtenant structure shall be constructed on another appurtenant structure to be exempted only for Over Head Water Tank;
(2) The maximum permissible height of the building excluding the appurtenant structure specified sub rule (1) for different width of Means of Access shall be as follows :–
Table – III
Width of Means of Access
Maximum Permissible Height excluding the appurtenant structures
Upto 10 meter
15.1 meter
Above 10 meter Upto 20 meter
2.00 × (Width of means of access)
Above 20 meter upto 40 meter
2.00 × (Width of means of access)
Above 40 meter
No restriction
Note: Clearance for microwave system for Tele-communication purpose in accordance with such rules or direction issued by or on behalf of Government of India. No Objection Certificate from the Civil Aviation Authority shall have to be submitted for construction of building.
(3) The minimum clear height of a floor shall be 2.7 meter provided that for service floor, this shall not be more than 1.8 m and for Mezzanine Floor, this shall be minimum 2.2 meter.
Floor area ratio (F.A.R.) and ground coverage. –
The Floor Area Ratio and Ground Coverage shall be as given below in Table IV
Table – IV
Plot size (square meter/ hectare)
Residential building, Educational building and Institutional building.
Industrial building, Storage building, mercantile (wholesale) building and Hazardous building.
Business building, Mercantile (retail) building, Assembly building, Business-Assembly, Business-Mercantile (retail) and Mercantile (retail)-Assembly.
Information Technology and Information Technology Enabled Services.
Maximum permissible F.A.R.
Maximum permissible Ground Coverage
Maximum permissible F.A.R.
Maximum permissible Ground Coverage
Maximum permissible F.A.R.
Maximum permissible Ground Coverage
Maximum permissible F.A.R.
Maximum permissible Ground Coverage
Below 1500 square meter
2.5
55%
1.5
40%
2.0
45%
2.5
45%
4000 square meter
2.35
50%
1.5
40%
2.0
40%
2.5
40%
2 hectare
2.25
45%
1.5
40%
2.0
40%
2.5
40%
10 hectare
2.0
40%
1.5
40%
2.0
35%
2.0
40%
20 hectare
1.75
35%
1.5
40%
2.0
35%
2.0
40%
Above 20 hectare
1.5
35%
1.5
40%
2.0
35%
2.0
40%
Sub-Central Business District
-
-
-
-
2.25
35%
2.0
40%
Central Business District
-
-
-
-
2.5
35%
2.5
40%
Provided that some incremental FAR to buildings may be allowed over and above the FAR ordinarily available under existing rules in the following manner:
A) 10% additional FAR is to be allowed in case of green buildings and granting of this 10% additional FAR shall be given as per provisions of the notification from Urban Development Department, Govt. of West Bengal, Vide No. 2052 – UD/O/M/HID/5M – 28/2016, dated 11th July, 2016.
[Explanation: For the definition of ‘Green Building’ specification of the incremental fees/charges, on the additional FAR, the guideline for the certification and grant of additional FAR and designated agencies for certification of ‘Green Building’ within New Town, Kolkata, the following clauses as notified from Urban Development Department, Govt. of West Bengal, Vide No. 2052 – UD/O/M/ HID/5M – 28/2016, dated 11th July 2016. Shall be referred:
i. Definition: ‘Green Building’ inter alia means a structure created by using processes that are environmentally responsible and resource efficient throughout the building’s life cycle i.e. from design, construction, operation, maintenance, renovation and demolition.
ii. 10% additional FAR for ‘Green Building’ shall be allowed only for buildings which have been granted ‘Gold’ rating or higher under Indian Green Building Council (IGBC) rating system or at least ‘Four Star’ rating or higher under GRIHA rating system.
iii. Sanction of building plan for construction of ‘Green Building’ and grant of additional FAR shall be allowed on the basis of pre-certification by the designated agencies that are following GRIHA/ IGBC rating system as mentioned hereinafter.
iv. The projects which are under construction/ implementation and Pre-certified under the rating system will also be eligible for additional FAR subject to observation of the other conditions mentioned in the relevant Notification issued by Municipal Affairs Department.
v. Periodic inspection during the construction in regard to compliance of ‘Green Building norms shall be done by the rating agencies who has issued the pre-certification.
vi. Grant of additional FAR should not be in contravention of any building rules of any regulatory/statutory authorities.
vii. Plan sanctioning authority i.e. New Town Kolkata Development Authority may issue partial completion certificate on the basis of inspection report from the rating agency. However, final completion certificate shall be issued by the Authority only after receipt of the ‘FINAL CERTIFICATION’ from the rating agency.
viii. In case of non-compliance of the guidelines and upon failure to obtain the rating as mentioned above, penalty equivalent to one hundred fifty percent of the value of the floor area sanctioned for availing the additional FAR as per IGR value of the said building, shall be imposed by the Plan Sanctioning Authority i.e. New Town Kolkata Development Authority.
ix. Agencies designated for certification: the agencies to be notified, which follow the rating programme given below will be the designated agencies for certification (Pre-certification or Provisional certification and Final-certification of ‘Green Building’)
Green Rating Integrated Habitat Assessment (GRIHA) India and
Indian Green Building Council (IGBC)]
B) 15% additional FAR is to be granted in case of mass housing projects, hospitals, IT buildings, mega commercial projects etc., if there are adequate urban infrastructure and facilities available in the locality to cater to the enhanced civic demands.
Provided that in case of IT/ITES developers, 15% additional FAR shall be allowed in respect of plot of land abutting minimum 12 Mt. wide roads.
C) In areas within 500 mtrs. On either sides of the under construction Metro Corridor where construction work has actually begun a maximum of 15% additional FAR is to be allowed over the prescribed amount for properties abutting 15 meter to 24 meter wide roads and a maximum of 20% additional FAR is to be allowed over the prescribed amount for properties abutting more than 24 meter wide roads.
D) To ensure equitable and inclusive growth, housing society for Low Income group people and economically weaker section and to encourage ‘Affordable Housing’ projects for these categories, 10% additional FAR may be allowed only in case of exclusively affordable housing projects having plot area 5000 sq.mt. or more.
[Explanation: Affordable Housing Project means the residential complex consisting of LIG/EWS or any combination of the above two category only. for definition of LIG and EWS category, the following criteria as notified by Govt. of West Bengal, Urban Development Department Vide No. 1448/T & CP/C-2/3A-2/2011, dated 20th July 2011 shall have to be followed:
1
2
3
4
5
6
Sl. Nos.
Beneficiary Category
Beneficiary Monthly Income
Carpet area in case of walk up apartment per family unit
Plot size in case of plotted development per family unit
Minimum project (Housing/ sub-division of plot or land) area
1.
EWS
Up to Rs. 6000.00
Not less than 20 Sq.m.
Not less than 30 Sq.m.
5000 Sq.m.
2.
LIG
Rs. 6000.00 to Rs. 10,000.00
Not less than 34 Sq.m.
35 Sq.m. to 65 Sq.m.
5000 Sq.m.
E) The benefits as mentioned above in sub-rules (A) to (D) may be simultaneously availed provided that, during calculation of the additional F.A.R (in each case) basic allowable F.A.R shall be considered as detailed in Rule 21, Table IV and Rule 25A.
In case of CBD and Sub-CBD, the facilities of additional F.A.R due to proximity to metro corridor can be availed only once (i.e. either as per provision of sub-rule (C) above or as per sub-rule (f) of Rule 25A of this Rules.
Illustration – 1:
Say, Basic F.A.R as per existing Rules (Rule 21, Table IV) = 2
Say, Additional F.A.R for Green Building = 10% of 2 = 0.2
Say, Additional F.A.R for Mega Commercial project = 15% of 2 = 0.3
Say, Additional F.A.R for metro alignment = 20% of 2 = 0.4
Say, Additional F.A.R for Affordable Housing = 10% of 2 = 0.2
Hence, final permissible F.A.R = 2+0.2+0.3+0.4+0.2 = 3.1
= 4 + 0.225 + 0.3375 + 0.225 = 4.7875
Illustration – 2 (For Sub-CBD plots within 250 mt. of proposed metro rail corridor/ LRT corridor)
Say, Basic F.A.R as per existing Rules (Rule 21, Table IV) = 2.25
Maximum allowable FAR for location within 250 mt.
of proposed metro rail corridor as per sub-rule (f)
of Rule 25A of this Rules
Say, Additional F.A.R for Green Building = 10% of 2.25 = 0.2250
Say, Additional F.A.R for Mega Commercial project = 15% of 2.25 = 0.3375
Say, Additional F.A.R for Affordable Housing = 10% of 2.25 = 0.2250
= (3.0675 + additional FAR for metro alignment as per provision of sub-rule (C) of rule 21 i.e. 20% of 2.25 )
= 3.4875
The facilities of additional FAR due to proximity to metro corridor can be availed only once (i.e. either as per provision of sub-rule (C) of rule 21 above or as per sub-rule (f) of rule 25A of these rules)
Illustration – 3 (For Sub-CBD plots beyond 250 mt. of proposed metro rail corridor/ LRT corridor)
Say, Basic F.A.R as per existing Rules (Rule 21, Table IV) = 2.25
Say, Additional F.A.R for Green Building = 10% of 2.25 = 0.2250
Say, Additional F.A.R for Mega Commercial project = 15% of 2.25 = 0.3375
Say, Additional F.A.R for metro alignment = 20% of 2.25 = 0.4500
Say, Additional F.A.R for Affordable Housing = 10% of 2.25 = 0.2250
Hence, final permissible F.A.R =2.25+0.225+0.3375+0.4500+0.225 = 3.4875
Additional FAR for metro alignment sub-rule (f) of Rule 25A of these rules is not applicable in this case.
Illustration – 4 (For CBD plots within 250 mt. of proposed metro rail corridor/LRT corridor)
Say, Basic F.A.R as per existing Rules (Rule 21, Table IV) = 3.5
Maximum allowable FAR for location within 250 mt.
of proposed metro rail corridor as per sub-rule (f)
of Rule 25A of this Rules
Say, Additional F.A.R for Green Building = 10% of 3.5 = 0.350
Say, Additional F.A.R for Mega Commercial project = 15% of 3.5 = 0.525
Say, Additional F.A.R for Affordable Housing = 10% of 3.5 = 0.350
Hence, final permissible F.A.R =3.5+0.350+0.525+0.350 = 4.725
= 6+0.350+0.525+0.350 = 7.225
Or
= (4.725 + additional FAR for metro alignment as per provision of sub-rule (C) of rule 21 i.e. 20% of 3.5 )
= 5.425
The facilities of additional FAR due to proximity to metro corridor can be availed only once (i.e. either as per provision of sub-rule (C) of rule 21 above or as per subrule (f) of rule 25A of these rules)
Illustration – 5 (For CBD plots within 250 mt. of proposed metro rail corridor/LRT corridor)
Say, Basic F.A.R as per existing Rules (Rule 21, Table IV) = 3.5
Say, Additional F.A.R for Green Building = 10% of 3.5 = 0.350
Say, Additional F.A.R for Mega Commercial project = 15% of 3.5 = 0.525
Say, Additional F.A.R for metro alignment = 20% of 3.5 = 0.700
Say, Additional F.A.R for Affordable Housing = 10% of 3.5 = 0.350
Hence, final permissible F.A.R = 3.5+0.350+0.525+0.700+0.350 = 5.425
Additional FAR for metro alignment sub-rule (f) of Rule 25A of these rules is not applicable in this case.
Provided further that:
i. The grant of additional FAR must be in conformity with the LUDCP and must not contravene the norm for structural stability and or any norm of other regulatory authorities (e.g. environmental department, Pollution Control Board, Fire & Emergency Services authority, Airport Authority etc.)
ii. The rate / fee / charge payable for the additional FAR as detailed in sub-rule (A) – (C) shall be decided in terms of “Land price / Lease Premium rates” of WBHIDCO Ltd. For availing additional F.A.R as per sub-rule (D) for “Affordable Housing” no such rate /fee / charge shall be payable. All incremental fees / charges collected on account of grant of additional FAR will be payable to WBHIDCO Ltd directly.
F) As per Notification Vide No. 36 – TW/5T – 06/2015; dated 6th January 2015, published by Tourism Department, Govt. of West Bengal, an approved mega project of an eligible unit shall be entitled to additional Floor Area Ratio (FAR) of 0.25 over and above the existing maximum permissible FAR under this rule.
a. The rate/ fee/ charge payable for the additional FAR should be decided in terms of “Lease” Premium rates of WBHIDCO Ltd.
b. All incremental fees/charges collected on account of grant of additional FAR will be payable to WBHIDCO Ltd. Directly.
(6) The minimum side open space shall be as follows :—
Table – VII
Type of building
Minimum side open spaces for building height in meter
Side 1 Open Space
Side 2 Open Space
Upto 15.1 m.
Above 15.1 m.
Upto 15.1 m.
Above 15.1 m.
Residential
Plot area upto 330 sq m
0.8 metres
15% of building height or 3.5 meters which ever is more,
2.4 meters,
15% of building height or 3.5 meters which ever is more,
Other building
15% of building height or 3.5 meters which ever is more,
15% of building height or 3.5 meters which ever is more,
(7) Inter Open Space between two buildings, within a plot, shall be 20% of the height of the lower building subject to a minimum of 3.2 meter and maximum of 12m.
(a) Side 1 of any plot shall always be adjacent to narrower side 2 of adjoining plot. No two narrow sides shall be adjacent;
(b) Facing a plot from the means of access, the left hand side of the plot shall be treated as side 1 and the right hand side of the plot shall be treated as side 2.
(7)A. Minimum open space for residential plots with plot area up to 3 Cottah or 200 sq.mt. shall be as follows:
a) Maximum allowable ground coverage – 65%
b) Minimum front open space required – 0.75 Mt.
c) Minimum rear open space required – 3.0 Mt.
d) Minimum side 1 open space required – 0.9 Mt.
e) Minimum side 2 open space required – 1.2 Mt.
(8) Inner Courtyard and Outer Courtyard and Ventilation Shaft
Every room intended for human habitation or kitchen shall abut an inner courtyard or outer courtyard or marginal open space or an open verandah which is open along its length into the courtyard or marginal open space.
(a) For Inner Courtyard
In case any room, excepting bath, water-closets and store-room, is not abutting any marginal open spaces, it shall abut on inner courtyard whose minimum width shall be 30% of the height of the building or 3.20 meters, whichever is more, If an inner courtyard is formed by a composite block of higher and lower blocks, the minimum width of courtyard shall be determined by the maximum height of lower block;
(b) For Outer Courtyard
(i) the minimum width of such courtyard shall not be less than 20% of the height of the lower building or 3.2 meter whichever is more, upto a maximum limit of 10.0 m.
(ii) the maximum depth of that courtyard shall not be more than 1.5 times the width;
(iii) outer courtyard having depth upto 1.2 metres shall be treated as a “Recess” not a courtyard.
(c) For ventilation shaft
(i) the width and size shall not be less than as given in Table -VIII of this clause;
(ii) no projection shall be allowed in the ventilation shaft. For all buildings suitable arrangements for access into the ventilation shaft shall have to be provided for maintenance of service lines;