(a) Every Residential Building, having height up to 12.5 meters, shall have a Rear Open Space, as below:-
S.No.
Plot area in Square meters
Minimum Rear Open space in meters
(1)
(2)
(3)
1.
Up to 40.00
Nil
2.
Above 40.00 and up to 150.00
1.50
3.
Above 150 and up to 225.00
2.50
4.
Above 225.00
3.00
(b) Rear open space to extend upto the rear wall : The rear open space shall be co-extensive with the entire face of the rear wall. If a building abuts on two or more streets, such rear open space shall be provided through-out the entire face of the rear wall. Such rear wall shall be the wall on the opposite side of the face of the building unless the Authority otherwise directs.
(7) Joint open air space for buildings -
(a) Every interior or exterior open air space, unless the latter is a street, shall be maintained and shall lie entirely within the owner's own premises.
(b) If such interior or exterior open air space is intended to be used for the benefit of more than one building belonging to the same owner, then the width of such open air space shall be equal to the one as specified for tallest building abutting on such open air space.
(c) If such interior or exterior open space is jointly owned by more than one person, then its width shall be as per (b) above :
Provided that every such person agrees in writing to allow his portion of such joint open space to be used for the benefit of every building abutting on such joint open space and provided he submits his written consent to the Authority for record. Such common open space shall henceforth be treated as a permanently open space required for the purposes of these rules. No boundary wall between such joint open space shall be erected or raised to a height above 2.0 meters.
Open spaces for other occupancies.- In case where the development permission under section 29 or 16 is applied for the following occupancies/buildings :-
(a) Educational Buildings - Except for nursery school, the open spaces around the building shall be not less than 6 meters.
(b) Institutional Building - The open spaces around the building shall not be less than 6 meters.
(c) Assembly Building- The open space at front shall not be less than 12 meters and other spaces around the building shall not be less than 6 meters.
(d) Business, Mercantile and Storage Buildings - The open spaces shall not be less than 6 meters in the front and 4.5 meters on other three sides, Where these are situated in purely residential zone or residential with shops line zone, the open spaces may be relaxed.
(e) Industrial Buildings - The open spaces around the building shall not be less than 4.5 meters for heights up to 16 meters with an increase of the open spaces of 0.25 meters for every increase of 1 meter or fraction thereof in height above 16 meters.
(f) Hazardous occupancies - The open space around the building shall be as specified for industrial buildings mentioned in clause (e) above.
Rule 58
81
Construction of commercial complex -- Leaving space of 4.5 meter as off-street parking and 4.5 meter as open space, these are two different requirements which are to be fulfilled and cannot be clubbed together. Satish Nayak Vs. State of M.P. and others, 2018 (2) RN 1 (HC) = 2018 Supreme 292 (MP).
Projections.- (1) Projection into open spaces - Every minimum open space provided on the exterior side and every open space provided on the interior shall be kept free from any construction thereon and shall be open to the sky except as below :-
(a) Cornice, roof or weather shade not more than 0.75 meter wide;
(b) Sunshade over window/ventilators or other openings not more than 0.75 meters wide;
(c) Projected balcony at first or higher floors extending upto 1.20 meters with clearance of 1.5 meters from plot boundary provided that such projected balcony shall not be constructed as a continuous projection on any side of the building,
(2) Projections mentioned above in sub-rule (1)(c) may be permitted on the inner courtyard, if the size of such courtyard is more than 9 meters x 9 meters.
(3) Projecting rooms at alternate floors may be allowed :
Provided that such projection,-
(a) do not obstruct the air and light of the lower two floors;
(b) do not project into the MOS; and
(c) shall not be more than the height of the storey immediately below.
(4) Accessory Building - The following accessory buildings may be permitted in the open spaces :-
(a) In existing building, sanitary block of 2.4 meters in height subject to a maximum of 4 square meters in the rear open space at a distance of 1.5 meters from the rear boundary may be permitted.
(b) Private garages with an area not exceeding 25 square meters shall be permitted in the rear end of side open spaces.
(c) Pump room and watchman hut each up to 6.0 square meter.
(5) Sunshades over windows and ventilators - Projections of sunshades over windows or ventilators in existing built-up or congested areas when permitted by the Authority shall fulfill the following conditions, namely :-
Rule 59-60
82
(a) no sun-shade shall be permitted over the road or over any drain or over any portion outside the boundaries of the site below a height of 2.8 meters from the road level;
(b) sunshades provided above a height of 2.8 meters from the ground level shall be permitted to project up to a maximum width of 60 centimeters, if the road over which they project exceeds 9 meters in width; and
(c) no sunshade shall be permitted on roads less than 9 meters width or on roads having no footpath.
Limitation to open spaces.- (1) Safeguard against reduction of open spaces - No construction work on a building shall be allowed if such work operates to reduce an open space of any other adjoining building belonging to the same owner to an extent less than what is prescribed at the time of the proposed work or to reduce further such open space if it is already less than that prescribed.
(2) Additions or Extensions to a building- Additions or extensions of building shall be allowed provided that the open spaces for the additions or extensions would satisfy these rules after such additions or extensions are made.
Group housing.- Planning Norms for Group Housing shall be as below :-
(1) The minimum land or plot area, ground coverage, minimum soft area and such other planning norms for group housing shall be as published by the State Government in the official Gazette.
(2) The coverage and floor area ratio for various densities may be as provided in Table 7 unless otherwise provided in the development plan.
TABLE 7FLOOR AREA RATIO AND COVERAGE FOR GROUP HOUSING [See Rule 60(2)]
S.No.
Gross residential density Persons/Hectare
Maximum coverage in per cent.
Floor Area Ratio
(1)
(2)
(3)
(4)
1.
125
25
0.75
2.
250
30
1.25
3.
425
33
1.50
4.
500
35
1.75
5.
625
35
2.00
Rule 61
83
Note : The coverage shall be calculated on the basis of the whole area reserved for group housing after deducting :-
(i) the area of any highway or any road of width 18 mtrs. or more which falls within the area of Group Housing;
(ii) the area of school (excluding sites for Nursery Schools) and other community facilities within the Group Housing Area; and
(iii) the prescribed open space (playgrounds and tot lots of local nature shall be permitted in these open spaces).
Permission for high rise buildings challenged -- Except a bald allegation that density norms have not been followed, no violation of any statutory provision shown - - Substantial question of public interest not involved in the case -- PIL dismissed. Pradeep Hinduja Vs. State of M.P. and another, 2019 (2) MPLJ 668 = 2018 Supreme 942 (MP).
(3) Side open space-
Every semi-detached and detached building shall have a permanently open airspace on sides, forming integral part of the site as below :-
(i) For detached buildings there shall be minimum side open spaces of 3 meters on both the sides :
Provided that for detached residential building up to 7 meters in height on plots with a frontage less than 12 meters, one of the sides open space may be reduced to 1.5 meters.
(ii) For semi-detached building there shall be a minimum side open space of 3.0 meters on one side. For Semi-detached building up to 10 meters in height on plots with a frontage up to 10 meters, the side open space may be reduced to 2.5 meters.
(iii) For row-type buildings, no side open space is required.
(4) Notwithstanding anything contained in sub-rule (2) and (3) garage may be permitted at rear end of the side open space.
(5) Open space for building of more than 12.5 meters height - For building of height above 12.5 meters the open spaces around building shall be as given in Table 4 and 5 of Rule 42.
(6) Interior open spaces for all buildings,-
Rule 56
79
(a) Inner Courtyard,-
(i) Every room (except bath, water closet and store room) that does not abut on either the front, rear or side open spaces shall abut on an inner courtyard, having minimum side of 3 meters.
(ii) Further the inner courtyard shall have a minimum area, throughout its height, of not less than the square of one-fifth the height of the highest wall abutting the courtyard :
Provided that when any room (excluding staircase bay, bathroom and water closet) is dependent for its light and ventilation on an inner courtyard, its dimension shall be such as is required for each wing of the building.
(iii) Where only water closet and bath room are abutting on the interior courtyard, the size of the interior courtyard shall be in line with the provision for ventilation shaft as given in clause (b).
(b) Ventilation Shaft - For ventilating the spaces for water closet and bath room in all types and height of buildings, if not opening on the front or side or rear or interior open spaces, shall open on to the ventilation shaft, the size of which shall not be less than the values given below :-
Height of buildings
Size of ventilation shaft in
Minimum size of a side of
in meters
square meters
shaft in meters
(1)
(2)
(3)
Up to 10
1.2
0.9
12.5
2.8
1.2
18
4.0
1.5
24
5.4
1.8
30
8.0
2.4
above 30
9.0
3.0
Note 1: For buildings above 30 meters mechanical ventilation system, shall be installed besides the provision of minimum ventilation shaft.
Note 2: For fully air-conditioned residential buildings the ventilation shaft need not be insisted:
Provided that the air-conditioning system is designed to work in an un-interrupted manner which means that there is an alternate source of power supply.
(c) Outer Courtyard- The minimum width of outer courtyard (distinguished from its depth) shall be 2.4 meters. If the width of the outer courtyard is less than 2.4 meters, then it shall be treated as a notch and the provisions of outer courtyard shall not apply.
Rule 57
80
Part VGeneral Building Requirements (1) Classification
Classification of Buildings.- Buildings shall be classified on the basis of occupancy as follows :-
(a) Residential.
(b) Educational.
(c) Institutional.
(d) Assembly.
(e) Business.
(f) Mercantile (including both retail and wholesale stores).
(g) Industrial (including low, moderate and high fire hazards).
(h) Storage.
(i) Hazardous.
(II) Open Spaces (within a Plot)
General.- (1) Every room intended for human habitation shall abut on an interior or exterior open space or an open verandah open to such interior or exterior open space.
Rule 56
77
(2) Open spaces to cater for lighting and ventilation requirement: The open spaces inside or around building have essentially to cater for the lighting and ventilation requirements of the rooms abutting such open spaces and in the case of building abutting streets in the front, rear or sides, the open spaces provided shall be sufficient for the future widening of such streets.
(3) Open spaces separate for each building or wing: The open spaces shall be separate or distinct for each building and where a building has two or more wings, each wing shall have separate or distinct open spaces for the purposes of light and ventilation of the wings.
(4) Separation between accessory and main buildings of more than 7 meter in height shall not be less than 1.5 meters. For buildings up to 7 meters in height no such separation shall be required.
Construction of commercial complex -- Leaving space of 4.5 meter as off-street parking and 4.5 meter as open space, these are two different requirements which are to be fulfilled and cannot be clubbed together. Satish Nayak Vs. State of M.P. and others, 2018 (2) RN 1 (HC) 2018 Supreme 292 (MP).
Residential Buildings.-Open Spaces,- Exterior open spaces for buildings having height up to 12.5 meters.
(1) Front open spaces,-
(a) Every Residential Building having height up to 12.5 meters, facing street shall have a front open space mentioned below and such open space shall form an integral part of the site :-
S.No.
Width of street facing the plot
Front open space Min.
(1)
(2)
(3)
1.
Up to 9.0 meters
3.0 meters
2.
More than 9.0 meters and up to 12 meters
3.6 meters
3.
More than 12.0 meters and up to 18 meters
4.5 meters
4.
Above 18 meters
6.0 meters
(b) In existing developed areas with streets less than 6.0 meters in width, the distances of the building (building line) shall be at 6.0 meters from the center line of the street.