- Classification of Buildings.- Buildings shall be classified on the basis of occupancy as follows :-
(a) Residential.
(b) Educational.
(c) Institutional.
(d) Assembly.
(e) Business.
(f) Mercantile (including both retail and wholesale stores).
(g) Industrial (including low, moderate and high fire hazards).
(h) Storage.
(i) Hazardous.
(II) Open Spaces (within a Plot)
- General.- (1) Every room intended for human habitation shall abut on an interior or exterior open space or an open verandah open to such interior or exterior open space.
Rule 56
77
(2) Open spaces to cater for lighting and ventilation requirement: The open spaces inside or around building have essentially to cater for the lighting and ventilation requirements of the rooms abutting such open spaces and in the case of building abutting streets in the front, rear or sides, the open spaces provided shall be sufficient for the future widening of such streets.
(3) Open spaces separate for each building or wing: The open spaces shall be separate or distinct for each building and where a building has two or more wings, each wing shall have separate or distinct open spaces for the purposes of light and ventilation of the wings.
(4) Separation between accessory and main buildings of more than 7 meter in height shall not be less than 1.5 meters. For buildings up to 7 meters in height no such separation shall be required.
Construction of commercial complex -- Leaving space of 4.5 meter as off-street parking and 4.5 meter as open space, these are two different requirements which are to be fulfilled and cannot be clubbed together. Satish Nayak Vs. State of M.P. and others, 2018 (2) RN 1 (HC) 2018 Supreme 292 (MP).
- Residential Buildings.-Open Spaces,- Exterior open spaces for buildings having height up to 12.5 meters.
(1) Front open spaces,-
(a) Every Residential Building having height up to 12.5 meters, facing street shall have a front open space mentioned below and such open space shall form an integral part of the site :-
| S.No. | Width of street facing the plot | Front open space Min. |
|---|---|---|
| (1) | (2) | (3) |
| 1. | Up to 9.0 meters | 3.0 meters |
| 2. | More than 9.0 meters and up to 12 meters | 3.6 meters |
| 3. | More than 12.0 meters and up to 18 meters | 4.5 meters |
| 4. | Above 18 meters | 6.0 meters |
(b) In existing developed areas with streets less than 6.0 meters in width, the distances of the building (building line) shall be at 6.0 meters from the center line of the street.
Rule 56
78