- Land use classification.- The land uses shall be broadly classified as indicated below :-
| S.N. | Land Use Zone | Land Use Sub-Zones | Nomenclature |
| (1) | (2) | (3) | (4) |
| 1. | Residential | Residential | (R1) |
| Residential with shop lines at Ground Floor medium density low density | (R2)(R3)(R4) | ||
| 2. | Commercial Zone | City centre | (C1) |
| Sub city centre | (C2) | ||
| Community Centre | (C3) | ||
| Local Shopping Centre | (C4) | ||
| Convenience Shopping Centre | (C5) | ||
| Mandi | (C6) | ||
| Categorized Markets | (C7) | ||
| 3. | Industrial Zone | Service Markets | (I1) |
| General Industries | (I2) | ||
| Special Industries | (I3) |
Rule 36
| 4. | Recreation | Parks | (G1) |
| Green Belts or Afforested area | (G2) | ||
| Regional Parks (Zoological or Botanical Parks) | (G3) | ||
| Preservation of Natural Areas or Landscape Areas | (G4) | ||
| Play Grounds | (G5) | ||
| Stadiums | (G6) | ||
| Lake Front Development | (G7) | ||
| Exhibition Grounds | (G8) | ||
| 5. | Public & Semi-public | Public Institutions and Administrative Area / Education and Research / Health / Social / Cultural Institutional activities | (P) |
| 6. | Special Purpose | Tourism Promotion Zone | (SP1) |
| Conservation Zone | (SP2) | ||
| Dry Port or Container Depots | (SP3) | ||
| Oil Depots or Inflammables goods Depots | (SP4) | ||
| Building Material Yards | (SP5) | ||
| Obnoxious Industries | (SP6) | ||
| SEZ | (SP7) | ||
| Mining Areas | (SP8) | ||
| Reserved Forest or National Parks or Wild Life Sanctuaries | (SP9) | ||
| Others | (SP10) |
Rule 36
| 7. | Transportation | Bus-Stands or Terminus | (T1) |
| Bus Pick-up Stations | (T2) | ||
| Roads | (T3) | ||
| Railway Stations | (T4) | ||
| Railway Lines | (T5) | ||
| Bus Depot | (T6) | ||
| Transport Nagar | (T7) | ||
| Helipads / Airport | (T8) | ||
| Metro Rail Stations | (T9) | ||
| 8. | Public Utilities and Facilities | Water Treatment Plants | (PUF1) |
| Sewerage Treatment Plant / Oxidation ponds | (PUF2) | ||
| Electric Sub-stations | (PUF3) | ||
| Trenching Grounds | (PUF4) | ||
| Trunk line Corridor Water/Sewer/Extra Voltage Electric Lines/Gas or Oil Pipe Lines and related structures | (PUF5) | ||
| Radio / TV Stations | (PUF6) | ||
| Telephone Exchange | (PUF7) | ||
| Fire Control Stations | (PUF8) | ||
| Solid waste Disposal Plants / Decomposition Plans | (PUF9) | ||
| 9. | Water bodies | River | (W1) |
| Lakes / Ponds / Reservoirs | (W2) | ||
| Nallah / Canal | (W3) | ||
| Flood affected areas | (W4) | ||
| 10. | Agriculture | Agriculture lands | (A1) |
| Village abaadi extension | (A2) |
Rule 37-38
55
- (1) Use premises permitted in land use classifications.- Subject to other provisions of this rule following Industries are permitted in Residential R 1 , R 2 Zone and Commercial Zones,-
(i) Industries listed in Part-1 Appendix-F may be allowed in Zone R l :
Provided that not more than 5 workers at a time are employed in such industry and it does not employ or use any steam, electricity, oil, water or any other mechanical power:
Provided further that the industries listed at Serial Number 1 to 38 of Appendix-F may be permitted with the use of electric power load of maximum 1.00 K.W.
(ii) Industries listed in Part I and II of Appendix-F may be allowed in R 2 . Zone:
Provided that an industry in Part II uses only electricity with a maximum load of power indicated against each and as per conditions laid down therein;
(iii) Industries listed in Part III of Appendix-F with a maximum power load of 5 K.W. may be allowed in commercial zone, in addition to industries listed in Part I and Part II.
(2) Building use and occupancies to be according to Development plan.- The various building uses and occupancies permitted in the various zones shall be as given in the development plan.
(3) Uses to be in conformity with the zone.- Where the use of building or premises is not specifically designated in the development plan, it shall be in conformity with the zone in which they fall.
(4) Uses as specifically designated in development plan.- Where the use of a site is specifically designated in the Development plan, it shall be used only for the purpose so designated.
(5) Non-conforming uses.- No plot shall be used for any use, occupancy or premises other than that are permitted under these rules or the development plan.
- Means of access.- (1) No Building to deprive any other building of means of access.- No building shall be erected so as to deprive any other building of the means of access.
(2) Building/plot to abut on a public/private means of Access.- Every building/plot shall, as far as may be possible, abut on a public/private means of access like streets/roads.
Rule 38
56
(3) Construction of building not to encroach upon an area set apart as means of access.- Every person who erects a building shall not at any time erect or cause or permit to be erected any building which in any way encroaches upon or diminishes the area set apart as means of access required under these rules.
(4) Width of means of Access:
(a) The residential plots shall abut on a public means of access like streets or road. Plots, which do not abut on a street or road, shall have access from spaces directly connected from the street or road. The minimum width for various lengths of means of access shall be as given in Table-3. No development on plots or land shall be permitted unless it is accessible by a public street of width not less than 7.5 meters. Public means of access for economically weaker sections or low-income groups shall be as mentioned in Appendix-J.
| S.No. | Width of means of access in meters | Length of means of access in meters |
|---|---|---|
| (1) | (2) | (3) |
| 1. | 7.5 | 150 |
| 2. | 9.0 | 250 |
| 3. | 12.0 | 400 |
| 4. | 18.0 | 1000 |
| 5. | 24.0 | Above 1000 |
Note: (1) The means of access shall be clear of marginal open spaces.
(2) If the development is only on one side of means of access, the prescribed width of the means of access may be reduced by 0.5 meters.
(b) Other Buildings: For all industrial buildings, theatres, cinema houses, assembly halls, stadium, educational buildings, markets other buildings which attract large crowd, the means of access shall not be less than the following:-
| Width of means of | Length of means of |
|---|---|
| access in meters | access in meters |
| (1) | (2) |
| 12.0 | 200 |
| 15.0 | 400 |
| 18.0 | 600 |
| 24.0 | above 600 |
Rule 39-40
57
(5) Pathways: The approach to the buildings from road/street or internal means of access shall, as far as may be, through paved pathway which shall not be less than 1.5 meters where the length of such pathway is not more than 30 meters.
(6) Length of means of access: Length of main means of access shall be determined by the distance from the farthest plot (building) to the public street. The length of the subsidiary access way shall be measured from the point of its origin to the next wider road on which it meets.
(7) Authority may require larger width of means of access in general interest. In the interest of general development of an area, the Authority may require the means of access to be of larger width than that required under sub-rule (4).
(8) Boundary of plots in existing built up area to be shifted with reference to control line of street. In areas which are already built up and where the plots face street/means of access less than 4.5 meters in width, the plot boundary shall be shifted from the central line of the street/means of access so as to ensure that the street/means of access achieves a width of 4.5 meters.
- Leveling etc. of means of access.- (1) Means of access shall be levelled, metalled, flagged, paved, sewered, drained, channelled, lighted, laid with water supply line and provided with trees for shade to the satisfaction of the Authority. It should be free of encroachment by any structure or fixture so as not to reduce its width below the minimum requirement under sub-rule (4) of rule 38 and shall be maintained to the satisfaction of the Authority
(2) If any private street or any other means of access to a building is not levelled, metalled, flagged or paved, sewered, drained, channeled, lighted or laid with water supply line or provided with trees for shade to the satisfaction of the Authority, it may by written notice require the owner or applicant or occupier of the premises situated in front of or adjoining the said street or other means of access or abutting thereon or to which access is obtained through such street or other means of access to fulfil the aforesaid requirements in such manner, as directed.
(3) If any structure or fixture is set upon a means of access reducing its width below the minimum required, the Authority may remove or cause it to be removed further and recover the expenses so incurred from the owner or owners or occupier.
- Access from Highways/Important Roads.- No premises other than highway amenities like fuel pumps, motels shall have an access direct from highways and such other roads as may be specified, from time to time, by the Authority. The portion of such roads on which direct access may be permitted shall be as identified in the development plan. However, this clause shall not be applicable in case of existing development on highways/other roads referred above. These provisions shall however be subject to the
Rule 41-42
58
provisions of the Madhya Pradesh Highway Act, 1936 (XXXIV of 1936) and National Highway Act, 1956 (48 of 1956).
- Additional provisions for buildings other than residential buildings.- For building other than residential buildings the following additional provisions of means of access shall be ensured :-
(a) the width of the main street, on which the building abuts shall not be less than 12 meters and one end of this street shall join another street of width not less than 12 meters;
(b) the approach to the building and open spaces on its sides shall be hard surfaced capable of taking the weight of fire engine. The side open space shall be kept free of obstructions and shall be motor-able;
(c) main entrance to the plot shall be of adequate width to allow easy access to the fire engine and in no case it shall measure less than 4.5 meters. The entrance gate shall fold back against the compound wall of the premises leaving the exterior access way within the plot free for movement of fire service vehicles. If main entrance at boundary wall is built over, the minimum clearance shall be 4.5 meters.
- Additional provisions for buildings with height above 12.5 meters.- (1) Planning Norms for the buildings having height above 12.5 meters and up to 30 meters shall be as given in Table No 4.
TABLE No. 4
[See Rule 42(1)]
12.5 M AND UPTO 30 M IS PROPOSED:
| S. No. | Road Width in meters | Minimum plot/land (area in sq.m.) | Frontage in meters | FAR | <sup>1</sup>[GroundCoverage per-centage | Building Height in meters | Front M.O.S. in meters | Sides/ rear in MOS in meters |
|---|---|---|---|---|---|---|---|---|
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| 1. | 12.0 m. and above | 1000 sq. m. | 18 m. | 1:1.50 | - | Up to 18 meters | 7.5 | 6.0 |
| 2. | 18 m. & above | 1500 sq. m. | 21 m. | 1:1.75 | - | Up to 24 meters | 9.0 | 6.0 |
| 3. | 24 m. & above | 2000 sq. m. | 30 m. | 1:2.0 | -] | Up to 30 meters | 12.00m. | 7.5 m. |
Note: [*Deleted*]
In Rule 42, Column no. 6 and Note (1) of Table 4 of sub-rule (1) deleted by MP Rajpatra (Asadharan) No. 74 dated 06-03-2025 at page 147-148(5).
Rule 42
59
(2) For High Rise Buildings as defined in rule 2(38). For high rise building Planning Norms shall be as given in Table No 5.
TABLE No. 5
[See Rule 42(2) above]
DEVELOPMENT NORMS FOR PLOTS / LANDS ON WHICH HIGH RISE BUILDING(S) IS PROPOSED
| S. No. | Road Width | Minimum plot/land size (area in sq.m.) | Frontage in meters | FAR | Ground Coverage per-centage | Building Height in meters | M.O.S. Front side in meters | MOS Sides/ rear |
|---|---|---|---|---|---|---|---|---|
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| 1. | 30 m. and above | 2500 | 30 m. | 1:2.25 | 30 | Up to 45 meters | 15.00 m. | 7.5 m. |
| 2. | 36 m. and above | 3000 | 40 m. | 1:2.50 | 30 | Up to 60 meters | 18.00 m. | 9.0 m. |
| 3. | 45 m. and above | 3500 | 45 m. | 1:2.75 | 30 | Up to 75 meters | 21 m. | 9 m. |
| 4. | 60 m. and above | 4000 | 50 m. | 1:3.0 | 30 | Up to 90 meters | 24.00 | 10 m. |
| 5. | 75 m. and above | 4500 | 60 m. | 1:3.0 | 30 | Above90meters | 30.00 | 12 m. |
1[Note:
-
In commercial use premises of planning areas, the authority may allow maximum FAR of 1:5.0 through utilization of TDR FAR and Premium FAR for serial no. 4 and 5 mentioned in above table.
-
In commercial use premises under Central Business District and Transit Oriented Development Corridor, the authority may allow maximum FAR of 1:7.0 through utilization of TDR FAR and Premium FAR for serial no. 5 mentioned in above table. Central Business District and Transit Oriented Development Corridor shall be as mentioned in respective development plan.
-
The rate of premium FAR shall be as may be decided by the State Government.]
1Inserted by Notification No. F. UDH-3/0002/18-5/2024 dated 06th March 2025.
Published in M.P. Rajpatra (Asadharan) S.N. 72 dated 06th March 2025 at pages 143-144(1).
Rule 42
60
(3) For building having height more than 12.5 meters the necessary drawings and details shall be submitted to the Authority incorporating all the fire fighting measures recommended in National Building Code Part-IV. The occupancy permit shall be issued only after ensuring that all fire fighting measures are physically in place.
(4) For all high rise buildings site clearance from Site clearance committee under sub-rule (2) of Rule 12 shall be necessary. After site clearance by the committee, planning permission from the Town and Country Planning and building permission from the Authority shall be necessary.
(5) The approach to the building and open spaces on its all sides shall be as hard as is required to bear the weight of fire engine. The said open space shall be kept free of obstruction and shall be motor-able.
(6) Main entrance to the plot shall be of adequate width to allow easy access to the fire engine and in no case it shall measure less than 4.5 meters. The entrance gate shall fold back against the compound wall of the premises, thus leaving the exterior access way within the plot free for movement of fire service vehicles. If the main entrance at the boundary wall is built over, the minimum clearance shall be 4.5 meters,
1[42A. Norms for Information Technology.- Information Technology (IT), Information Technology Enables Services (ITES) and Electronic System Design and Manufacturing shall be called Information Technology.
(1) Land required for plot :- Minimum area of plot shall be 3000 sq.m.
(2) Information Technology (Investment) Planning Area :- Such area shall be termed as Information Technology Investment Area which bears a minimum area of 2 Hectare (5 acre) and such area which shall be notified by Science and Technology Department, Madhya Pradesh Government.
(3) Floor Area Ratio (FAR):- Plots for Information and Technology, and in Information and Technology Investment Area shall have maximum FAR of 1:2.50 or maximum FAR permissible in the relevant development plan, whichever is higher :
Provided that if the plot/building situated in the Information Technology Investment Area is being used for non IT purposes in excess of the percentage
Ins. by Notification No. F-3-48/2017/18-5, dated 13th December, 2017. Published in M.P. Rajpatra Part 4(Ga) dated 22nd December, 2017 at pages 666-667.
Rule 43-45
61
mentioned in the following table-5 A, then the FAR and land use of whole plot/building shall be accepted as per the relevant development plan.
TABLE 5-A
[See Rule 42(a)]
Percentage of Plots/Building under MPIT, ITES and ESDM
| S. No. | Type of application | Type of Development | Percentage of Plots/F.A.R. | |
| Plots used Minimum IT/ ITES/ESDM | Plots used Maximum Ancillary/ Commercial other Industry/ Residential | |||
| 1. | IT unit/ITES/Unit | Plotted Development | 85% | 15% |
| IT unit/ITES | Building Construction | 60% | 40% | |
| 2. | ESDM Units | Plotted Development | 85% | 15% |
| 3. | Developers of an IT Investment Area | Building Construction | 85% | 15% |
| Developers of an IT Investment Area | Building Construction | 60% | 40%] | |
-
Cul-De-Sacs.- Cul-de-sacs giving access to plots will be allowed provided that cul-de-sacs would be permissible only on straight roads and the turning space shall not be less than 121 square meters in area with no dimension being less than 11 meters.
-
Alley.- Alley may be provided where required. The width of the alley where provided shall not be less than 3 meters and no dead end alley shall be permitted unless provided with an adequate turn around facilities.
-
Intersection of roads.- (1) The layout for junctions of roads shall be in such a way that as far as possible all roads meet at right angle. Roads meeting at less than 30° should be avoided.
(2) For junctions of roads meeting at right angles or otherwise the rounding off or cut off or splay or similar treatment shall be done to the satisfaction of the Authority, depending upon the width of roads, the traffic generated, the sighting angle etc.
Rule 46-47
62
-
Building Line.- Subject to rule 56, building line shall be set back at least 3 meters from means of access.
-
Community Open Spaces and Amenities.- (1) The community open spaces shall be as follows :-
(a) Commercial Zones: In any layout or sub-division of land measuring 0.2 hectare or more and situated in commercial zones, the community open spaces shall be reserved for recreational purposes. Such space shall as far as possible, be provided in one place or may be planned out in clusters or pockets for the use of the community.
(b) Community Open Spaces in Residential Zones: In any Residential layout of plotted development or sub-division of land, Group Housing or Apartment Housing the community open spaces shall be reserved for recreational purposes. As far as possible these community open spaces shall be provided in one place or planned out in clusters or pockets, for the use of the community:
Provided that the minimum open spaces required may be notified by the State Government in the official Gazette and the same shall not be less than as mentioned in sub-rule (2) below.
(2) Minimum open area: The minimum community open spaces shall be,-
(i) 10 per cent. of the area of the layout; and
(ii) in case of economically weaker sections and low income group as prescribed in Appendix-J.
(3) Minimum average dimension of recreational space: The length of such area shall generally not exceed two and half times of the average width. However, depending on the configuration of the site, common open spaces of different shapes may be permitted by the Authority as long as the open spaces provided, serve the needs of the immediate community contiguous to the open spaces.
(4) Pavilion gymnasia: In such recreational spaces, a single storied structure up to 25 square meters of built up area, which may be used as pavilion or gymnasia, may be permitted. Such area may be excluded from floor area ratio calculations. Where the area of the open space exceeds 2000 sq. mtrs. in one place, the built up area of such gymnasia may extend upto 75 sq. mtrs..
(5) Independent means of access: Each recreational area and the structure on it shall have an independent means of access. Independent means of access may not be insisted if recreational space is approachable directly from every building in the layout. Further the building line shall be at least 3 meters away from the boundary of recreational open space.
Rule 48
63
- Industrial Zones.- (1) Amenity open space in Industrial use: In every industrial zone, 5 per cent of the total area shall be reserved as open space. These open space may be used for parking, banking, canteens, welfare centers and such other common purposes as approved by the Authority.
(2) Open space in Industrial plots: In industrial plots measuring 1000 square meters or more, 10 percent of the total area shall be provided as an amenity open space. Such an amenity open space shall have a means of access and shall be so located that it would be conveniently utilised by the persons working in the industry.
(3) Development norms for Industrial plot shall be as follows :-
Norm for Industrial Plots
| Sr. No. | Minimum Plot Area | Max. Ground Coverage in % | Minimum MOS in meters | Max. Floor Area Ratio (FAR) | ||
| Front | Side/Side | Rear | ||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
| 1. | Upto 0.045 Hect. | 60 | 3.20 | 2.10/2.10 | 2.10 | 1.25 |
| 2. | More than 0.045 Hect. and upto 0.10 Hect. | 60 | 4.50 | 3.00/3.00 | 3.00 | 1.25 |
| 3. | More than 0.10 Hect. and upto 0.20 Hect. | 60 | 7.50 | 3.75/3.75 | 4.50 | 1.00 |
| 4. | More than 0.20 Hect. and upto 0.50 Hect. | 60 | 9.00 | 4.50/4.50 | 4.50 | 1.00 |
| 5. | More than 0.50 Hect. and upto 0.75 Hect. | 60 | 12.0 | 6.00/6.00 | 6.00 | 1.00 |
| 6. | More than 0.75 Hect. and upto 1.00 Hect. | 60 | 15 | 7.50/7.50 | 7.50 | 1.00 |
| 7. | More than 1.00 Hect. and upto 1.25 Hect. | 60 | 18 | 9.00/9.00 | 9.00 | 1.00 |
| 8. | More than 1.25 Hect. and upto 2.00 Hect. | 60 | 21 | 10.50/10.50 | 10.50 | 1.00 |
| 9. | More than 2.00 Hect. | 60 | 24 | 12.00/12.00 | 12.00 | 1.00 |
| For Flatted Industries | ||||||
| 1[10. | Minimum Plot Area 1500 Sq.m. (0.15 Hect.) | 50 | 12.00 | 6.00/6.00 | 6.00 | 2.00] |
1 Subs. by Notification No. F. UDH-3/0002/18-5/2024 dated 06th March 2025. Published in M.P. Rajpatra (Asadharan) S.N. 72 dated 06th March 2025 at pages 144-144(1).
Rule 48
64