A water storage tank shall be dug on marginal open Space of building so that rain water drains into the tank, and a tap at appropriate place shall be inserted for extraction of water from the tank and circulation of air. Stored water in the tank shall be used for house hold use such as waning clothes, floor sweeping and gardening.
For waste water of premises of 100 dwelling units a storage tank stall be dug as per proposal of Authority in marginal open space of building and on that tank a sewerage treatment plant shall be installed so that treated water can be used in gardening and plantation.
1
Design
Comments
Design / Drawings available?
Y/N
Design Category
Type Design?
Y/N
Specific Design
Design to be collected to refer to Design Consultant /H.O.
Drawing prepared/checked by competent Authority?
Y/ N
Design Drawing/details
Y/ N
Structural details included
Y/ N
Earthquake/cyclone resistant features Included?
Y/ N
Design verified/vetted by Dept./Govt. approved agency/competent authority?
Y/N
Design changes approved by Dept./Govt. approved agency/competent authority
Y/N
2
Foundation
(2.1) Foundation used
Existing/ New
(2.2.1) If existing foundation used
(2.2.1) Depth of foundation below ground
: <50 cm @ 50-70/> 70cm
(22.2) Type of masonry
: Stone / Bncks / PCC Blocks
(2.2.3) Thickness of masonry (above ground)
: 23cin /35 />35
(2.2.4) Mortar used
Cement - Sand
(2.2.5) Mix of cement mortar
As per NBC Indicate
(2.2.6)Height up to Plinth
_______ Mtr. As per GDCR Y/N
(2.2.7) If stone masonry
(2.2.7.1) Through Stones
Yes / No. If Yes Adequate/Inadequate
(22.7.2) Corner Stones
Yes / No. If Yes Adequate/Inadequate
(2.3) If a new foundation used
(2.3.1) Depth of foundation below ground
<50/50-70/>70 cm
(2.32) Type of masonry blocks
Stone / bricks / PCC
(2.3.3) Thickness of Masonry above plinth -
23cm/35/>35cm
(2.3.4) Mortar used •
Cement-sand / lime / mud
(2.3.5) Mix of cement mortar (1:4)/As Per NBC
Yes/No
(2.3.6)Height up to plinth
________Mtr, As per GDCR Y/N
(2.3.7)If stone masonry
(2.3.7.1) Through Stones
Yes / No. If Yes Adequate/Inadequate
(2.3.7.2) Comer Stones
Yes / No. If Yes Adequate/Inadequate
(2.4) Vertical reinforcement in foundation
: Yes ./ No
3
Walling
(3.1) Type of masonry
: Stone/ Brick / PCC Blocks
(32) Mortar used
: Cement- sand / Lime / Mud
(3.3) Mix of cement mortar
: 1:4 /1:1.6/Leaner
(3.4) Thickness of wall
: >23cm/23cm/23cm
(3.5) Mixing of mortar
: OK /Not OK
(3.6) Join property filled
: OK /Not OK
(3.7) Wetting of bricks
: Good / Medium / Poor
(3.8) 1 stone masonry
(3.8.1) Through Stones
: Yes/No
(3.82) Corner Stones
: Yes / No
(3.9) Overall workmanship
Good / Medium / Poor
4
Roofing
(4.1) Type of roof
: Flat / Sloping
(4.2) If sloped
: Morbid tiles / AC. sheet / G.I. sheet
(4.3) Purlins
: Angle-
Iron / Timber / NA
(4.4) Truss type
(4.5) Anchorage with wall
: Adequate / Inadequate / NA
5
Materials
: Specifications must be conforming to NBC/Relevant IS Codes
(5.1) Cement
(5.1.1)Source
Authorised Dealer / Market OPC/PPC/ PSC
(5.1.2) Type of cement
Grade (33 / 43 / 53)
(5.1.3) If OPC
OPC / PPC/ PSC
(5.2) Sand
(5.2.1) Type of sand
Mild / Moderate / High
(5.2.2) Presence of deleterious
materials
(5.3) Coarse Aggregates
(5.3.1) Type coarse Aggregates
Gravel / Crushed Stone
(5.3.2) Presence of deleterious material
Mild / Moderate / High
(5.4) P.C.C. Blocks (Applicable for onsite
production)
(5.4.1) Type of P.C.C. Blocks
Solid blocks/Hollow blocks
(5.42) Ratio of concrete in block
(5.4..3) Interlocking feature
Yes / No
(5.4.4) Course aggregates used
Natural / Crushed stone
(5.5) Bricks Blocks, Stone etc.
(5.5.1) Strength (field assessment)
Low / Medium / High
(5.52) Dimensional accuracy
Yes / No
(5.6) Concrete
(5.6.1) Mix of concrete
(1:1 1/2:3)/(1:2:4)/ Design Mix
(5.62) Batching
Weight batching/ Volume batch ing
(5.6.3) Compaction
Vibrators / Thappies and rods
(5.6.4) Workability
Low / Medium / High
(5.6.5) Availability of water
Sufficient / Insufficient
(5.6.6) Curing
Satisfactory/ unsatisfactory
(5.7) Reinforcing Steel
(5.7.1) Type of Steel
Plain mild steel HYSD bars
(5.72) Source
Authorised Dealer /Market
(5.7.3) Whether IS Marked
Yes/No
(5.7.4) Conditions of bars
Clean / Corrugated
(5.7.5) Fixing of reinforcement as per
Yes / No
drawing
(5.7.6) Suitable cover
Yes/No
(5.7.7) Spacing of bars
Regular / Irregular
(5.7.8) Overlaps as per specifications
Yes / No
(5.8) Form work
Timber/ Play board /Steet
(5.8.1) Type of form work
Forms
Form 1: Application for Registering as Person on Record
(Regulation No. 3.1.1)
To
The Chief Executive Authority / Municipal Commissioner/Chief Officer
Urban Development Authority / Municipal Corporation/ Area Development Authority/ Nagarpalika
Name:
Local Address:
Permanent Address:
Telephone / Fax No:
Qualification:
Membership of Professional:
Associations (indicate appropriate professional affiliations)
Experience (No. of years):
Previous year’s Registration: _ No.
Name of Employer:
(if employed)
Sir/Mm,
Kindly register me as (Architect on Record/Engineer on Record/Structural Engineer on Record/Clerk of Works on Record/ FPCOR/ SOR/ Developer) of the Competent Authority. I meet with the minimum qualifications and competence requirements as specified in Regulation No. 3.0 and schedule 7.0. Relevant documents attesting to the same are attached herewith.
I hereby undertake to abide by all rules, regulations, standing orders, requisitions and instructions given by the Competent Authority and shall carry out my responsibilities as prescribed in the General Development Control Regulations. I also understand that if I fail to perform my responsibilities as above, the Competent Authority reserves the right to de‐register me, forfeit my security deposit and take other appropriate action as defined in the General Development Control Regulations and as per the provisions of the Act.
Name of the Applicant:
Signature:
Date:
Form 2A: Certificate of Undertaking for Persons on Record
(See Regulation No. 3.4,3.5.1, 3.5.2, 3.5.3,3.5.6, 3.6.1and Schedule 4a, 4b, 4c and Regulation No. 24.7 with Schedule 4a)
To
The Chief Executive Authority / Municipal Commissioner/Chief Officer Urban Development Authority / Municipal Corporation/Area Development Authority/Nagarpalika
Proposed building:
(Title of the work)
Plot No.:
Area of the Plot:
Survey No.: City Survey No.:
Inward No.: Final Plot No.:
Sub Plot / Property No.: at Village:
Address of proposed building:
Name of the Owner / Developer:
Sir/Mm,
I , am currently registered as Architect on Record with the Competent Authority. I, hereby certify that I am appointed as the Architect on Record to prepare the plans, ,sections and details as required under the Development Regulations for the above mentioned project and that I have prepared and signed the same and that the execution of the project shall be carried out under my direction and supervision of supervisor or owner, as per the approved drawings. I am fully conversant with the provisions of the Regulations, which are in force, and about my duties and responsibilities under the same and I undertake to fulfill them in all respects, except under the circumstances of natural calamities.
I, is currently registered as Engineer on Record with the Competent Authority.
I, hereby certify that I am appointed as the Engineer on Record to prepare the plans, sections and details as required under the G e n e r a l Development Control Regulations for the above mentioned project and that I have prepared and signed the same and that the execution of the project shall be carried out under my
direction and supervision of supervisor or owner, as per the approved drawings. I am fully conversant with the provisions of the Regulations, which are in force, and about my duties and responsibilities under the same and I undertake to fulfill them in all respects, except under the circumstances of natural calamities.
I is currently registered as Structural Engineer on Record with the Competent Authority as per Regulation No. 3.4, 3.5.3and Schedule 4a, 4b, 4c
This is to certify that I, is appointed as the Structural Engineer on Record to prepare the structural report, structural details and structural drawings for the above mentioned project. I am fully conversant with the Regulations and of my duties and responsibilities under the Regulations and assure that I shall fulfill them in all respects. I have prepared and signed the structural design and drawings of the proposed building as per the prevailing Indian Standard Specifications and further certify its structural safety and stability in design.
I, is currently registered as Clerk of Works on Record with the Competent Authority as per Regulation No. 3.4, 3.5.3and Schedule 4a, 4b, 4c
This is to certify that I, is am appointed as the Clerk of Works on Record for the above mentioned project. I, am fully aware of my duties and responsibilities under the Regulations and assure that I shall fulfill them in all respects. . I shall undertake all necessary measures, including but not limited to adequate inspection during construction, to ensure that the construction of the building is undertaken in accordance with the detailed design and specifications provided by (name of the Architect on Record) and (name of the Structural Engineer on Record), and, with the sanctioned design and specifications.
• I undertake not to supervise more than ten works at a given time as provided in Development Regulations.
I undertake not to supervise work simultaneously at one point of time on any other sites during my supervision of the execution of this work.
I fully understand that in case my certificate is found to be false, or if it is found that I have not fulfilled my responsibilities as prescribed therein, the Competent Authority shall be at liberty to penalize me as per the provisions of the Act.
I, is am currently registered as Fire Protection Consultant on Record with the Chief Fire Officer.and as per Regulation No. 3.4, 3.5.4 and Schedule 4a, 4b, 4c
I, is hereby certify that I have been appointed as the Fire Protection Consultant on Record of the proposed building.I am fully conversant with the Regulations and of my duties and responsibilities under the Regulations and assure that I shall fulfill them in all respects. I have prepared and signed the fire safety drawings of the proposed building as per the Regulations and further certify its fire safety.
I, is fully understand that in case my certificate is found to be false, or if it is found that I have not fulfilled my responsibilities as prescribed therein, the Competent Authority shall be at liberty to penalize me as per the provisions of the Act.
I, is currently registered as supervisor of Works on Record with the Competent Authority per regulation No. 3.4a, 3.5.4a and Schedule 4a, 4b, 4c
This is to certify that I am appointed as the supervisor of Works on Record for the above mentioned project. I am fully aware of my duties and responsibilities under the Regulations and assure that I shall fulfill them in all respects. . I shall undertake all necessary measures, including but not limited to adequate inspection during construction, to ensure that the construction of the building is undertaken in accordance with the detailed design and specifications provided by
(name of the Architect on Record) and (name of the Structural Engineer on Record), and, with the sanctioned design and specifications.
• I undertake not to supervise more than ten works at a given time as provided in Development Regulations.
• I undertake not to supervise work simultaneously at one point of time on any other sites during my supervision of the execution of this work.
I fully understand that in case my certificate is found to be false, or if it is found that I have not fulfilled my responsibilities as prescribed therein, the Competent Authority shall be at liberty to penalize me as per the provisions of the Act.
As per Regulation No. 24.7 and Schedule 4a of this Comprehensive General Development Control Regulations we all undersigned except Fire Protection Consultant on Record
1.Certified that the building plans submitted for approval satisfy the safety requirements as stipulated under Building Regulation No. and the information given therein is factually correct to the best of our knowledge and understanding.
2.It is also certified that the structural design including safety from hazards based on soil conditions shall be duly incorporated in the design of the building and these provisions shall be adhered to during the construction
Name of EOR
Registration No.:
Address:
Tel. No.: Signature: Date:
Name of SEOR:
Registration No.:
Address:
Tel. No.:
Signature:
Date:
Name of Clerk of Works:
Registration No.:
Address:
Tel. No.: Signature:
Date:
Name of FPCoR:
Registration No.:
Address:
Tel. No.: Signature: Date:
Signature of Owner with date
Name
Address
Tele No.
SPECIAL BUILDING INFORMATION SCHEDULE (TO BE ANNEXED WITH FORM 2D) (In case of small houses of one or two storeyed load bearing masonry construction)
1 Building address
Sub-Plot
RSNo/F PNo/
TPScheme Name/No.
Town:
Taluka:
District
Reference
2 Building category
2.1 Type of Construction
Brick masonry or other rectangular units
Dressed stone masonry
RCR masonry
3 Location
3.1 Seismic zone
V
IV
III
Table : 1
3.2 Design intensity (MM/MSK)
IX
VIII
VII
Table : 1
3.3 Cyclone zone
20%
40%
50%
60%
75%
80%
100%
4 Foundation
4.1 Soil type at site (Note 2)
Rocky/Stiff
Medium
Soct/Black Cotton Soil
Liquefiable Ref.(1)
4.2 Depth of water
In Meter:____
4.3Type of footing/ Foundation used
Strip with or without sand bed
Individual column
Under- room
*Any other (specify)
5 Super-structure
5.1 Storeys etc.
Basements:0/1
G.F:
1st Floor
2nd
Water tank on roof
5.2. Mortar
C:S = 1:4
C:L:S -1:1:6
*Any other
5.3 Floors
RC slabs
Stone slabs
Prefab floori
*Any other (specify)
5.4 Roof
Flat like floors/ Sloning
Trussed/raftered/'A' frame/Sloning RC
* Any other
5.5 Roof covering
CGI sheeting
AC sheets
Morbitiles
* Any other
6 Safet
6.1 Bra
In pl
In plane of
In plane of vertical columnsYes/No/NA
Cyclone guideline
6.2 Ro
To walls=byBolt : length=_cm
Cyclone guideli
6.3 Co
Connecting to Purlins
Purlins to raftersBolt/Wire
Truss elements
Cyclone guideline
7 Load be a ri
7.1 On
Control used on sizes
Control used on location
Strengthen ing
GSDMA guideline
7.2 Ban
Plinth
Lint el
Eave ban
Roof
Gable
Ridge
Construction
7.3 Ver tica
At corners of roomsYes/No/NA
At Jambs of openingsYes/No/NA
Constructi
7.4 Stif fen
RC screed & bandYes/No/NA
Peripheral band and
Diagonal planks and
Constructi
g N NofrsNote: You have to encircle appropriate data/fact or
wA AfloYes/No/NGive relevant fact/data where option is not given or
orsSpecify particular fact/data where options are not applicable in your case.
bui.5,roofClauRef: 1. Guidelines for reconstruction and new construction of houses in Kachchh l18wse:earthquake affected areas of Gujarat ‐ Gujarat State Disaster Management Authority, dGovt. of hGujarat ‐ June, 2001.
is.4,2. Guidelines for cyclone resistant construction of buildings in Gujarat ‐ Gujarat State epaDisaster Management Authority, Govt. of Gujarat ‐ December, 2001