(Refer Regulation No.3.5.5, 5.1.3, 6.1.3, 6.1.4, 6.2.2) sSchedule 4a and As per Competent authority respective Regulation)
If any criteria mentioned under differ from Fire Prevention & Life Safety Measures Regulations - 2016 in such cases Fire Prevention and Life Safety Measures Act – 2013 and rules -2014 , regulations – 2016 made their under prevails
| Building Use | Criteria | Fire Protection | Chief Fire Officer's |
| All uses | Building Height > 45mts | RCeoqnusiureltdant | ReqOupiriendion |
| Residential | Building Height > 15mts | Required | May not be required |
| Building Height > 25mts | Required | Required | |
| Mixed-Use or Business | Building Height >15mts | Required | Required |
| Hospitality, Educational, Institutional, Mercantile | Building Height >12mts to 25mts | Required | Required |
| Building Height > 25mts | Required | Required | |
| Special Building, Storage Building, Wholesale | Building Height > 12mts | Required | Required |
| Total Built Up Area up to 5,000 sq.mt | Required | Required | |
| Total Built Up Area > 5,000 sq.mt | Required | Required | |
| Ligmhatrket Industrial, General Industrial | Total Built Up Area up to 2,000 sq.mt | Required | May not be required |
| Total Built Up Area >2,000 sq.mt and up to 5,000 | Required | Required | |
| Tostqa.lmBtuilt Up Area > 5,000 sq.mt | Required | Required | |
| Hazardous, Special Industrial | Total Built Up Area up to 500 sq.mt | Required | Required |
| Total Built Up Area > 500 | Required | Required | |
| Religious Building | Tostqa.lmBtuilt Up Area > 2,000 sq.mt | Required | Required |
| Fuelling Station | All Buildings | Required | Required |