(i) In rule 50 of the Principal Rules, the expression "In ULB the building height shall not normally be more than 14.50 meters (fourteen and half). But in the case of any building exceeding 14.50 meters in height, the ULB" shall be substituted with the expression "In the case of any building exceeding 18 meters in height, the ULB / Tripura Urban Planning & Development Authority, as the case may be" and the expression "In such cases" shall be substituted with the expression "For the buildings having height more than 14.50 meters (fourteen and half)";
(ii) In clause (1) of rule 50 of the Principal Rules, the expression "15.00 meters in width" shall be substituted with the expression "10.00 (ten) meters in width including drains";
(iii) Clause (2) of rule 50 of the Principal Rules shall be substituted with the following-
"(2) every building exceeding 14.5 (fourteen and half) meters in height shall have a minimum front open space at ground level (open to the sky without any cantilever projection excepting chajja or weather shades of not more than 0.50 metre width) as indicated below:-
| Height of building (meters) | Minimum front open space at ground level at its narrowest part (meters) |
|---|---|
| Above 14.50 but not more than 25.00 | 3.00 |
| Above 25.00 | 5.00 |
(iv) Clause (3) of rule 50 of the Principal Rules shall be substituted with the following
"(3) every building exceeding 14.5 (fourteen and half) meters in height shall have a minimum rear open space at ground level (open to the sky without any cantilever projection excepting chajja or weather shades of not more than 0.50 metre width) as indicated below."
| Height of building (meters) | Minimum rear open space at its narrowest part (meters) |
|---|---|
| Above 14.50 but not more than 18.00 | 3.50 |
| Above 18.00 but not more than 30.00 | 5.00 |
| Above 30.00 | 10.00 |
Provided that, if horizontal distance of any part of the building is more than 30 meters from the approach road of not less than 10 meters in width then minimum rear open space at its narrowest part should be 10.00 meters irrespective of the height of the building.
Provided further that, the rear open space shall be of harc surface capable to take load of fire engine weighting upto 45 tonnes."
(v) Clause (4) of rule 50 of the Principal Rules shall be substituted with the following-
"(4) every building exceeding 14.5 (fourteen and half) meters in height shall have a minimum side open space at ground level (open to the sky without any cantilever projection excepting chajja or weather shades of not more than 0.50 metre width) as indicated below:-
| Height of building (meters) | Minimum side open space at its narrowest part (meters) | |
| Side 1 | Side 2 | |
| Above 14.50 but not more than 30.00 | 3.50 | 3.50 |
| Above 30.00 | 5.00 | 5.00 |
Provided that, minimum side open space should be such that the appropriate fire engine can move freely around the building in case of necessity. Appropriate Turning radius should also be maintained in all corner of the building for this purpose.
Provided further that, the side open space shall be of hard surface capable to take load of fire engine weighting upto 45 tonnes "
(vi) sub-clause (a) of clause (6) of rule 50 of the Principal Rules shall be substituted with the following-
"(6)(a) For a building exceeding 14.5 (fourteen and half) meters in height, the Floor Area Ratio (FAR) shall be 3;
Provided that, the applicant may get the Floor Area Ratio (FAR) increased from the authority competent to approve it, on payment of a fee for additional Floor Area Ratio (FAR) beyond 3 upto 5, at such rates as determined by the authority competent to approve subject to minimum as may be determined by State Government from time to time.
Provided further that, for relaxation of Floor Area Ratio (FAR) beyond 5, approval of State Government shall be necessary and on payment of a fee for additional Floor Area Ratio (FAR) beyond 5, at such rates as may be determined by State Government from time to time"
(vii) sub-clause (b) of clause (6) of rule 50 of the Principal Rules, the expression "rule 50", shall mean and construe as "rule 49".
- Amendment of Rule 51: Sub-rule (2) of rule 51 of the Principal Rules shall be substituted with the following-
"(2) Ground Coverage shall be as laid down below." The maximum permissible ground coverage for a building of any type of uses shall not be more than 70%."
- Amendment of Rule 52: Sub-rule (2) of rule 52 of the Principal Rules shall be substituted with the following-
"(2) In the case of existing building." (a) Except the storage buildings, where the open spaces required have not been provided an addition of one storey, if otherwise permissible, may be allowed with the already approved set back, provided such building continues with the same occupancy; Provided that the existing building is in conformity with the already approved plan; Provided further that the structural stability is certified by the authorized technical persons based on structural record on the approved plan and constructed building condition.
condition. (b) if any car parking space is required to be provided under these rules and no such car parking space can be provided in such existing building, the covered area allowable under the provisions of these rules shall be reduced by the area required for such car parking space which can not be provided in the said building; Explanation.- For the purpose of calculation, the area required for one car parking space shall be taken as 20.00 sq. meters.
shall be taken as 20.00 sq. meters. (c) the height of the building shall conform to the rules as indicated in rule 45 and 47 and in no case after addition the height shall exceed 14.5 meters;
and in no case after addition the height shall exceed 14.5 meters! (e) the ground coverage of the building shall conform to the rules as indicated in rule 46."
- Amendment of Rule 53: (i) ) In rule 53 of the Principal Rules, the expression "or is older than 50 (fifty) years" shall be deleted.
years" shall be deleted. (ii) In rule 53 of the Principal Rules, the following proviso shall be added-
“Provided that the owner of all such buildings, without provisions of seismic considerations, must retrofit their buildings with the help of expert agency, firm, Architect or Engineer, empanelled by the ULB or Authority, for this purpose and obtain a safety certificate after necessary structural improvement, if needed. The ULB or Authority will empanel expert agency, firm, Architect, Engineer for this purpose.”
- Amendment of Rule 105: In rule 105 of the Principal Rules, after sub-rule (3), a now sub-rule (4) of shall be added as follows-
"(4) The State Government may by Notification, to be published in official gazette, prescribe separate Green Rating systems for buildings by selectively combining, adopting and or amending the provisions from the following guidelines—
adopting and or amending the provisions from the following guidelines: * Indian Green Building Council (IGBC) guidelines by the Confederation of Indian Industries, and or
of Indian Industries, and or * Green Building for Integrated Habitat Assessment (GRIHA) guidelines by the Ministry of New and Renewable Energy, Government of India, and or
Tripura Gazette, Extraordinary Issue, February 25, 2019 A. D.
* Energy Conservation Building Code (ECBE) guidelines prepared by Bureau of Energy Efficiency, Ministry of Power, Government of India, and or
* Model Energy Efficiency guidelines, and or any other guidelines, time to time prescribed by Government of India or any State Government."