(i) Sub-rule (2) of rule 48 of the Principal Rules shall be substituted with the following-
"(2) The minimum front open spaces shall be as follows:-"
Every building shall have a minimum front open space at ground level (open to the sky without any cantilever projection excepting chajja or weather shades of not more than 0.50 meter width) of a width at its narrowest part of not less than that indicated below-
| Use of building | Height of building (metres) | Minimum front open space at ground level at its narrowest part (metres) |
|---|---|---|
| Residential | Upto 14.50 | 1.80 |
| Commercial having built up area upto 100 sqm. | Upto 14.50 | 1.80 |
| Commercial having built up area more than 100 sqm. | Upto 14.50 | 3.00 |
| Assembly/ Institutional/Educational/ Club | Upto 14.50 | 3.00 |
| Industrial/ Mercantile (Wholesale)/Storage | Upto 14.50 | 3.00 |
| Others not specified above | Upto 14.50 | 1.80 |
Explanation: - For height of buildings exceeding 14.50 meters, rule 50 shall be referred to.
Provided that, a building upto 8.00 mt. of height, on a plot measuring not more than 165 sqm, should have a minimum front open space of 01.20 mt.
Provided further that, for mixed use buildings, the minimum front open space shall be the one, applicable for that particular occupancy which gives the highest provision of the minimum front open space in this rule.
Note: mixed use building means and includes the combination of residential, commercial, industrial, office, institutional or other uses."
(ii) Sub-rule (3) of rule 48 of the Principal Rules shall be substituted with the following:
"(3) The minimum rear open space shall be as follows:-"
Every building shall have a minimum rear open space at ground level (open to the sky without any cantilever projection excepting chajja or weather shades of not more than 0.50 metre width) of a width at its narrowest part of not less than that indicated below:-
| Height of building (metres) | Minimum rear open space at its narrowest part (metres) |
|---|---|
| Up to 10.00 | 1.00 |
| Above 10.00 but not more than 14.50 | 1.20 |
Explanation: - For height of buildings exceeding 14.50 meters, rule 50 shall be referred."