- Outhouse.-An outhouse with zero rear and one side set back may be permitted on a plot having an area not less than 400sq.m, provided that:
(1) The coverage of the outhouse shall not exceed 30 sq.m. and the height shall not exceed 3 m.;
(2) The built up area of the outhouse and that of the main building together shall not exceed the permissible FAR for the concerned plot;
(3) The outhouse shall not cover more than one third of the width and more than one fourth of depth of the plot and shall not about any public road;
(4) A minimum 1.5 m. strip of land shall be kept open to the sky between the main building and the outhouse;
(5) No opening either in the form of windows or doors or ventilators shall be provided to the adjoining properties;
(6) Outhouses with sloping roof would only be permitted. In no case permission for outhouses would be granted with reinforced concrete cement flat roof.
- Semi-detached and row housing.(1) Owners of adjacent similar dimension plot abutting a road may be permitted to construct row or semi-detached buildings.
(2) The orientation of the row or semi-detached building shall preferably be such to ensure proper ventilation.
(3) For semi-detached buildings over two adjacent plots, the setbacks, the height and the FAR shall be regulated by treating both the plots as one.
(4) In case of row housing, the length of a row shall not exceed 50 m. along the road on which such houses abut. In case, the dwelling units in a row are scattered the maximum length of the road shall be 100 m.
(5) The minimum size of the plot on which a unit of a row housing may be allowed shall be 50 sq. m.
- Shop cum residence.-Where plots are in a row for shop-cum-residential purpose the Authority may allow construction of shop-cum-residential building without any side set backs up to a depth of 10 meters from the front exterior wall. Provided that no part of the building up to said depth is used for residential purpose on the ground floor. No building exceeding 12 meters in height shall be allowed to be constructed as a shop-cum-residential plot, unless so permitted under the zonal Development Plan, provided that the shop-cum-residence shall have 2/3rd of the total floor area used for shops. The FAR and other parameters shall conform to that specified for commercial buildings.
Bihar Building Bye-Laws
(3)/(4) 1 = ( 2)/(4 + 2 - 7)
- Cinema, Multiplex and Theatre building.-(1) The relevant provisions of the Bihar Cinemas (Regulation) Act, 1954 shall apply for planning, designing and construction of Cinema and Theatre buildings.
(2) No permission for construction of a building to be used as a cinema hall, theatre or auditoria for cultural show shall be granted unless the construction of such buildings conforms to the provisions of the Bihar Cinemas (Regulation) Act, 1954 or any other law in the subject for the time being in force in the State.
(3) All cinema, theatre or auditoria buildings shall conform to IS; 4898-1968 and acoustics design of such buildings shall adhere to the requirements of IS; 2526-1963.
(4) Exits and fire safety requirements shall be in accordance with Part IV (Fire and life safety) of National Building Code of India, 2005.
- Liquefied Petroleum Gas.-(1) Vacant space shall be maintained at all times, with the following distances for storage shed used for the storage of liquefied petroleum gas cylinders between any building, public space, public road or any adjoining property which may be built upon and the said storage shed. The minimum clear distance shall be as per Table 21.
Table - 21: Minimum distances required for storage shed of liquefied petroleum gas cylinders
| Quantity of Compressed Gas in Cylinders (Kg.) | Minimum Clear Distance to be Kept (metres.) |
|---|---|
| 0-100 | 1 |
| 101 -1000 | 3 |
| 1001-4000 | 5 |
| 4001-8000 | 7 |
| 8001-12000 | 9 |
| 12001-30,000 | 12 |
| Over 30,000 | 15 |
(2) Notwithstanding anything contained in the conditions specified above, cylinders containing liquefied petroleum gas exceeding 100 Kilograms but not exceeding 300 Kilograms may be kept in a storage shed forming part of, or attached to building, if it is separated there from by a substantial partition and the only means of access to it is from outside. Such a storage shed shall not be situated under any staircase or near other entrances to or exits from the rest of the building or other buildings. A shed used for storage of liquefied petroleum gas cylinders shall be surrounded by a suitable fence to prevent unauthorized persons from having access to the shed.
- Petrol Pump.-(1) Minimum distance from the road intersections shall be:
A. For minor roads having less than 30 m. width - 50 m.
B. For major roads having width 30 m. or more -100 m.
Bihar Building Bye-Laws (1)/(2) 597-411-2/112-14 400-11

-84
(2) The minimum distance of the property line of petrol pump from the centre line of the road shall not be less than 15 meters on roads having less than 30 m width. In case of roads having 30 m or more width, the width of the road shall be protected.
(3) Plot size:
A. Only for filling stations -30mX20m
B. Filling-cum-service station 40 m X30 m
C. Frontage of the plot shall not be less than 30 m
(4) New petrol pump shall not be located on roads having less than 30 m width
(5) Every petrol pump shall have public toilets with W.C. separately for men and women.
(6) (A) Other controls
i. Ground coverage - 20%
ii. FAR -1.0
iii. Max. Height -7m
iv. Canopy equivalent to permissible ground coverage within setback line,
v. Front set back - minimum 9 m
(B) Other regulations
i. NOC from Explosives/Fire Department ii. License from the District Magistrate iii. Ground coverage will exclude canopy area
(C) Compressed Natural Gas (CNG) mother station
i. Plot size (Max)- 36 m X 30 m
ii. Maximum ground coverage - 20%
iii. Maximum height-7m(single storey)
iv. Building component- control room/office/dispensary, store, pantry and W.C.
- Farm House.-(1) For construction of Farm House Building in Agriculture and Forest use Zone
(2) Minimum size of plot- Minimum size of a plot for farmhouse shall not be less than 1.00 hectare.
(3) Maximum coverage and FAR shall be as given in the table-22.
TABLE - 22 : Maximum coverage and FAR
| A | Maximum permissible ground coverage for all types of activity | 10% |
|---|---|---|
| B | Maximum permissible FAR | 0.20 |
his
Bihar Building Bye-Laws
Symbalan 4ohc b q
-85-
| C | Residential accommodation of watch and ward/maintenance staff | 40 sq m. |
|---|---|---|
| D | Maximum height | 7m. |
| E | Setbacks | Front/side abutting road 15.0m. and all other sides 9.0 |
(4) Other Provisions: Minimum 65% of the total area of the farmhouse shall be under plantation/cultivation. At least 100 trees per hectare shall be planted out of which at least 50 percent shall be evergreen trees.
(5) Water supply, Sewerage and drainage:
A. In case of a plot for a farmhouse having dwelling units, the owner thereof shall be responsible to make lawful arrangements for potable water.
B. The owner shall be responsible to provide drains in the farm house to be used for rain water and in case of dairy farm open or closed sanitary drains to clean sheds, as may be required by the Authority.