For calculating the overall U-factor of a typical wall construction, the U-factors from the typical wall construction type and effective U-factor for insulation shall be combined according to the following equation:
where
U T o t a l W a l l Total U-factor of the wall with insulation
U T y p i c a l W a l l U-factor of the wall
U-factor of the effective insulation
Table 10-2 Typical Thermal Properties of Common Building and Insulating Materials2,a
APPENDIX
2 ASHRAE- Handbook of Fundamentals
APPENDIX
APPENDIX
APPENDIX
APPENDIX
APPENDIX
APPENDIX
APPENDIX
APPENDIX
APPENDIX
aValues are for mean temperature of 2 4 ° C . Representative values for dry materials are intended as design (not specification) values for materials in normal use. Thermal values of insulating materials may differ from design values depending on in-situ properties (e.g., density and moisture content, orientation, etc.) and manufacturing variability. For properties of specific product, use values supplied by manufacturer or unbiased tests.
bSymbol λ also used to represent thermal conductivity.
cDoes not include paper backing and facing, if any. Where insulation forms boundary (reflective or otherwise) of airspace
dConductivity varies with fiber diameter. Batt, blanket, and loose-fill mineral fiber insulations are manufactured to achieve specified R-values, the most common of which are listed in the table. Because of differences in manufacturing processes and materials, the product thicknesses, densities, and thermal conductivities vary over considerable ranges for a specified R-value.
eValues are for aged products with gas-impermeable facers on the two major surfaces. An aluminum foil facer of 25 µm thickness or greater is generally considered impermeable to gases. For change in conductivity with age of expanded polyisocyanurate.
fCellular phenolic insulation may no longer be manufactured. Thermal conductivity and resistance values do not represent aged insulation, which may have higher thermal conductivity and lower thermal resistance.
gInsulating values of acoustical tile vary, depending on density of board and on type, size, and depth of perforations.
hValues for fully grouted block may be approximated using values for concrete with similar unit density. iValues for concrete block and concrete are at moisture contents representative of normal use.
jValues for metal or vinyl siding applied over flat surfaces vary widely, depending on ventilation of the airspace beneath the siding; whether airspace is reflective or nonreflective; and on thickness, type, and application of insulating backing-board used. Values are averages for use as design guides, and were obtained from several guarded hot box tests (ASTM Standard C236) or calibrated hot box (ASTM Standard C976) onhollow-backed types and types made using backing of wood fiber, foamed plastic, and glass fiber. Departures of ±50% or more from these values may occur.
kVinyl specific heat = 1.0 kJ/(kg·K)
lSee Adams (1971), MacLean (1941), and Wilkes (1979). Conductivity values listed are for heat transfer across the grain. Thermal conductivity of wood varies linearly with density, and density ranges listed are those normally found for wood species given. If densityof wood species is not known, use mean conductivity value. For extrapolation to other moisture contents, the following empirical equation developed by Wilkes (1979) may be used:
where ρis density of moist wood in kg/m3, and M is moisture content in percent. mFrom Wilkes (1979), an empirical equation for specific heat of moist wood at 24°C is
where Δcp accounts for heat of sorptio
Δ C p = M (1. 9 2 1 × 1 0 - 3 - 3. 1 6 8 × 1 0 - 5 M)
where M is moisture content in percent by mass.
nBlank space in reference column indicates historical values from previous volumes ofASHRAE Handbook. Source of information could not be determined.