8.1 The means of exclusive access other than thorough public roads and streets, shall not be of more than 30 meters in length from a public road or street. The minimum width of such access shall be 3.5 meters. F.A.R. and height of buildings coming up on such plots connected by means of exclusive access shall be regulated according to the width of public street or road. If the means of access exceeds 30.00 mtrs in length, FAR shall be regulated with reference to the width of such access road. Construction of buildings on plots with common access / lanes from the public road / street shall be regulated according to the width of such common access roads / lanes.
8.2 Existing conservancy lanes are not allowed to be used as means of access to the properties.
8.3 No building shall be erected so as to obstruct the means of access of any other building.
8.4 No person shall erect a building so as to encroach upon the means of access.
8.5 The means of access shall be clearly shown in the plans submitted indicating the width, length from the public road, width of the public road from which the access is taken etc.
8.6 Every such means of access shall be drained and lighted to the satisfaction of the Authority and manhole covers or other drainage, water or any other fittings, laid in such means of access shall flush with the finished surface level so as not to obstruct the safe movement.
8.7 The existing width of the means of access shall not be reduced in any case.
9.0Open Spaces, Coverage and Floor Area Ratio.
9.1 Open spaces – Every room intended for human habitation shall abut on an interior or exterior open space or open verandah open to such interior or exterior open space.
9.2 Exterior open spaces/ set backs, coverage, floor area ratio, numbers of floors and heights - The set backs required on all the sides of building/s, maximum plot coverage, maximum FAR, maximum number of floors, maximum height of buildings that are permissible for different dimensioned sites and widths of roads are set out in Tables 4, 5 and 6 given below.
TABLE 4
(Bye-law 9.2)
EXTERIOR OPEN SPACES/SETBACKS IN METRES FOR RESIDENTIAL, COMMERCIAL, PUBLIC & SEMI-PUBLIC, TRAFFIC & TRANSPORTATION AND PUBLIC UTILITY BUILDINGS
UPTO 9.5 MTRS. IN HEIGHT
Depth of site in mtrs.
Residential - Front
Residential - Rear
Commercial - Front
Commercial - Rear
T & T. P.U.& Public and Semi-Public - Front
T & T. P.U.& Public and Semi-Public - Rear
Width of site in mtrs.
Residential - Left
Residential - Right
Comercial - Left
Comercial - Right
T & T. P.U. & Public and Semi Public - Left
T & T. P.U. & Public and Semi Public - Right
Upto 6
1.00
-
1.00
-
1.50
-
Upto 6
-
1.00
-
-
-
1.50
Over 6 upto 9
1.00
1.00
1.50
-
1.50
1.50
Over 6 upto 9
1.00
1.00
-
1.50
1.50
1.50
Over 9 upto 12
1.50
1.50
1.50
1.50
3.00
1.50
Over 9 upto 12
1.50
1.50
1.50
1.50
1.75
1.50
Over 12 upto 18
3.00
1.50
3.00
1.50
3.00
1.50
Over 12 upto 18
1.50
3.00
1.50
3.00
2.00
3.00
Over 18 upto 24
4.00
3.00
3.50
3.00
4.50
2.00
Over 18 upto 24
2.50
3.50
2.50
4.00
3.00
3.00
Over 24
5.00
3.50
4.50
3.00
6.00
3.00
Over 24
3.00
4.00
3.00
4.50
3.50
4.50
Abbreviations T & T = Traffic & Transportation, P.U. = Public utility.
TABLE 5 (Bye-law 9.2)
EXTERIOR OPEN SPACES/SET-BACKS FOR RESIDENTIAL, COMMERCIAL, PUBLIC AND SEMI-PUBLIC, TRAFFIC & TRANSPORTATION , PUBLIC UTILITY BUILDINGS – ABOVE 9.5 MTS. IN HEIGHT
Sl. No.
Height of Building in mtrs.
Exterior open spaces / set-backs to be left on all sides (Front, Rear and Sides) in mtrs.
1
Above 9.5 upto 12
4.5
2
Above 12 upto 15
5.0
3
Above 15 upto 18
6.0
4
Above 18 upto 21
7.0
5
Above 21 upto 24
8.0
6
Above 24 upto 27
9.0
7
Above 27 upto 30
10.0
8
Above 30 upto 35
11.0
9
Above 35 upto 40
12.0
10
Above 40 upto 45
13.0
11
Above 45 upto 50
14.0
12
Above 50
16.0
TABLE 6
(Bye-law 9.2 and 9.10) COVERAGE AND FAR FOR RESIDENTIAL, COMMERCIAL, PUBLIC AND SEMI-PUBLIC, TRAFFIC & TRANSPORTATION, AND PUBLIC UTILITY BUILDING
Plot Area in Sq. mtr.
Residential
Commercial
Public & Semi Public T&T & Public Utilities
Road width (Mtrs)
Plot Cove-rage Max.
F.A.R. Max.
Plot Cove-Rage Max.
F.A.R. Max.
Plot Cove-rage Max.
F.A.R Max.
A - INTENSELY DEVELOPED AREA
Upto 240
65%
0.75
65%
1.00
60%
1.00
Upto 6
Over 240 Upto 500
60%
0.75
60%
1.00
55%
1.00
Over 6 upto 9
Over 500 Upto 750
60%
1.00
60%
1.25
50%
1.00
Over 9 upto 12
Over 750 Upto 1000
60%
1.00
60%
1.25
50%
1.25
Over 12 upto 15
Over 1000
60%
1.25
55%
1.50
45%
1.25
Over 15
B - MODERATELY DEVELOPED AREA
Upto 240
65%
1.00
65%
1.25
60%
1.00
Upto 9
Over 240 Upto 500
60%
1.25
60%
1.50
55%
1.25
Over 9 upto 12
Over 500 Upto 750
60%
1.25
60%
1.50
50%
1.25
Over 12 upto 15
Over 750 Upto 1000
60%
1.50
60%
1.75
50%
1.50
Over 15 upto 18
Over 1000
60%
1.75
55%
1.75
45%
1.50
Over 18
C - SPARSELY DEVELOPED AREA
Upto 240
65%
1.00
65%
1.25
60%
1.25
Upto 9
Over 240 Upto 500
60%
1.25
60%
1.50
55%
1.50
Over 9 upto 12
Note 1: The dimensions in British system if any, adopted for the dimensions of plots may be interpreted as follows in Metric system and set backs may be applied accordingly.
Note 2 : The open spaces to be provided shall conform to the height necessary to consume the permissible FAR.
Note 3: (a) The front and rear set backs shall be with reference to the depth of the site.
(b) The left and right set backs shall be with reference to the width of the site.
(c) If the height of a building exceeds 9.5 metres, the set backs to be provided shall be higher of the set backs specified in tables 4 and 5.
Note 4 : Building lines have been prescribed to certain roads by the Bangalore Development Authority in Table 33 of the Zoning Regulations. This table is appended as Schedule X to these bye-laws. In such cases, the front set back or the building line which is higher of the two shall be provided.
Note 5 : In the case of corner sites both the sides facing the road shall be treated as front side and regulations applied accordingly to maintain the building line on these roads and to provide better visibility.
Note 6 : In the case of a building facing more than two roads, the plot should be considered as corner plot taking two wider roads into consideration.
Note 7 : In the case of sites facing roads both in front and rear, both the sides facing roads should be treated as front and other two sides not facing roads should be treated as right and the setbacks be applied accordingly.
Note 8 : In case where the plinth of the building is not parallel to the property line, the setbacks shall not be less than the specified setbacks at any given point on any side.
Note 9 : In case of irregular plots the set-backs are to be calculated according to the depth or width at the points where the depths or widths are varying. Average set-backs shall not be considered in such cases.
Note 10 : The left and right set-backs may be interchanged by the Authority in exceptional cases due to existing structures like; open well and also considering the topography of the land. However, this shall be resorted to by the Authority only as an exception.
Note 11: Set-backs should be provided in the owner’s plot. Public open space or conservancy should not be considered as set-backs.
Note 12: In case of two or more buildings proposed on a single site, the set-backs shall be applied by considering them as a common building. In such cases, the distance between the two buildings shall be minimum of half the height of the taller building.
Note 13: For plots with an area of more than 750 sqm. bell mouth entrance shall be provided.
Note 14: The front set back mentioned above are minimum. The building shall be shifted back to the building lines, if any declared by any competent authority.
9.3 High rise buildings.
9.3.1 In the case of ‘high-rise buildings’ the minimum set-back all-round the building shall be as in Table 5.
9.3.2 Minimum depth or width of a site for high rise buildings shall be 21 mtrs.
9.3.3. Minimum road width facing a high rise building shall be 12mts.
Part IIIGeneral Building Requirements
7.0 Requirements of building sites
7.1 No piece of land shall be used as a site for the construction of buildings under the following circumstances:
a) if the site is not drained properly or is incapable of being well drained;
b) if the Authority considers that the site is insanitary or it is dangerous to construct a building on it;
c) if the building is proposed on any area filled up with filthy and offensive matter without a certificate from the Health Officer and Corporation Engineer to the effect that it is fit to be built upon from health and sanitary point of view;
d) if the site is within a distance of nine meters from the water spread area of a tank at full tank level;
e) if the owner of the building has not shown to the satisfaction of the Authority that all the measures required to safeguard the construction from constantly getting damp are being taken.;
f) if the building is for an office or public building including school, theatre or assembly on a site which has not been previously approved by the Authority;
g) if the construction of the building thereon is for public worship which in the opinion of the Authority may offend the religious feelings of any class of persons in the vicinity thereof; or which may cause obstruction to the traffic.
h) if the use of the said site is for the purpose of establishing a factory, warehousing, or work place which in the opinion of the Authority will be a source of annoyance to the health and comfort of the inhabitants of the neighbourhood;
i) if it violates any provisions of development plan and Zoning Regulations and
j) if the plot is a revenue site for which permission under the Karnataka Land Revenue Act, 1964 is not obtained under section 95 thereof.
Note: i) Every application for a factory, workshop or work place if it is proposed to employ and use power shall also satisfy the conditions of section 354 of the Act and specific permission thereunder shall be obtained.
(ii)If the proposed use of the building on the site does not conform to the land use proposals of the development plan or zoning regulations, permission from the Bangalore Development Authority (a) for the change of land use and (b) for the sub-division of plot, have to be furnished.
7.2 No Plan shall be sanctioned for a residential detached building on a plot measuring less than 50 sqm. or having width less than 6 metres. In specific cases of sites for housing schemes for EWS, LIG, Slum Clearance and Improvement Schemes as well as reconstruction in case of densely populated areas, and plot sub-divided due to family partitions, the Authority may relax the above conditions.
7.3 The sites which are not located in the approved layouts of the Bangalore Development Authority, shall have sanction for their sub-divisions under section 17 of the Karnataka Town and Country Planning Act, 1961, from the Bangalore Development Authority.
7.4Distance of building from electrical lines
No building shall be erected below an electrical line, as well as within the horizontal distance from the electrical line indicated in the Table 3. The vertical distance below the level of the electrical line and the topmost surface of the building corresponding to the minimum horizontal distance, shall be as indicated in Table 3. The minimum vertical clearance is not applicable if the horizontal distance exceeds the minimum prescribed.
TABLE 3
(Bye-law 7.4)
Distance of buildings from electrical lines
Electrical Lines
Vertical clearance in Meters
Horizontal clearance in Meters
a) Low and medium voltage lines service lines upto 11 KV
2.5
1.2
b) High voltage lines upto and including 11 KV
3.7
1.2
c) High voltage line above 11 and upto and including 35KV
3.7
2.0
7.4.1 To provide a space for locating the distribution transformers and associated equipment as per KERC (ES & D) code leaving 3.0 mtrs from the building within the premises where the specified load is 25KW or more and also in MS Buildings.
9.4Garages
9.4.1. For the buildings upto a height of 9.50 metres, one garage may be permitted in the rear right hand corner of the plot without right and rear set backs, if the following requirements are fulfilled, namely
a) height of the garage does not exceed 3.00 Metres from the ground level;
b) not more than one upper floor is proposed over such a garage;
c) height of the garage and the upper floor, if any, is limited to 6.50 Metres from the ground level;
d) no other structure is proposed over upper floor of the garage;
e) no openings are provided in the garage and its upper floor towards the neighbouring buildings;
f) the upper floor is accessible only from lower floor;
g) not exceeding one side door is provided to the garage at the ground level towards the rear setback of the building;
h) no other structures except one lumber room and a stair case are provided in the rear side of the garage;
i) depth of the lumber room does not exceed 1.25 Metres;
j) length of the garage including the lumber room and stair case does not exceed one third of the length of the site or 6 Metres, whichever is less;
k) width of the garage does not xceed 4 metres;
l) the distance from the outer surface of the garage to the plot boundary is not less than 4.50 metres;
m) in the case of corner plots, the garage is located at the rear corner diagonally opposite to the road intersection.
9.4.2. A Garage not exceeding 3.00 metres width may be permitted as part of the main building with minimum setbacks applicable to such a building, provided such a garage is not located at the intersection of roads in the case of corner sites. The length of the garage shall not exceed one third of the length of the corresponding side of the site or 6.00 metres, whichever is less.
9.5 Provision of ramp in setback :
A ramp provided from surface level of the site to the basement floor shall have a minimum width of 3.50 meters and slope of not more than 1 in 10. The ramp shall have a margin of two meters kept free from the adjacent properties. The gradient of a ramp shall start after leaving a minimum distance of one metres from the front boundary of the plot.
In the case of high rise buildings, the ramp may be provided in the set back area without affecting the free movement of fire tenders.
9.6Application of land use :
9.6.1. Where the nomenclature of a road differs from the one mentioned in the district maps of the development plan, the location of the site may be considered to determine the land use.
9.6.2. In cases of permitted land use, the Zoning Regulations shall be applied to a building keeping in view the use of the proposed building without reference to the land use of the Zone. However, the front set back shall be the higher of the one prescribed for that particular zone or the one prescribed for the use permitted in the zone.
Example: If residential permission is granted in a commercial zone, the regulations applicable to residential use only be adopted except maintaining the higher of the front set back applicable either to commercial or residential use.
9.6.3. The land use indicated towards the road side of a property shall be the land use for the entire property (one property depth) without identifying it for different uses by measuring as per the scale of the maps.
9.6.4. Different uses permitted in a given zone may be allowed in different floors of the building. In such cases, the regulations applicable to the use of the ground floor of the building shall apply to the entire building. When mixed land uses are permitted in the ground floor, the predominent use among them shall be considered as the use of the ground floor.
9.7 Plots facing the roads proposed for widening :
Where upper floors are permitted over the existing buildings which are sanctioned prior to the coming into force of these bye-law s and which are facing the roads proposed for widening in the development plan, the upper floors shall be limited to the proposed line of road widening or building line, if any prescribed.
9.8Additions, alterations and modifications :
i) Any additions, alterations & modifications to existing buildings shall be permitted in accordance with these bye-laws.
ii) In case of the buildings which are existing prior to coming into force of these regulations, upper floors may be permitted according to the existing set-backs only, but limiting the F.A.R. and the number of floors according to the present bye-laws, subject to production of the foundation certificate as prescribed in the bye-law no. 3.2 (9).
9.9 Interior open spaces – The whole of one side of one or more rooms intended for human habitation and not abutting on any of the front, rear or side open spaces shall abut on an interior open space of minimum width of 3 m.
9.10Limitations of floor area and covered area
9.10.1 The coverage, and FAR, for different sizes of plots with reference to existing road width as limiting factor are given in the table No.6 for various types of buildings like residential, commercial, public and semi-public, etc. The local planning area of Bangalore City is divided into A, B & C areas by the Bangalore Development Authority for the purpose of regulating building constructions as under:-
A: Intensely developed area.
B: Moderately developed area.
C: – Sparsely developed area .
Note: (1) A map showing the details of A, B and C areas is available in the office of the Bangalore Development Authority, Bangalore.A copy of this map is appended to these bye-law s.
Note: (2) When two sides of the same road are included in two different areas like: A and B or A and C, then both the sides shall be treated as intensively developed area (‘A’ area) up to one property depth.
Note: (3) When two sides of the same road are included in two different areas like: B and C, then both the sides shall be treated as moderately developed area (‘B’ area) up to one property depth.
9.10.2 In respect of the following buildings, the maximum coverage shall be as prescribed below.
Building
Permissible maximum coverage
a. Hospital
25%
b. Health centre/nursing home
33.33%
c. Nursery school/primary school
33.33%
d. Secondary school
30%
e. College
25%
9.10.3 (a) The floor area of a building shall be the aggregate area of the floors of all parts of the building including thickness of walls, parking area, staircase rooms, lift rooms, ramps, escalators, machine rooms, balconies, ducts including sanitary ducts, water tanks, lobbies, corridors, foyers and such other parts provided for common service.
(b) The floor area ratio shall exempt the floor area used for the following purposes, namely:-
(i) parking space (ii) staircase rooms (iii) lift rooms (iv) ramps (v) escalators (vi) machine rooms (vii) open balconies (viii) ducts including sanitary ducts and (ix) water tanks.
19.0Plinth.
19.1 The height of the plinth at the ground floor level shall not be less than 0.45 m. The basement height should not project more than one metre above the average Ground Level. In case of sloping street reference shall be made with respect to the street level at the centre of the frontage of the plot. Where the level of the plot is different from the street level, the plinth height shall be determined by the Authority with respect to the surrounding average ground level so that adequate drainage from the site is assured.
19.2 In case of plots situated in low lying areas, the plinth level shall be such that sufficient gradient is created for sewerage, and to avoid any risk of surface drains flooding the building.
19.3 In case of access steps to the plinth, the construction shall be within the plot boundaries. In special cases, where the general level of the site is higher than the street level, the Authority shall have the power to impose conditions on the building schemes prescribing the location of the building and of any steps or ramps leading from the streets to the proposed building within the plot only. Such access ways shall be kept completely free of obstructions and open to the sky.
18.0Basement floor
a) Basement floors shall not be used for purposes other than parking and for locating machines used for service and utilities of buildings.
b) Strong rooms only in case of bank buildings. The area to be used for this purpose shall be reckoned for FAR purposes.
c) Installation of Radiology and X ray equipment only in case of Hospital buildings having a capacity of more than 50 beds without office. The area to be used for this purpose shall be reckoned for FAR purposes.
18.2 One basement in the intensely populated are (A Zone) be permitted only for parking purpose, if the area of the premises is 500 sq. mtrs and above with a minimum road width of 12m.
18.3 When a basement floor is proposed for car parking. Convenient entry and exit shall be provided to the basement. Adequate drainage, ventilation and lighting arrangements shall be made to the satisfaction of the Authority.
18.4 If the plinth of the ground floor of the building is constructed leaving more set back than the minimum prescribed, the basement floor may extend beyond this plinth; but no part of the basement shall extend beyond the minimum set backs prescribed to the building within the plot.
18.5 Basement floor is not permissible on sites where the setbacks prescribed in Table 4 are less than 2 metres. In such cases, basement floor may be permitted if setbacks are increased to at least 2 metres.
18.6 Access to the basement shall floor used other than for parking purposes be from inside the building.
18.7 i) Every basement storey shall be atleast 2.4 mtr. in height from the floor to the bottom of the roof slab/ beam / ceiling (whichever is less) and this height of B.F shall not exceed 2.75 metres. In case of high rise buildings/Three Star/ Five Star Hotel Complexes, where extra height is necessary for the installation and running of machinery, or for the purpose of double storeyed car parking where mechanical lifts are used for parking at least for one level, the basement floor may be lowered so as to increase the height upto 3.6 mtrs. This increase in height shall be limited to the area actually required for the machinery or for car parking. Clearance from the Fire Force Department shall be furnished by the applicant for permitting such increase in height.
ii) Adequate ventilation shall be provided for the basement storey. The standard of ventilation shall be the same as required by the particular occupancy according to these bye-laws. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air-conditioning plants, etc.,
10.0Semi-detached houses (back to back or side to side) - Setbacks, coverage, floor area ratio and road width in respect of semi-detached houses shall be as indicated in Table 7.
TABLE 7
(Bye-law 10.0) SEMI-DETACHED HOUSES (back to back or side to side)
Min. combined area of the neighbouring plots
140 sq. mtr.
Coverage
Floor area ratio
Maximum number of floors
Minimum road width
As applicable to Individual plots
Front setbacks for back to back plots:
Shall be equal to the sum of the front and the rear set backs of individual plots
Side set back for plots joined at the side
On a plot on which a semi detached building is proposed the left and the right side setbacks shall be the same as required for the total width of the combined plot treating it is an individual site
11.0 Row housing: Row housing shall have a minimum of three dwelling units and a maximum of 12 dwelling units on one site. Other stipulations are prescribed in Table 8
TABLE 8(Bye-law 11.0)Row housing
1. Min. combined area of plot
:
210 sq. mtr.
2. Max. area of each plot
:
108 sq. mtr
3. Coverage
:
4. Floor area ratio
:
As applicable to
5. Number of floors
:
Individual plots
6. Minimum road width
:
7. Setbacks min.
Front
2.00 m
Rear
1.50 m
Side
2.00 only for end units
20.11Lighting and ventilation requirements.
20.11(1) Natural ventilation: Rooms shall have, for admission of light and air, one or more openings, such as windows and ventilators, opening directly to the external air or into an open verandah. Doors are not counted towards the area of openings in walls for lighting and ventilation purposes.
20.11(2) Artificial ventilation: Where the light and ventilation requirements are not met through daylight and natural ventilation, the same shall be ensured through artificial lighting and mechanical ventilation, as per Part VIII Building Service section I, Lighting and ventilation of National Building Code of India brought out by the Indian Standards Institution. The provisions contained in the latest version of the Code shall be made use of at the time of enforcement of the bye-laws.
20.11(3) Area of openings: a) Minimum aggregate area of openings excluding doors, shall not be less than 1/6th of the floor area in the case of residential buildings. In the case of other public buildings like business houses, educational buildings, offices, institutional and hospital buildings, the minimum aggregate area of openings shall be not less than 1/5th of the floor area. The area of openings shall be increased by 25% in the case of kitchen. No portion of a room shall be assumed to be lighted if it is more than 7.5 m from the opening.
b) In case of bath rooms and water closets, minimum area of window or ventilator shall be 0.9 sq. mtrs. with one side being not less than 0.3 mtrs.
20.11(4) Ventilation shaft - For lighting and ventilating the space in water closets and bath rooms, when no opening is provided towards any open spaces, they shall open on to the ventilating shaft, the size of which shall not be less than as indicated below:
No. of storeys
Size of ventilation shaft in sqm.
Minimum width in mts.
Upto 2
1.2
0.9
Upto 4
1.8
1.2
Upto 6
4.0
1.5
Upto 8
5.4
1.8
Upto 10
8.0
2.4
11 and above
9.0
3.0
20.0Requirement of parts of building.
20.1 Habitable rooms – (1) No habitable room shall have a floor area of less than 8.0 sqm. for plot sizes upto 120 sqm with a minimum width of 2.4 m.
(2) The minimum height of all rooms used for human habitation shall be 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom slab). In case of air conditioned rooms, the height of not less than 2.4 m. measured from the surface of the floor to the lowest point of the air conditioning duct or false ceiling
shall be provided. Where beams are provided the minimum head room shall be 2.4 m.
20.2 Kitchen – (1) The area of the kitchen where a separate dining area is provided shall not be less than 5 sqm. with a minimum width of 1.8 m. Where there is a separate stores, the size of the kitchen may be reduced to 4.5 sqm. A kitchen which is also intended for dining shall have a floor area of not less than 7.5 sqm. with a minimum width of 2.1 m.
(2) The height of the kitchen shall not be less than 2.75 m. Where beams are provided the minimum head room shall be 2.4 m.
(3) Every room to be used as a kitchen shall have the following conveniences, namely:-
a) unless separately provided with a pantry, provision should be made for washing of kitchen utensils with proper drainage.
b) an impermeable floor.
c) proper chimney and flue to be provided for the escape of gases.
20.3 Bath room and water closets – (1) The size of a bath room shall not be less than 1.8 sqm. with a minimum width of 1.2 m. If it is a combined bath and water closet, its floor area shall not be less than 2.0 sqm, with a minimum width of 1.2 m. The minimum floor area for water closets shall be 1.1 sqm. with a minimum width of 0.9 mtrs.
(2) The height of a bath room or water closet measured from the surface of the floor to the lowest point of ceiling shall not be less than 2.2 m.
Every room used as bath room and water closet,-
a) shall be so situated that atleast one of its walls shall have external wall opening (see byelaw 20.11.3.b).
b) shall have the platform or seat made of water-tight non-absorbent materials.
c) shall be enclosed by walls or partitions and the surface of every such wall or partition shall be furnished with a smooth impervious material to a height of not less than 1 m. above the floor of such a room.
d) i) shall be provided with an impervious floor covering, sloping towards the drain with a suitable grade and not towards verandah or any other room.
21.1General
21.1.1 Every building meant for human occupancy shall be provided with exits sufficient to permit safe escape of occupants, in case of fire or other emergency.
21.1.2 In every building for multi family dwellings and all places of assembly, exits shall comply with the minimum requirements of these bye-laws.
21.1.3 All exits shall be free of obstructions.
21.1.4 No building shall be altered so as to reduce the number, and size of exits to less than that required.
21.1.5 Exits shall be clearly visible Routes to reach the exits shall be clearly marked and signs posted so as to guide the persons using each floor.
21.1.6 Wherever necessary, adequate and continuous illumination shall be provided for exits.
21.1.7 Fire fighting equipment shall be suitably located and clearly marked.
21.1.8 Alarm devices shall be installed to ensure prompt evacuation of the persons concerned.
21.1.9 All exits shall provide continuous means of egress to the exterior of buildings or to the exterior open space leading to a street.
21.1.10 Exits shall be so arranged that they may be reached without passing through another occupied unit.
21.2 Arrangement of exits – Exits shall be so located that the travel distance on the floor shall not exceed the limits given in Table 14.
21.9Fire escapes or external stairs - a) Fire escapes shall not be taken into account in calculating the evacuation time of a building;
b) All fire escapes above ground level shall be directly connected to the ground and shall not lead to the basement floor;
c) All entrances to a fire escape shall be separate and remote from the internal staircase;
d) The route to fire escape shall be free of obstruction at all times except a door way leading to the fire escape which shall have the required fire resistance;
e) Fire escapes shall be constructed of non-combustible materials;
f) Stairs of fire escapes shall have straight flights not less than 75 cm. wide, 20 cm. tread and with risers not more than 19 cm. The number of risers shall be limited to 16 per flight;
g) Handrails shall be of a height of not less than 100 cm.
21.10 Spiral stairs (fire escape) – The use of spiral staircases shall be limited to low occupant loads and to buildings of not more than 9 metres height, unless they are connected to platforms such as balconies and terraces to provide for a pause during escape. A spiral fire escape shall be not less than 150 cm in diameter and shall be designed to give adequate headroom;
(c) Parking area shall be exempted to the extent required for the building.
(d) The area covered by the following structures on the roof are exempted from the floor area upto fifteen percent of the area of the roof over which they are erected, namely:-
(i) staircase rooms (ii) lift machine rooms (iii) pent house (iv) water tanks (v) equipments for ventilation, air conditioning and similar services.
(e) Lobbies, corridors provided in the plan shall be considered for F.A.R.
(f) The nomenclature of certain roads may differ with those mentioned in the District Maps of the Revised C.D.P. In such cases, the location of the site may be considered to determine the land use.
Note : One penthouse only is permissible for a building. The area of the penthouse with staircase room shall be limited to 19 sq.mtrs. If this limit is exceeded, the structures shall be considered for reckoning the FAR.
9.10.4 When sites do not face the roads of required width noted against each, then the FAR applicable to the corresponding width of roads shall apply.
9.10.5 When a site faces wider road than the one prescribed against it, the FAR shall be restricted only to the limit prescribed for the area of that particular site.
9.10.6 When coverage is less than the maximum prescribed in Table 6, floors and height beyond the limits indicated in table 5 may be permitted to utilise the full FAR subject to the provision of minimum set backs prescribed in Tables 4 and 5, whichever is applicable.
9.10.7 The set-backs and coverage shall be determined irrespective of the width of the road.
9.10.8 Buildings for cinemas - Setbacks and other requirements for permanent or other cinema buildings shall be in accordance with the Karnataka Cinemas (Regulation) Act 1964 and the rules made there under. No building other than a cinema theatre shall be permitted on the sites of cinema theatres unless such buildings are permissible under the above said Act.
9 .10.9 Minimum Road Width for Kalyana Mantapas –
TABLE - 6A
Site Area
Minimum Road width
a) Upto 250Sq.Mtrs.
9.00 Mtrs
b) Over 250 Upto 500 Sq.Mtrs
12.00 Mtrs
c) Over 500 Upto 1000 Sq.Mtrs
15.00 Mtrs
d) Over 1000 Sq.Mtrs
18.00 Mtrs
iii) The basement storey should not project more than 1.00 mt. above the average Ground level.
iv) Adequate arrangements shall be made to ensure that surface drainage does not enter into a basement storey
18.8 The basement floor shall not normally be partitioned. If the ventilation standards as laid down in sub-clause (ii) of bye-law 18.7 are met with, the partition of basement may be permitted.
18.9 Adequate protection against fire shall be provided to the basement storey. The roof separating the basement and the floor above shall be constructed of materials like RCC or such other material which can provide resistance against fire for atleast two hours. Where a basement floor is permitted in apartment houses (residential flat) and hotels, the owner shall display the basement plan at the entrance. Thimbles (metal rings to receive wires/ropes) shall be provided in the roof of the basement and their positions clearly indicated on the plan. One fire extinguisher for every 100 sqm. of basement area or part thereof, shall be provided.
18.10 The walls and the floors of the basement shall be watertight and shall be so designed that the hydraulic pressure of the sub-soil water level is fully arrested.
18.11 Necessary arrangements shall be made to prevent moisture on walls.
18.12 No place in a basement floor shall be more than 11.25 Mtrs away from the exit in case of residential / educational / institutional / hazardous buildings, 15 mtrs for commercial buildings and 22.5 mtrs for industrial buildings.
18.13 One additional basement for all buildings exceeding five floors may be permitted for parking and machines used for services and utilities of the buildings. The maximum number of basements in such buildings shall be two.
18.14 Two additional basements in case of three star and above hotels may be permitted for parking and machines used for service and utilities of buildings. The maximum number of basements in such buildings shall be three.
12.0 Group Housing
21.0 Exit requirements for high rise buildings, public and industrial buildings
ii) shall not be used for any purpose except as a lavatory and no such room shall open directly into a kitchen or cooking space by a door, window or other openings. Every room containing water closets shall have a door completely closing the entrance to it.
e) shall have flush-out facility.
20.4 Mezzanine floor – (1) Not more than one mezzanine floor shall be permissible in a building.
(2) A Mezzanine floor shall be accessible only from its lower floor.
(3) Minimum size of mezzanine floor if it is used as a living room shall be 9.5 sqm. The aggregate area of a mezzanine floor shall not exceed 1/3 (or 33.33%) of covered area of its lower floor.
(4) The minimum height of mezzanine floor shall be 2.2 m.
(5) A Mezzanine floor may be permitted over a room or a compartment
(6) It shall conform to the standards of the habitable room as regards lighting and ventilation:
(7) It shall be constructed without interfering with the ventilation of the space over and under it;
(8) A mezzanine floor shall not be sub-divided into smaller compartments unless adequate ventilation is provided;
(9) A mezzanine floor or any part of it shall not be used as a kitchen;
(10) In no case, a mezzanine floor shall be closed so as to make it liable to be converted into unventilated compartments.
20.5 Loft – (1) A Loft provided in a kitchen shall not exceed 25% of the area of the kitchen and when provided over a bath room, water closet and corridor, the loft can occupy up to 100% of the area.
(2) The head room for the loft shall be not more than 1.5 m.
20.6 Stair-case (1) The Minimum clear width, minimum tread and maximum riser of staircases for buildings shall be as given below:
The Minimum width of stair cases shall be as follows,
a) Residential buildings (dwellings) 1.0 mtr.
Note: For row housing with two storeys, the minimum width shall be 0.75 mtr.
b) Residential hostel buildings 1.5 mtr.
c) Assembly building like auditoria, theatres and cinemas 1.5 mtr.
d) Educational building upto 24 mtrs in height 1.5 mtr.
e) Educational building more than 24 mtr. in height 2.0 mtr.
f) Institutional buildings upto 10 beds 1.5 mtr.
g) Institutional buildings more than 10 beds 2.0 mtr.
h) All other buildings 1.5 mtr.
The minimum width of tread without nosing shall be 25 cm. for residential buildings. The minimum width of tread for other buildings shall be 30 cm.
Maximum riser shall be 19 cm. for residential buildings and 15 cm. for other buildings and they shall be limited to 15 per flight.
(2) The minimum clear head room in a stair case shall be 2.2 mtr.
20.7 Lifts - Provision of lifts shall be made for all buildings with a height of 15 mtrs. and above and or having more than ground plus three floors in accordance with Part VIII, section 5 of the National Building Code with regard to planning and designing of lifts. Lifts shall be terminated at the topmost floor.
20.8 Boundary wall- a) Except with the special permission of the Authority,
(i) the maximum height of the front and side boundary wall shall be 1.5 mts. above the ground level;
(ii) The rear boundary walls shall not have a height of more than 2 mts. above the centre line of the service road or where there is no service road 2 mts. above the ground level;
(iii) In case of corner plots, the height of the boundary wall shall be restricted to 0.75 m. for a length of 5 m from the intersection on either side. The corners of the boundary wall in such cases shall be rounded off or cut off as indicated in the bye-law 17.0;
b) The stipulations of clause (a) of the bye-law of 20.6, are not applicable to the boundary walls of jails, sanatoria and heavy industries and women’s hostels;
c) The boundaries of the building sites shall not be provided with barbed wire fence, prickly hedge or other objectionable plants.
20.9 Industrial buildings - The minimum height of rooms shall be as provided in the Factory Act, 1948 and rules made thereunder.
20.10 Disposal of polluted and unpolluted water - a) Separate drains shall be provided for the disposal of polluted and unpolluted water seperately from the buildings. Polluted water shall be the water coming out from lavatories, bathrooms, water closets, kitchen and from other parts of the building which is already used for domestic or other purposes. Unpolluted water shall include rain water and the unpolluted subsoil water, if any.
b) Roof of every building shall be constructed so as to permit effectual drainage of rain water therefrom by means of sufficient rain water pipes of adequate size wherever required, which shall be so arranged, jointed and fixed as to ensure that the rain water is carried away from the building without causing dampness in any part of the wall or foundation of the building or those of an adjacent building or causing annoyance or inconvenience to the neighbour or passer-by.
c) Subject to bye-law 32.0, rain water pipe shall be connected to the roadside drain or may be carried out in any other approved manner without causing damage to the property of the Corporation.
d) Subject to bye-law 32.0, rain water pipe shall be affixed to the out-side of the external walls of the building or in recesses or chases cut or formed in such external walls or in such other manner as may be approved by the Authority.
12.1Norms for Approval of Group Housing Plan
The following norms shall be adopted while approving the layout plan for group housing:-
i) The boundary roads if any must have a minimum width of 12 mtr.
ii) The FAR should be considered with reference to the width of the public road abutting the property and the FAR should be calculated after deducting the area reserved for parks, open spaces and civic amenities.
iii) The set-backs should be provided with reference to depth and width of total plot area.
iv) The coverage shall be with reference to total area of the layout.
v) The distance between the buildings should be a minimum of half of the hieght of the tallest building.
vi) 25% of the total area be reserved for CA, parks and open spaces, subject to a minimum of 15% for parks and open space.
vii) The means of access to the building blocks in the area of group housing shall be as follows:
Access length in mtrs. Min. width
a) Less than 100 mtrs. 6 mtrs.
b) 100 to 200 mtrs. 9 mtrs.
c) More than 200 mtrs. 12 mtrs.
vii) The area reserved for Parks and Open spaces, CA and roads (other than internal access in each sub-divided plot) shall be handed over free of cost to the B.D.A through registered relinquishment deed before issue of work order.
TABLE 10(Bye-law 13.1) EXTERIOR SET-BACKS, COVERAGE AND F.A.R. FOR INDUSTRIAL BUILDINGS
Plot Area in sq. mtrs
Industry
Maximum plot coverage
Min. set back in Mtrs.
F.A.R.
Road width In mtrs.
Front
Rear & sides
Upto 240
Service
75%
1.00
-
1.00
Over 4.5
Over 240 upto 1000
Service and Light
50%
4.50
4.50
0.75
Over 6.0
Over 1000
Service and Light
upto 2000
50%
6.00
6.00
0.75
Over 9.0
Over 2000
Service, Light and
upto 3000
Medium
40%
10.00
10.00
0.75
Over 12.0
Over 3000
Service, Light and
upto 4000
Medium
40%
12.00
12.00
0.50
Over 12.0
Over 4000
Service, Light, Medium and Heavy
35%
15.00
15.00
0.50
Over 12.0
Note: After leaving minimum set-backs as per the above table, if the remaining portion of the plot cannot be used for erecting the building, the Authority may insist the set backs applicable for residential buildings.
TABLE 11 (Bye-law 13.2) REGULATIONS FOR FLATTED FACTORIES
Minimum plot area
: 1000 sq. mtrs.
Maximum coverage
: 40%
Maximum F.A.R.
1.50 upto 9 mtrs. road width, and
1.75 above 9 mtrs. road width
Minimum setbacks
a. Front 8.0 mtrs.
b. Rear 4.5 mtrs.
c. Sides 4.5 mtrs.
Note: If the height of the building exceeds 9.5 metres, the minimum set back shall be the higher of the two in Tables 5 and 11.
Exemptions in open space - The following exemptions in open space shall be permitted.
14.1 Projections - (1) Every open space provided either interior or exterior shall be kept free from any structure thereon and shall be open to sky and no cornice, roof or weather shade or chajja more than 0.75 metres wide or 1/3 of open space whichever is less shall over-hang or project over the said open space. These projections shall be permitted within one’s own plot boundaries.
(II) No projection shall over hang or project over the minimum setback area either in the cellar floor or at the lower level of the ground floor.
14.2 Cantilever Portico - A cantilever portico of 3 metres width (maximum) and 4.5 metres length (maximum) may be permitted in the ground floor within the side set back. No access is permitted to the top of the portico for using it as a sit out. Height of the portico shall be not less than 2 metres from the plinth level. The terrace of the portico shall be open to sky. The portico when allowed shall have a clear open space of one meter from the boundary of the property.
14.3 Balcony - The projection of the balcony shall be measured perpendicular to the building upto the outermost edge of the balcony. Cantilever projection of the balcony shall be permitted not exceeding 1/3 of the setback subject to a maximum of 1.1 mtrs. in the first floor and 1.75 metres in and above the second floor. No balcony is allowed at the ground floor level. The length of the balcony shall be limited to 1/3 of the length of each side of the building.
14.4 Cross wall - A cross wall connecting the building and the boundary wall may be permitted limiting the height of such wall to 1.5 mtr.
21.3Capacity of exits
i) The unit of exit width used to measure capacity of any exist shall be 50 cm. A clear width of 25 cm. shall be counted as an additional half unit. Clear width less than 25 cm shall not be counted for exit width;
ii) The occupants per unit exit width shall be as given in Table 15.
21.4 Occupant load – The occupant load of buildings shall be worked out as given in Table 16.
21.5 Number of exits - i) The location, width and number of exits shall be in accordance with the travel distance, capacity of exits and the population of building based on occupant load;
ii) There shall not be less than 2 exits serving every floor for buildings of 15 mtrs height and above and at least one of them shall be an internal stairway.
TABLE 14(Bye-law 21.2) TRAVEL DISTANCE FOR OCCUPANTS
Sl. No.
Group of occupancy
Maximum travel distance in mtrs.
1
Residential
22.5
2
Educational
22.5
3
Institutional
22.5
4
Assembly
30.0
5
Business
45.0
6
Commercial
30.0
7
Industrial
30.0
8
Storage
30.0
9
Hazardous
22.5
Note: (1) The travel distance to any exit from the dead end of a corridor shall not exceed half the distance specified above except in educational, assembly and institutional occupancies in which case it shall not exceed 6 m.
(2) Whenever more than one exit is required for any room, space or floor of a building, exits shall be placed as remote from each other as possible and shall be arranged so as to provide direct access to the exits from different directions.
TABLE 15
(Bye-law 21.3)
OCCUPANTS PER UNIT EXIT WIDTH – MAXIMUM NUMBER OF OCCUPANTS
Sl.No.
Group of occupancy
Stairways
Ramps
Doors
1
Residential
25
50
75
2
Educational
25
50
75
3
Institutional
25
50
75
4
Assembly
40
50
60
5
Business
50
60
75
6
Commercial
50
60
75
7
Industrial
50
60
75
8
Storage
50
-
75
9
Hazardous
25
30
40
Note: Horizontal allowance: When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit stairways in the table above, may be increased by 50 % and in the buildings of industrial occupancy, it may be increased by 100%.
TABLE 16(Bye-law 21.4) OCCUPANT LOAD
Sl. No.
Group of Occupancy
Occupant load-gross floor area in sq. mtrs per person
1
Residential
12.5
2
Educational
4.0
3
Institutional
15.0*
4
Assembly
a) With fixed or loose seats and dance floors
0.6**
b) Without seating facilities including dining rooms
1.5**
5
Business and industrial
10.0
6
Storage
30.0
7
Hazardous
10.0
* The gross area shall mean plinth area or covered area. Occupant load in dormitory portions or homes for the aged, orphanages, asylums, etc., where sleeping accommodation is provided, shall be calculated at not less than 7.5 sqm. gross floor area per person.
** The gross floor area shall include, in addition, the main assembly room or space, any occupied connecting room or space in the same storey or in the storeys above or below where entrance is common to such rooms and spaces and they are available for use by the occupants or the assembly place. No deduction shall be made in the gross floor area for corridors, closets or other sub-divisions. The areas shall include all space serving the particular assembly occupancy.
Note: The occupant load of a mezzanine floor discharging to a floor below shall be added to that floor occupancy and the capacity of the exits shall be designed for the total occupancy load thus established.
21.6 Doorways - a) Every exit doorway shall open into an enclosed stairway, a horizontal exit, or a corridor or passageway providing continuous and protected means of egress;
b) No exit doorway shall be less than 75 cm in width in the case of residential buildings and 100 cm in the case of other buildings. Doorways shall be not less than 200 cm. in height.
c) Exit doorways shall open outwards i.e., away from the room. But shall not obstruct the travel along any exit. No door, when open, shall reduce the required width of stairway or landing to less than 90 cm. Overhead or sliding doors shall not be installed;
d) Exit doors shall not open immediately upon a flight of stairs; a landing equal to atleast the width of the door shall be provided in the stairway at each doorway; level of landing shall be same as that of the floor which it serves.
21.7 Revolving doors - a) Revolving doors shall not be used as required exits except in residential, business and commercial occupancies, but shall not constitute more than 1/2 the total required door width;
b) When revolving doors are considered as required exitway, the following assumptions shall be made.
(1) Each revolving door shall be counted as one half of the exit unit width.
(2) Revolving doors shall not be located at the foot of a stairway. Any stairway served by a revolving door shall discharge through a lobby or foyer.
21.8) Staircase - a) Interior stairs shall be constructed of non-combustive materials;
b) Interior staircases of all buildings with the exception of residential buildings upto GF+3 floors shall be constructed as self contained units with atleast one side adjacent to an external wall. The staircase shall be completely enclosed in the case of buildings of 15 meters height and above;
c) A staircase shall not be arranged around a lift shaft unless the latter is entirely enclosed by a material of fire resistance rating;
d) Hollow combustible construction shall not be permitted;
e) The minimum width of an internal staircase shall be as per bye-law 20.6;
The minimum width of treads without nosing shall be as per bye-law 20.6;
The maximum riser shall be as per bye-law 20.6;
h) Handrails shall be provided with a minimum height pf 100 cm. for all buildings and shall be firmly supported;
i) No windings should be provided in a public building except in the case of emergency exits.
15.0Height limitation
15.1 The height of the building shall be governed by the limitation of the FAR, coverage, setbacks and the width of the street facing the plot as stipulated in the respective tables.
15.2 If a building abuts two or more streets of different widths, then the height of the building shall be regulated according to the width of the wider road.
15.3 For buildings within the landing and take off zones of air craft in the vicinity of aerodromes, the maximum height of the building shall be as permissible in 15.1 above, or as shown in Table 12 whichever is lower. These shall be regulated by the rules for the construction of buildings in the vicinity of aerodromes by the competent Aerodrome Authority.
15.4 Height exception for the structures on roof: The following appurtenant structures shall not be included in the height of the building.
i) Water tanks and their supports, equipments for ventilation, air-conditioning and similar services, lift rooms, roof structures like; stair-case room, pent house, chimneys, parapet walls and other architectural features.
ii) The height of parapet wall and architectural features shall not exceed 1.0 metre and the height of other structures shall not exceed 4.50 meters for claiming the height exemption.
iii) The aggregate area of such structures shall be limited to the extent prescribed in the byelaw 9.10.3 (d). If this limit is exceeded, the structures shall be considered for reckoning the height of the building.
TABLE 12 (Bye-law 15.3)
HEIGHT LIMITATIONS IN THE VICINITY OF AERODROMES (a) International civil air-ports and their alternates:
Limits of distance from the aerodromes point measured horizontally to buildings/structures or installations
Difference between the elevation of the top of the buildings/structures of installations and the elevation of the aerodromes (aerodromes reference point)
1 Between 8534 M and 22224 M
Less than 152 M
2 Between 7315 M and 8534 M
Less than 122 M
3 Between 6096 M and 7315 M
Less than 91 M
4 Between 4877 M and 6096 M
Less than 61 M
5 Between 4267 M and 4877 M
Less than 49 M
6 Between 3658 M and 4267 M
Less than 37 M
7 Between 3048 M and 3658 M
Less than 24 M
8 Between 2438 M and 3048 M
Less than 12 M
9 Below 2438 mtrs.
Nil except with the prior concurrence of the local Aerodrome Authority
(b) other civil airports and civil aerodromes:
1 Between 7925 M and 22324 M
Less than 152 M
2 Between 6706 M and 7925 M
Less than 122 M
3 Between 5486 M and 6706 M
Less than 91 M
4 Between 4267 M and 5486 M
Less than 61 M
5 Between 3658 M and 4267 M
Less than 49 M
6 Between 3048 M and 3658 M
Less than 37 M
7 Between 2438 M and 3048 M
Less than 24 M
8 Between 1829 M and 2438 M
Less than 12 M
9 Below 1829 M
Nil except with the prior concurre Aerodrome Authority.
Note: 1) For sl. Nos. (7), (8) and (9), no trees shall be planted within the limits of the distance indicated thereto.
Irrespective of the distance from the aerodrome beyond 22,224 mtrs. of the aerodrome/aerodrome reference point, no radio masts or such similar type of installations exceeding 152 mtrs. in height should be erected with out prior permission of the concerned civil aviation authority.
No buildings structures or installations exceeding the height indicated in (a) and (b) of Table 12 should be permitted without prior consultation with the local authority.
Location of slaughter houses, butcheries and other areas of activities like garbage dumps which would attract high flying birds like eagles, hawks etc., shall not be permitted within a radius of 10 kilometres. from the aerodrome reference point.
16.0 Parking space - Adequate space for the parking of vehicles shall be provided in the sites as per standards given in Table 13 subject to the following stipulations.
a) Each off street car parking space provided for motor vehicles shall not be less than 18 sq.mtrs (3 meters x 6 meters). For motor cycles and scooters, each parking space shall not be less than 2.5 sq.mtrs. (1.25 meters x 2 meters) and for cycles it shall not be less than 1.5 sq.metres. (0.75 meters x 2 meters).
b) Off street car parking space shall be provided with adequate vehicular access to a street and areas of drives of not less than 2.5 mtr. wide, aisles and such other provisions required for adequate monitoring of vehicles shall be exclusive of the parking space stipulated in these bye-laws.
c) No parking space shall be insisted upon in the intensely developed area of the floor space upto 100 sq.meters.
d) In case of non-high rise buildings parking space may be provided in the set back, where the set- back is 6 meters. In such cases, the minimum margin of 3 meters shall be kept free from the building.
e) In case of high rise buildings parking space may be provided in the set back after leaving a minimum setback of 6 Mtrs alround the building to enable movement of Fire Tender.
f) Alternate means of parking such as terrace parking, multi stage parking, parking silos may be permitted, subject to production of NOC’s from the Authorities (in case of high rise buildings). In such cases, a clear height of 3.6 Meters in the basement floor has to be provided, and the space to be earmarked per unit of Car parking may be determined by the authority.
g) Parking in the upper floors can be allowed only if ramps are provided after leaving the minimum setback line to reach such floors.
h) Parking to be allowed on stilts should not be considered as a separate floor and the same shall be exempted from computing the height of the building provided the total height of the building does not exceed 15.00 Mtrs.
TABLE 13(Bye-law 16.0) PARKING REQUIREMENTS
Sl.No.
Type of use
One car parking space shall be provided for every
1
a) Theatres and auditoriums including cinema theatres (except educational institutions);b) Multiplex Theaters
25 seats of accommodation subject to a minimum of 2015 seats of accommodation subject to a minimum of 10
2
Retail business
50 sq. mtr. of floor area
3
Wholesale and warehouse buildings
150 sq. mtr of floor area plus 1 lorry parking space measuring 4 x 8 mtrs. for every 500 sq.mtr. or part thereof.
4
Restaurants, Establishments serving food and drinks and such other establishments
25 sq.mtr. of floor area including hall, dining room, pantry & bar.
5
Lodging establishments and tourist homes
4 rooms
6
Office-buildings (Govt./Semi-Govt. & Pvt.)
50 sq.mtrs. of office floor space.
7
Hostels
10 rooms
8
Industrial buildings
100 sq.mtr. of floor area plus 1 lorry space measuring 4 x 8 mtr. For every 1000 sq.mtr. or part thereof.
9
Nursing homes & Hospitals
4 beds
10
(i) Single Family Dwellings
a) Dwelling Unit measuring 100 to 150 Sq.Mtrsb) 100 Sq.Mtrs and Part thereof beyond 150 Sq.Mtrs.
(ii) Multi Family Dwellings
a) 2 Dwelling units measuring 50 Sq.Mtrs or less.b) Dwelling unit measuring over 50 Sq.Mtrs upto 150 Sq.Mtrs.c) 100 Sq.Mtrs and part thereof beyond 150 Sq.Mtrs
11
Kalyana mandiras
10 sq.mtr. of auditorium floor area
12
Recreation clubs
50 sq.mtr. of floor area
13
Educational buildings
200 sq.mtr. of floor area
14
Other public and semi-public buildings
100 sq. mtr. Of floor area
NOTE: In addition to the above 10% additional parking space shall be provided for parking of visitor’s vehicle’s in case of residential and commercial buildings at serial numbers 5, 6, 7, 9, 10(ii), 12, 13 and 14.
17.0 Buildings at intersection of streets - At the intersection of streets, the corners of the boundary of the plot shall be rounded off or cut-off after leaving a minimum distance of 10% of the frontage of the plot or 3 mts whichever is less from the point of intersection. The Authority may further require the corner of the building to be rounded off or cut-off
parallel to the rounded off or cut-off boundary upto the height of the ground floor. In such cases the FAR is to be allowed for the total area of the plot. Entry or exit for the buildings shall be provided away from the point of intersection.