7.1 No piece of land shall be used as a site for the construction of buildings under the following circumstances:
a) if the site is not drained properly or is incapable of being well drained;
b) if the Authority considers that the site is insanitary or it is dangerous to construct a building on it;
c) if the building is proposed on any area filled up with filthy and offensive matter without a certificate from the Health Officer and Corporation Engineer to the effect that it is fit to be built upon from health and sanitary point of view;
d) if the site is within a distance of nine meters from the water spread area of a tank at full tank level;
e) if the owner of the building has not shown to the satisfaction of the Authority that all the measures required to safeguard the construction from constantly getting damp are being taken.;
f) if the building is for an office or public building including school, theatre or assembly on a site which has not been previously approved by the Authority;
g) if the construction of the building thereon is for public worship which in the opinion of the Authority may offend the religious feelings of any class of persons in the vicinity thereof; or which may cause obstruction to the traffic.
h) if the use of the said site is for the purpose of establishing a factory, warehousing, or work place which in the opinion of the Authority will be a source of annoyance to the health and comfort of the inhabitants of the neighbourhood;
i) if it violates any provisions of development plan and Zoning Regulations and
j) if the plot is a revenue site for which permission under the Karnataka Land Revenue Act, 1964 is not obtained under section 95 thereof.
Note: i) Every application for a factory, workshop or work place if it is proposed to employ and use power shall also satisfy the conditions of section 354 of the Act and specific permission thereunder shall be obtained.
(ii)If the proposed use of the building on the site does not conform to the land use proposals of the development plan or zoning regulations, permission from the Bangalore Development Authority (a) for the change of land use and (b) for the sub-division of plot, have to be furnished.
7.2 No Plan shall be sanctioned for a residential detached building on a plot measuring less than 50 sqm. or having width less than 6 metres. In specific cases of sites for housing schemes for EWS, LIG, Slum Clearance and Improvement Schemes as well as reconstruction in case of densely populated areas, and plot sub-divided due to family partitions, the Authority may relax the above conditions.
7.3 The sites which are not located in the approved layouts of the Bangalore Development Authority, shall have sanction for their sub-divisions under section 17 of the Karnataka Town and Country Planning Act, 1961, from the Bangalore Development Authority.
7.4Distance of building from electrical lines
No building shall be erected below an electrical line, as well as within the horizontal distance from the electrical line indicated in the Table 3. The vertical distance below the level of the electrical line and the topmost surface of the building corresponding to the minimum horizontal distance, shall be as indicated in Table 3. The minimum vertical clearance is not applicable if the horizontal distance exceeds the minimum prescribed.
TABLE 3
(Bye-law 7.4)
Distance of buildings from electrical lines
Electrical Lines
Vertical clearance in Meters
Horizontal clearance in Meters
a) Low and medium voltage lines service lines upto 11 KV
2.5
1.2
b) High voltage lines upto and including 11 KV
3.7
1.2
c) High voltage line above 11 and upto and including 35KV
3.7
2.0
7.4.1 To provide a space for locating the distribution transformers and associated equipment as per KERC (ES & D) code leaving 3.0 mtrs from the building within the premises where the specified load is 25KW or more and also in MS Buildings.
8.0Means of access.
8.1 The means of exclusive access other than thorough public roads and streets, shall not be of more than 30 meters in length from a public road or street. The minimum width of such access shall be 3.5 meters. F.A.R. and height of buildings coming up on such plots connected by means of exclusive access shall be regulated according to the width of public street or road. If the means of access exceeds 30.00 mtrs in length, FAR shall be regulated with reference to the width of such access road. Construction of buildings on plots with common access / lanes from the public road / street shall be regulated according to the width of such common access roads / lanes.
8.2 Existing conservancy lanes are not allowed to be used as means of access to the properties.
8.3 No building shall be erected so as to obstruct the means of access of any other building.
8.4 No person shall erect a building so as to encroach upon the means of access.
8.5 The means of access shall be clearly shown in the plans submitted indicating the width, length from the public road, width of the public road from which the access is taken etc.
8.6 Every such means of access shall be drained and lighted to the satisfaction of the Authority and manhole covers or other drainage, water or any other fittings, laid in such means of access shall flush with the finished surface level so as not to obstruct the safe movement.
8.7 The existing width of the means of access shall not be reduced in any case.
9.0Open Spaces, Coverage and Floor Area Ratio.
9.1 Open spaces – Every room intended for human habitation shall abut on an interior or exterior open space or open verandah open to such interior or exterior open space.
9.2 Exterior open spaces/ set backs, coverage, floor area ratio, numbers of floors and heights - The set backs required on all the sides of building/s, maximum plot coverage, maximum FAR, maximum number of floors, maximum height of buildings that are permissible for different dimensioned sites and widths of roads are set out in Tables 4, 5 and 6 given below.
TABLE 4
(Bye-law 9.2)
EXTERIOR OPEN SPACES/SETBACKS IN METRES FOR RESIDENTIAL, COMMERCIAL, PUBLIC & SEMI-PUBLIC, TRAFFIC & TRANSPORTATION AND PUBLIC UTILITY BUILDINGS
UPTO 9.5 MTRS. IN HEIGHT
Depth of site in mtrs.
Residential - Front
Residential - Rear
Commercial - Front
Commercial - Rear
T & T. P.U.& Public and Semi-Public - Front
T & T. P.U.& Public and Semi-Public - Rear
Width of site in mtrs.
Residential - Left
Residential - Right
Comercial - Left
Comercial - Right
T & T. P.U. & Public and Semi Public - Left
T & T. P.U. & Public and Semi Public - Right
Upto 6
1.00
-
1.00
-
1.50
-
Upto 6
-
1.00
-
-
-
1.50
Over 6 upto 9
1.00
1.00
1.50
-
1.50
1.50
Over 6 upto 9
1.00
1.00
-
1.50
1.50
1.50
Over 9 upto 12
1.50
1.50
1.50
1.50
3.00
1.50
Over 9 upto 12
1.50
1.50
1.50
1.50
1.75
1.50
Over 12 upto 18
3.00
1.50
3.00
1.50
3.00
1.50
Over 12 upto 18
1.50
3.00
1.50
3.00
2.00
3.00
Over 18 upto 24
4.00
3.00
3.50
3.00
4.50
2.00
Over 18 upto 24
2.50
3.50
2.50
4.00
3.00
3.00
Over 24
5.00
3.50
4.50
3.00
6.00
3.00
Over 24
3.00
4.00
3.00
4.50
3.50
4.50
Abbreviations T & T = Traffic & Transportation, P.U. = Public utility.
TABLE 5 (Bye-law 9.2)
EXTERIOR OPEN SPACES/SET-BACKS FOR RESIDENTIAL, COMMERCIAL, PUBLIC AND SEMI-PUBLIC, TRAFFIC & TRANSPORTATION , PUBLIC UTILITY BUILDINGS – ABOVE 9.5 MTS. IN HEIGHT
Sl. No.
Height of Building in mtrs.
Exterior open spaces / set-backs to be left on all sides (Front, Rear and Sides) in mtrs.
1
Above 9.5 upto 12
4.5
2
Above 12 upto 15
5.0
3
Above 15 upto 18
6.0
4
Above 18 upto 21
7.0
5
Above 21 upto 24
8.0
6
Above 24 upto 27
9.0
7
Above 27 upto 30
10.0
8
Above 30 upto 35
11.0
9
Above 35 upto 40
12.0
10
Above 40 upto 45
13.0
11
Above 45 upto 50
14.0
12
Above 50
16.0
TABLE 6
(Bye-law 9.2 and 9.10) COVERAGE AND FAR FOR RESIDENTIAL, COMMERCIAL, PUBLIC AND SEMI-PUBLIC, TRAFFIC & TRANSPORTATION, AND PUBLIC UTILITY BUILDING
Plot Area in Sq. mtr.
Residential
Commercial
Public & Semi Public T&T & Public Utilities
Road width (Mtrs)
Plot Cove-rage Max.
F.A.R. Max.
Plot Cove-Rage Max.
F.A.R. Max.
Plot Cove-rage Max.
F.A.R Max.
A - INTENSELY DEVELOPED AREA
Upto 240
65%
0.75
65%
1.00
60%
1.00
Upto 6
Over 240 Upto 500
60%
0.75
60%
1.00
55%
1.00
Over 6 upto 9
Over 500 Upto 750
60%
1.00
60%
1.25
50%
1.00
Over 9 upto 12
Over 750 Upto 1000
60%
1.00
60%
1.25
50%
1.25
Over 12 upto 15
Over 1000
60%
1.25
55%
1.50
45%
1.25
Over 15
B - MODERATELY DEVELOPED AREA
Upto 240
65%
1.00
65%
1.25
60%
1.00
Upto 9
Over 240 Upto 500
60%
1.25
60%
1.50
55%
1.25
Over 9 upto 12
Over 500 Upto 750
60%
1.25
60%
1.50
50%
1.25
Over 12 upto 15
Over 750 Upto 1000
60%
1.50
60%
1.75
50%
1.50
Over 15 upto 18
Over 1000
60%
1.75
55%
1.75
45%
1.50
Over 18
C - SPARSELY DEVELOPED AREA
Upto 240
65%
1.00
65%
1.25
60%
1.25
Upto 9
Over 240 Upto 500
60%
1.25
60%
1.50
55%
1.50
Over 9 upto 12
Note 1: The dimensions in British system if any, adopted for the dimensions of plots may be interpreted as follows in Metric system and set backs may be applied accordingly.
Note 2 : The open spaces to be provided shall conform to the height necessary to consume the permissible FAR.
Note 3: (a) The front and rear set backs shall be with reference to the depth of the site.
(b) The left and right set backs shall be with reference to the width of the site.
(c) If the height of a building exceeds 9.5 metres, the set backs to be provided shall be higher of the set backs specified in tables 4 and 5.
Note 4 : Building lines have been prescribed to certain roads by the Bangalore Development Authority in Table 33 of the Zoning Regulations. This table is appended as Schedule X to these bye-laws. In such cases, the front set back or the building line which is higher of the two shall be provided.
Note 5 : In the case of corner sites both the sides facing the road shall be treated as front side and regulations applied accordingly to maintain the building line on these roads and to provide better visibility.
Note 6 : In the case of a building facing more than two roads, the plot should be considered as corner plot taking two wider roads into consideration.
Note 7 : In the case of sites facing roads both in front and rear, both the sides facing roads should be treated as front and other two sides not facing roads should be treated as right and the setbacks be applied accordingly.
Note 8 : In case where the plinth of the building is not parallel to the property line, the setbacks shall not be less than the specified setbacks at any given point on any side.
Note 9 : In case of irregular plots the set-backs are to be calculated according to the depth or width at the points where the depths or widths are varying. Average set-backs shall not be considered in such cases.
Note 10 : The left and right set-backs may be interchanged by the Authority in exceptional cases due to existing structures like; open well and also considering the topography of the land. However, this shall be resorted to by the Authority only as an exception.
Note 11: Set-backs should be provided in the owner’s plot. Public open space or conservancy should not be considered as set-backs.
Note 12: In case of two or more buildings proposed on a single site, the set-backs shall be applied by considering them as a common building. In such cases, the distance between the two buildings shall be minimum of half the height of the taller building.
Note 13: For plots with an area of more than 750 sqm. bell mouth entrance shall be provided.
Note 14: The front set back mentioned above are minimum. The building shall be shifted back to the building lines, if any declared by any competent authority.
9.3 High rise buildings.
9.3.1 In the case of ‘high-rise buildings’ the minimum set-back all-round the building shall be as in Table 5.
9.3.2 Minimum depth or width of a site for high rise buildings shall be 21 mtrs.
9.3.3. Minimum road width facing a high rise building shall be 12mts.
9.4Garages
9.4.1. For the buildings upto a height of 9.50 metres, one garage may be permitted in the rear right hand corner of the plot without right and rear set backs, if the following requirements are fulfilled, namely
a) height of the garage does not exceed 3.00 Metres from the ground level;
b) not more than one upper floor is proposed over such a garage;
c) height of the garage and the upper floor, if any, is limited to 6.50 Metres from the ground level;
d) no other structure is proposed over upper floor of the garage;
e) no openings are provided in the garage and its upper floor towards the neighbouring buildings;
f) the upper floor is accessible only from lower floor;
g) not exceeding one side door is provided to the garage at the ground level towards the rear setback of the building;
h) no other structures except one lumber room and a stair case are provided in the rear side of the garage;
i) depth of the lumber room does not exceed 1.25 Metres;
j) length of the garage including the lumber room and stair case does not exceed one third of the length of the site or 6 Metres, whichever is less;
k) width of the garage does not xceed 4 metres;
l) the distance from the outer surface of the garage to the plot boundary is not less than 4.50 metres;
m) in the case of corner plots, the garage is located at the rear corner diagonally opposite to the road intersection.
9.4.2. A Garage not exceeding 3.00 metres width may be permitted as part of the main building with minimum setbacks applicable to such a building, provided such a garage is not located at the intersection of roads in the case of corner sites. The length of the garage shall not exceed one third of the length of the corresponding side of the site or 6.00 metres, whichever is less.
9.5 Provision of ramp in setback :
A ramp provided from surface level of the site to the basement floor shall have a minimum width of 3.50 meters and slope of not more than 1 in 10. The ramp shall have a margin of two meters kept free from the adjacent properties. The gradient of a ramp shall start after leaving a minimum distance of one metres from the front boundary of the plot.
In the case of high rise buildings, the ramp may be provided in the set back area without affecting the free movement of fire tenders.
9.6Application of land use :
9.6.1. Where the nomenclature of a road differs from the one mentioned in the district maps of the development plan, the location of the site may be considered to determine the land use.
9.6.2. In cases of permitted land use, the Zoning Regulations shall be applied to a building keeping in view the use of the proposed building without reference to the land use of the Zone. However, the front set back shall be the higher of the one prescribed for that particular zone or the one prescribed for the use permitted in the zone.
Example: If residential permission is granted in a commercial zone, the regulations applicable to residential use only be adopted except maintaining the higher of the front set back applicable either to commercial or residential use.
9.6.3. The land use indicated towards the road side of a property shall be the land use for the entire property (one property depth) without identifying it for different uses by measuring as per the scale of the maps.
9.6.4. Different uses permitted in a given zone may be allowed in different floors of the building. In such cases, the regulations applicable to the use of the ground floor of the building shall apply to the entire building. When mixed land uses are permitted in the ground floor, the predominent use among them shall be considered as the use of the ground floor.
9.7 Plots facing the roads proposed for widening :
Where upper floors are permitted over the existing buildings which are sanctioned prior to the coming into force of these bye-law s and which are facing the roads proposed for widening in the development plan, the upper floors shall be limited to the proposed line of road widening or building line, if any prescribed.
9.8Additions, alterations and modifications :
i) Any additions, alterations & modifications to existing buildings shall be permitted in accordance with these bye-laws.
ii) In case of the buildings which are existing prior to coming into force of these regulations, upper floors may be permitted according to the existing set-backs only, but limiting the F.A.R. and the number of floors according to the present bye-laws, subject to production of the foundation certificate as prescribed in the bye-law no. 3.2 (9).
9.9 Interior open spaces – The whole of one side of one or more rooms intended for human habitation and not abutting on any of the front, rear or side open spaces shall abut on an interior open space of minimum width of 3 m.
9.10Limitations of floor area and covered area
9.10.1 The coverage, and FAR, for different sizes of plots with reference to existing road width as limiting factor are given in the table No.6 for various types of buildings like residential, commercial, public and semi-public, etc. The local planning area of Bangalore City is divided into A, B & C areas by the Bangalore Development Authority for the purpose of regulating building constructions as under:-
A: Intensely developed area.
B: Moderately developed area.
C: – Sparsely developed area .
Note: (1) A map showing the details of A, B and C areas is available in the office of the Bangalore Development Authority, Bangalore.A copy of this map is appended to these bye-law s.
Note: (2) When two sides of the same road are included in two different areas like: A and B or A and C, then both the sides shall be treated as intensively developed area (‘A’ area) up to one property depth.
Note: (3) When two sides of the same road are included in two different areas like: B and C, then both the sides shall be treated as moderately developed area (‘B’ area) up to one property depth.
9.10.2 In respect of the following buildings, the maximum coverage shall be as prescribed below.
Building
Permissible maximum coverage
a. Hospital
25%
b. Health centre/nursing home
33.33%
c. Nursery school/primary school
33.33%
d. Secondary school
30%
e. College
25%
9.10.3 (a) The floor area of a building shall be the aggregate area of the floors of all parts of the building including thickness of walls, parking area, staircase rooms, lift rooms, ramps, escalators, machine rooms, balconies, ducts including sanitary ducts, water tanks, lobbies, corridors, foyers and such other parts provided for common service.
(b) The floor area ratio shall exempt the floor area used for the following purposes, namely:-
(i) parking space (ii) staircase rooms (iii) lift rooms (iv) ramps (v) escalators (vi) machine rooms (vii) open balconies (viii) ducts including sanitary ducts and (ix) water tanks.
(c) Parking area shall be exempted to the extent required for the building.
(d) The area covered by the following structures on the roof are exempted from the floor area upto fifteen percent of the area of the roof over which they are erected, namely:-
(i) staircase rooms (ii) lift machine rooms (iii) pent house (iv) water tanks (v) equipments for ventilation, air conditioning and similar services.
(e) Lobbies, corridors provided in the plan shall be considered for F.A.R.
(f) The nomenclature of certain roads may differ with those mentioned in the District Maps of the Revised C.D.P. In such cases, the location of the site may be considered to determine the land use.
Note : One penthouse only is permissible for a building. The area of the penthouse with staircase room shall be limited to 19 sq.mtrs. If this limit is exceeded, the structures shall be considered for reckoning the FAR.
9.10.4 When sites do not face the roads of required width noted against each, then the FAR applicable to the corresponding width of roads shall apply.
9.10.5 When a site faces wider road than the one prescribed against it, the FAR shall be restricted only to the limit prescribed for the area of that particular site.
9.10.6 When coverage is less than the maximum prescribed in Table 6, floors and height beyond the limits indicated in table 5 may be permitted to utilise the full FAR subject to the provision of minimum set backs prescribed in Tables 4 and 5, whichever is applicable.
9.10.7 The set-backs and coverage shall be determined irrespective of the width of the road.
9.10.8 Buildings for cinemas - Setbacks and other requirements for permanent or other cinema buildings shall be in accordance with the Karnataka Cinemas (Regulation) Act 1964 and the rules made there under. No building other than a cinema theatre shall be permitted on the sites of cinema theatres unless such buildings are permissible under the above said Act.
9 .10.9 Minimum Road Width for Kalyana Mantapas –
TABLE - 6A
Site Area
Minimum Road width
a) Upto 250Sq.Mtrs.
9.00 Mtrs
b) Over 250 Upto 500 Sq.Mtrs
12.00 Mtrs
c) Over 500 Upto 1000 Sq.Mtrs
15.00 Mtrs
d) Over 1000 Sq.Mtrs
18.00 Mtrs
10.0Semi-detached houses (back to back or side to side) - Setbacks, coverage, floor area ratio and road width in respect of semi-detached houses shall be as indicated in Table 7.
TABLE 7
(Bye-law 10.0) SEMI-DETACHED HOUSES (back to back or side to side)
Min. combined area of the neighbouring plots
140 sq. mtr.
Coverage
Floor area ratio
Maximum number of floors
Minimum road width
As applicable to Individual plots
Front setbacks for back to back plots:
Shall be equal to the sum of the front and the rear set backs of individual plots
Side set back for plots joined at the side
On a plot on which a semi detached building is proposed the left and the right side setbacks shall be the same as required for the total width of the combined plot treating it is an individual site
11.0 Row housing: Row housing shall have a minimum of three dwelling units and a maximum of 12 dwelling units on one site. Other stipulations are prescribed in Table 8
TABLE 8(Bye-law 11.0)Row housing
1. Min. combined area of plot
:
210 sq. mtr.
2. Max. area of each plot
:
108 sq. mtr
3. Coverage
:
4. Floor area ratio
:
As applicable to
5. Number of floors
:
Individual plots
6. Minimum road width
:
7. Setbacks min.
Front
2.00 m
Rear
1.50 m
Side
2.00 only for end units
12.0 Group Housing
12.1Norms for Approval of Group Housing Plan
The following norms shall be adopted while approving the layout plan for group housing:-
i) The boundary roads if any must have a minimum width of 12 mtr.
ii) The FAR should be considered with reference to the width of the public road abutting the property and the FAR should be calculated after deducting the area reserved for parks, open spaces and civic amenities.
iii) The set-backs should be provided with reference to depth and width of total plot area.
iv) The coverage shall be with reference to total area of the layout.
v) The distance between the buildings should be a minimum of half of the hieght of the tallest building.
vi) 25% of the total area be reserved for CA, parks and open spaces, subject to a minimum of 15% for parks and open space.
vii) The means of access to the building blocks in the area of group housing shall be as follows:
Access length in mtrs. Min. width
a) Less than 100 mtrs. 6 mtrs.
b) 100 to 200 mtrs. 9 mtrs.
c) More than 200 mtrs. 12 mtrs.
vii) The area reserved for Parks and Open spaces, CA and roads (other than internal access in each sub-divided plot) shall be handed over free of cost to the B.D.A through registered relinquishment deed before issue of work order.
TABLE 10(Bye-law 13.1) EXTERIOR SET-BACKS, COVERAGE AND F.A.R. FOR INDUSTRIAL BUILDINGS
Plot Area in sq. mtrs
Industry
Maximum plot coverage
Min. set back in Mtrs.
F.A.R.
Road width In mtrs.
Front
Rear & sides
Upto 240
Service
75%
1.00
-
1.00
Over 4.5
Over 240 upto 1000
Service and Light
50%
4.50
4.50
0.75
Over 6.0
Over 1000
Service and Light
upto 2000
50%
6.00
6.00
0.75
Over 9.0
Over 2000
Service, Light and
upto 3000
Medium
40%
10.00
10.00
0.75
Over 12.0
Over 3000
Service, Light and
upto 4000
Medium
40%
12.00
12.00
0.50
Over 12.0
Over 4000
Service, Light, Medium and Heavy
35%
15.00
15.00
0.50
Over 12.0
Note: After leaving minimum set-backs as per the above table, if the remaining portion of the plot cannot be used for erecting the building, the Authority may insist the set backs applicable for residential buildings.
TABLE 11 (Bye-law 13.2) REGULATIONS FOR FLATTED FACTORIES
Minimum plot area
: 1000 sq. mtrs.
Maximum coverage
: 40%
Maximum F.A.R.
1.50 upto 9 mtrs. road width, and
1.75 above 9 mtrs. road width
Minimum setbacks
a. Front 8.0 mtrs.
b. Rear 4.5 mtrs.
c. Sides 4.5 mtrs.
Note: If the height of the building exceeds 9.5 metres, the minimum set back shall be the higher of the two in Tables 5 and 11.
Exemptions in open space - The following exemptions in open space shall be permitted.
14.1 Projections - (1) Every open space provided either interior or exterior shall be kept free from any structure thereon and shall be open to sky and no cornice, roof or weather shade or chajja more than 0.75 metres wide or 1/3 of open space whichever is less shall over-hang or project over the said open space. These projections shall be permitted within one’s own plot boundaries.
(II) No projection shall over hang or project over the minimum setback area either in the cellar floor or at the lower level of the ground floor.
14.2 Cantilever Portico - A cantilever portico of 3 metres width (maximum) and 4.5 metres length (maximum) may be permitted in the ground floor within the side set back. No access is permitted to the top of the portico for using it as a sit out. Height of the portico shall be not less than 2 metres from the plinth level. The terrace of the portico shall be open to sky. The portico when allowed shall have a clear open space of one meter from the boundary of the property.
14.3 Balcony - The projection of the balcony shall be measured perpendicular to the building upto the outermost edge of the balcony. Cantilever projection of the balcony shall be permitted not exceeding 1/3 of the setback subject to a maximum of 1.1 mtrs. in the first floor and 1.75 metres in and above the second floor. No balcony is allowed at the ground floor level. The length of the balcony shall be limited to 1/3 of the length of each side of the building.
14.4 Cross wall - A cross wall connecting the building and the boundary wall may be permitted limiting the height of such wall to 1.5 mtr.
15.0Height limitation
15.1 The height of the building shall be governed by the limitation of the FAR, coverage, setbacks and the width of the street facing the plot as stipulated in the respective tables.
15.2 If a building abuts two or more streets of different widths, then the height of the building shall be regulated according to the width of the wider road.
15.3 For buildings within the landing and take off zones of air craft in the vicinity of aerodromes, the maximum height of the building shall be as permissible in 15.1 above, or as shown in Table 12 whichever is lower. These shall be regulated by the rules for the construction of buildings in the vicinity of aerodromes by the competent Aerodrome Authority.
15.4 Height exception for the structures on roof: The following appurtenant structures shall not be included in the height of the building.
i) Water tanks and their supports, equipments for ventilation, air-conditioning and similar services, lift rooms, roof structures like; stair-case room, pent house, chimneys, parapet walls and other architectural features.
ii) The height of parapet wall and architectural features shall not exceed 1.0 metre and the height of other structures shall not exceed 4.50 meters for claiming the height exemption.
iii) The aggregate area of such structures shall be limited to the extent prescribed in the byelaw 9.10.3 (d). If this limit is exceeded, the structures shall be considered for reckoning the height of the building.
TABLE 12 (Bye-law 15.3)
HEIGHT LIMITATIONS IN THE VICINITY OF AERODROMES (a) International civil air-ports and their alternates:
Limits of distance from the aerodromes point measured horizontally to buildings/structures or installations
Difference between the elevation of the top of the buildings/structures of installations and the elevation of the aerodromes (aerodromes reference point)
1 Between 8534 M and 22224 M
Less than 152 M
2 Between 7315 M and 8534 M
Less than 122 M
3 Between 6096 M and 7315 M
Less than 91 M
4 Between 4877 M and 6096 M
Less than 61 M
5 Between 4267 M and 4877 M
Less than 49 M
6 Between 3658 M and 4267 M
Less than 37 M
7 Between 3048 M and 3658 M
Less than 24 M
8 Between 2438 M and 3048 M
Less than 12 M
9 Below 2438 mtrs.
Nil except with the prior concurrence of the local Aerodrome Authority
(b) other civil airports and civil aerodromes:
1 Between 7925 M and 22324 M
Less than 152 M
2 Between 6706 M and 7925 M
Less than 122 M
3 Between 5486 M and 6706 M
Less than 91 M
4 Between 4267 M and 5486 M
Less than 61 M
5 Between 3658 M and 4267 M
Less than 49 M
6 Between 3048 M and 3658 M
Less than 37 M
7 Between 2438 M and 3048 M
Less than 24 M
8 Between 1829 M and 2438 M
Less than 12 M
9 Below 1829 M
Nil except with the prior concurre Aerodrome Authority.
Note: 1) For sl. Nos. (7), (8) and (9), no trees shall be planted within the limits of the distance indicated thereto.
Irrespective of the distance from the aerodrome beyond 22,224 mtrs. of the aerodrome/aerodrome reference point, no radio masts or such similar type of installations exceeding 152 mtrs. in height should be erected with out prior permission of the concerned civil aviation authority.
No buildings structures or installations exceeding the height indicated in (a) and (b) of Table 12 should be permitted without prior consultation with the local authority.
Location of slaughter houses, butcheries and other areas of activities like garbage dumps which would attract high flying birds like eagles, hawks etc., shall not be permitted within a radius of 10 kilometres. from the aerodrome reference point.
16.0 Parking space - Adequate space for the parking of vehicles shall be provided in the sites as per standards given in Table 13 subject to the following stipulations.
a) Each off street car parking space provided for motor vehicles shall not be less than 18 sq.mtrs (3 meters x 6 meters). For motor cycles and scooters, each parking space shall not be less than 2.5 sq.mtrs. (1.25 meters x 2 meters) and for cycles it shall not be less than 1.5 sq.metres. (0.75 meters x 2 meters).
b) Off street car parking space shall be provided with adequate vehicular access to a street and areas of drives of not less than 2.5 mtr. wide, aisles and such other provisions required for adequate monitoring of vehicles shall be exclusive of the parking space stipulated in these bye-laws.
c) No parking space shall be insisted upon in the intensely developed area of the floor space upto 100 sq.meters.
d) In case of non-high rise buildings parking space may be provided in the set back, where the set- back is 6 meters. In such cases, the minimum margin of 3 meters shall be kept free from the building.
e) In case of high rise buildings parking space may be provided in the set back after leaving a minimum setback of 6 Mtrs alround the building to enable movement of Fire Tender.
f) Alternate means of parking such as terrace parking, multi stage parking, parking silos may be permitted, subject to production of NOC’s from the Authorities (in case of high rise buildings). In such cases, a clear height of 3.6 Meters in the basement floor has to be provided, and the space to be earmarked per unit of Car parking may be determined by the authority.
g) Parking in the upper floors can be allowed only if ramps are provided after leaving the minimum setback line to reach such floors.
h) Parking to be allowed on stilts should not be considered as a separate floor and the same shall be exempted from computing the height of the building provided the total height of the building does not exceed 15.00 Mtrs.
TABLE 13(Bye-law 16.0) PARKING REQUIREMENTS
Sl.No.
Type of use
One car parking space shall be provided for every
1
a) Theatres and auditoriums including cinema theatres (except educational institutions);b) Multiplex Theaters
25 seats of accommodation subject to a minimum of 2015 seats of accommodation subject to a minimum of 10
2
Retail business
50 sq. mtr. of floor area
3
Wholesale and warehouse buildings
150 sq. mtr of floor area plus 1 lorry parking space measuring 4 x 8 mtrs. for every 500 sq.mtr. or part thereof.
4
Restaurants, Establishments serving food and drinks and such other establishments
25 sq.mtr. of floor area including hall, dining room, pantry & bar.
5
Lodging establishments and tourist homes
4 rooms
6
Office-buildings (Govt./Semi-Govt. & Pvt.)
50 sq.mtrs. of office floor space.
7
Hostels
10 rooms
8
Industrial buildings
100 sq.mtr. of floor area plus 1 lorry space measuring 4 x 8 mtr. For every 1000 sq.mtr. or part thereof.
9
Nursing homes & Hospitals
4 beds
10
(i) Single Family Dwellings
a) Dwelling Unit measuring 100 to 150 Sq.Mtrsb) 100 Sq.Mtrs and Part thereof beyond 150 Sq.Mtrs.
(ii) Multi Family Dwellings
a) 2 Dwelling units measuring 50 Sq.Mtrs or less.b) Dwelling unit measuring over 50 Sq.Mtrs upto 150 Sq.Mtrs.c) 100 Sq.Mtrs and part thereof beyond 150 Sq.Mtrs
11
Kalyana mandiras
10 sq.mtr. of auditorium floor area
12
Recreation clubs
50 sq.mtr. of floor area
13
Educational buildings
200 sq.mtr. of floor area
14
Other public and semi-public buildings
100 sq. mtr. Of floor area
NOTE: In addition to the above 10% additional parking space shall be provided for parking of visitor’s vehicle’s in case of residential and commercial buildings at serial numbers 5, 6, 7, 9, 10(ii), 12, 13 and 14.
17.0 Buildings at intersection of streets - At the intersection of streets, the corners of the boundary of the plot shall be rounded off or cut-off after leaving a minimum distance of 10% of the frontage of the plot or 3 mts whichever is less from the point of intersection. The Authority may further require the corner of the building to be rounded off or cut-off
parallel to the rounded off or cut-off boundary upto the height of the ground floor. In such cases the FAR is to be allowed for the total area of the plot. Entry or exit for the buildings shall be provided away from the point of intersection.