9.1 Open spaces – Every room intended for human habitation shall abut on an interior or exterior open space or open verandah open to such interior or exterior open space.
9.2 Exterior open spaces/ set backs, coverage, floor area ratio, numbers of floors and heights - The set backs required on all the sides of building/s, maximum plot coverage, maximum FAR, maximum number of floors, maximum height of buildings that are permissible for different dimensioned sites and widths of roads are set out in Tables 4, 5 and 6 given below.
TABLE 4
(Bye-law 9.2)
EXTERIOR OPEN SPACES/SETBACKS IN METRES FOR RESIDENTIAL, COMMERCIAL, PUBLIC & SEMI-PUBLIC, TRAFFIC & TRANSPORTATION AND PUBLIC UTILITY BUILDINGS
UPTO 9.5 MTRS. IN HEIGHT
| Depth of site in mtrs. | Residential - Front | Residential - Rear | Commercial - Front | Commercial - Rear | T & T. P.U.& Public and Semi-Public - Front | T & T. P.U.& Public and Semi-Public - Rear | Width of site in mtrs. | Residential - Left | Residential - Right | Comercial - Left | Comercial - Right | T & T. P.U. & Public and Semi Public - Left | T & T. P.U. & Public and Semi Public - Right |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Upto 6 | 1.00 | - | 1.00 | - | 1.50 | - | Upto 6 | - | 1.00 | - | - | - | 1.50 |
| Over 6 upto 9 | 1.00 | 1.00 | 1.50 | - | 1.50 | 1.50 | Over 6 upto 9 | 1.00 | 1.00 | - | 1.50 | 1.50 | 1.50 |
| Over 9 upto 12 | 1.50 | 1.50 | 1.50 | 1.50 | 3.00 | 1.50 | Over 9 upto 12 | 1.50 | 1.50 | 1.50 | 1.50 | 1.75 | 1.50 |
| Over 12 upto 18 | 3.00 | 1.50 | 3.00 | 1.50 | 3.00 | 1.50 | Over 12 upto 18 | 1.50 | 3.00 | 1.50 | 3.00 | 2.00 | 3.00 |
| Over 18 upto 24 | 4.00 | 3.00 | 3.50 | 3.00 | 4.50 | 2.00 | Over 18 upto 24 | 2.50 | 3.50 | 2.50 | 4.00 | 3.00 | 3.00 |
| Over 24 | 5.00 | 3.50 | 4.50 | 3.00 | 6.00 | 3.00 | Over 24 | 3.00 | 4.00 | 3.00 | 4.50 | 3.50 | 4.50 |
Abbreviations T & T = Traffic & Transportation, P.U. = Public utility.
TABLE 5 (Bye-law 9.2)
EXTERIOR OPEN SPACES/SET-BACKS FOR RESIDENTIAL, COMMERCIAL, PUBLIC AND SEMI-PUBLIC, TRAFFIC & TRANSPORTATION , PUBLIC UTILITY BUILDINGS – ABOVE 9.5 MTS. IN HEIGHT
| Sl. No. | Height of Building in mtrs. | Exterior open spaces / set-backs to be left on all sides (Front, Rear and Sides) in mtrs. |
|---|---|---|
| 1 | Above 9.5 upto 12 | 4.5 |
| 2 | Above 12 upto 15 | 5.0 |
| 3 | Above 15 upto 18 | 6.0 |
| 4 | Above 18 upto 21 | 7.0 |
| 5 | Above 21 upto 24 | 8.0 |
| 6 | Above 24 upto 27 | 9.0 |
| 7 | Above 27 upto 30 | 10.0 |
| 8 | Above 30 upto 35 | 11.0 |
| 9 | Above 35 upto 40 | 12.0 |
| 10 | Above 40 upto 45 | 13.0 |
| 11 | Above 45 upto 50 | 14.0 |
| 12 | Above 50 | 16.0 |
TABLE 6
(Bye-law 9.2 and 9.10) COVERAGE AND FAR FOR RESIDENTIAL, COMMERCIAL, PUBLIC AND SEMI-PUBLIC, TRAFFIC & TRANSPORTATION, AND PUBLIC UTILITY BUILDING
| Plot Area in Sq. mtr. | Residential | Commercial | Public & Semi Public T&T & Public Utilities | Road width (Mtrs) | |||||
| Plot Cove-rage Max. | F.A.R. Max. | Plot Cove-Rage Max. | F.A.R. Max. | Plot Cove-rage Max. | F.A.R Max. | ||||
| A - INTENSELY DEVELOPED AREA | |||||||||
| Upto 240 | 65% | 0.75 | 65% | 1.00 | 60% | 1.00 | Upto 6 | ||
| Over 240 Upto 500 | 60% | 0.75 | 60% | 1.00 | 55% | 1.00 | Over 6 upto 9 | ||
| Over 500 Upto 750 | 60% | 1.00 | 60% | 1.25 | 50% | 1.00 | Over 9 upto 12 | ||
| Over 750 Upto 1000 | 60% | 1.00 | 60% | 1.25 | 50% | 1.25 | Over 12 upto 15 | ||
| Over 1000 | 60% | 1.25 | 55% | 1.50 | 45% | 1.25 | Over 15 | ||
| B - MODERATELY DEVELOPED AREA | |||||||||
| Upto 240 | 65% | 1.00 | 65% | 1.25 | 60% | 1.00 | Upto 9 | ||
| Over 240 Upto 500 | 60% | 1.25 | 60% | 1.50 | 55% | 1.25 | Over 9 upto 12 | ||
| Over 500 Upto 750 | 60% | 1.25 | 60% | 1.50 | 50% | 1.25 | Over 12 upto 15 | ||
| Over 750 Upto 1000 | 60% | 1.50 | 60% | 1.75 | 50% | 1.50 | Over 15 upto 18 | ||
| Over 1000 | 60% | 1.75 | 55% | 1.75 | 45% | 1.50 | Over 18 | ||
| C - SPARSELY DEVELOPED AREA | |||||||||
| Upto 240 | 65% | 1.00 | 65% | 1.25 | 60% | 1.25 | Upto 9 | ||
| Over 240 Upto 500 | 60% | 1.25 | 60% | 1.50 | 55% | 1.50 | Over 9 upto 12 | ||
Note 1: The dimensions in British system if any, adopted for the dimensions of plots may be interpreted as follows in Metric system and set backs may be applied accordingly.
Note 2 : The open spaces to be provided shall conform to the height necessary to consume the permissible FAR.
Note 3: (a) The front and rear set backs shall be with reference to the depth of the site.
(b) The left and right set backs shall be with reference to the width of the site.
(c) If the height of a building exceeds 9.5 metres, the set backs to be provided shall be higher of the set backs specified in tables 4 and 5.
Note 4 : Building lines have been prescribed to certain roads by the Bangalore Development Authority in Table 33 of the Zoning Regulations. This table is appended as Schedule X to these bye-laws. In such cases, the front set back or the building line which is higher of the two shall be provided.
Note 5 : In the case of corner sites both the sides facing the road shall be treated as front side and regulations applied accordingly to maintain the building line on these roads and to provide better visibility.
Note 6 : In the case of a building facing more than two roads, the plot should be considered as corner plot taking two wider roads into consideration.
Note 7 : In the case of sites facing roads both in front and rear, both the sides facing roads should be treated as front and other two sides not facing roads should be treated as right and the setbacks be applied accordingly.
Note 8 : In case where the plinth of the building is not parallel to the property line, the setbacks shall not be less than the specified setbacks at any given point on any side.
Note 9 : In case of irregular plots the set-backs are to be calculated according to the depth or width at the points where the depths or widths are varying. Average set-backs shall not be considered in such cases.
Note 10 : The left and right set-backs may be interchanged by the Authority in exceptional cases due to existing structures like; open well and also considering the topography of the land. However, this shall be resorted to by the Authority only as an exception.
Note 11: Set-backs should be provided in the owner’s plot. Public open space or conservancy should not be considered as set-backs.
Note 12: In case of two or more buildings proposed on a single site, the set-backs shall be applied by considering them as a common building. In such cases, the distance between the two buildings shall be minimum of half the height of the taller building.
Note 13: For plots with an area of more than 750 sqm. bell mouth entrance shall be provided.
Note 14: The front set back mentioned above are minimum. The building shall be shifted back to the building lines, if any declared by any competent authority.
9.3 High rise buildings.
9.3.1 In the case of ‘high-rise buildings’ the minimum set-back all-round the building shall be as in Table 5.
9.3.2 Minimum depth or width of a site for high rise buildings shall be 21 mtrs.
9.3.3. Minimum road width facing a high rise building shall be 12mts.