Reinforced concrete framed buildings
| SI.No. | Description | Information | Notes |
| 1. | Type of Building | IS 1893 Cl. 7.1 | |
| Regular frames | |||
| Regular frames with Shear walls | |||
| Irregular frames | |||
| Irregular frames | |||
| Irregular frames with shear walls | |||
| Soft storey | |||
| 2. | Number of basements | ||
| 3. | Number of floors including ground floor | ||
| 4. | Horizontal floor system | ||
| Beams and slabs | |||
| Waffles | |||
| Ribbed Floor | |||
| Flat slab with drops | |||
| Flat plate without drops | |||
| 5. | Soil data | IS 1498 | |
| Type of soil | |||
| Recommended type of foundation | |||
| - Independent footings | |||
| - Raft | |||
| - Piles | |||
| Recommended bearing capacity of soil | |||
| Recommended, type, length, diameter and load capacity of piles | |||
| Depth of water table | |||
| Chemical analysis of ground water | |||
| Chemical analysis of soil | |||
| 6. | Foundations | ||
| Depth below ground level | |||
| Type | |||
| * Independent | |||
| * Interconnected | |||
| * Raft | |||
| * Piles |
[PART I
| 7. | System of interconnecting foundationsPlinth beamsFoundation beamsDescription | Information | IS: 1893C1.7.12.1Notes |
|---|---|---|---|
| SI.No. | |||
| 8. | Grades of concrete used in different parts of building | ||
| 9. | Method of analysis used | ||
| 10. | Computer software used | ||
| 11. | Torsion included | ||
| 12. | Base shear | IS: 1893 Cl. 7.5.3 | |
| a. Based on approximate fundamental period | |||
| b. Based on dynamic analysis | |||
| c. Ratio of a/b | |||
| 13. | Distribution of seismic forces along the height of the building | IS: 1893 Cl. 7.7(Provide sketch) | |
| 14. | The Column of soft ground storey specially designed | IS: 1893 Cl. 7.10 | |
| 15. | Clear minimum cover provided in | IS: 456 Cl. 26.4 | |
| • Footing | |||
| • Column | |||
| • Beams | |||
| • Slabs | |||
| • Walls | |||
| 16. | Ductile detailing of RC frame | ||
| • Type of reinforcement used | |||
| • Minimum dimension of beams | IS: 456 Cl. 5.6 | ||
| • Minimum dimension of columns | IS: 13920 Cl. 6.1 | ||
| • Minimum percentage of reinforcement of beams at any cross section | IS: 13920 Cl. 7.1.2IS: 456 Cl. 26.5. 1.1.(a) | ||
| • Maximum percentage of reinforcement at any section of beam | IS: 13920 Cl. 6.2.1.IS: 456 Cl. 26.5.1.1.(b) | ||
| • Spacing of transverse reinforcement in 2-d,length Qf beams near the ends | IS: 13920 Cl. 6.2.2.IS: 13920 Cl. 6.3.5. | ||
| • Ratio of capacity of beams in shear to capacity of beams in flexure | |||
| • Maximum percentage of reinforcement in column | |||
| • Confining stirrups near ends of columns and in beam-column joints | IS: 456 Cl. 26.5.3.1. | ||
| a) Diameter | |||
| b) Spacing | |||
| * Ratio of shear capacity of columns to maximum seismic shear in the storey |
91
General Notes
-
A certificate to the effect that this report will be completed and submitted with the application for Building Development Permission.
-
In addition to the completed report following additional information shall be submitted, at the latest, one month before commencement of Construction.
2.1 Foundations
2.1.1. In case raft foundation has been adopted indicate K. value used for analysis of the raft
2.1.2 In case pile foundations have been used give full particulars of the piles, type, dia, length, capacity.
2.1.3. In case of high water table indicate system of countering water pressure, and indicate the existing water table, and that assumed to design foundations.
2.2 Idealization for Earthquake analysis
2.2.1 In case of a composite system of shear walls and rigid frames, give distribution of base shear in the two systems on the basis of analysis, and that used for design of each system.
2.2.2 Indicate the idealization of frames and shear walls adopted in the analysis with the help of sketches.
2.3 Submit framing plans of each floor.
2.4 In case of basements, indicate the system used to contain earth pressures.
Buildings in Structural Steel
| 1. | Adopted method of Design | o Simple | IS: 800; CI. 3.4.5 |
| o Semi-rigid | IS: 800; CI. 3.4.5 | ||
| o Rigid | IS: 800; CI 3.4.6. | ||
| 2. | Design based on | o Elastic analysis | IS: 800; Section-9 |
| o Plastic analysis | SP: 6 (6) | ||
| 3. | Floor Construction | o Composite | |
| o Non-composite | |||
| o Boarded | |||
| 4. | Roof Construction | o Composite | |
| o Non-composite | |||
| o Metal | |||
| o Any other | |||
| 5. | Horizontal force resisting system adopted | o Frames | Note: Seismic force as per |
| o B raced frames | IS : 1893 would depend on system. | ||
| o Frames & shear walls | |||
| 6. | Slenderness ratios maintained | Members defined in Table 3.1, IS 800 | IS: 800; CI. 3.7 |
| 7. | Member deflection limited to | Beams, Rafters | IS: 800; CI. 3.13 |
| Crane Girders | |||
| Purlins | |||
| Top of Columns |
[PART I
| 8. | Structural members | o Encases in concreteo Non encased | IS: 800: Section-l0 |
|---|---|---|---|
| 9. | Proposed material | o General weld-ableo High strengtho Cold formedo Tubular | IS:2062IS: 8500IS: 801,811IS: 806 |
| 10. | Minimum metal thickness Specified for corrosion protection | o Hot rolled sectionso Cold formed sectionso Tubes |