137 Building Services
(l) The planning, design and installation of electrical fittings, air-conditioning and heating work, installation of lifts and escalators shall be carried out in accordance with the provisions of Electrical Installation, Air-Conditioning and Heating, Installation of Lifts and Escalators on Building Services of the latest edition of the National Building Code of India. For electrical aspects of the building services the provisions of the latest edition of National Building Code shall apply.
(2) The number or type of lifts to be provided in different buildings shall be as specified in the latest edition of National Building Code of India.
(3) Electrical Installations in respect of any building exceeding thirteen and a half m. in height shall conform to the provisions of the latest edition of National Electrical Code.
138 Plumbing Services
(1) The planning, design, construction and installation of water supply, drainage and sanitation and gas supply system shall be in accordance with the provisions of water supply, drainage and sanitation, gas supply and plumbing services of the latest edition of National Building Code of India.
(2) The underground reservoir shall be constructed in such a way that the manhole portion must be raised 300 mm. or more above ground level to avoid surface contamination. The inlet supply pipe always be kept above the higher level of the stored water surface.
(3) All other requirements regarding plumbing services, not specifically mentioned in this rule shall conform to the provisions of the latest edition of National Building Code of India.
(4) The depth of the underground water reservoir/septic tank/inspection pits or manhole should not be more than the shallowest foundation depth and the distance between the edge of foundation and such underground structure should not be less than 50% of the width of the. underground structure provided however, this provision will not be applicable for such structures appearing at a distance of 4.0 m. or more from the main foundation line of the building.
139 Signs and outdoor display structures
(1) The construction of advertising signs and outdoor display structures shall be in accordance with the provisions regarding Signs and Outdoor Display Structures in the latest edition of the National Building Code of India.
(2) Every building shall display in a prominent place on the front side the premises number as assigned to it by the Corporation and the street name so as to be conveniently visible from any street.
[PART I